• 제목/요약/키워드: destructive tests

검색결과 253건 처리시간 0.031초

6.6 kV급 고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings)

  • 김희동;김병한
    • 한국전기전자재료학회논문지
    • /
    • 제19권11호
    • /
    • pp.1067-1071
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in ten high voltage motors. Diagnostic tests included polarization infer, ac current, dissipation factor$(tan{\delta})$ and partial discharge magnitude. The rewind of motet slater insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 8 motor failed near rated voltage of 19.0 kV. The breakdown voltage of No. 4 motet was 7.0 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

The Influence of Weathering Conditions on the Outer Membrane of Biogas with Plasticized PVC : A Study using Non-destructive Tests

  • Kim, Changhwan;Ki, Wootae;Kim, SangMyung;Shin, Jinyong
    • 한국표면공학회지
    • /
    • 제47권2호
    • /
    • pp.57-62
    • /
    • 2014
  • The biogas holder is composed of an outer membrane and an inner membrane which are subject to outdoor exposure and gas exposure respectively. The influence of weathering conditions on the photo-degradation of a biogas holder was investigated. Tests were performed under three different methods - outdoor exposure tests (Seosan, Arizona), accelerated tests (Xenon-are lamp) with the outer-membrane of biogas. Moreover, the changes in the aging process were monitored using color difference, gloss, the contact angle and an optical microscope. Changes in physical properties, such as decrease reduction in gloss, decrease in the contact angle, increase in color difference were observed in the aging process. The comparison between membrane 3B, 4B and membrane 5B under xenon-arc were discussed. Membrane 5B was very sensitive to ultraviolet (UV) ray. There were many difficulties in the outdoor exposure test due to acid rain, dust, and stain resistance.

고압전동기 고정자 권선의 절연열화 분석 (Analysis of Insulation Aging in High Voltage Motor Stator Windings)

  • 김희동;공태식;이영준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.200-203
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in eight high voltage motors. Diagnostic tests included polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 motor failed near rated voltage of 12.96 kV. The breakdown voltage of No. 4 motor was 6.99 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

  • PDF

노후화된 국내 콘크리트 교량에 적합한 비파괴 시험 결과의 평가 (Evaluation of Non-destructive Test Results for Existing Concrete Bridges in Korea)

  • 이학은;윤영수;백영인;이병철;김영민;정우용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.385-390
    • /
    • 1998
  • Non-destructive field tests of the concrete has achieved increasing acceptance for the evaluation of existing concrete structures. As two major testing methods, this paper recommends the proper empirical relationship between the rebound number together with the ultrasonic pulse velocity and the core strength to fit the old concrete bridges in Korea.

  • PDF

국내 콘크리트 교량에 적합한 비파괴 시험법 적용에 관한 연구 (A Study on the Application of Non-destructive Test for Concrete Bridges in Korea)

  • 이학은;윤영수;이병철;김영민;정우용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.737-742
    • /
    • 1998
  • Non-destructive field tests of the concrete has achieved increasing acceptance for the evaluation of existing concrete structures. But the application of this test has not still accomplished to guarantee perfectly the durability of the concrete bridges in Korea. As two major testing methods, this paper recommends the proper empirical relationship between the rebound number together with the ultrasonic pulse velocity and the core strength. Also, this paper recommend the relationships as the aging and as the element.

  • PDF

Guided wave analysis of air-coupled impact-echo in concrete slab

  • Choi, Hajin;Azari, Hoda
    • Computers and Concrete
    • /
    • 제20권3호
    • /
    • pp.257-262
    • /
    • 2017
  • This study aims to develop a signal processing scheme to accurately predict the thickness of concrete slab using air-coupled impact-echo. Air-coupled impact-echo has been applied to concrete non-destructive tests (NDT); however, it is often difficult to obtain thickness mode frequency due to noise components. Furthermore, apparent velocity in concrete is a usually unknown parameter in the field and the thickness of the concrete slab often cannot be accurately measured. This study proposes a signal processing scheme using guided wave analysis, wherein dispersion curves are drawn in both frequency-wave number (f-k) and phase velocity-frequency ($V_{cp}-f$) domains. The theoretical and experimental results demonstrate that thickness mode frequency and apparent velocity in concrete are clearly obtained from the f-k and $V_{cp}-f$ domains, respectively. The proposed method has great potential with regard to the application of air-coupled impact-echo in the field.

플라이애쉬를 혼입한 현장타설 매스콘크리트의 압축강도 추정에 관한 실험적 연구 (An Experimental Study on Prediction of Compressive Strength of the In situ Mass Concrete with Fly-ash)

  • 길배수;채영석;남재현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권1호
    • /
    • pp.163-169
    • /
    • 1999
  • The object of this study is to compare properties of massive fly-ash concrete with plain concrete. Two concrete mixtures comprising two batch each $1.0m^3$ in volume, were made from ready mixed concrete batch plant. The water-to-cementitious materials ratio was kept constant at 51.4%. Therefore, massive concrete specimen($W800{\times}D800{\times}H800mm$) was cast from ready mixed concrete to analyze history of temperature and core strength properties. Bleeding, time of slump loss and time of setting of the fresh concrete were measured. In order to estimate the properties of massive fly-ash concrete in hardened concrete, non-destructive tests such as rebound hardness, ultrasonic pulse velocity and maturity were performed and analyzed.

  • PDF

Exploring Graphically and Statistically the Reliability of Medium Density Fiberboard

  • Guess, Frank M.;Edwards, David J.;Pickrell, Timothy M.;Young, Timothy M.
    • International Journal of Reliability and Applications
    • /
    • 제4권4호
    • /
    • pp.157-170
    • /
    • 2003
  • In this paper we apply statistical reliability tools to manage and seek improvements in the strengths of medium density fiberboard (MDF). As a part of the MDF manufacturing process, the product undergoes destructive testing at various intervals to determine compliance with customer′s specifications. Workers perform these tests over sampled cross sections of the MDF panel to measure the internal bond (IB) in pounds per square inches until failure. We explore both graphically and statistically this "pressure-to-failure" of MDF. Also, we briefly comment on reducing sources of variability in the IB of MDF.

  • PDF

고압회전기 절연진단 주기 설정에 관한 연구 (A Study on the Establishment of Insulation Diagnosis Cycle for High Voltage Rotating Machine)

  • 이영준;김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1939-1941
    • /
    • 2000
  • Nondestructive and destructuve insulation tests were performed the high voltage rotating machine in the local thermal power plants. Nondestructive tests include measurements of insulation resistance. polarization index, AC current. tan$\delta$, partial discharge. Destructive tests include measurements of AC hipot and DC hipot. This paper propose to establish the insulation diagnosis cycle for high voltage rotating machine.

  • PDF

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.