• Title/Summary/Keyword: detection measure

Search Result 1,328, Processing Time 0.027 seconds

The ultrasonographic estimate of renal arteries in the dog (개에 있어서 신장혈관의 초음파적 평가에 관한 연구)

  • Kang, Suk-jae;Bae, Chun-sik;Kim, Hwi-yool;Chang, Kyung-jin
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.1
    • /
    • pp.230-239
    • /
    • 1999
  • Digital color doppler ultrasonographic system(DCDUS) has a lot of diagnostic functions. One of these is a detection of low velocity vessels in the organs of abdominal cavity. The purpose of study was to determine the clinical usefulness of DCDUS. Interlobar artery resistive index(RI), pulsatility index(PI) and systolic diastolic ratio(SDr) were measured for diagnosis of obstructed urinary tract. RI, PI and SDr were a measure of intrarenal blood flow impedance. This study was consisted of 2 groups. The normal group was studied in 16 normal adult dogs and the study group was studied 7 dogs with surgically induced, unilateral ureteral obstruction. In the study group, parameters were checked in normal condition and on 1, 2, 3, 5, 7 and 10th day after ligation. The result were summarized as follows. In the normal group, RI, PI and SDr of the left kidney was $0.65{\pm}0.04$, $1.25{\pm}0.12$ and $292.45{\pm}29.40$, respectively. RI, PI and SDr of the right kidney were $0.64{\pm}0.05$, $1.28{\pm}0.20$ and $282.25{\pm}37.26$, respectively. In the study group, RI of the left kidney induced ligation was increased significantly on 1, 2, 3, 5, 7 and 10th day. RI of the left kidney on 1, 2, 3, 5, 7 and 10th day were $0.75{\pm}0.05$, $0.71{\pm}0.03$, $0.74{\pm}0.04$, $0.74{\pm}0.02$, $0.73{\pm}0.02$ and $0.73{\pm}0.04$, respectively. PI of the left kidney was increased significantly on 1, 3, 5 and 7th day. PI of the left kidney on 1, 3, 5 and 7th day were $1.57{\pm}0.21$, $1.54{\pm}0.24$, $1.60{\pm}0.15$ and $1.60{\pm}0.26$, respectively. SDr of the left kidney increased significantly on 1, 2, 3, 5 and 7th day. SDr of the left kidney on 1, 2, 3, 5 and 7th day were $412.18{\pm}86.69$, $352.14{\pm}47.05$, $399.77{\pm}65.54$, $369.43{\pm}48.34$ and $365.57{\pm}22.46$, respectively(p<0.05). In the study group, RI of the left kidney was more increased than that of the right kidney on 1, 2, 3, 5, 7 and 10th day. PI of the left kidney was more increased than that of the right kidney on 1, 3, 5, and 7th day. SDr of the left kidney was more increased than that of the right kidney on 1, 2, 3, 5 and 7th day(p<0.05). RI was effective in the diagnosis of an acute unilateral ureteral obstruction. PI and SDr were insufficient in the diagnosis of an acute unilateral ureteral obstruction.

  • PDF

Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water (음용수 중 수은 연속자동측정시스템의 개발에 관한 연구)

  • Chang, Soo-Hyun;Kim, Hyo-Jin;Kim, Sun-Tae;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.299-305
    • /
    • 1999
  • The electrolyte cathode atomic glow discharge (ELCAD) is a new plasma source for direct determination of trace heavy metals in drinking and waste water. ELCAD has been successfully developed for on-line monitoring of heavy metals, however, shows difficulty to measure mercury. In this study, ELCAD has been modified to apply the atomic absorption spectrometry (AAS) for the direct determination of trace elements of mercury in flowing water.The fundamental characteristics of this new types of plasma source have been investigated and found that the pH of the solution, discharge voltage, and current are most important factors.The absorbance of 1.0 ppm Hg standard solution increases as pH of the solution increases from pH 1.0 to 3.0.However, % RSD of the absorbance also increases as the pH of solution increasesdue to plasma unstability.The detection limits of the standard solution of pH 1.5 and pH 3.0 are about 40 ppb and 10 ppb level, respectively.

  • PDF

HPLC Analysis and Pharmacokinetics of KAL-1120, a Novel Anti-inflammation Agent, in Rats (흰쥐에서 항염증제 후보물질 KAL-1120의 HPLC 분석 및 약물동태)

  • Shin, Dae-Hwan;Lee, Jung-Yeol;Park, Seong-Hyeok;Lee, Gyeong-Bok;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of N-(-4-Chlorophenyl)-6-hydroxy-7-methoxy-2-chromanecarboxamide (KAL-1120), a novel anti-inflammation agent, in the rat plasma. The method was applied to analyze the compound in the biological fluids such as bile, urine and tissue homogenates. After liquid-liquid extraction, the compound was analyzed on an HPLC system with ultraviolet detection at 275 nm. HPLC was carried out using reversed-phase isocratic elution with a $C_{18}$ column, a mobile phase of a mixture of acetonitril (40 v/v%) at a flow rate of 1.0 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma was linear over the concentration range of 0.05-50 ${\mu}g$/mL. The intra- and inter-day assay accuracies of this method ranged from 0.06% to 9.33% of normal values and the precision did not exceed 6.28% of relative standard deviation. The plasma concentration of KAL-1120 decreased to below the quantifiable limit at 1.5 hr after the i.v. bolus administration of 2-10 mg/kg to rats ($t_{1/2,({\alpha})}$ and $t_{1/2,({\beta})$ of 2.15 and 26.7 min at a dose of 2 mg/kg, 3.91 and 33.0 min at a dose of 10 mg/kg, respectively). The steady-state volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) were not significantly altered in rats given doses from 2 to 10 mg/kg. Of the various tissues tested, KAL-1120 was mainly distributed in the lung and heart after i.v. bolus administration. KAL-1120 was detected in the bile by 30 min after its i.v. bolus administration. However, the concentration in the urine after i.v. bolus administration became too low to measure, suggesting that KAL-1120 is mostly excreted in the bile. In conclusion, this analytical method was suitable for the preclinical pharmacokinetic studies of KAL-1120 in rats.

Polycyclic Aromatic Hydrocarbons in Agricultural Waterways in Gyeonggi and Gangwon Provinces, Korea (경기 및 강원지역 농업용수 중 PAHs의 모니터링 연구)

  • Kim, Leesun;Park, Byung-Jun;Lee, Sung-Eun
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.3
    • /
    • pp.216-221
    • /
    • 2016
  • Level and distribution of fourteen polycyclic aromatic hydrocarbons (PAHs) in the agricultural water samples collected in the waterways located in Gyeonggi and Gangwon, Korea were determined for monitoring and risk assessment. A simplified, fast but effective extraction and clean-up methods combined with gas chromatography tandem mass spectrometry (GC-MS/MS) was employed to measure the concentration of the target compounds. The extraction of the analytes of interest in water sample (10 mL) was performed with acetonitrile (10 mL) and the salt. To purify the target PAHs, the clean-up procedure was employed with 2 mL tubes of dispersive solid phase extraction. The optimized method was validated with recoveries, method detection limit (MDL), accuracy and precision. Good recoveries for each PAHs at 10 and $25{\mu}g\;L^{-1}$ were achieved (60 to 110%, with RSD <20%) with linearity (>0.99). MDL for all the analytes was achieved with $0.2{\mu}g\;L^{-1}$. GC-MS/MS results showed that concentration of phenanthrene in the water samples from Gyeonggi (20 sites) ranged from 0.82 to $2.56{\mu}g\;L^{-1}$ and from Gangwon (15 sites) ranged from 0.83 to $1.62{\mu}g\;L^{-1}$. Other PAHs were not found in the water samples but the continuous monitoring for these areas were required.

Detection of M:N corresponding class group pairs between two spatial datasets with agglomerative hierarchical clustering (응집 계층 군집화 기법을 이용한 이종 공간정보의 M:N 대응 클래스 군집 쌍 탐색)

  • Huh, Yong;Kim, Jung-Ok;Yu, Ki-Yun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.125-134
    • /
    • 2012
  • In this paper, we propose a method to analyze M:N corresponding relations in semantic matching, especially focusing on feature class matching. Similarities between any class pairs are measured by spatial objects which coexist in the class pairs, and corresponding classes are obtained by clustering with these pairwise similarities. We applied a graph embedding method, which constructs a global configuration of each class in a low-dimensional Euclidean space while preserving the above pairwise similarities, so that the distances between the embedded classes are proportional to the overall degree of similarity on the edge paths in the graph. Thus, the clustering problem could be solved by employing a general clustering algorithm with the embedded coordinates. We applied the proposed method to polygon object layers in a topographic map and land parcel categories in a cadastral map of Suwon area and evaluated the results. F-measures of the detected class pairs were analyzed to validate the results. And some class pairs which would not detected by analysis on nominal class names were detected by the proposed method.

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (2) - Evaluation for Precision of System - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (2) -시스템의 정도 평가 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.318-325
    • /
    • 2003
  • The new biotelemetry method and system that the installation and the treatment of equipment is convenient and the instantaneously detailed position of the fish attached the pinger is able to track comparatively easily had been developed, an availabilities of it were verified in water tank by using hydrophone and pinger. First of all, the receiving system for biotelemetry was calibrated so as to measure tracking of high precision or wide detection range. In the next place, the precision at narrow and wide beam array of receiving system by using hydrophone was investigated and the actual position was compared with measured hydrophone position. The mean standard deviations of the position by narrow beam array of receiving system were 6.4em in phase beam of fore-aft pair and 6.3em in starboard-port pair, and the wide beam array were 24em and 23em respectively. The precision of distance, position, and velocity at narrow beam array of receiving system by using pinger were investigated and the actual values were compared with measured values. The distance from receiving system to pinger was measured by the pinger synchronizing method, angle of direction of pinger was detected by the super short base line (SSBL) method. The three dimensional position of pinger to the receiving system was measured by combining of two kinds of methods (SPB method), the velocity of pinger was obtained with a differential of the three dimensional positions. The mean standard deviations of the distance by pinger synchronizing method in narrow beam array of receiving system was 1. 8 em, that of the position by SPB method was 7.7cm.

Detection and Typing of Human Papillomavirus in Cutaneous Common Warts by Multiplex Polymerase Chain Reaction (Multiplex PCR 기법을 이용한 보통사마귀 내 인유두종바이러스 검출 및 분류)

  • Choi, Soon-Yong;Lim, Jong-Ho;Kim, Eun-Jung;Kim, Hei-Sung;Kim, Beom-Joon;Kang, Hoon;Park, Young-Min
    • Journal of Life Science
    • /
    • v.21 no.7
    • /
    • pp.947-952
    • /
    • 2011
  • A number of epidemiological studies have identified human papillomavirus (HPV) types 1, 2, 3, 4, 7, 10, 27, 57, and 65 in cutaneous common warts. However, identification of the HPV subtype by conventional polymerase chain reaction (PCR) is time consuming with its multi-step laboratory process. In this study, we aim to develop a specific one-step multiplex polymerase chain reaction method which capably identifies six different HPV genotypes related to common warts. By HPV DNA sequence analysis, 6 pairs of specific primers were designed from the intergenic regions of genes L1 to E6, and from genes E2 to L2. DNA sequence analysis with the L1 gene sequence of the sample was performed to measure the specificity of multiplex PCR. HPV-1, -2, -3, -4, -27, and -57 were identified without cross amplification in 109 out of 129 samples. The sensitivity and specificity of our set of primers in detecting HPV were 85% and 99.5%, respectively. For the 20 samples where HPV type was not identifiable by our batch of primer sets, multiplex PCR with an additional set of HPV primers was done, where 7 were found positive for HPV-7 or -65. Our results demonstrate that the newly designed multiplex PCR can rapidly detect the specific HPV subtype involved in common warts with high accuracy.

The Review of Exposure Index in Digital Radiography and Image Quality (디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구)

  • Yang, Sook;Han, Jae Bok;Choi, Nam Gil;Lee, Seong Gil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

Detection of Water Cloud Microphysical Properties Using Multi-scattering Polarization Lidar

  • Xie, Jiaming;Huang, Xingyou;Bu, Lingbing;Zhang, Hengheng;Mustafa, Farhan;Chu, Chenxi
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.174-185
    • /
    • 2020
  • Multiscattering occurs when a laser transmits into dense atmosphere targets (e.g. fogs, smoke or clouds), which can cause depolarization effects even though the scattering particles are spherical. In addition, multiscattering effects have additional information about microphysical properties of scatterers. Thus, multiscattering can be utilized to study the microphysical properties of the liquid water cloud. In this paper, a Monte Carlo method was used to simulate multi-scattering transmission properties of Lidar signals in the cloud. The results showed the slope of the degree of linear polarization (SLDLP) can be used to invert the extinction coefficient, and then the cloud effective size (CES) and the liquid water content (LWC) may be easily obtained by using the extinction coefficient and saturation of the degree of linear polarization (SADLP). Based on calculation results, a microphysical properties inversion method for a liquid cloud was presented. An innovative multiscattering polarization Lidar (MSPL) system was constructed to measure the LWC and CES of the liquid cloud, and a new method based on the polarization splitting ratio of the Polarization Beam Splitter (PBS) was developed to calibrate the polarization channels of MSPL. By analyzing the typical observation data of MSPL observation in the northern suburbs of Nanjing, China, the LWC and CES of the liquid water cloud were obtained. Comparisons between the results from the MSPL, MODIS and the Microwave radar data showed that, the microphysical properties of liquid cloud could be retrieved by combining our MSPL and the inversion method.

Distance measurement System from detected objects within Kinect depth sensor's field of view and its applications (키넥트 깊이 측정 센서의 가시 범위 내 감지된 사물의 거리 측정 시스템과 그 응용분야)

  • Niyonsaba, Eric;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.279-282
    • /
    • 2017
  • Kinect depth sensor, a depth camera developed by Microsoft as a natural user interface for game appeared as a very useful tool in computer vision field. In this paper, due to kinect's depth sensor and its high frame rate, we developed a distance measurement system using Kinect camera to test it for unmanned vehicles which need vision systems to perceive the surrounding environment like human do in order to detect objects in their path. Therefore, kinect depth sensor is used to detect objects in its field of view and enhance the distance measurement system from objects to the vision sensor. Detected object is identified in accuracy way to determine if it is a real object or a pixel nose to reduce the processing time by ignoring pixels which are not a part of a real object. Using depth segmentation techniques along with Open CV library for image processing, we can identify present objects within Kinect camera's field of view and measure the distance from them to the sensor. Tests show promising results that this system can be used as well for autonomous vehicles equipped with low-cost range sensor, Kinect camera, for further processing depending on the application type when they reach a certain distance far from detected objects.

  • PDF