• 제목/요약/키워드: design of improved ground

검색결과 228건 처리시간 0.032초

A Novel System with EMG-controlled FES Enhanced Gait Function and Energy Expenditure for Older Adults

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung cheol Shin;Hwang-Jae Lee;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권2호
    • /
    • pp.152-162
    • /
    • 2024
  • Objective: This study was conducted to analyze the effect of wearable Electromyography-controlled functional electrical stimulation (EMG-controlled FES) System on Gait Function and cardiopulmonary metabolic efficiency during walking in older adults. Design: Cross-section study Methods: Total 22 older adult participants suitable to selection criteria of this study participated in this study. The EMG-controlled FES System, which functions as a wearable physical activity assist FES system was used. All participations performed randomly assigned two conditions (Non-FES assist [NFA], FES assist [FA]) of walking. In all conditions, spatio-temporal parameters and kinematics and kinetics parameters during walking was collected via 3D motion capture system and 6 minutes walking test (6MWT) and metabolic cost during walking and stairs climbing was collected via a portable metabolic device (COSMED K5, COSMED Srl, Roma, Italy). Results: In Spatio-temporal parameters aspects, The EMG-controlled FES system significantly improved gait functions measurements of older adults with sarcopenia at walking in comparison to the NFA condition (P<0.05). Hip, knee and ankle joint range of motion increased at walking in FA condition compared to the NFA condition (P<0.05). In the FA condition, moment and ground reaction force was changed like normal gait during walking of older adults in comparison to the NFA condition (P<0.05). The EMG-controlled FES system significantly reduced net cardiopulmonary metabolic energy cost, net energy expenditure measurement at stairs climbing (P<0.05). Conclusions: This study demonstrated that EMG-controlled FES is a potentially useful gait-assist system for improving gait function by making joint range of motion and moment properly.

금속재질 열교환기의 지중 열교환 효율에 관한 연구 (Study on Efficiency for Underground Heat Transfer of Metal Heat Exchanger)

  • 송재용;김기준;안상곤;김진성;정교철
    • 지질공학
    • /
    • 제25권1호
    • /
    • pp.131-148
    • /
    • 2015
  • 본 연구는 지열시스템 열교환 효율의 개선방안을 모색하기 위한 것으로 금속재질의 열교환기인 동관 및 스테인레스관과 기존 지열시스템에 많이 적용되는 PE관을 이용하여 지열열교환기의 재질에 따른 열전달 효율을 비교 분석하였다. 또한 지하매질의 지하수에 포함되어 있는 지하수열을 동시 활용할 경우의 열전달 효율 변화를 평가하고 그 적용성을 검토하였다. 열교환기 내의 유속, 유량 및 열교환기의 구경을 조절함으로써 열교환기의 재질에 따른 열전달 효율을 평가 후 현장실증시험 설계인자를 도출하였다. 열교환 효율과 유효 열전도도는 현장 열전달 효율 시험 및 열응답 시험을 통해 변화양상을 분석하였다. 분석결과 금속재질이 PE관에 비해 높은 열전달 효율을 보였으며, 유량에서의 구경증대에 따른 열전달효율은 크지 않았으나 유속에서의 구경증대에 따른 열전달효율은 높아지는 것을 확인하였다.

자력을 이용한 마찰진자 베어링의 면진성능 (Base Isolation Performance of Friction Pendulum System using Magnetic Force)

  • 황인호;신호재;이종세
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.55-61
    • /
    • 2008
  • 면진장치 중에서 최근 많은 연구가 이루어지고 있는 마찰진자 베어링은 적절한 마찰력을 얻기 위해 PTFE(Polytetrafluoroethylene) 마찰재가 이용되고 있다. 본 연구에서는 자력의 반발력을 이용해 재료의 성질을 대체하여 면진성능을 향상 시킬 수 있는 자력을 이용한 마찰진자 베어링을 제안하였다. 제안된 시스템은 자력에 의한 반발력이 수직력을 줄여줌으로써 재료에 의한 마찰계수의 영향을 줄일 수 있음을 가정하였다. 또한 자력의 영향을 가정하기 위해서 간단한 실험을 구성해 보았으며, 자력이 작용을 할 때 마찰계수($\mu$)를 약 20%정도 줄여줄 수 있었다. 실험 결과를 적용한 수치해석을 통해 다양한 지진에 대해서 기존의 마찰진자 베어링보다 향상된 성능을 보여주었고, 특히 지진으로 인해 구조물의 파괴에 작용하는 주된 요소인 최상층의 가속도와 구조물의 상대변위를 비교함으로써 제안된 시스템이 면진장치로서의 기능을 가지고 있음을 확인하였다. 자력을 이용하여 기존의 PTFE 마찰재를 대체할 수 있는 자력을 이용한 마찰진자 베어링의 구조적 설계를 할 수 있다면 마찰진자 베어링의 문제점을 보완한 기초격리장치로서 적용될 수 있을 것으로 사료된다.

선박기지국 응용을 위한 중계기용 U형 급전 안테나 설계 (The Design of repeater U-shaped Antenna for ship base station Applications)

  • 박창현;김영남;김갑기
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2007년도 추계학술발표회
    • /
    • pp.211-214
    • /
    • 2007
  • 본 논문에서는 800MHz대역의 TRS(Trunked Radio System)대역을 비롯한, GSM(Global System for Mobile telecommunication), CDMA(Code Division Multiple Access) 대역을 통합할 수 있는 광대역 마이크로스트립 안테나를 설계하고자 한다. 그리고 선박 및 해상 안전에 상용 가능한 선박 기지국 중계기용 안테나를 설계하였다. 마이크로 스트립 안테나의 협대역을 개선하기 위해서 직사각형 패치에 U자 형태의 급전구조를 갖고, 그라운드와 급전 사이에 유전체(${\varepsilon}_T$ = 2.1), 패치와 급전 사이에는 유전체 (${\varepsilon}_T$ = 1)인 서로 다른 유전체를 사용하여 이중 공진 효과를 이용하였다. 설계된 안테나의 주파수 대역폭(VSWR 2:1)은 $780MHz{\sim}1.83GHz$로 2.61GHz의 광대역 특성을 보였으며. 또한 E-평면과 H-평면 모두 이득은 9.dBi이상. 3dB 빔폭은 E-평면 과 H-평면 $60^{\circ}$이상의 개선된 특성을 보였다.

  • PDF

PCS 대역 안테나 내장형 단말기와 외장형 단말기의 방사패턴과 무선감도 (Radiation Pattern and Radio Sensitivity of PCS Band Mobile Phones with Internal Antenna and External Antenna)

  • 공성신;오종대;양운근
    • 한국전자파학회논문지
    • /
    • 제15권4호
    • /
    • pp.397-405
    • /
    • 2004
  • 본 논문에서는PCS대역 안테나내장형 단말기의 성능에 관하여 살펴보았다. 안테나와 안테나 내장형 단말기의 방사패턴을 3차원 전산모의실험 프로그램인 HFSS(High Frequency Structure Simulator)와 SEMCAD(Simulator Platform for Electromagnetic Compatibility Antenna Design and Dosimetry)를 이용하여 전산모의실험하였다. 단말기에 장착된 LED(Light Emitting Bi여e) 회로와 접지판의 형태에 따른 방사패턴의 변화를 살펴보았으며, 외장형안테나 단말기와 내장형 안테나 단말기의 안테나 방사패턴을 원거리장 측정 시스템을 사용하여 전자파 무반사실에서 측정하였다. 측정결과 내장형 안테나는 전산모의실험 결과와 유사한 패턴을 보였다. 그리고 전자파 무반사실에서 Agilent E5515C를 사용하여 안테나 외장형 단말기와 안테나 내장형 단말기의 무선감도를 측정하여 비교하였다. 측정된 안테나내장형 단말기의 무선감도는 안테나 외장형 단말기의 무선감도와 비교해 유사한 성능을 보였으며 수평면상의 동일편파 무선감도 평균치의 경우 차이가 0.12 ㏈로 나타났다.

적층구조를 이용한 IEEE 802.11a용 $2{\times}1$ 배열 안테나 설계 (Design of $2{\times}1$ Array Antenna Using Stack Structure for IEEE 802.11a)

  • 박정아;부종배;김갑기
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.849-852
    • /
    • 2007
  • 본 논문에서는 마이크로스트립 안테나의 좁은 대역폭 문제를 개선하여 IEEE 802.11a의 표준규격(가. $5.15{\sim}5.25$[GHz], 나. 5.25${\sim}5.35$[GHz], 다. $5.725{\sim}5.875$[GHz])을 모두 포함할 수 있는 5[GHz]대역 광대역, 고 이득 안테나를 설계하였다. 설계된 패치 안테나는 소형화를 위해 분리되어진 방사패치와 기생패치 사이에 유전체(폴리우레탄 : ${\varepsilon}_r=6.5$)를 삽입하여 공진주파수를 조정하였으며, 공기에 의해 분리되어진 방사패치와 접지면을 폼(${\varepsilon}_r=1.03$)으로 고정시켰다. 설계된 안테나의 주파수 대역폭(VSWR 2:1)은 $4.9[GHz]{\sim}6.1[GHz]$까지 약1.2[GHz]의 광대역 특성을 보였으며, 또한 E-평면과 H-평면 이득은 12[dBi]이상, 3[dB] 빔폭은 E-평면 $30^{\circ}$와 H-평면 $60^{\circ}$이상의 개선된 특성을 보였다.

  • PDF

이중 LTE 대역의 MIMO 안테나 설계 (Design of Dual LTE-band MIMO Antenna)

  • 최원상;이홍민
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권1호
    • /
    • pp.46-52
    • /
    • 2011
  • 본 논문에서는 이중 LTE 대역의 MIMO 안테나를 제안하였다. 제안된 안테나는 FR-4 기판 (${\epsilon}_r=4.4$, 두께 = 0.8 mm)의 윗 면에 설계되어졌다. 제안된 구조는 안테나의 소형화를 위하여 미엔더 구조와 폴디드 구조가 적용된 PIFA 형태로 설계되었으며, 두개의 안테나를 공통 접지면 상단에 대칭으로 위치시키고 접지면에 두개의 슬릿을 부설하여 이중 LTE 대역에서 격리도를 향상시켰다. 제작된 안테나의 측정결과 LTE 13 (0.748 GHz ~ 0.787 GHz)과 LTE 7 (2.5 GHz ~ 2.69 GHz)대역을 동시에 만족시키며 두 안테나 사이의 격리도는 LTE 13과 LTE 7 대역에서 각각 -18 dB, -13 dB를 나타내었다. LTE 13대역에서 평균 이득과 효율은 각각 - 4.1 dBi, 41%이고, LTE 7대역에서는 -1 dBi, 81% 값을 나타내었다. 따라서 제안된 안테나는 LTE 시스템에 적용될 수 있을 것으로 사료된다.

Effects of Extrusion Condition of Barley on the Growth and Nutrient Utilization in Growing Pigs

  • Piao, X.S.;Chae, B.J.;Kim, J.H.;Jin, J.;Cho, W.T.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권5호
    • /
    • pp.783-787
    • /
    • 1999
  • To study the effects of different extrusion conditions of barley on growth performance, nutrient digestibility and nutrient excretion in feces, a total of 150 growing pigs ($Landrace{\times}Duroc{\times}Large$ White; average 24.4 kg body weight) were allotted to five treatments, in a completely randomized block design. The experimental diets were based on corn-soybean and 30% of barley was included in each diet; barley was the only extruded ingredient. The treatments were 1) no extrusion (Control); 2) extrusion at $100^{\circ}C$ without preconditioning (ENLT); 3) extrusion at $150^{\circ}C$ without preconditioning (ENHT); 4) extrusion at $100^{\circ}C$ with preconditioning (ECLT); 5) extrusion at $150^{\circ}C$ with preconditioning (ECHT). Temperature in the barrel was controlled within ${\pm}5^{\circ}C$ by feed rate with the addition of water at the rate of $3{\ell}\;per\;min$. in the extruder for each treatment. For the 6 week experimental period, extrusion of barley improved the average daily gain (ADG) and digestibilities of dry matter, crude protein and gross energy in growing pigs. As compared to control, significant improvements in ADG (p<0.05) were shown in the groups of feeding extruded barley at high temperature (ENHT and ECHT). There were also significant differences in the digestibilities of DM, CP and P between extrusion temperatures. Barley extruded at high temperature gave better digestibilities of DM, CP and GE than barley extruded at low temperature. Extruded barley diet groups showed significantly (p<0.05) lower excretions of DM, nitrogen (N) and P per kg gain as compared to the ground barley group. DM, N and P excretion per kg gain were also significantly lower in pigs fed barley extruded at $150^{\circ}C$ than at $100^{\circ}C$. In conclusion, extrusion considerably improved the nutritive value of barley and it appeared that temperature is the most important variable.

고로슬래그 미분말을 65% 치환한 고성능 콘크리트의 자기 및 건조수축 특성 (Characteristics of Drying and Autogeneous Shrinkage in HPC with 65% Replacement of GGBFS)

  • 장승엽;류화성;윤용식;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권3호
    • /
    • pp.54-59
    • /
    • 2017
  • 고로슬래그 미분말은 공학적으로 우수한 건설산업 부산물이며, 최근들어 환경부하 저감 및 사용 활성화를 위해 대단위 슬래그 치환 콘크리트가 많이 연구되고 있다. 본 연구에서는 목표 강도를 50 MPa로 설정하고 고로슬래그미분말 치환률을 65%로 고려한 대단위 치환 슬래그 콘크리트를 제조하여 건조수축특성과 초지재령 특성을 평가하였다. 이를 위해 3 수준의 콘크리트를 제조하였으며, 슬럼프 플로우, 강도, 건조 및 자기수축에 대한 실험을 수행하였다. 실험결과, 보통 포틀랜트 시멘트를 100% 함유한 콘크리트(OPC 100)에 비하여 재령 7일전의 강도는 약간 감소하였으나, 슬래그 치환 배합은 수화에 필요한 충분한 자유수를 가졌으므로 28일 재령에서는 우수한 강도 발현을 나타내었다. 또한 재령 3일까지 큰 자기수축으로 인하여, OPC 100 배합에서는 건조수축이 크게 평가되었지만, 65% 고로슬래그 미분말을 치환한 배합에서는 초기재령의 자기수축 성능이 개선되어 우수한 건조수축거동을 나타내었다. 특히 단순 질량 치환배합(BS 65)보다 물-결합재비(0.27)와 단위수량($163kg/m^3$)을 낮춘 OPTBS 65에서 더욱 우수한 건조수축 및 자기수축 거동을 나타내었다.

Study of seismic performance of super long-span partially earth-anchored cable-stayed bridges

  • Zhang, Xin-Jun;Yu, Cong;Zhao, Jun-Jie
    • Structural Engineering and Mechanics
    • /
    • 제72권1호
    • /
    • pp.99-111
    • /
    • 2019
  • To investigate the seismic performance of long-span partially earth-anchored cable-stayed bridge, a super long-span partially earth-anchored cable-stayed bridge scheme with main span of 1400m is taken as example, structural response of the bridge under E1 seismic action is investigated numerically by the multimode seismic response spectrum and time-history analysis, seismic behavior and also the effect of structural geometric nonlinearity on the seismic responses of super long-span partially earth-anchored cable-stayed bridges are revealed. The seismic responses are also compared to those of a fully self-anchored cable-stayed bridge with the same main span. The effects of structural parameters including the earth-anchored girder length, the girder width, the girder depth, the tower height to span ratio, the inclination of earth-anchored cables, the installation of auxiliary piers in the side spans and the connection between tower and girder on the seismic responses of partially ground-anchored cable-stayed bridges are investigated, and their reasonable values are also discussed in combination with static performance and structural stability. The results show that the horizontal seismic excitation produces significant seismic responses of the girder and tower, the seismic responses of the towers are greater than those of the girder, and thus the tower becomes the key structural member of seismic design, and more attentions should be paid to seismic design of these sections including the tower bottom, the tower and girder at the junction of tower and girder, the girder at the auxiliary piers in side spans; structural geometric nonlinearity has significant influence on the seismic responses of the bridge, and thus the nonlinear time history analysis is proposed to predict the seismic responses of super long-span partially earth-anchored cable-stayed bridges; as compared to the fully self-anchored cable-stayed bridge with the same main span, several stay cables in the side spans are changed to be earth-anchored, structural stiffness and natural frequency are both increased, the seismic responses of the towers and the longitudinal displacement of the girder are significantly reduced, structural seismic performance is improved, and therefore the partially earth-anchored cable-stayed bridge provides an ideal structural solution for super long-span cable-stayed bridges with kilometer-scale main span; under the case that the ratio of earth-anchored girder length to span is about 0.3, the wider and higher girder is employed, the tower height-to-span ratio is about 0.2, the larger inclination is set for the earth-anchored cables, 1 to 2 auxiliary piers are installed in each of the side spans and the fully floating system is employed, better overall structural performance is achieved for long-span partially earth-anchored cable-stayed bridges.