• Title/Summary/Keyword: desulfurization

Search Result 353, Processing Time 0.028 seconds

A Study on the Removal of Hydrogen Sulfide by the Manganese Based Sorbents (망만계 탈황제에 의한 황화수소 제거에 관한 연구)

  • 손병현;최성원;김영식;정종현;조상원;오광중
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 1996
  • Experiments have been made to test the practical feasibility of using calcined manganese ore to desulfurize hot reducing gas. In this study, the effects of particle size of sorbents, temperature of sulfidation, flow rate and sorbent characteristics on the $H_2S$ removal efficiency of calcined manganese ore were investigated. Experimental results showed that the removal efficiency of $H_2S$ was optimum when the temperature was about 800$\circ$C and that the smaller particle size the higher the $H_2S$ removal efficiency. When the temperature was above 800$\circ$C, the reactivity of sorbent has lowered because agglomeration of sorbent increased intraparticle transport resistance, and this phenomenon was confirmed by SEM photographs. As the temperature increases, capacity for the $H_2S$ removal was increased but the equilibrium concentration of $H_2S$ was not affective.

  • PDF

Characteristic evaluation of anaerobic co-digestion using desulfurization sludge and primary sludge (탈황슬러지 및 생슬러지를 이용한 혐기성 병합소화 특성평가)

  • Seulki Koo;Woojin Chung;Soonwoong Chang;Myoungsoo Park
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.4
    • /
    • pp.51-58
    • /
    • 2023
  • In this study, anaerobic co-digestion was carried out using desulfurization sludge and sewage sludge (primary sludge) to evaluate the effects of sulfur compounds in anaerobic digestion. The experiment was carried out in the form of a batch test using 500 mL duran bottle, and the mixing ratio of the feedstock was selected based on the ratio of COD/SO4. As a result of the experiment, it was confirmed that the amount of biogas generated and the yield decreased at the mixing ratio of COD/SO4 20 or less. In particular, below COD/SO4 10, it was lower than seed (283.5 mL) which was set without feedstock to correct biogas generated by itself from seed sludge. Methane yield tended to decrease from a ratio of COD/SO4 20 or less to 0.135 m3/kg VS compared to 0.396 m3/kg VS of COD/SO4 50. In addition, compared to 0.0097 m3/kg VS of hydrogen sulfide yield from COD/SO4 50, the ratio of COD/SO4 20 increased sharply to 0.0223 m3/kg VS, and in particular, the highest result was 0.0855 m3/kg VS in COD/SO4 10. Based on these results, it is judged that the effect of sulfide in anaerobic digestion can have an adverse effect if the COD/SO4 ratio decreases to less than 20.

The Effect of Fluidized-Bed Variables on Attrition of Solid Particles (유동층 공정변수의 고체입자 마모에 미치는 영향)

  • Moon, Young-Sub;Yi, Chang-Keun;Son, Jae-Ek;Ryu, Chung-Keol;Choi, Jeong-Hoo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.603-608
    • /
    • 2005
  • This study was conducted to investigate particle attrition characteristics in a gas desulfurization using zinc titanate sorbent in a 0.035 m i.d. by 1.34 m height gas fluidized bed reactor. Gas jetting from the distributor and bubbling in the gas fluidized bed were found to be the main causes of particle attrition. The experiment was carried out under a slow attrition rate condition to compare the performance of the batch reactor to that of a continuous reactor. The attrition index (AI) and corrected attrition index (CAI) were measured at various the gas velocity, temperature, pressure, and bed weight, in the gas fluidized bed, during the dexulfurization process. The AI (5) and CAI (5) decreased as the bed weight increased. Particle destruction occurred when the particles started to experience physical fatigue under specific impacts over several iterations. AI (5) and CAI (5) also increased as relative humidity, gas velocity and pressure increased, and as temperature decreased. Particle attrition was mainly affected by gas jetting from the distributor, and abrasion resulted in smaller particles than fragmentation did.

Development of the Advanced Manganese-Based Sorbent for Hot Coal Gas Desulfurization (고온 석탄 가스 탈황을 위한 개선된 망간계 탈황제 개발)

  • Shon, Byung-Hyun;Choi, Eun-Hwa;Cho, Ki-Chul;Jeon, Dae-Young;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.291-302
    • /
    • 2000
  • This experiments have been made to develop of manganese-based sorbent for the removal of hydrogen sulfide from hot coal gases. Manganese-based sorbent were tested in an ambient-pressure fixed-bed reactor to determine steady state $H_2S$ concentrations, breakthrough times and feasibility of the sorbent when subjected to cycle sulfidation and regeneration testing. Effects of particle size of sorbent, temperature of sulfidation, regeneration temperature and regeneration characteristics on the $H_2S$ removal efficiency were investigated. Experimental results showed that the $H_2S$ removal efficiency was optimal when the temperature was about $800^{\circ}C$ and the smaller particle size, the better $H_2S$ removal efficiency but in the range of 0.214~0.631mm didn't influence it much. The equilibrium constant(K) is represented as a log(K)=3.396/T-1.1105 and the utilization efficiency of sorbents was about 92% at $800^{\circ}C$. Regeneration in air produced $SO_2$ concentration as high as 8.5% at $800^{\circ}C$, 8.4% at $850^{\circ}C$, and 8.8% at $900^{\circ}C$ and may be used in sulfuric acid production.

  • PDF

Investigation of Plume Opacity Induced by the Combustion of Orimulsion (오리멀젼 연소로 인한 가시백연의 원인 규명)

  • Kim, Young-Hun;Kim, Jong-Ho;Joo, Ji-Bong;Lee, Jeong-Jin;Kim, Jin-Soo;Kwak, Byung-Kyu;Jeong, Jin-Heun;Park, Soong-Keun;Yi, Jong-Heop
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.297-303
    • /
    • 2007
  • Orimulsion, a bitumen-in-water emulsified fuel, has been used throughout the world as a substitute fuel for heavy oil and coal. Orimulsion has relatively high levels of sulfur, nickel, and vanadium, compared to other fuel oils and coals, and has been the subject of much debate regarding the environmental impacts. In Korea, Y power plant has operated boilers with Orimulsion as a fuel, and they has some drawbacks during the plant operation, such as plume opacity. In this study, we investigated the cause of formation mechanism and factors for the plume opacity by investigating the operation data, and measuring the particle size distribution at EP(Electrostatic Precipitator), FGD(Fuel Gas Desulfurization) and TMS(Telecommunications Management System) units. Resulting data showed the primary particles below 1 ${\mu}m$ formed were regrown by the recombination of $SO_3$ in wet-limestone FGD process, and thus the secondary particles are induced to cause the plume opacity.

Microbial Desulfurization of a Bituminous Coal by Iron-Oxidizing Bacteria Thiobacillus ferooxidans (철산화 박테리아 Thiobacillus ferrooxidans에 의한 역청탄의 생물학적 탈황)

  • 류희욱
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.238-245
    • /
    • 1996
  • Microbial desulfurization characterlstics of a bituminous coal have been determined by using Thiobacillus ferrooxidans. The effects of process variables (such as coal pulp density, particle size and addition of surfactants) on pyrite removal have been investigated in both shake and airlift-bioreactor culture experiments. In shake experiments, pyrite could be removed over 78% for pulp densifies below 20% (w/v) and removed below 40% for pulp densities over 30% (w/v) in 8 days. Pyrite removal decreased with increasing pulp densities, and it also decreased sharply with increasing particle sizes. In airlift bioreactor experiments, pyrite at 50% (w/v) pulp density could be removed about 50%. Its value is much higher than 15% at the same pulp density in a shake experiment. With addition of surfactants, pyrite removal was enhanced in shake experiments significantly, whereas it was slightly decreased in an airlift bioreactor experiment.

  • PDF

Study on Calcination Characteristics of Limestones for In-Furnace Desulfurization in Oxy-Fuel Combustion (순산소연소 조건에서 석회석의 소성특성 및 로내탈황에 관한 연구)

  • An, Young-Mo;Jo, Hang-Dae;Choi, Won-kil;Park, Yeong-Sung;Keel, Sang-In;Lee, Hyung-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.371-377
    • /
    • 2009
  • In oxy-fuel combustion, $CO_2$ concentration in the flue gas may be enriched up to 95% owing to the gas recirculation. Under the high $CO_2$ concentration, the calcination characteristic of limestone is different from that of the conventional air combustion system. In this study, three types of limestone taken from different regions in Korea were used as $SO_2$ absorbent and their calcination characteristics depending on calcination temperature were investigated. The experiments were performed to examine the effects of operating variables such as absorbent species, reaction temperatures on the $SO_2$ removal efficiency and reacted limestone particles were captured to examine the sulfur contents. The degree of calcination and the specific surface area increased with calcination temperature and $SO_2$ removal efficiency increased with reaction temperature. The results showed remarkable difference in $SO_2$ removal efficiencies between the limestone types. The sulfur content of the reacted limestone with the highest $SO_2$ removal efficiency was about 10%.

CFD Analysis on the Effect of the Nozzle Arrays and Spray Types in the Hydrogen Peroxide Mixing Quencher to Improve the Mixing Efficiency (과산화수소 혼합냉각기 내의 노즐배치 및 가스분사 방식 변화에 따른 혼합율 개선에 대한 전산해석적 연구)

  • Koo, Seongmo;Chang, Hyuksang
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.42-53
    • /
    • 2017
  • Numerical analysis was done to evaluate the fluid distribution inside of the mixing quencher to increase the reaction efficiency of the aqueous hydrogen peroxide solution in the scrubbing column which is used for simultaneous desulfurization and denitrification. Effective injection of the aqueous hydrogen peroxide ($H_2O_2$) solution in the mixing quencher has major effects for improving the reaction efficiency in the scrubbing column by enhancing the mixing of the aqueous $H_2O_2$ solution with the exhaust gas. The current study is to optimize the array of nozzles and the spray angles of the aqueous $H_2O_2$ solution in the mixing quencher by using the computational method. Main concerns of the analysis are how to enhance the uniformity of the $H_2O_2$ concentration distribution in the internal flow. Numerical analysis was done to check the distribution of the internal flow in the mixing quencher in terms of RMS values of the $H_2O_2$ concentration at the end of quencher. The concentration distribution of $H_2O_2$ at the end of is evaluated with respect to the different array of the nozzle pipes and the nozzle tip angles, and we also analyzed the turbulence formation and fluid mixing in the zone. The effect of the spray angle was evaluated with respect to the mixing efficiency in different flow directions. The optimized mixing quencher had the nozzle array at location of 0.3 m from the inlet duct surface and the spray angle is $15^{\circ}$ with the co-current flow. The RMS value of the $H_2O_2$ concentration at the end of the mixing quencher was 12.4%.

Analysis of cause of engine failure during power generation using biogas in sewage treatment plant (하수처리장 바이오가스를 이용한 발전시 가스엔진의 고장원인 분석)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.13-29
    • /
    • 2016
  • In this study, we analyzed the causes of major faults in the biogas plant through the case of gas engine failure when cogenerating electricity and heat using biogas as a fuel in the actual sewage treatment plant and suggested countermeasures. Hydrogen sulfide in the biogas entering the biogas engine and water caused by intermittent malfunction of the water removal system caused intercooler corrosion in the biogas engine. In addition, the siloxane in the biogas forms a silicate compound with silicon dioxide, which causes scratches and wear of the piston surface and the inner wall of the cylinder liner. The substances attached to the combustion chamber and the exhaust system were analyzed to be combined with hydrogen sulfide and other impurities. It is believed that hydrogen sulfide was supplied to the desulfurization plant for a long period of time because of the high content of hydrogen sulfide (more than 50ppm) in the biogas and the hydrogen sulfide was introduced into the engine due to the decrease of the removal efficiency due to the breakthrough point of the activated carbon in the desulfurization plant. In addition, the hydrogen sulfide degrades the function of the activated carbon for siloxane removal of the adsorption column, which is considered to be caused by the introduction of unremoved siloxane waste into the engine, resulting in various types of engine failure. Therefore, hydrogen sulfide, siloxane, and water can be regarded as the main causes of the failure of the biogas engine. Among them, hydrogen sulfide reacts with other materials causing failure and can be regarded as a substance having a great influence on the pretreatment process. As a result, optimization of $H_2S$ removal method seems to be an essential measure for stable operation of the biogas engine.

A Study on Optimization of Spray Type Flue Gas Desulfurization (FGD) System (모사 탈황흡수탑을 이용한 Spray Type 탈황설비 최적운전 방안에 관한 연구)

  • An, Hi-Soo;Park, Seung-Soo;Kim, Ki-Hyoung;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.29-35
    • /
    • 2007
  • Recently, due to narrow margin on design factor of flue gas desulfurization (FGD) systems or aging of systems, some problems such as decrease of $SO_2$ removal efficiency and difficulty on coping with unstable state are arising on FGD systems. On this study, to cope with these problems several methods such as adjustment of reagent pH, inlet $SO_2$ concentration, variation of units of operation pump, installation of liquid distribution ring (LDR) were attempted to increase the $SO_2$ removal using spray type simulated FGD system. Also, sulfite and Al/Fx ion effects on limestone blinding were experimented. When three absorber recirculation pumps were operated, $SO_2$ removal was increased by 12% in comparison with that of two pumps operation. $SO_2$ removal was increased by 2~7% after installation of LDR. Dissolved oxygen increased up to 0.5 ppm and limestone binding effect was alleviated after injection of dibasic acid (DBA) with the concentration of 500 and 1,000 ppm. When $Al^{3+}$ and $F^-$ ions were coexisting, the dissolution rate of limestone was decreased by 20%.