• Title/Summary/Keyword: design rule

Search Result 1,611, Processing Time 0.036 seconds

Axial Rotation of Toric Soft Lens by Corneal Astigmatism and Change of Posture (각막난시와 자세 변화에 의한 토릭소프트렌즈의 축 회전)

  • Kim, So Ra;Kim, Hyun Sun;Jung, Ga Won;Park, Hyung Min;Park, Sang Hee;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.441-447
    • /
    • 2013
  • Purpose: The present study was conducted to investigate the axial rotations of toric soft lens during the change of lens wearer's posture, and the relationship between its rotation and corneal astigmatism. Methods: The amount, direction, and speed of toric soft contact lens rotation were measured for 42 eyes (aged 20s) with the rule astigmatism in the straight and lying postures, and it compared between their changes according to corneal astigmatism. Results: There was no significant difference in the axial rotation of lens for the astigmatism prescription between the straight and lying postures. However, the rotation angle was significantly different according to the posture of lens wearer. Rotating directions in straight posture were nasal direction for 20 eyes and temporal direction for 22 eyes. In lying posture, lenses of most wearers were rotated to a direction of lying posture, and the initial rotating speed was very fast in initial wearing for -0.75 D toric lenses, but consistency for -1.25 D toric lenses. The rotation angle in lying posture showed significantly different according to the amount of corneal astigmatism, the lens speed was also significantly different according to the wearing time but not the amount of corneal astigmatism. Conclusions: The axial rotation of toric soft lens was different by the lens wearer's posture and its amount was the greater with the higher degree of corneal astigmatism. Thus, these factors should be considered for the development of toric lens design.

Design and Implementation of a BPEL Engine for Dynamic Function using Aspect-Oriented Programming (동적 기능 추가를 위하여 관점지향 프로그래밍 기법을 이용한 BPEL 엔진의 설계와 구현)

  • Kwak, Dong-Gyu;Choi, Jae-Young
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.37 no.4
    • /
    • pp.205-214
    • /
    • 2010
  • BPEL is a standard workflow language, which interacts with Web Services and is used in various applications. But it is difficult to use BPEL for specific applications which require additional functions. In this paper, we present a system which can add new functions to BPEL based on an aspect-oriented programming (AOP) technique. In order to add new functions to BPEL, we define a JWX document format that can describe new functions to apply to BPEL. JWX is XML-oriented document that can code the corresponding Java program in order to dynamically add new functions to BPEL documents. It is possible for BPEL workflow to add new functions without modifying the existing programs using the AOP technique, which guarantees low degree of coupling between key and additional requirements. Additionally this systems weaves based on new functions of Java program and JWX document by expanding BPEL engine called B2J based on AOP and execute them. Therefore it is possible to develop a new BPEL engine with additional functions easily and with low cost. The new system can execute additional conditions that the current BPEL engine doesn’t provide. The new system using functions of BPEL supplied by B2J. The new system can be used to add a new rule engine, which isn't currently provided.

Analysis on the Driving Safety and Investment Effect using Severity Model of Fatal Traffic Accidents (대형교통사고 심각도 모형에 의한 주행안전성 및 투자효과 분석)

  • Lim, Chang-Sik;Choi, Yang-Won
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.3
    • /
    • pp.103-114
    • /
    • 2011
  • In this study, we discuss a fatal accident severity model obtained from the analysis of 112 crash sites collected since 2000, and the resulting relationship between fatal accidents and roadway geometry design. From the 720 times computer simulations for improving driving safety, we then reached the following conclusions:. First, the result of cross and frequency-analyses on the car accident sites showed that 43.7% of the accidents occurred on the curved roads, 60.7% on the vertical curve section, 57.2% on the roadways with radius of curvature of 0 to 24m, 83.9% on the roads with superelevation of 0.1 to 2.0% and 49.1% on the one-way 2-lane roads; vehicle types involved are passenger vehicles (33.0%), trucks (20.5%) and buses (14.3%) in order of frequency. The results also show that the superelevation is the most influencing factor for the fatal accidents. Second, employing the Ordered Probit Model (OPM), we developed a severity model for fatal accidents being a function of on various road conditions so as to the damages can be predicted. The proposed model possibly assists the practitioners to predict dangerous roadway segments, and to take appropriate measures in advance. Third, computer simulation runs show that providing adequate superelevation on the segment where a fatal accident occurred could reduce similar fatal accidents by at least 85%. This result indicates that the regulations specified in the Rule for Road Structure and Facility Standard (description and guidelines) should be enhanced to include more specific requirement for providing the superelevation.

Power Reduction of Multi-Carrier Transmission System by Using Multi-Dimensional Constellation Mappings (효율적 다차원 성상도를 이용한 다중 반송파 전송 시스템의 전력 감소법)

  • Lee, Kyoung-Won;Kim, Jang-Hyun;Kim, Dae-Jin
    • Journal of Broadcast Engineering
    • /
    • v.14 no.6
    • /
    • pp.733-741
    • /
    • 2009
  • The design rule of digital communication systems is the reliable data transmission with high spectral efficiency and minimum allowable power. This paper suggests the method that saves the average power by implementing a multi-dimensional constellation in case of multi-carrier communication system. By using multi-dimensional constellations we can relocate constellation points in the form of a sphere. If we simply convert the two-dimensional QAM modulation into multi-dimensional QAM, constellation points of 2 N dimensional cube form are made up. Relocating outermost constellation points of 2 N dimensional cube form into low energy constellation points, the constellation of the 2 N-dimensional sphere form is made up which decreases power consumption. In this paper, the multi-dimensional constellations of 2 N-dimensional sphere form are designed from 16-QAM to 2,048-QAM, and power reductions are obtained by comparing constellations of 2-dimensional QAMs and multi-dimensional constellations of 2 N-dimensional sphere form. The result shows that the average power consumption of higher dimensional constellations increases, because the more a dimension elevates, the more the relocatable constellation points increase. But, the increment of the average power savings decreases as the a dimension elevates. The transmission of the data by using multi-dimensional constellations of the sphere form is effective to save the average power consumption with little hardware complexity.

Performance and SILC Characteristics of Flash Memory Cell With Ultra thin $N_2O$ Annealed Tunneling Oxide (초박막의 $N_2O$ 어닐링한 터널링 산화막을 갖는 Flash Memory Cell의 SILC 특성 및 성능)

  • Son, Jong-Hyoung;Chong, Jong-Wha
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.10
    • /
    • pp.1-8
    • /
    • 1999
  • In this paper, we have studies the transport mechanism and origin of SILC for the various thickness of wet oxide. Also, SILC characteristics of $N_2O$ annealed oxide was included in this study. We made the flash memory cell with $N_2O$ annealed oxide of 60Athick under $0.25{\mu}m$ design rule, and measured the characteristics of the cell. As a result, we have found that the origin of SILC is due to the trap formed inside of the oxide layer by electrical stress. And we reached the conclusion that the transport mechanism of SILC is ruled by the modified F-N tunneling if the electric field is lower than 8MV/cm or typical F-N tunneling if the electric field is higher than 8MV/cm. We could also confirm the fact that $N_2O$ annealed oxide of 60Athick have an improved resistance effect against SILC. In case that we apply $N_2O$ annealed oxide of 60Athick to the flash memory, we could confirm $10^6$ times endurance and more than 10 years drain disturb, and could get 8V programmable flash memory characteristics.

  • PDF

Quality of Working Life (직장생활에 대한 새로운 인식)

  • 김영환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.43-61
    • /
    • 1981
  • Interest in the Quality of working life is spreading rapidly and the phrase has entered the popular vocabulary. That this should be so is probably due in large measure to changes in the values of society, nowadays accelerated as never before by the concerns and demands of younger people. But however topical the concept has become, there is very little agreement on its definition. Rather, the term appears to have become a kind of depository for a variety of sometimes contradictory meanings attributed to it by different groups. A list of all the elements it if held to cover would include availability and security of employment, adaquate income, safe and pleasant physical working conditions, reasonable hours of work, equitable treatment and democracy in the workplace, the possibility of self-development, control over one's work, a sense of pride in craftsmanship or product, wider career choices, and flexibility in matters such as the time of starting work, the number of working days in the week, Job sharing and so on altogether an array that encompasses a variety of traditional aspirations and many new ones reflecting the entry into the post industrial era. The term "quality of working life" was introduced by professor Louis E. Davis and his colleagues in the late 1960s to call attention to the prevailing and needlessly poor quality of life at the workplace. In their usage it referred to the quality of the relationship between the worker and his working environment as a whole, and was intended to emphasize the human dimension so often forgotten among the technical and economic factors in job design. Treating workers as if they were elements or cogs in the production process is not only an affront to the dignity of human life, but is also a serious underestimation of the human capabilities needed to operate more advanced technologies. When tasks demand high levels of vigilence, technical problem-solving skills, self initiated behavior, and social and communication skills. it is imperative that our concepts of man be of requisite complexity. Our aim is not just to protect the worker's life and health but to give them an informal interest in their job and opportunity to express their views and exercise control over everything that affects their working life. Certainly, so far as his work is concerned, a man must feel better protected but he must also have a greater feeling of freedom and responsibility. Something parallel but wholly different if happening in Europe, industrial democracy. What has happened in Europe has been discrete, fixed, finalized, and legalized. Those developing centuries driving toward industrialization like R.O.K, shall have to bear in mind the human complexity in processing and designing the work and its environment. Increasing attention is needed to the contradiction between autocratic rule at the workplace and democratic rights in society.n society.

  • PDF

Application for Fire Protection Regulation based on Risk-Informed and Performance-Based Analysis (위험도 및 성능기반 분석방법에 의한 원전 화재방호규정 적용 방안)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.65-70
    • /
    • 2006
  • From the beginning of the construction stage, the fire protection regulation for the nuclear power plants conforms to the design requirements for the acquisition of the license permit. This regulation is based on the plant status of the normal operation, but it is not enough to be used as an application standard for fire protection at the transient mode of the plant and the outage time for refueling as well as for the plant decommissioning. While the advanced fire protection requirement that has been developed in America recently suggests the performance-based requirement and management rule applicable to the overall life time of the plant, it simply represents the conceptual application. It means that it can not be treated as appropriate standards because it does not deal with the qualitative and quantitative approach in specific ways. By the way, with the use of the performance-based fire risk analysis, the dynamic behavior of the heat and smoke at the fire compartment of the nuclear power plants can be analyzed and the thermal effect to the safety-related equipment and cables can be evaluated as well. At this paper, it suggests the ways to change the applicable fire protection regulations and the required evaluation items for the fire risk resulted from the plant configuration change with an intent to introduce the state-of-the-art quantitative fire risk analysis technology at the domestic nuclear power plants.

Study on Performance Variation According to the Arrangements of Adjacent Vertical-Axis Turbines for Tidal Current Energy Conversion (인접한 조류발전용 수직축 터빈의 배치방식에 따른 성능 변화)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.151-158
    • /
    • 2016
  • Tidal farm is a multi-arrayed turbine system for utilizing tidal stream energy. For horizontal-axis turbine(HAT) system, it is recommended that each unit has to be deployed far apart in order to avoid hydrodynamic interference among turbines, as proposed by the European Marine Energy Centre(EMEC). But there is no rule for the arrangement of vertical-axis turbine(VAT) yet. Moreover it has been reported that a proper arrangement of adjacent turbines can enhance the overall efficiency even greater than an arrangement without mutual interference effect. This paper suggests the layout of VATs showing the better performances, which turned out to be quite different from HATs' arrangement. Numerical calculations were performed to investigate the performance variation in terms of the rotational direction as well as the distance between turbines. It has been shown that the best combination of rotational direction and distance between turbines can increase its performance higher about 9.2% than that of two independently operated turbines. It is likely that such improvement is due to the increased velocity between adjacent turbines. For diagonally arranged turbines, the maximum normalized mean power coefficient was obtained to be higher about 5.6% than that of two independent turbines. It is expected that the present results can be utilized for conceptual design of tidal farm to harness the tidal stream energy.

Longitudinal Behavior of Prestressed Steel-Box-Girder Bridge (프리스트레스를 도입한 강합성형 교량의 교축방향 거동)

  • Park, Nam Hoi;Kang, Young Jong;Lee, Man Seop;Go, Seok Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.321-329
    • /
    • 2003
  • To effectively use the cross section of concrete decks, analytical and experimental studies on prestressed steel-box-girder bridges were performed in this study. The method of applying prestress was determined in the analytical study and the longitudinal behavior of the prestressed steel-box-girder bridge was considered in the experimental study. The object model for these studies was a two-span continuous bridge. The method of applying prestress determined herein was divided into two parts: one is that apply prestress to the concrete deck at its intermediate support, and the other is that apply prestress to the lower flange of the steel-box-girder bridge at its end support. The prototype bridge for the experiment was simulated based on the rule of similitude and was fabricated according to construction steps to apply prestress effectively. From the results of the experimental study, it has demonstrated that the prestressed steel-box-girder bridge provides better performance than the general steel-box-girder bridge in view of the increase of the design live load, the reduction of the tensile stress of the concrete deck at intermediate support, and the reduction of the displacement.

Bioequivalence of Samchundang Lercanidipine Tablet 10 mg to Zanidip Tablet (Lercanidipine Hydrochloride 10 mg) by Liquid Chromatography with Tandem Mass Spectrometry

  • Kim, Se-Mi;Kim, Hwan-Ho;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Kim, Yoon-Gyoon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.5
    • /
    • pp.315-321
    • /
    • 2007
  • The purpose of the present study was to evaluate the bioequivalence of two lercanidipine hydrochloride tablets, Zanidip tablet (LG Life Sciences Ltd., Korea, reference drug) and Samchundang Lercanidipine tablet 10 mg (Sam Chun Dang Pharm. Co. Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (amlodipine maleate) to human serum, serum samples were extracted using hexan-isoamyl alcohol (100:1, v/v). Compounds were analyzed by liquid chromatography/tandem mass spectrometry. This method showed linear response over the concentration range of 0.05-20 ng/mL with correlation coefficient of 0.9999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ng/mL which was sensitive enough for pharmacokinetic studies. Thirty healthy male Korean volunteers received each medicine at the lercanidipine hydrochloride dose of 20 mg in a $2\;{\times}\;2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of lercanidipine were monitored by an LC/MS/MS fer over a period of 24 hr after the administration. $AUC_t$ (the area under the serum concentration-time curve from time 0 to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (the maximum serum drug concentration) and $T_{max}$ (the time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters, indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Samchundang Lercanidipine/Zanidip were log 0.9505-log 1.2258 and log 0.9987-log 1.2013, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Samchundang Lercanidipine tablet 10 mg and Zanidip tablet are bioequivalent.