• 제목/요약/키워드: design value engineering

검색결과 3,289건 처리시간 0.035초

평행식 진동탄환 암거 천공기의 연구 (IV)(V)-실기 설계 제작 및 보장실험-Development of Balanced-Type Oscillating Mole Drainer(IV)(V)

  • 김용환;이승규;서상용
    • Journal of Biosystems Engineering
    • /
    • 제2권1호
    • /
    • pp.7-24
    • /
    • 1977
  • This paper is the forth and fifth one of the study on balanced type oscillating mole drainer. In the light of the results from previous reports about the model tests, some design criteria were established and a prototype machine was set up for experimental purpose. Motion characteristics and functionof the each parts of the machine were checked and analyzed. After that, performance tests of the prototype machine were carried out in thefield. Obtained results are summarized as follows ; 1. Ten centimeter of the bullet diameter was determined so as to be able to attach it to the tractors with capacity of 30 PS to 40 PS. 2. To maintain the balance between the moments of the front shank and rear shank, the oscillating amplitude of the rear bullet was determined to be larger than that of the front bullet. At the same time , the oscillating direction of the rear bullet was designed with the inclines of ten to thirty degrees. 3. An octagonal dynamo transduced was developed for measuring the compressive force of the upper link is measuring the draft force of the machine. Acceptable linear relationship between forces and strain responses from O.D.T. was obtained. 4. Analysing the balancing mechanism of the acting part of the machine , it was found that the total draft force of the machine was equal to the difference between the sum of the draft force produced from the right and left side bending moments of the lower drawber and the compressive force on the upper link. 5. There are acceptable linear relationship between the strain and twisting moment by driving shaft, and between strain and shank moment. Above results enable us to carry out the field experiment with prototype machine. 6. When the test machine was used in the field, it was possible to reduce the oscillating acceleration by forty percent in average as compared it with the single bullet mole drainer. 7. When the test machine was used under the oscillating condition, the dratt torce was reduced by 27 percent to 59 percent as compared it with the test machine under non-oscillating condition, while the draft force was increased by 7 percent to 20 percent as compared it with the mole drainer having oscillating single bullet. The reasoning behind this fact was considered as the resistance force due to the rear shank and bullet. 8. As the amplitude and frequency of the bullet were increased, the torque was increased accordingly. This tendency could be varied with the various characteristics of the given soils. And the larger frequency and amplitute, the more increasing oscil\ulcornerlating power but decreasing draft brce were needed, and draft force was increased as the velocity was increased.9. When the amplitude of the rear bullet was designed to be larger than that of the front bullet, the minimum value of the moment was lowered and oscillating acceleration was reduced. And when the oscillating direction of the rear bullet was declined back\ulcornerwards, oscillating acceleration was increased along with the increasing angle of decli\ulcornernation. When the test machine was operated in high speed, the difference between maximum moments and minimum ones became narrow. This varying magnitude of moments appeared on the moment oscillogram seems to be correlated to the oscillating acceleration and draft force. 10. From the analysis of variance, it was found that those factors such as frequency, amplitude, and operating velocity significantly affected in the oscillating acceleration, the draft resistance, the torque, the moment, and the total power required. And interaction between frequency and amplitude affected in the oscillating acceleration. 11. Within the given situation of this study, the most preferable operating conditions of the test machine were 7 Hz in oscillating frequency, 0.54 m/sec in operating velocity, and 39.1 mm in oscillating amplitude of front and rear bullets. However, it is necessary to select the proper frequency and magnitude of oscillation depending on the soil properties of the field in which the mole drainer is practiced by use of a bal1nced type oscillating mole drainer. 12. It is recommended that a comparative study of the mole drainers would be performed in the near future using two separate balanced oscillating bullet with the one which is operated by oscillating the movable bullet in a single cylinder or other balanced type which may be single oscillating bullet with spring, damper or balancing weight, and that of thing. To expand the applicability of the balanced type oscillating mole drainer in practical use, it is suggested to develop a new mechanism which perform mole drain with vinyl pipe or filling material such as rice hull.

  • PDF

멸종위기종 붉은점모시나비의 대체서식지 위치 선정 - 경북 의성군 안사면 일원에서 - (Evaluation of Alternative Habitat Patches for the Endangered Parnassius bremer (Lepidoptera: Papilionidae) in Korea - Evaluation of Ansa-myeon, Uiseong-gun, Gyeongsangbuk-do, Korea -)

  • 김도성;권용정;김동혁;김창환;서민환;박성준;연명훈;이두범
    • 한국조경학회지
    • /
    • 제39권4호
    • /
    • pp.98-106
    • /
    • 2011
  • 최근 멸종위기 종에 때한 보전, 복원프로그램은 세계적인 추세일 뿐만이 아니라 국내에서도 자연환경보전법으로 보호를 받고 있다. 본 연구는 국내에서 멸종 위기에 처해 있는 붉은점모시나비가 상주-영덕 고속도로 계획노선에 의하여 서식지의 일부를 관통하거나 인접하여 이 지역의 개체군을 대체서식지로의 이주가 결정되었다. 이에 대체서식지의 조성에 앞선 선행 작업으로 위치 선정을 위하여 Mark-Release-Recapture (MRR) 방법으로 가상이동모텔을 적용하여 패치의 연결성을 추정하고 개체생존이주율을 산출하여 대체서식지 위치선정의 평가 자료로 활용하였다. 그 결과, 붉은점모시나비는 패치간의 거리가 약 250m 이내의 범위에서 50% 이상의 연결성과 개체생존이주 가능성을 보였으며, 나비의 이동거리를 추정에서는 평균 300m로 나타났다. 그리고 나비의 분포특성에서는 인접한 여러 개의 서식지 패치를 개체들이 이주를 하면서 순환 발생하는 메타개체군을 이루고 있다. 대체서식지의 위치를 결정하기 위하여 연구 결과에 따른 지역, 해당 지역의 지방자치단체의 추천지역, 그리고 훼손지역의 가치를 상쇄할 수 있을 정도의 중요도가 있는 지역을 예비 선정하였다. 그리고 이 지역들을 나비의 생태, 생태기반환경, 관리방안, 위험요소, 시공요소를 평가를 한 결과, 의성군에서는 5 안(안사면사무소)이 관리방안에서 높은 점수를 얻어 선정되었다. 이번에 평가된 항목에서 나타난 바와 같이 대체서식지의 위치 선정에 있어서는 대체서식지 조성이 가능한 예산의 범위, 서식지 관리주체의 선정, 현지 주민과의 협의 등 여러 가지 문제를 복합적으로 고려하는 것이 높은 비중을 차지하였으며, 생물학, 생태학, 경관생태학, 생물지리학, 생태공학, 조경학, 인문학 등의 다양한 분야의 참여로 얻은 결과물을 융합하여 반영하는 것이 필요하다는 것을 제언하고자 한다.

지하연속벽용 병용계 고유동 콘크리트의 시공 품질 및 보증강도 평가에 관한 연구 (A Study on the Estimation for the Guaranteed Strength and Construction Quality of the Combined High Flowing Concrete in Slurry Wall)

  • 권영호
    • 콘크리트학회논문집
    • /
    • 제18권6호
    • /
    • pp.811-817
    • /
    • 2006
  • 본 연구에서는 지하식 LNG 저장탱크의 지하연속벽에 사용되는 병용계 고유동 콘크리트의 시공 품질 및 보증강도 평가를 정리한 것이다. 일반적으로 지하연속벽에 사용되는 고유동 콘크리트의 배합강도는 높은 할증계수와 낮은 수중 콘크리트의 저감계수를 적용하기 때문에, 매우 비경제적인 배합설계가 된다. 이를 구명하기 위한 방안으로 현장에서 실시한 병용계 고유동 콘크리트의 시공 품질과 보증강도를 평가하여 이에 적합한 배합강도 산정식을 제안하고자 하였다. 연구 결과, 최적배합조건은 물-시멘트비 51%, 잔골재율 48.8%, 그리고 석회석 미분말을 시멘트의 중량비로 42.6% 치환한 것으로 선정하였다. 또한, 현장 적용 결과를 분석해 보면, 슬럼프 플로우에 대한 시공 품질 시험 결과 평균 616~634mm이고 500mm 플로우 도달시간은 평균 6.3초, 공기량은 평균 4.0%로 관리기준을 만족하였다. 표준양생 공시체의 압축강도에 대한 시공 품질 시험 결과, 평균 49.9MPa를 나타내었고 표준편차는 1.66MPa, 변동계수는 3.36%로 매우 낮았다. 코어 공시체의 압축강도는 평균 66.4MPa를 나타내었고, 표준편차는 3.64Pa, 변동계수는 5.48%로 나타났다. 표준양생 공시체와 코어 공시체의 보증강도비는 1.23 및 1.32로 나타났다. 기존에 배합강도를 산정하기 위하여 적용한 할증계수 및 저감계수가 매우 안정적인 것으로 나타났다. 본 연구에서는 이러한 결과를 통해 지하연속벽에 사용되는 병용계 고유동 콘크리트의 배합강도 산정에 있어서 변동계수 7%, 할증계수 1.13 및 수중 콘크리트의 강도저감 계수를 0.98로 제안하였다.

파형강관을 이용한 지하매설물용 뒤채움재 설계 및 시공성 평가 (Evaluation of Construction Operation and Design Properties of CLSM for Corrugated Pipe in Underground)

  • 이관호;박재헌
    • 한국도로학회논문집
    • /
    • 제8권2호
    • /
    • pp.63-74
    • /
    • 2006
  • 원형지하매설관의 경우 관의 하단부의 다짐이 매우 어렵고, 또한 다짐효율이 떨어져서 지하매설물의 안정을 저감시키고, 이로 인해 각종 파손이 발생하는 문제점을 가지고 있다. 이러한 문제점을 해결할 수 있는 하나의 대안으로 저강도 콘크리트 개념을 지반공학에 적용하여 만들어진 유동성 채움재(CLSM)를 이용하는 것이다. 본 연구에서는 같은 조건에서 일반모래 뒤채움재 방식사를 이용한 유동성뒤채움재 및 현장발생토사를 이용한 유동성 뒤채움재 종류를 변화시킨 3가지 사례에 대한 PENTACON -3D 유한요소 프로그램을 이용하여 수치해석을 실시하였다. 또한 현장발생토사의 파형강관용 유동성 뒤채움재로서 현장 적용성을 평가하기 위하여 현장실험을 수행하였다. 현장시험 및 해석을 실시한 결과 뒤채움재로 유동성 채움재를 사용하는 경우에 일반모래를 사용한 경우보다 관의 수직 수평변위 및 지표면변위를 감소시키는 것으로 해석되었다. 이는 유동성 채움재의 특징 중 자기수평능력과 자기강도발현특성에 의해 양생이 진행됨에 따라 파형강관 주변의 유동성 채움재가 굳어 강성화되고,이것이 파형강관과의 일체화를 통한, 파형강관의 단면강도를 증진시켜준 효과로 해석할 수 있다. 그리고 뒤채움재의 종류에 따른 파형강관의 토압특성은 뒤채움재로 일반모래를 대체하여 유동성 채움재를 사용한 경우에 관에 작용하는 수직 수평토압이 거의 0에 가까운 값으로 현저히 작아짐을 알 수 있었다. 이는 현장발생토사 재활용 유동성 뒤채움재를 사용하는 것이 지하매설관에 발생하는 각종 파손을 감소시키고, 안정성을 높이는 하나의 대안으로 판단된다.타내었다.catenella 성장률도 감소하였다. A. catenella는 $10^{-3}\sim0.1{\mu}M$ 셀레니움 농도에서 A. catenella 세포밀도가 증가하고 대수성 장기 후반(the end of exponential phase)이 길어짐을 관찰 하였다. 경우 유의한 형태적 차이는 관찰되지 않았으나 당뇨군의 근위곱슬세관 분분에 세포 자연사가 중점적으로 발견되었다.사료로 전환하기에 적당하다고 할 수 있겠다.%로 향상된 결과를 얻을 수 있었다.하는 경향을 나타내었고, $30^{\circ}C$ 실험구의 경우에는 시간의 지남에 따라 유의적으로 활성이 낮아지는 경향을 나타내었다. HSP70 mRNA의 발현은 대조군($20^{\circ}C$)과 비교하여 $25^{\circ}C$ 48 h째 실험구를 제외한 모든 실험구에서 유의적으로 높게 발현되었다. 이상의 결과로, $20^{\circ}C$에서 순치된 시볼트전복은 급격한 수온 스트레스에 대해 많은 스트레스 요인으로 작용하는 것으로 나타났으며, 수온 스트레스에 대한 생리학적 방어 기작이 분자 레벨인 HSP70 mRNA에서는 신속히 발현되어 스트레스에 대처하지만, SOD나 CAT와 같은 항산화 효소의 발현은 다소 늦게 작용하는 것으로 나타났다. 그러나, 시간의 지남에 따라 $5^{\circ}C$ 내외의 스트레스와 저수온 스트레스의 경우에는 비교적 안정화되는 것으로 보여지며, $10^{\circ}C$

  • PDF

해양 플랑크톤 군집의 전기분해 염소소독 효과 (The Electrochemical Chlorination for Marine Plankton Community Disinfection)

  • 강정훈;신경순;현봉길;장민철;김은찬;장만
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제10권3호
    • /
    • pp.127-137
    • /
    • 2007
  • 전기분해 염소소독기로 처리한 결과가 국제해사기구의 협약에서 제시한 생물처리 기준(D-2 regulation)을 만족하는지 확인하기 위해 박테리아, 식물플랑크톤($10-50\;{\mu}m$) 및 동물플랑크톤($>50\;{\mu}m$)의 사멸효과를 확인하였다. 실험조건은 대조구와 잔류염소농도 10 ppm(Expt. 1)과 30 ppm(Expt. 2)을 실험구로 설정하였고, 시험수를 $23.8\;m^3/hr$의 속도로 전기분해염소독기에 통과시켰다. 시험수의 생물조건은 국제해사기구에서 작성된 선박 평형수 관리 장치의 승인을 위한 지침서에서 제시한 기준을 따랐다. 식물플랑크톤의 생사판별은 광학현미경, 형광현미경 및 형광측정기(Turner Designs 10-AU)를 이용하여 확인되었다. 두 농도 조건(10 ppm, 30 ppm)의 처리수에서 운동성이 있는 식물플랑크톤은 움직임이 나타나지 않았고, 형광현미경 하에서 엽록소 형광색이 적색에서 녹색으로 바뀌었으며, 형광값은 고농도(Expt. 1: 6.95, Expt. 2: 7.11)에서 0으로 바뀌었다. 이는 식물플랑크톤의 활성이 상실되어 모두 사멸되었음을 의미한다. 동물플랑크톤의 생사판별은 해부현미경하에서 부속지의 움직임을 토대로 결정되었다. 전기분해 염소소독기 처리 후 해양환경에서 채집되어 농축된 자연군집 동물플랑크톤은 모두 사멸되었으나, 일부 Artemia가 생존하였다. 그러나 각 잔류염소 농도조건의 암소에서 노출시킨 지 24시간 뒤에는 모든 동물플랑크톤이 사멸되었다. 박테리아는 Petrifilm plates($3M^{TM}$)를 이용한 접종배양법으로 처리수의 총 세균, 대장균 군 및 대장균의 사멸효과를 확인한 결과, 균주가 전혀 관찰되지 않았다. 또한 각 염소농도 조건의 처리수에서 추가적으로 노출시킨 5일 동안 세 그룹의 생물에서 재성장이 나타나지 않았다. 본 연구결과는 세 그룹의 생물에 대한 전기분해염소소독기 처리결과가 국제해사기구에서 제정한 선박 평형수 배출기준을 만족시켰음을 보여주었다.

  • PDF

Improving Corsican pine somatic embryo maturation: comparison of somatic and zygotic embryo morphology and germination

  • Wtpsk, Senarath;Shaw, D.S.;Lee, Kui-Jae;Lee, Wang-Hyu
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2003년도 춘계 학술발표대회
    • /
    • pp.61-62
    • /
    • 2003
  • Clonal propagation of high-value forest trees through somatic embryogenesis (SE) has the potential to rapidly capture the benefits of breeding or genetic engineering programs and to improve raw material uniformity and quality. A major barrier to the commercialization of this technology is the low quality of the resulting embryos. Several factors limit commercialization of SE for Corsican pine, including low initiation rates, low culture survival, culture decline causing low or no embryo production, and inability of somatic embryos to fully mature, resulting in low germination and reduced vigour of somatic seedlings. The objective was to develop a Corsican pine maturation medium that would produce cotyledonary embryos capable of germination. Treatments were arranged in a completely randomized design. Data were analyzed by analysis of variance, and significant differences between treatments determined by multiple range test at P=0.05. Corsican pine (Pinus nigra var. maritima) cultures were initiated on modified !P6 medium. Modifications of the same media were used for culture multiplication and maintenance. Embryogenic cultures were maintained on the same medium semi solidified with 2.5 g/l Gelrite. A maturation medium, capable of promoting the development of Corsican pine somatic embryos that can germinate, is a combination of iP6 modified salts, 2% maltose, 13% polyethylene glycol (PEG), 5 mg!l abscisic acid (ABA), and 2.5 g/l Gelrite. After initiation and once enough tissue developed they were grown in liquid medium. Embryogenic cell suspensions were established by adding 0.951.05 g of 10- to 14-day-old semisolid-grown embryogenic tissue to 9 ml of liquid maintenance media in a 250ml Erlenmeyer flask. Cultures were then incubated in the dark at 2022$^{\circ}$C and rotated at 120 rpm. After 2.53 months on maturation medium, somatic embryos were selected that exhibited normal embryo shape. Ten embryos were placed horizontally on 20 ml of either germination medium ($\frac{2}{1}$strength Murashige and Skoog (1962) salts with 2.5 g/l activated charcoal) or same medium with copper sulphate adjusted to 0.25 mg/1 to compensate for copper adsorption by activated carbon. 2% and 4% maltose was substituted by 7.5% and 13% PEG respectively to improve the yield of the embryos. Substitution of' maltose with PEG was clearly beneficial to embryo development. When 2% of the maltose was replaced with 7.5% PEG, many embryos developed to large bullet-shaped embryos. At latter stages of development most embryos callused and stopped development. A few short, barrel-shaped cotyledonary embryos formed that were covered by callus on the sides and base. When 4% of the maltose was removed and substituted with 13% PEG, the embryos developed further, emerging from the callus and increasing yield slightly. Microscopic examination of the cultures showed differing morphologies, varying from mostly single cells or clumps to well-formed somatic embryos that resembled early zygotic embryos only liquid cultures with organized early-stag. A procedure for converting and acclimating germinants to growth in soil and greenhouse conditions is also tested. Seedling conversion and growth were highly related to the quality of the germinant at the time of planting. Germinants with larger shoots, longer, straighter hypocotyls and longer roots performed best. When mature zygotic embryos germinate the root emerges, before or coincident with the shoot. In contrast, somatic embryos germinate in reverse sequence, with the cotyledons greening first, then shoot emergence and then, much later, if at all, the appearance of the root. Somatic seedlings, produced from the maturation medium, showed 100% survival when planted in a field setting. Somatic seedlings showed normal yearly growth relative to standard seedlings from natural seed.

  • PDF

파키스탄 Gulpur 수력발전 현장의 Best Practices 소개 (Introduction of the Best Practices in the Pakistan Gulpur HEPP)

  • 장옥재;홍원표;채희문
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.216-217
    • /
    • 2022
  • Gulpur 수력발전 프로젝트는 전력난을 겪고 있는 파키스탄에 102 MW 규모의 수력발전소를 건설하여 30년 동안 운영 관리한 후 파키스탄 정부로 양도하는 IPP(Independent Power Producing) 형식의 투자사업이다. 남동발전과 DL E&C, 롯데건설이 Sponsor로서 출자한 자본금과, ADB, IFC, K-EXIM 등의 대주단로부터의 차입금을 재원으로 하여 소요 사업비를 조달하고 사업을 개발하였다. DL E&C와 롯데건설이 EPC(Engineering, Procurement, Construction)를 수행하였고, 이산이 Design consultant의 역할을 수행하였다. Gulpur 수력발전 프로젝트의 발전형식은 수로식(run-of-river)으로 201 m3/s의 발전유량과 102 MW의 발전 시설용량을 이용하여 연평균예상발전량은 398 GWh이다. 주요 구조물로는 설계 재현빈도 1년의 유수전환시설(가물막이댐 & 가배수터널)과 콘크리트 중력식댐(H 67 m, L 205 m), 도수터널(D 6.7 m, L 215 m, 2기), 옥외형 발전소 (H 51 m, W 60 m, L 38 m, Kaplan 2기)가 있으며, 2015년 10월 착공하여 2020년 3월 상업발전을 시작하였다. 본 프로젝트는 DL E&C의 첫 번째 EPC 해외수력발전 프로젝트이다. 따라서 프로젝트의 성공적 수행을 위한 경제적 설계, 시공의 효율성 및 안정성 확보 등을 위하여 많은 연구를 수행하는 과정에서 다양한 기술 개선을 이룰 수 있었다. 본고에서는 Gulpur 프로젝트를 통하여 도출된 성공 사례들을 소개 및 공유하고자 한다. 첫 번째로 콘크리트 중력식댐 시공을 위한 유수전환시설의 최적 설계빈도를 산정하였다. 일반적으로 유수전환시설의 규모는 설계기준에 제시된 설계 재현빈도를 이용하는데, 해외 설계기준에서는 10년, 국내 설계기준에서는 1~2년으로 다르게 제시되어 있는 문제점이 있다. 유수전환시설의 규모는 프로젝트의 경제성에 큰 영향을 미치기 때문에 최적 설계빈도의 결정이 필요하며, 위험도분석기법(Risk Analysis)과 기대화폐가치법(Expected Monetary Value)을 이용하여 유수전환시설의 최적 설계 재현빈도와 이에 영향을 미치는 인자를 분석하였다. 위험도는 몬테카를로 시뮬레이션으로 산정된 가물막이댐 파괴확률과 재현빈도를 이용하여 산정된 가물막이댐 월류확률을 고려하였으며, 비용 및 피해액으로는 유수전환시설의 공사비, 가물막이댐 파괴시의 재건설비용과 지체보상금, 가물막이댐 월류시의 복구비용을 고려하였다. 이에 대한 연구결과로, 유수전환시설의 사용기간과 월류시의 복구비용이 유수전환시설의 설계 재현기간 결정에 가장 큰 영향을 미치는 것으로 나타났고, 특히 월류시의 복구비용이 작을수록 낮은 설계 재현빈도를 선택하는 것이 타당한 것으로 나타났다. 예를 들어, 유수전환시설의 사용기간이 3 ~ 5년, 복구비용이 0.5 ~ 1.0 mil USD 이하인 조건에서 가물막이시설의 최적 설계빈도는 1년 ~ 2년인 것으로 나타났다. 또한, 유수전환시설의 사용기간은 본댐의 규모와 시공기간 등을 고려하여 결정되는 사항으로 설계자가 임의 조정할 수 없지만, 복구비용은 시공 관리자에 따라 결정되는 부분으로, 적극적 홍수 피해 저감 및 복구방안을 마련하는 것이 프로젝트의 경제성을 향상시킬 수 있다는 것을 알 수 있었다. 두 번째로 프로젝트의 경제성 향상, 홍수기 댐 시공시의 안전성 확보를 위하여 홍수 조기경보시스템(Early Warning System)을 개발 및 활용하였다. 수로식(Run-of-river) 수력발전댐은 대부분 산악지역에 위치하기 때문에 국지성 강우 및 급한 지형 경사로 인하여 돌발홍수(flash flood)의 발생 가능성이 높다. 따라서 시공 중 홍수(월류) 발생을 미리 감지하고 현장에 전파할 수 있는, 수로식(Run-of-river) 수력발전댐 현장을 위한 홍수 조기경보시스템이 필요하며, 이를 리스크 인식, 모니터링 및 경보, 전파 및 연락, 반응 능력 향상의 4가지 부분으로 나누어 구축하였다. 리스크 인식 부분에서는 가물막이댐 월류 발생 상황에 대한 위험도, 취약성, 리스크를 제시하였으며, 모니터링 및 경보 부분에서는 상류 측정수위에서 유도된 현장 예상수위와 실제 현장 측정 수위를 대상으로 경보홍수위와 위험홍수위로 나누어 관리하였다. 전파 및 연락 부분에서는 현장 시공 조직을 활용하여 홍수시를 대비한 비상연락체계도(Emergency communication flow chart)를 운영하였으며, 반응 능력 향상을 위해 비상연락체계도의 팀별 Action plan을 상세화 하였다. 세 번째로 현장의 지질특성과 50여 차례 발파시험으로 현장 고유의 발파진동감쇄곡선을 도출하였으며, 이를 통해 현장의 시공성과 콘크리트 품질 확보를 동시에 달성할 수 있는 방안을 제시하였다. 콘크리트댐 공사에서는 제한된 공기 내에 공사를 완료하기 위해 사면부 굴착과 콘크리트 타설이 동시에 수행될 수밖에 없는 문제점을 가지고 있다. 그러나 신규 콘크리트 타설면 근처에서 발파를 수행하는 경우 발파로 발생되는 탄성파가 일정 수준을 초과하게 되면, 콘크리트 양생에 영향을 주게 된다. 따라서 다수의 현장 발파시험을 통해 발파거리와 최대진동속도의 상관관계 즉, 발파진동감쇄곡선을 도출함으로써 현장의 발파진동특성을 도출할 수 있었다. 또한, 기존 연구 논문들을 통해 콘크리트 재령기간 별 안전진동속도를 선정하고, 해당 안전진동속도를 초과하지 않는 범위에서 콘크리트 타설면과 발파위치의 거리에 따라 1회 발파 가능한 장약량을 산정하여 적용하였다. 이와 같은 체계적인 접근을 통해 콘크리트 타설과 발파 작업 동시 수행에 대한 논란을 해소할 수 있었다.

  • PDF

호남지역 저온형 온천수의 수리지화학적 및 안정동위원소 특성과 영족기체의 기원에 관한 연구 (Hydrochemical and Isotopic Characteristics, and Origin of Noble Gas for Low-temperature Hot Spring Waters in the Honam Area)

  • 정찬호;허현성;;김규한
    • 자원환경지질
    • /
    • 제40권5호
    • /
    • pp.635-649
    • /
    • 2007
  • 이 연구에서는 호남지역에 분포하는 5개 온천(죽림, 변산, 지리산, 덕산, 화순)에서 9개 온천시료와 인근의 지하수 시료 3개를 채취하여 수질화학 성분과 안정동위원소 $({\delta}^{18}O,\;{\delta}D,\;{\delta}^{34}S)$ 및 영족기체(He, Ne, Ar) 동위원소 분석을 통하여 온천수의 지화학적 특성, 지화학적 진화, 그리고 황, 헬륨, 아르곤의 기원을 해석하고자 하였다. 호남지역 온천수의 수온은 $23.0{\sim}30.5^{\circ}C$ 범위로 저온형 온천특성을 보이고 pH는 $7.67{\sim}9.98$ 범위로 알카리성의 특성을 보여주었다. 전기전도도는 $153{\sim}746{\mu}S/cm$ 범위로 지역에 따라서 큰 차이를 보여주었다. 온천주변 지하수의 수질특성은 온천수보다 낮은 pH와 전기전도도의 특성을 보여주었다. 온천수와 지하수의 지화학적 성분은 파이퍼도상에서 크게 3개의 유형으로 구분된다($Na-HCO_3$ 유형, Na-Cl 유형, $Ca-HCO_3$ 유형). 온천수의 지화학적 진화과정을 보면 초기에 $Ca-HCO_3$ 유형에서 출발하여 $Ca(Na)-HCO_3$ 유형을 거쳐 $Na-HCO_3$ 유형으로 진화하였으며, 일부 온천수는(JR1)의 경우 pH 9.98의 알카리성으로, $Na-HCO_3$ 유형의 종말점까지 도달하여 지화학적 진화의 최종단계에 도달되었음을 보여준다. 온천수의 산소 및 수소동위원소 조성은 순환수선을 따라 도시되며 지역에 따라 위도효과를 보인다. 황산염에 대한 황동위원소 대부분 화성기원을 보인다. 그러나 JR1 온천은 고염수에서 기원한 것으로 보이는 해양성기원을 보인다. 온천수의 $^3He/^4He$ 비와 $^4He/^{20}Ne$ 비는 $0.0143{\times}10^{-6}{\sim}0.407{\times}10^{-6}$ 범위와 $6.49{\sim}584{\times}10^{-6}$ 범위를 각각 보여주어 대기와 지각성분의 혼합선상에 도시된다. 이는 온천수내 헬륨가스의 대부분이 지각기원임을 의미한다. 죽림온천(JR1)의 경우 맨틀기원의 헬륨가스의 혼합율이 다른 온천에 비해 다소 높은 비율을 보여준다. 이들 동위원소비와 온천수의 pH와는 대체적으로 정의 상관관계가 확인되었다. 아울러 $^{40}Ar/^{36}Ar$비가 $292.3{\times}10^{-6}{\sim}304.1{\times}10^{-6}$ 범위로 대기기원임을 지시한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF