• 제목/요약/키워드: dentin adhesives

검색결과 118건 처리시간 0.028초

Effect of additional etching and ethanol-wet bonding on the dentin bond strength of one-step self-etch adhesives

  • Ahn, Joonghee;Jung, Kyoung-Hwa;Son, Sung-Ae;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.68-74
    • /
    • 2015
  • Objectives: This study examined the effects of additional acid etching on the dentin bond strength of one-step self-etch adhesives with different compositions and pH. The effect of ethanol wetting on etched dentin bond strength of self-etch adhesives was also evaluated. Materials and Methods: Forty-two human permanent molars were classified into 21 groups according to the adhesive types (Clearfil SE Bond [SE, control]; G-aenial Bond [GB]; Xeno V [XV]; Beauti Bond [BB]; Adper Easy Bond [AE]; Single Bond Universal [SU]; All Bond Universal [AU]), and the dentin conditioning methods. Composite resins were placed on the dentin surfaces, and the teeth were sectioned. The microtensile bond strength was measured, and the failure mode of the fractured specimens was examined. The data were analyzed statistically using two-way ANOVA and Duncan's post hoc test. Results: In GB, XV and SE ($pH{\leq}2$), the bond strength was decreased significantly when the dentin was etched (p < 0.05). In BB, AE and SU (pH 2.4 - 2.7), additional etching did not affect the bond strength (p > 0.05). In AU (pH = 3.2), additional etching increased the bond strength significantly (p < 0.05). When adhesives were applied to the acid etched dentin with ethanol-wet bonding, the bond strength was significantly higher than that of the no ethanol-wet bonding groups, and the incidence of cohesive failure was increased. Conclusions: The effect of additional acid etching on the dentin bond strength was influenced by the pH of one-step self-etch adhesives. Ethanol wetting on etched dentin could create a stronger bonding performance of one-step self-etch adhesives for acid etched dentin.

Do universal adhesives promote bonding to dentin? A systematic review and meta-analysis

  • Elkaffas, Ali. A.;Hamama, Hamdi H.H.;Mahmoud, Salah H.
    • Restorative Dentistry and Endodontics
    • /
    • 제43권3호
    • /
    • pp.29.1-29.13
    • /
    • 2018
  • Objectives: The aims of this study were to conduct a systematic review of the microtensile bond strength (${\mu}TBS$) of multi-mode adhesives to dentin and to perform a meta-analysis to assess the significance of differences in the ${\mu}TBS$ of one of the most commonly used universal adhesives (Scotchbond Universal, 3M ESPE) depending on whether the etch-and-rinse or self-etch mode was used. Materials and Methods: An electronic search was performed of MEDLINE/PubMed, ScienceDirect, and EBSCOhost. Laboratory studies that evaluated the ${\mu}TBS$ of multi-mode adhesives to dentin using either the etch-and-rinse or self-etch mode were selected. A meta-analysis was conducted of the reviewed studies to quantify the differences in the ${\mu}TBS$ of Scotchbond Universal adhesive. Results: Only 10 studies fulfilled the inclusion criteria for the systematic review. Extensive variation was found in the restorative materials, testing methodologies, and failure mode in the reviewed articles. Furthermore, variation was also observed in the dimensions of the microtensile testing beams. The meta-analysis showed no statistically significant difference between the etch-and-rinse and self-etch modes for Scotchbond Universal adhesive (p > 0.05). Conclusions: Multi-mode 'universal' adhesives can achieve substantial bonding to dentin, regardless of the used modes (either etch-and-rinse or self-etch).

Bonding of a resin-modified glass ionomer cement to dentin using universal adhesives

  • Ugurlu, Muhittin
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.36.1-36.10
    • /
    • 2020
  • Objectives: This study aims to assess the effect of universal adhesives pretreatment on the bond strength of resin-modified glass ionomer cement to dentin. Materials and Methods: Fifty caries-free human third molars were employed. The teeth were randomly assigned into five groups (n = 10) based on dentin surface pretreatments: Single Bond Universal (3M Oral Care), Gluma Bond Universal (Heraeus Kulzer), Prime&Bond Elect (Dentsply), Cavity Conditioner (GC) and control (no surface treatment). After Fuji II LC (GC) was bonded to the dentin surfaces, the specimens were stored for 7 days at 37℃. The specimens were segmented into microspecimens, and the microspecimens were subjugated to microtensile bond strength testing (1.0 mm/min). The modes of failure analyzed using a stereomicroscope and scanning electron microscopy. Data were statistically analyzed with one-way analysis of variance and Duncan tests (p = 0.05). Results: The surface pretreatments with the universal adhesives and conditioner increased the bond strength of Fuji II LC to dentin (p < 0.05). Single Bond Universal and Gluma Bond Universal provided higher bond strength to Fuji II LC than Cavity Conditioner (p < 0.05). The bond strengths obtained from Prime&Bond Elect and Cavity Conditioner were not statistically different (p > 0.05). Conclusions: The universal adhesives and polyacrylic acid conditioner could increase the bond strength of resin-modified glass ionomer cement (RMGIC) to dentin. The use of universal adhesives before the application of RMGIC may be more beneficial in improving bond strength.

수종의 상아질 접착제와 복합레진의 적합성에 관한 연구 (A STUDY ON THE COMPATIBILITY OF DENTIN ADHESIVES WITH COMPOSITE RESINS)

  • 박진성;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.214-234
    • /
    • 1995
  • The purpose of this work was to study the compatibility of several commercially available dentin adhesives with composite resins. In this study, V-shaped cavity preparations were created on both buccal and lingual surfaces of 60 extracted human premolars($3mm{\times}3mm{\times}2mm$ deep). Preparations were located such that the occlusal margins were on the enamel and the gingival margins were on the cementum(1mm below the CEJ). These specimens were randomly divided into three equal groups. Three dentin adhesives(Scotchbond Multi-Purpose, All Bond 2, Prisma Universal Bond 3)were applied to the cavity in accordance with each manufacturer's instructions. The teeth in each group were restored with four composite resins(Silux plus, Z100, Bisfil, Prisma TPH) in three increments, with each increment light-cured for 40 seconds. All specimens were exposed to 500 cycles of thermal stress. Specimens then placed in a silver nitrate solution(50% by weight) and stored in darkness for 24 hours. They were then immersed for 6 hours in photographic developing solution under flourescent light. Specimens were sectioned buccolingually through the center of the restoration and observed under a binocular stereoscope. To compare the marginal leakage, ANOVA and Dunkan's multiple range tests were used in analysis. Selected samples were further studied using scanning electron microscopy(XL20, Philips, The Netherlands). The results were as follows. 1. In all groups, the enamel margin showed significantly less leakage than the cementum margin. 2. No statistically significant differences were found in microleakage when composite resins were used with their proprietary dentin adhesives. 3. In comparison between dentin adhesives, Prisma Universal Bond 3 showed significantly less leakage at the enamel margin and Scotch bond multi-purpose showed significantly less leakage at the cementum margin than the other groups. 4. In comparison between composite resins, Silux Plus showed significantly more leakage than other groups at the enamel margin and no statistically significant differences were found in microleakage at the cementum margin. 5. According to the backscattered scanning electron microscope, microleakage occurred via gaps at the dentin adhesives/dentin interface.

  • PDF

Effect of smear layer deproteinization on bonding of self-etch adhesives to dentin: a systematic review and meta-analysis

  • Alshaikh, Khaldoan H.;Hamama, Hamdi H.H.;Mahmoud, Salah H.
    • Restorative Dentistry and Endodontics
    • /
    • 제43권2호
    • /
    • pp.14.1-14.16
    • /
    • 2018
  • Objectives: The aim of this systematic review was to critically analyze previously published studies of the effects of dentin surface pretreatment with deproteinizing agents on the bonding of self-etch (SE) adhesives to dentin. Additionally, a meta-analysis was conducted to quantify the effects of the above-mentioned surface pretreatment methods on the bonding of SE adhesives to dentin. Materials and Methods: An electronic search was performed using the following databases: Scopus, PubMed and ScienceDirect. The online search was performed using the following keywords: 'dentin' or 'hypochlorous acid' or 'sodium hypochlorite' and 'self-etch adhesive.' The following categories were excluded during the assessment process: non-English articles, randomized clinical trials, case reports, animal studies, and review articles. The reviewed studies were subjected to meta-analysis to quantify the effect of the application time and concentration of sodium hypochlorite (NaOCl) and hypochlorous acid (HOCl) deproteinizing agents on bonding to dentin. Results: Only 9 laboratory studies fit the inclusion criteria of this systematic review. The results of the meta-analysis revealed that the pooled average microtensile bond strength values to dentin pre-treated with deproteinizing agents (15.71 MPa) was significantly lower than those of the non-treated control group (20.94 MPa). Conclusions: In light of the currently available scientific evidence, dentin surface pretreatment with deproteinizing agents does not enhance the bonding of SE adhesives to dentin. The HOCl deproteinizing agent exhibited minimal adverse effects on bonding to dentin in comparison with NaOCl solutions.

Effects of dentin surface preparations on bonding of self-etching adhesives under simulated pulpal pressure

  • Chantima Siriporananon;Pisol Senawongse;Vanthana Sattabanasuk;Natchalee Srimaneekarn;Hidehiko Sano;Pipop Saikaew
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.4.1-4.13
    • /
    • 2022
  • Objectives: This study evaluated the effects of different smear layer preparations on the dentin permeability and microtensile bond strength (µTBS) of 2 self-etching adhesives (Clearfil SE Bond [CSE] and Clearfil Tri-S Bond Universal [CTS]) under dynamic pulpal pressure. Materials and Methods: Human third molars were cut into crown segments. The dentin surfaces were prepared using 4 armamentaria: 600-grit SiC paper, coarse diamond burs, superfine diamond burs, and carbide burs. The pulp chamber of each crown segment was connected to a dynamic intra-pulpal pressure simulation apparatus, and the permeability test was done under a pressure of 15 cmH2O. The relative permeability (%P) was evaluated on the smear layer-covered and bonded dentin surfaces. The teeth were bonded to either of the adhesives under pulpal pressure simulation, and cut into sticks after 24 hours water storage for the µTBS test. The resin-dentin interface and nanoleakage observations were performed using a scanning electron microscope. Statistical comparisons were done using analysis of variance and post hoc tests. Results: Only the method of surface preparation had a significant effect on permeability (p < 0.05). The smear layers created by the carbide and superfine diamond burs yielded the lowest permeability. CSE demonstrated a higher µTBS, with these values in the superfine diamond and carbide bur groups being the highest. Microscopic evaluation of the resin-dentin interface revealed nanoleakage in the coarse diamond bur and SiC paper groups for both adhesives. Conclusions: Superfine diamond and carbide burs can be recommended for dentin preparation with the use of 2-step CSE.

2,2-Bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane을 함유한 상아질 접착레진의 물성이 접착강도에 미치는 영향 (The effect of the strength and wetting characteristics of Bis-GMA/TEGDMA-based adhesives on the bond strength to dentin)

  • 박은숙;김창근;배지현;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권2호
    • /
    • pp.139-148
    • /
    • 2011
  • 연구목적: 치과용 접착제에서 기저단량체로 사용되는 Bis-GMA를 Bis-M-GMA로 대체한 접착레진이, Bis-GMA/TEGDMA 를 사용한 접착제와 비교할 만한 물성과 접착강도를 가지는지 알아보고자 하였다. 연구 재료 및 방법: 다양한 구성비의 Bis-GMA, Bis-M-GMA 및 TEGDMA 를 함유한 접착레진을 제작하여, 점도(${\eta}$), 중합률(DC) 및 굴곡강도(FS)를 측정하고, 상아질에 대한 미세인장접착강도(MTBS)를 측정하였다. 해석을 위해 각 단량체들의 용해도 상수(${\delta}_t$)를 비교하였고, 접착계면을 주사전자현미경으로 관찰하였다. 결과: Bis-M-GMA의 점도는 3.65 Pa s로 크게 감소하였다. Bis-GMA를 함유하지 않는 접착레진은 Bis-GMA를 함유한 접착레진에 비해 낮은 굴곡강도를 보였다(p < 0.05). TEGDMA 함량이 낮은 접착레진은 TEGDMA 함량이 높은 접착레진에 비해 낮은 미세인장접착강도를 보였으며(p < 0.05), 주사전자현미경 사진에서 균열이나 틈이 관찰되었다. 결론: 높은 접착강도를 얻기 위해서는 접착레진의 높은 굴곡강도와 초기 중합률 뿐 아니라, 접착레진과 primer 처리 된 상아질 사이의 용해도 상수의 적합성도 요구되었다.

상아세관의 주행방향에 따른 상아질 접착제의 침투양상에 대한 공초점레이저주사현미경 연구 (EFFECT OF DENTINAL TUBULES ORIENTATION ON PENETRATION PATTERN OF DENTIN ADHESIVES USING CONFOCAL LASER SCANNING MICROSCOPY)

  • 김동준;황윤찬;김선호;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.392-401
    • /
    • 2003
  • The purpose of this study was to evaluate the penetration pattern of dentin adhesives according to the orientation of dentinal tubules with confocal laser scanning microscopy. Specimens having perpendicular. parallel and oblique surface to dentinal tubules were fabricated. The primer of dentin adhesives (ALL $BOND^{\circledR}{\;}2,{\;}CLEARFIL^{TM}$ SE BOND and PQ1) was mixed with fluorescent material. rhodamine B isothio-cyanate (Aldrich Cherm. CO., Milw., USA), It was applied to the specimens according to the instructions of manufactures. The specimens were covered with composite resin (Estelite, shade A2) and then cut to a thickness of 500$\mu\textrm{m}$ with low speed saw (Isomet^{TM}, Buehler. USA). The adhesive pattern of dentin adhesives were observed by fluorescence image using confocal laser scanning microscopy. The results were as follows. 1. For the groups with tubules perpendicular to bonded surface. funnel shape of resin tag was observed in all specimen. However. resin tags were more prominent in phosphoric acid etching system (ALL $BOND^{\circledR}$ 2 and PQ1) than self etching system ($CLEARFIL^{TM}$ SE BOND). 2. For the groups with tubules parallel to bonded surface. rhodamine-labeled primer penetrated into peritubular dentin parallel to the orientation of dentinal tubules. But rhodamine-labeled primer of PQ1 diffused more radially into surrounding intertubular dentin than other dentin adhesive systems. 3. For the groups with tubules oblique to bonded surface. resin tags appeared irregular and discontinuous. But they penetrated deeper into dentinal tubules than other groups.

Self-Priming Adhesives를 침투시킨 탈회 상아질의 인장강도 (Tensile Strengths of Demineralized Dentin derived from Self-Priming Adhesives)

  • 이혜윤;윤미란;이린;이정;이광원
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.181-191
    • /
    • 2006
  • The objectives of this study were to evaluate the tensile strength of resin-infiltrated demineralized dentin according to the demineralization time, and to evaluate the tensile strength of hybrid layer that is formed by infiltrating different priming adhesives or primer/adhesive into demineralizd dentin matrix. Seventy five hour-glass shaped dentin specimens were prepared in mid-coronal dentin from extracted human molars. Thirty specimens were distributed into three groups according to demineralization time - 2 hours, 4 hours and 8 hours. Each specimen was placed in primer/adhesive of All-Bond 2 for 5 hours of infiltration. Another forty-five specimens of them were demineralized in 37% phosphoric acid for 4 hours. They were randomly assigned to three experimental groups - AB, SB and OS - to designate All-Bond 2, Single Bond and One-Step. Each specimen was placed in one of three different adhesives for 5 hours of infiltration. The specimens were visible light-cured for 5 minutes, and then stored for 24 hours in distilled water at $37^{\circ}C$. After that, microtensile bond strength for each specimen was measured, and the fractured surfaces were then observed by SEM. The data were statistically analysed by one-way ANOVA and Tukey's multiple comparison test and Bonferroni's multiple comparison test. The results were as follows; 1. Tensile strength of the group demineralized for 4 hours was significantly higher than that of groups demineralized for 2 hours and 8 hours (P < .01). 3. Tensile strength of the AB group was significantly higher than that of the SB group and OS group (P < .01).

자가부식형 상아질접착제와 레진시멘트와의 적합성에 관한 연구 (COMPATIBILITY OF SELF-ETCHING DENTIN ADHESIVES WITH RESIN LUTING CEMENTS)

  • 김도완;박상진;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.493-504
    • /
    • 2005
  • 본 연구는 상아질 접착제와 레진 시멘트의 적합성 여부를 알아보고자 시행하였다. 발거한 제3대구치의 상아질 표면을 노출시킨 후 Tescera ATL 복합레진 시편을 상아질 접착제 [All Bond 2 (Bisco), Clearfil SE Bond (Kuraray), Adper Prompt L-POP (3M), One-Up Bond F (Tokuyama)]와 레진시멘트 [Choice (Bisco), Panavia F (Kuraray), RelyX ARC (3M), Bistite II DC (Tokuyama)]로 접착하고 미세인장 결합강도 및 주사전자 현미경 관찰을 시행한 결론은 다음과 같다. 1. Clearfil SE Bond와 All-Bond 2가 Prompt L-Pop과 One-Up Bond F 보다 높은 미세인장 결합강도를 보였다(p<0.05). 2. Clearfil SE Bond와 All-Bond 2 사용시 1-step 상아질 접착제보다 혼성층이 두껍고 레진 tag가 길었다.