• Title/Summary/Keyword: detection circuit

Search Result 698, Processing Time 0.023 seconds

Study on the Resistivity Leakage Current Detection and Properties Analysis of Electrical Installat ion (전기설비의 저항성 누설전류 검출 및 특성 해석에 관한 연구)

  • Choi, Chung-Seog;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.301-304
    • /
    • 2008
  • In this paper, we study from of flowing leakage current in electrical installation. Leakage current is expressed by a resistivity leakage current($I_{gr}$), a capacitive leakage current($I_{gc}$), an inductivity leakage current($I_{gl}$). General Zero Phase Current Transformer (ZCT) detect a leakage current($I_{g}$) that are conjoined resistivity leakage current and capacitive leakage current. In case $I_{gr}$ is big than $I_{gc}$, there is no singular problem in leakage current detection of system. But, in case $I_{gc}$ is big than $I_{gr}$, earth leakage breaker can not prevent accident effectively. Can lower electric leakage perception current to 5 mA if apply resistivity leakage current detecting circuit. We can achieve prevention of electricity disaster spontaneously.

  • PDF

The methods of error detection at Digital circuit using the FPGA 2-dimensional array (FPGA 2차원 배열을 사용한 디지털 회로에서 오류 검출의 방법)

  • Kim, Soke-Hwan;Hur, Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1306-1311
    • /
    • 2012
  • In this paper, we proposed on the direction of self-repairing mimicking the cell on the digital system design. Three-dimensional array of cells rather than using the original structure of FPGA, an array of blocks for efficient error detection methods were investigated. With a certain regularity, so the design method in detail by dividing the full array. The digital circuits can be detected fault location easily and quickly.

Touch Position Recovery Algorithm for Differential Sensing Touch Screen

  • Kim, Ji-Ho;Won, Dong-Min;Kim, HyungWon
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.2
    • /
    • pp.106-114
    • /
    • 2016
  • Differential sensing methods are more effective in alleviating panel noise than single-line sensing, and thus have been increasingly used in the touch screen industry. However, they have a drawback: they tend to cancel out multiple touches and need touch position recovery algorithms. This paper introduces a novel algorithm of touch position recovery for differential sensing, which is a low-complexity but high-accuracy approach for determining multiple touch positions. We have implemented the proposed method in a touch screen controller system on a chip. In the simulation experiments using realistic touch screen models and a differential sensing circuit, the algorithm exhibited a high detection performance of a signal-to-noise ratio gain of up to 52.21 dB. Therefore, we can conclude that the proposed method is substantially more accurate than the previous method. Further, the proposed method incurs little or no overhead in terms of the detection speed and the chip size.

A Neural Network Modulars for Real-time Detection of Bad Materials (불량소자의 검지를 위한 실시간 전송 뉴로 모률라)

  • Kim, Jong-Man;Kim, Won-Sop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.54-57
    • /
    • 2008
  • A new modular Lateral Information Propagation Networks can be implemented in a IC chip with the circuit VLSI technology for detection of bad materials. The proposed modular architecture is propagated the neural network through inter module connections. For such inter module connections, the host(computer or logic) mediates the exchange of information among modules. Also border nodes in each module have capacitors for temporarily retaining the information from outer modules. For detecting of Faulty Insulator, $4\;{\times}\;4$ neural network modules has been designed and simulation of interpolation with the designed networks has been done.

  • PDF

Study of DCM Interleaved Boost PFC Converter without the Detection of the Inductor Current (인덕터 전류검출이 필요없는 불연속모드 인터리브드 PFC 부스트 컨버터의 연구)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.303-308
    • /
    • 2016
  • A light-emitting diode (LED) has been increasingly applied to various industrial fields and general lightings because of its high efficiency, low power consumption, environment-friendly characteristic and long lifetime. To drive this LED lighting, various types of power converters have been applied. Also, power factor correction (PFC) techniques play an important role in the power supply technology. In this paper, design and control of a DCM interleaved boost PFC converter is discussed. The proposed converter can reduce current ripples at input and output side by cancelling an each phase of inductor currents. Since the IC does not require the auxiliary winding of inductor for current detection, simple PFC circuit is achieved. Therefore, it contributes to increase efficiency and downsize the whole system volume, cost. Also, the performance of the proposed system is demonstrated through experiments.

A study on Voltage Sag Detection of Power Quality Compensator (전력품질 보상장치의 순간전압강하에 관한 연구)

  • Lee jae-young;Lee won-sun;Han Woon-Dong;Jeon hee-jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.760-763
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic, and medical devices sensitive to power quality has caused many power quality problems and power supply-and-demand problem. Recently, in power system not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer), UPS, and APF are being studied more and more. Hence, in this paper, Voltage sag detection algorithm for voltage sag corrector is proposed. Also, simple circuit for the experimental voltage sag is Introduced.

  • PDF

Operation Detection of CRDMs in nuclear power plants by using the least square method (최소제곱법을 이용한 원자력발전소 제어봉구동장치의 동작 검출)

  • Kim, Seog-Joo;Kim, Chun-Kyung;Lee, Jong-Moo;Kwon, Soon-Man;Cheon, Jong-Min
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2301-2303
    • /
    • 2004
  • This paper proposes a detection method for mechanically stuck control rod drive mechanisms (CRDMs) in the nuclear reactor. From an electrical viewpoint, a coil of an electro-mechanical CRDM is modelled as an R-L circuit with time-varying inductance. The inductance of the coil is estimated from the measured voltage and current by using the least square method. Numerical experiments are carried out to illustrate the proposed method.

  • PDF

Efficient robust path delay fault test generation for combinational circuits using the testability measure (테스트 용이도를 이용한 조합회로의 효율적인 로보스트 경로 지연 고장 테스트 생성)

  • 허용민;임인칠
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.2
    • /
    • pp.205-216
    • /
    • 1996
  • In this paper we propose an efficient robust path delay fault test genration algorithm for detection of path delay faluts in combinational ligic circuits. In the proposed robust test genration approach, the testability measure is computed for all gates in the circuit under test and these computed values are used to genrate weighted random delay test vetors for detection of path delay faults. For genrated robust test vectors, we perform fault simulation on ISCAS '85 benchmark circuits using parallel pattern technqieus. The results indicate that the proposed test genration method not only increases the number of detected robust path delay faults but also reduces the time taen to genrate robust tests.

  • PDF

Train Tracking System Using Phase Difference of Arrival (도달 위상차를 이용한 열차 위치 추적)

  • Chung Sang-ki;Cho Hong-Shik;Kim Yeon-Su;Jeong Rag-Gyo
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.3
    • /
    • pp.244-252
    • /
    • 2005
  • Accurate and reliable tracking of train is essential for a train control system. The fixed block system which utilizes the track circuit has been used widely for detecting train position. As an alternative, the moving block system has the advantage over the fixed block system since it enables shorter headway and easier maintenance. This paper presents a new technique for the train tracking system which uses radio signal for the train position detection. The proposed algorithm uses the phase difference of arrival of radio signal for the detection of train position. Experimental verification of the algorithm is presented in the paper.

Development of improved image processing algorithms for an automated inspection system using line scan cameras (Line scan camera를 이용한 검사 시스템에서의 새로운 영상 처리 알고리즘)

  • Jang, Dong-Sik;Lee, Man-Hee;Bou, Chang-Wan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.4
    • /
    • pp.406-414
    • /
    • 1997
  • A real-time inspection system is developed using line scan cameras. Several improved algorithms are proposed for real-time detection of defects in this automated inspection system. The major improved algorithms include the preprocessing, the threshold decision, and the clustering algorithms. The preprocessing algorithms are for exact binarization and the threshold decision algorithm is for fast detection of defects in 1-D binary images. The clustering algorithm is also developed for fast classifying of the defects. The system is applied to PCBs(Printed Circuit Boards) inspection. The typical defects in PCBs are pits, dent, wrinkle, scratch, and black spots. The results show that most defects are detected and classified successfully.

  • PDF