• Title/Summary/Keyword: dental zirconia

검색결과 464건 처리시간 0.029초

단시간과 장시간의 소결방법에 따른 지르코니아의 굴곡 강도와 미세구조의 변화 (The effect of short and long duration sintering method on microstructure and flexural strength of zirconia)

  • 이하빈;이태희;김지환
    • 대한치과기공학회지
    • /
    • 제42권2호
    • /
    • pp.73-79
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the influence of short and long duration sintering on microstructure and flexural strength of zirconia. Methods: To conduct three-point bending test, Zirconia specimens are milled according to ISO 6872 guidelines(N=18, n=9 per group). Two specimens group(n=8) is sintered for 10 hours(Standard schedule) and 3 hours(Speed schedule) at the peak temperature of 1550℃ with silicon carbide sintering furnace. Flexural strength of specimens are measured by instron. After coating each specimen(n=1), microstructure of specimens is observed using Scanning Electron Microscope(SEM). T-test was utilized to statistically assess the data. Results: The mean and standard deviation value of the flexural strength for standard schedule group are 578.15±57.48Mpa, that of speed schedule are 465.9±62.34Mpa. T-test showed significant differences in flexural strength between two zirconia specimen group which applied standard schedule and speed schedule respectively(p<0.05). Conclusion: The result of this study showed that the increase in sintering time led to increased grain size, and also to a positive effect on the flexural strength.

용융침투법으로 제조한 인공치관용 스피넬/지르코니아-유리 복합체의 기계적 특성에 미치는 지르코니아 첨가효과 (Effect of Zirconia Addition on Mechanical Properties of Spinel/Zirconia-glass Dental Crown Composites Prepared by Melt-infiltration)

  • 이득용;김병수;장주웅;이명현;박일석;김대준
    • 한국세라믹학회지
    • /
    • 제39권11호
    • /
    • pp.1028-1034
    • /
    • 2002
  • 용융침투법을 이용 스피넬/지르코니아-유리 복합체를 제조하여 지르코니아 첨가가 복합체의 기계적 특성에 미치는 영향을 조사하였다. 유리 침투시간이 증가할수록 침투깊이는 Washburn식에 의한 포물선 관계로 증가하였으며 유리 침투상수 K는 기공 크기의 함수로 지르코니아 첨가량이 증가할수록 감소하였다. 지르코니아가 20 wt% 첨가되었을 때 스피넬/지르코니아-유리 복합체의 최적의 강도값(308 MPa)이 관찰되었지만 지르코니아 양이 증가함에 따라 유리 침투 상수와 투과율(transmittance)이 감소하였다. 지르코니아 첨가가 스피넬/지르코니아-유리 복합체의 기계적 특성 향상에 미치는 증진 효과는 크지 않은 것으로 관찰되었다.

지르코니아 표면 에칭처리 효과에 따른 레진 및 도재의 결합강도 (Bonding strength of resin and porcelain depending on the effects of zirconia surface etching)

  • 박영대;한석윤
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.243-251
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of etching by monitoring the etched surfaces and the shear bonding strength of resin and porcelain with etched zirconia. Methods: The CAD/CAM was used to produce 24 zirconia blocks in groups of six. The zirconia specimen surfaces were sandblasted, and they were then divided into 12 specimens with surface etching and 12 specimens without etching for the control group. 12 specimens of composite resin were bonded using a curing light, and 12 specimens of porcelain underwent vita porcelain build-up sintering and the shear bonding strength was measured using a universal testing system. The SEM photographs were taken in order to observe any differences in the surfaces before and after etching, and they were magnified by a factor of 8 in order to observe fractured surface types. Results: The results of the shear bonding strength measurements are as follows: For the composite resin tests, between zirconia and resin, the shear bonding strength of the control group (NZR) without surface etching was 4.68 Mpa and the experimental group (EZC) with surface etching was 9.65 Mpa, which is significantly higher. The crystal structure of the zirconia was confirmed to be different in observations of the surfaces before and after etching. Conclusion : In comparing the shear bonding strength of zirconia and composite resin, the effects of etching were found to be significant. The effects of surface etching were also observed in fractured surfaces between zirconia and porcelain. This is expected to be applicable to various prosthetics as surface etching on zirconia is used in clinics.

유리침투 지르코니아 복합체의 굴곡 강도 (Flexure Strength of Glass-infiltrated Zirconia Complex)

  • 김사학
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, to improve the flexure strength of Zirconia, on the Zirconia pellet surface measure the flexure strength to melt or permeate the Alumina (Vita Zahnfabrik, Bad Sachkingen, Germany) of private used In-Cream and observe by Scanning election microscope. In the control group(3Y-TZP group), the average of flexure strength was 1623.7MPa, and in the experimental group(Glass-infiltrated 3Y-TZP group) was 1800.2MPa. As a result of observing the interface between glass and zirconia with a scanning election microscope, it was showed that the glass dissolves to permeate into the surface of zirconia, so filled the zirconia with particles.

  • PDF

심미도재관의 파절 강도 비교 연구 (A comparative study on the fracture strength of esthetic porcelain crowns)

  • 김은하;이명곤
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.79-85
    • /
    • 2007
  • In this study, We tried to find out the fracture strength of zirconia coping all ceramic crown and collarless porcelain fused gold alloy crown as the compared group. Each of the collarless porcelain fused gold crown and zirconia all ceramic crown has been produced specimen 10 each. And after pasting them on the steel jig, it had load given at porcelain incisal edge by 130$^{\circ}$ and measured fracture strength by Universal Testing Machine and then We have results from that. 1. The average value of fracture strength suggested 950.49 N at collarless porcelain fused gold alloy crown, 656.81 N at zirconia coping all ceramic crown. 2. Fractured pattern showed that the whole of labial part was exposed in collarless porcelain fused gold crown, but porcelain of margin part did not show fracture in advance. In the practice, the concern that collarless might cause fracture strength to be weaken does not matter, we concluded zirconia all ceramic crown made fracture that only a part of labial porcelain was fractured. The combination of zirconia all ceramic crown and turned out to be excellent.

  • PDF

샌드블라스팅 처리와 라이너가 지르코니아와 전장도재의 전단결합 강도에 미치는 영향 (Effect of sandblasting and liner on shear bond strength of veneering ceramic to zirconia)

  • 김기백;김재홍
    • 대한치과기공학회지
    • /
    • 제43권1호
    • /
    • pp.6-12
    • /
    • 2021
  • Purpose: This study aimed to compare the shear bond strength between zirconia cores and veneer ceramics as per the sand blasting and liner treatments. Methods: The following 4 groups of zirconia-veneering ceramic specimens were prepared: (1) Group I, untreated; (2) Group II, with 110 ㎛ aluminium oxide (Al2O3) sandblasting; (3) Group III, with liner (IPS e.max ZirLiner; Ivoclar Vivadent); and (4) Group IV, with 110 ㎛ Al2O3 sand blasting and liner. Surface roughness was measured for all the prepared specimens, and the surface morphology was observed using a scanning electron microscope. All the samples (n=40) were fixed with measuring jigs, and shear bond strengths were obtained using a universal testing machine with a crosshead speed of 0.5 mm/min. The shear bond strength data were analyzed using one-way analysis of variance and t-test. The post hoc comparison was performed using the Tukey's test (α=0.05). Results: A significant difference in the surface roughness was observed between the specimens of groups I and II (p<0.05). Surface treatment with liner and sandblasting showed higher shear bond strength between zirconia core and veneering ceramic (p<0.05). Conclusion: The sand blasting and liner treatment increased the shear bond strength between zirconia core and veneering ceramic.

Effect of different coloring liquids on the flexural strength of multilayered zirconia

  • Yu, Na-Kyoung;Park, Mi-Gyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.209-214
    • /
    • 2019
  • PURPOSE. The purpose of this study was to evaluate the effect of two coloring liquids (aqueous and acid-based coloring liquids) and the position of multilayered zirconia on the flexural strength of multilayered zirconia. MATERIALS AND METHODS. The multilayered zirconia specimens were divided into upper and lower positions. The specimens were divided into three subgroups (n=10): non-shaded, acid-based coloring liquid, and aqueous coloring liquid. The specimens were cut using a milling machine and were immersed in either a acid-based coloring liquid or aqueous coloring liquid 2 times for 5 seconds. The specimens were sintered in a sintering furnace according to the manufacturer's introduction. The flexural strength of the specimen was measured using a universal testing machine and the surface of the specimen was observed using a field emission scanning electron microscope. RESULTS. The flexural strength of multilayered zirconia was 400 - 500 MPa. There was no statistically significant difference among all groups (P>.05).The flexural strength of the multilayered zirconia was not influenced by the kind of coloring liquid used (P>.05). The flexural strength of the multilayered zirconia colored with the coloring liquids was not influenced by its position (P>.05). CONCLUSION. The different coloring liquid application did not affect the flexural strength of multilayered zirconia of all positions.

Cytotoxicity and biocompatibility of Zirconia (Y-TZP) posts with various dental cements

  • Shin, Hyeongsoon;Ko, Hyunjung;Kim, Miri
    • Restorative Dentistry and Endodontics
    • /
    • 제41권3호
    • /
    • pp.167-175
    • /
    • 2016
  • Objectives: Endodontically treated teeth with insufficient tooth structure are often restored with esthetic restorations. This study evaluated the cytotoxicity and biological effects of yttria partially stabilized zirconia (Y-TZP) blocks in combination with several dental cements. Materials and Methods: Pairs of zirconia cylinders with medium alone or cemented with three types of dental cement including RelyX U200 (3M ESPE), FujiCEM 2 (GC), and Panavia F 2.0 (Kuraray) were incubated in medium for 14 days. The cytotoxicity of each supernatant was determined using 3-(4,5-dimethylthiazole- 2-yl)-2,5-diphenyltetrazolium bromide (MTT) assays on L929 fibroblasts and MC3T3-E1 osteoblasts. The levels of interleukin-6 (IL-6) mRNA were evaluated by reverse transcription polymerase chain reaction (RT-PCR), and IL-6 protein was evaluated by enzyme-linked immunosorbent assays (ELISA). The data were analyzed using one-way ANOVA and Tukey post-hoc tests. A p < 0.05 was considered statistically significant. Results: The MTT assays showed that MC3T3-E1 osteoblasts were more susceptible to dental cements than L929 fibroblasts. The resin based dental cements increased IL-6 expression in L929 cells, but reduced IL-6 expression in MC3T3-E1 cells. Conclusions: Zirconia alone or blocks cemented with dental cement showed acceptable biocompatibilities. The results showed resin-modified glass-ionomer based cement less produced inflammatory cytokines than other self-adhesive resin-based cements. Furthermore, osteoblasts were more susceptible than fibroblasts to the biological effects of dental cement.

Metal stain on monolithic zirconia restoration: A case report

  • Cha, Min-Sang;Lee, Sang-Woon;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.138-142
    • /
    • 2017
  • In restorative treatment using fixed dental prostheses, dentists should select appropriate restoration material among various types of dental materials. The strength, marginal fit, esthetics, wear resistance, biocompatibility, and cost are important factors in the choice of restoration materials. The present case showed a surface stain on a monolithic zirconia restoration that was due to wear between the monolithic zirconia restoration and the base metal alloy restoration. This phenomenon was confirmed by surface roughness measurement and electron probe micro-analysis.

The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading

  • Tang, Yu Lung;Kim, Jee-Hwan;Shim, June-Sung;Kim, Sunjai
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.152-158
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS. Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconia-ceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS. No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION. The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.