• 제목/요약/키워드: design low-flow

검색결과 1,011건 처리시간 0.028초

소음예측 비례식을 이용한 자동차 엔진 공회전 속도 제어 장치 유로의 저소음 설계 (Low-noise Design of Passage of Idle Speed Control Actuator In Automotive Engines Using Scaling Laws for Noise Prediction)

  • 정철웅;김재현;김성태;박용환;이수갑
    • 한국소음진동공학회논문집
    • /
    • 제17권8호
    • /
    • pp.683-692
    • /
    • 2007
  • Recently, plastic products in air-intake parts of automotive engines have become very popular due to advantages that include reduced weight, constricted cost, and lower intake air temperature. However, flow-induced noise in air-intake parts becomes a more serious problem for plastic intake-manifolds than for conventional aluminum-made manifolds. This is due to the fact that plastic manifolds transmit more noise owing to their lower material density. Internal aerodynamic noise from an idle speed control actuator(ISA) is qualitatively analyzed by using a scaling law, which is expressed with some flow parameters such as pressure drop, maximum flow velocity, and turbulence kinetic energy. First, basic flow characteristics through ISA passage are identified with the flow predictions obtained by applying computational fluid dynamics techniques. Then, the effects on ISA passage noise of each design factors including the duct turning shape and vane geometries are assessed. Based on these results, the preliminary low noise design for the ISA passage are proposed. The current method for the prediction of internal aerodynamic noise consists of the steady CFD and the scaling laws for the noise prediction. This combination is most cost-effective, compared with other methods, and therefore is believed to be suited for the preliminary design tool in the industrial field.

펌프장내 흡수정 설계 기준 (The Standard of Sump Design in Pump Station)

  • 노형운;오상현;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.589-592
    • /
    • 2005
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Unfortunately in order to design the sump station, the reasonable code or the standards weren't presented yet in Korea. Thus, some researchers had often referred the HI code, JSME code or CEN code to design the sump station. This study aims to prescribe the standard of sump design which were matched well the Korean pump station. Thus, the HI code and TSJ code would be interpreted fully to Korean language, the part of interpreted clauses of the western codes would be selected to compose the standard.

  • PDF

대리모델을 사용한 축류송풍기 블레이드의 형상 최적화 (Shape Optimization of Axial Flow Fan Blade Using Surrogate Model)

  • 김진혁;최재호;김광응
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2440-2443
    • /
    • 2008
  • This paper presents a three dimensional shape optimization procedure for a low-speed axial flow fan blade with a weighted average surrogate model. Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model are discretized by finite volume approximations. Six variables from airfoil profile and lean are selected as design variables. 3D RANS solver is used to evaluate the objective functions of total pressure efficiency. Surrogate approximation models for optimization have been employed to find the optimal design of fan blade. A search algorithm is used to find the optimal design in the design space from the constructed surrogate models for the objective function. The total pressure efficiency is increased by 0.31% with the weighted average surrogate model.

  • PDF

스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험 (Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures)

  • 심규호;정민성;이윤표;장선준
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.

Vortices within a Three-Dimensional Separation in an Axial Flow Stator of a Diagonal Flow Fan

  • Kinoue, Yoichi;Shiomi, Norimasa;Setoguchi, Toshiaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권2호
    • /
    • pp.262-270
    • /
    • 2011
  • Experimental and numerical investigations were conducted for an internal flow in an axial flow stator of a diagonal flow fan. A corner separation near the hub surface and the suction surface of a stator blade was focused on, and further, three-dimensional vortices in separated flow were investigated by the numerical analysis. At low flow rate of 80% of the design flow rate, a corner separation of the stator between the suction surface and the hub surface can be found in both experimental and calculated results. Separation vortices are observed in the limiting streamline patterns both on the blade suction and on the hub surfaces at 80% of the design flow rate in the calculated results. It also can be observed in the streamline pattern that both vortices from the blade suction surface and from the hub surface keep vortex structures up to far locations from these wall surfaces. An attempt to explain the vortices within a three-dimensional separation is introduced by using vortex filaments.

한강 여의도지구 수변공원 식재설계 (Landscape Planting Design for Yeoyido Flood Plain Park in Han-river)

  • 이준복
    • 한국조경학회지
    • /
    • 제31권5호
    • /
    • pp.86-95
    • /
    • 2003
  • It had been strictly prohibited to plant in waterway according to Korea laws and regulations. It was then made possible to plant by the modification law and regulation of 10/30/1997. In 2000, the Seoul metropolis government planted in the Yeoyido flood plain park in Han river by way of showing the model case. This planting design is for the Yeoyido flood plain park along the Han river, in Seoul. The design requirements were to create a pleasant rest area, to improve the surrounding landscape, and to create diverse ecological habitats by planting within the stability of flood flow. This design emphasizes the following design requirements that has positive effect on stabilizing flood flow. First, planting suitable in a area was determined by the speed of a current of less than 0.7m/sec under various numerical value simulations. Second, plants were selected in existing trees of the present and the past Han river, as well as the questionnaire results from landscape professional engineers and professors. Shade plants were planted in the large visiting areas so as to offer pleasant shade in the summer, the ecological planting pattern was applied in the area with low speed of flood flow, so as to aid the restoration of the natural ecological environment. It was found that the foresaid planting design verified the stability of flood flow and wind by overturn limit moment calculation. It is expected that this plan would serve environmentally friendly planting plans in flood plain park.

LID Retrofit 시범단지 설계 절차 개선 (Improvement of the Design Process of LID Retrofit Testbed for Effect Analysis of the Water Cycle)

  • 정종석;임정민;현경학
    • 토지주택연구
    • /
    • 제8권4호
    • /
    • pp.267-274
    • /
    • 2017
  • 국내에는 도시재생에 대한 Retrofit치원의 LID 설계절차가 정립되어 있지 않기 때문에, 문헌조사와 전문가 자문을 통하여 기존 LID 설계절차를 정립하였다. 그러나 정립된 LID 설계 절치는 활용되는 공간정보의 한계와 도시재생 지역에 배수구역 구분이 어려운 문제 등 여러 가지 제한이 있었다. 이러한 설계 절차의 한계를 해결하기 위해 추가적으로 정밀 측량을 통한 분석이 필요하고, 이 후에는 물의 흐름이 원활할 수 있도록 시설을 선정하고 배치하는 것이 중요하다. 이러한 고려를 통해 본 연구는 도시재생 지역에 적용 할 수 있는 LID 설계절차를 제시하였다.

ANALYSES ON FLOW FIELDS AND PERFORMANCE OF A CROSS-FLOW FAN WITH VARIOUS SETTING ANGLES OF A STABILIZER

  • Kim D. W.;Kim H. S.;Park S. K.;Kim Youn J
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.107-112
    • /
    • 2005
  • A cross-flow fan is generally used on the region within the low static pressure difference and the high flow rate. It relatively makes high dynamic pressure at low rotating speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. At off-design points, there are a rapid pressure head reduction, a noise increase and an unsteady flow. Those phenomena are remarkably influenced by the setting angle of a stabilizer. Therefore, it should be considered how the setting angle of a stabilizer affects on the performance and the flow fields of a cross-flow fan. It is also required to investigate the effect of the volumetric flow rate before occurring stall. Two-dimensional, unsteady governing equations are solved using a commercial code, STAR-CD, which uses FVM. PISO algorithm, sliding grid system and standard k - ε turbulence model are also adopted. Pressure and velocity profiles with various setting angles are graphically depicted. Furthermore, the meridional velocity profiles around the impeller are plotted with different flow rates for a given rotating speed.

전산유체역학 해석에 기반한 20kW급 도립형 횡류수차의 제작 및 성능 실증 (Fabrication and Performance Demonstration of the 20kW Class Inverted-type Cross-flow Turbine Based on Computational Fluid Dynamics Analysis)

  • 함상우;최지웅;정창호;김태윤;최상인;진근영;이정완;하호진
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.107-119
    • /
    • 2021
  • The cross-flow turbine is one of the most famous and widely used hydraulic power systems for a long time. The cross-flow turbine is especially popular in many countries and remote regions where off-grided because of its many benefits such as low cost, high efficiency at low head, simple structure, and easy maintenance. However, most modern turbines, including the cross-flow turbine, are unsuitable for the ultra-low head situation, known as less than 3m water head or zero head with over 0.5m/s flow velocity. In this study, we demonstrated a 20kW class inverted-type cross-flow turbine's performance. First, we reevaluated our previous studies and introduced how to design the inverted-type cross-flow turbine. Secondly, we fabricated the 20kW class inverted-type cross-flow turbine for the performance test. And then, we designed a testbed and installed the turbine system in the demonstration facility. In the end, we compare the demonstration with its previous CFD results. The comparing result shows that both CFD and real model fitted on guide vane angle at 10 degrees. At the demonstration, we achieved 42% turbine efficiency at runner speed 125 RPM.

사보니우스 풍력발전기의 유동소음특성에 관한 수치적 연구 (Numerical Analysis on the Flow Noise Characteristics of Savonius Wind Turbines)

  • 김상현;정철웅
    • 한국소음진동공학회논문집
    • /
    • 제23권6호
    • /
    • pp.502-511
    • /
    • 2013
  • Noise performance of small wind turbines is critical since these are generally installed near the community. In this study, flow noise characteristics of Savonius wind turbines are numerically investigated. Flow field around the turbine are computed by solving unsteady RANS equation using CFD techniques and the radiated noise are predicted by applying acoustic analogy to the computed flow data. Parametric study is then carried out to investigate the effects of operating conditions and geometric design factors of the Savonius wind turbine. Tonal noise components with higher harmonic frequency than the BPF are identified in the predicted noise spectra from a Savonius wind turbine. The end-plates and helical blades are shown to reduce overall noise levels. These results can be used to design low-noise Savonius wind turbines.