• 제목/요약/키워드: dental restoration failure

검색결과 63건 처리시간 0.021초

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

  • Kim, Sung-Beom;Kim, Young-Kyun;Kim, Su-Gwan;Oh, Ji-Su;Kim, Byung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권6호
    • /
    • pp.247-252
    • /
    • 2014
  • Purpose: This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. Methods: This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to four months and in the mandible within one to two months. The types of restoration were single crown and fixed partial prosthesis. Those functioned over one year. The implants were classified by the surface of implants as Group 1: RBM surface (GS III; OSSTEM, Busan, Korea) and, Group 2: SLA surface (Superline; Dentium, Seoul, Korea). The groups were categorized by maxilla and mandible and compared by survival rate, marginal bone loss through clinical records evaluation, and radiographic measurements. Results: The marginal bone loss in the maxilla was $0.14{\pm}0.34mm$ (Group 1) and $0.30{\pm}0.37mm$ (Group 2), a statistically significant difference (P<0.05). In the mandible those were $0.28{\pm}0.54mm$ (Group 1) and $0.20{\pm}0.33mm$ (Group 2), not significant (P>0.05). There was no significant difference of marginal bone loss between maxilla and mandible by groups. During observation there was no implant failure, a survival rate of 100%. Conclusion: Both surfaces showed an excellent survival rate, and the marginal bone loss was not substantial.

포스트 접착 시멘트의 종류와 적용 방법에 따른 접착 효율 비교 (Comparison of the post cementation efficacy using different cements and methods)

  • 조옥인;이상진;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제48권9호
    • /
    • pp.680-687
    • /
    • 2010
  • The purpose of this study was to compare post cementation efficacy according to the different adhesive systems and cement delivery methods. A total of 40 extracted human single-rooted premolar teeth were randomly divided in four groups according to the two luting agents of Unicem applicap (3M ESPE, St. Paul, MN, USA) or Variolink II (Ivoclar Vivadent, Liechtenstein) and cement delivery methods of direct cement application or lentulo spiral application. After restoration using glass?fiber posts, the samples were embedded in acrylic resin. Three sections of 2 mm thickness were prepared from each specimen, and the post in each section was subjected to a push-out test. The data were analysed statistically at significant level of 95%. The Unicem had significantly higher push-out bond strength than Variolink and the lentulo spiral application made higher bond strength (p<0.05). Adhesive failure between cement and dentin was predominant in all groups. The Unicem of self-etch system and cement delivery using lentulo spiral showed clinically acceptable and comparable bonding strength for the fiber post.

CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도 (Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems)

  • 강후원;김희진;김장주;고명원
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).

Enamel Microabrasion을 시행한 법랑질과 복합레진의 전단결합강도 (SHEAR BOND STRENGTH OF COMPOSITE RESIN TO ENAMEL FOLLOWING ENAMEL MICROABRASION)

  • 홍기상;이상대;이상훈
    • 대한소아치과학회지
    • /
    • 제27권1호
    • /
    • pp.45-53
    • /
    • 2000
  • Enamel microabrasion은 염산과 연마제를 사용하여 치아의 착색을 제거하는 술식으로서, 그 효과는 법랑질 표층에 국한된다. Enamel microabrasion으로 모든 착색이 치료 가능한 것은 아니므로, 착색이 깊을 경우에는 microabrasion 후에도 제거되지 않고 남은 착색부위를 광중합 복합레진을 사용해 수복할 것이 권장된다. 본 연구의 목적은 enamel microabrasion의 방법과 시간이 법랑질에 대한 복합레진의 전단결합강도에 미치는 영향을 조사하는 것이었다. 아무런 처치도 하지 않은 대조군을 1군으로 하였고, 18% 염산과 fine pumice의 혼합물을 hand applicator로 치면에 5초씩 5, 10회 적용시킨 것을 각각 2, 3군으로 하였다. 10% 염산과 연마제의 혼합물인 기성품 PREMA를 10 : 1 gear reduction handpiece로 20초씩 5, 10회 적용시킨 것을 각각 4, 5군으로 하였다 여기에 37% 인산으로 부식 후 복합레진을 결합시켜 thermocycling 후 전단결합강도를 측정하여 다음과 같은 결론을 얻었다. 1. 2군이 가장 높은 결합강도$(24.36{\pm}3.34MPa)$를 나타내었고, 3군이 가장 낮은 결합강도$(19.35{\pm}3.43MPa)$를 보였다. 전단결합강도는 2>4>5>1>3군의 순서로 감소하였다. 2. 2군은 1군과 3군보다 통계학적으로 유의성 있게 높은 결합강도를 나타내었다(p<0.05). 3. 염산과 pumice로 enamel microabrasion을 시행한 2, 3군과 PREMA를 사용한 4, 5군 사이에는 유의한 결합강도의 차이가 없었다(p>0.05). 4. 파절면 검사에서, adhesive failure는 3, 4군에서 나타났고, cohesive failure는 1, 2, 3, 4군에서 관찰되었다. 5군에서는 mixed failure만이 관찰되었다. 5. SEM 관찰에서, 염산과 pumice로 enamel microabrasion을 시행한 2, 3군에서는 인산으로 부식한 것과 비슷한 표면 양상이 관찰되었고, PREMA로 처리한 4, 5군에서는 1군과 흡사한 매끈한 표면양상이 관찰되었다. 각 군의 시편을 인산으로 부식시킨 다음에는 전형적인 산부식 후의 표면양상이 관찰되었고, 군간 별다른 차이가 없었다.

  • PDF

반복주조된 치과용 합금의 피착면 처리방법에 따른 접착성 수지와의 접착강도에 관한 실험적 연구 (AN EXPERIMENT STUDY ON THE BOND STRENGTH OF ADHESIVE RESINS TO SUEEXSSIVELY RECAST ALLOYS FOR REISN-BONDED RESTORATIONS)

  • 정금태;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.53-76
    • /
    • 1990
  • The purpose of this study was to evaluate the tensile bond strength of adhesive resins to successively recast Rexillium III and Degudent-U. Recasting was done 4times successively. Specimen $A_1$, were cast by new metal, and $A_2$ by surpus of $A_1$, $A_3$ by surplus of, $A_2$ $A_4$ by surplus of $A_3$, $A_5$ by surplus of $A_4$ plus 50% new metal. The types of surface treatment for resinbonded restoration in this experiment were electrolytic etching by OXY-ETCH(Oxy dental products, Inc., Hillside, New Jersey, U.S,A.), aluminum oxide blasting, anodic oxidation by EZ-OXISOR( Towagiken Co., Kyoto, Japan), electrotinplating by Kura Ace(Kuralay Co., Kyoto, Japan). Three kinds of cementing resin used in this study were Comspan(K.P. Cauil Co, Milford Delaware, U.S.A.), Super Bond C&B(Sun-Medical Co. Ltd., Kyoto,Japan), Panavia EX(Kuralay Co., Ltd., Osaka, Japan). Tensile bond strength was measured by Instron Universal testing machineModel 1125) and all the specimen were observed with SEM(JEOL, JSM-T2000) and mode of bond failure were recorded. The obtained results were as follows : 1. In electrolytic etched group, tensile bond strength was decreassed when recast alloy was used, and tensile bond strength of Compan and panavia EX were not significantly different(P>0.05). 2. In remaining group treated by aluminum oxide blasting, EZ-OXIOR, Kura Ace, tensile bond strength were not changed when recast alloy were used, and tensile bond strength of SuperBond(C&B and Panavia EX were not significantly different(P>0.05). 3. IN SEM evaluation, electrolytic etched group and electrotinplated group exhibited different image when recast alloy was used, and remaining groups treated by aluminum oxide blasting, EZ-OXISOR exhibited the same. 4. IN observation of bond failure, electrolytic etched group exhibited adhesive failure and remaing groups treated by aluminium oxid blasting, EZ-OXISOR, Kura Ace exhibited adhesive and cohesive failure.

  • PDF

2% 클로르헥시딘 적용이 한 단계 자가부식 접착제를 이용한 복합 레진의 상아질에 대한 미세인장 결합강도에 미치는 효과 (Effect of 2% chlorhexidine application on microtensile bond strength of resin composite to dentin using one-step self-etch adhesives)

  • 장순함;허복;김현철;권용훈;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.486-491
    • /
    • 2010
  • 연구목적: 이 연구의 목적은 2% 클로르헥시딘 적용이 한 단계 자가부식접착제를 이용한 직접 복합 레진 수복의 미세 인장 강도에 미치는 영향을 평가하는 것이었다. 연구 재료 및 방법: 24개의 발거된 대구치를 사용하여 3종류의 한 단계 자가부식접착제 (Clearfil $S^3$ Bond, Xeno V, G-Bond) 를 클로르헥시딘을 적용한 그룹과 적용하지 않은 그룹, 총 6개의 그룹으로 나누었다. 클로르헥시딘을 적용하거나 적용하지 않고 그 상부에 각각의 접착제를 적용하고 광중합 복합 레진으로 수복하였다. 24시간 동안 실온의 증류수에 보관한 후 각 그룹당 10개의 시편을 준비 하여 모든 시편의 미세인장 결합 강도를 측정하였다. 결과: 2% 클로르헥시딘 적용이 한 단계 자가부식접착제를 이용한 복합레진 수복의 미세인장 결합강도에 영향을 미치지 않았다. 클로르헥시딘 적용과 상관없이 Clearfil $S^3$ Bond가 가장 높은 미세인장 결합강도 값을 나타내었고 그 다음은 GBond, Xeno V 순이었다. 파절 양상은 대부분 접착성 파절을 보였고 일부는 응집성 파절을 보였다. 결론: 2% 클로르헥시딘 적용이 한 단계 자가부식접착제를 이용한 복합레진 수복의 미세인장 결합강도에 영향을 미치지 않았다.

치과용도재에 의한 법랑질 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF DENTAL PORCELAINS AND HUMAN ENAMEL)

  • 이영국;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.51-70
    • /
    • 1999
  • Dental porcelain is one of the materials of choice for restoration where esthetics is of concern, but has a considerable potentials of wear. The wear of enamel is variable when opposed by different porcelain systems and surface conditions, and the exposed dentine and opaque porcelain due to clinical failure is expected to have high potentials of wear. The purpose of this study was to investigate the wear effects of self-glazed, polished incisal porcelain. polished dentine and opaque porcelain against human enamel in the laboratory by use of a pin-on-disk type wear tester. 4 types of dental porcelain($Vita-{\Omega}$, Ceramco-II, Vintage powder $Vita-{\alpha}$ of In-Ceram system) and type IV gold alloy as cotrol group were used for test specimens. Intact buccal cusps of maxillary premolar were used for enamel specimens, and the cusp converged to a point and was devoid of visible abrasion, caries, decalcification. The upper part was the cusp of a maxillary premolar and the lower part was a porcelain specimen. The enamel wear was deter-mined by weighing the cusp before and after each test. Surface profilometer was used to quantitate wear of the porcelain specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows : 1 Self-glazed porcelain produced more enamel wear than polished porcelain, especially the enamel wear of $Vita-{\alpha}$ self-glazed porcelain was 3.2 times more than that of other groups. 2. Opaque porcelain produced least porcelain wear, $Vita-{\alpha}$ self-glazed porcelain produce greatest porcelain wear, but there was no statistically significant difference between the groups(p>0.05). 3. The enamel wear of dentine porcelain was 3.8 times more than that of polished inisal porcelain(p<0.05), and the enamel wear of opaque porcelain was 1.9 times more than that of polished inisal porcelain, but there was no statistically significant difference between the groups(p>0.05) 4. Overglazed porcelain produced less enamel wear than self-glazed porcelain, and more enamel wear than polished porcelain, but there was no statistically significant difference between the groups(P>0.05). 5. The hardness number of $Vita-{\Omega}$ dentine and Ceramco-II opaque porcelain was larger, but that of Vintage dentine and $Vita-{\alpha}$ self-glazed porcelain was similar to other groups. 6. Examination of SEM photographs revealed that overglazed porcelain had smoother surface than self-glazed porcelain, and self-glazed porcelain had smoother surface than polished porcelain. Much polishing scratches and larger porosities were observed on the opaque porcelain specimen, and much polishing scratchess and small porosities were observed on the dentine porcelain specimen.

  • PDF

임플란트 배열과 하중 방향이 임플란트와 치조골에 미치는 유한요소 응력분석 (Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis)

  • 정현주;박찬;윤귀덕;임현필;박상원;양홍서
    • 구강회복응용과학지
    • /
    • 제36권3호
    • /
    • pp.176-182
    • /
    • 2020
  • 목적: 수복물에 교합력을 가할때 식립된 임플란트의 개수, 배열 및 위치에 따른 임플란트, 보철물 및 지지 골에 발생하는 응력의 차이를 분석하고자 한다. 연구 재료 및 방법: 하악에 임플란트가 식립되어 고정성 보철물을 지지하는 4 종류의 3D 유한요소 모형을 제작하였다. 모델 M1은 2개의 임플란트 가운데에 가공치를 배열하였고, 모델 M2는 2개의 임플란트 외측에 캔티레버 가공치를 배열하였다. 모델 M3과 M4는 3개의 임플란트를 각각 일렬로 배열되거나, 엇갈리게 배열하였다. 총 120 N 크기의 수직력과 45도 측방력을 가하였고, 유한요소 응력 분석을 시행하였다 결과: 측방력 하중에 의해 발생한 최대 응력은 수직력 하중에 의한 것 보다 임플란트 부위에서 3.4 - 5.1배 더 컸고, 지지골 내에서는 3.5 - 8.3배 더 컸다. 모델 M2 의 고정성 보철물의 캔티레버 연결부에서 가장 큰 응력이 집중되었다. 임플란트 개수가 3개인 모델들이 2개인 경우보다 더 낮은 응력이 발생하였으나 M3과 M4에서 일렬 배열과 엇갈린 배열간의 응력 발생 차이는 작았다. 결론: 임플란트 배열의 엇갈림 정도는 응력 크기에 별 차이를 발생하지 않았으나, 캔티래버의 존재나 임플란트의 개수의 차이는 큰 영향을 주었다.

두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교 (Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations)

  • 신호식;김석규
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.528-534
    • /
    • 2008
  • 연구목적: 변연적합도는 보철수복물의 성공을 좌우하는 중요한 요소 중의 하나이다. McLean과 von Fraunhofer등에 의하면 120 ${\mu}m$ 이하를 임상적으로 허용할 수 있다고 했는데, 이를 넘는 정확하지 않은 변연은 지각과민을 일으키거나 이차 우식을 일으키고, 치태 축적을 용이하게 하여 보철물의 수명을 단축시키게 된다. 이에 최근에 우리나라에 소개되어 임상적으로 사용되고 있는 CAD-CAM 전부도재 수복물 중 $LAVA^{(R)}$ 시스템 (3M ESPE, St. Paul, MN)과 $EVEREST^{(R)}$ 시스템 (KaVo Dental GmbH, Biberach, Germany)으로 제작한 지르코니아 전부 도재관들이 도재전장 금속주조 수복물과 비교해 보아 코핑 상태일 때와 도재축성 후 각각 변연적합도의 차이가 있는지를 살펴보고자 하였다. 재료와 방법: 상악 제1소구치 덴티폼 치아를 high speed diamond bur 로 교합면 2.0 mm, 순설면 1.0 mm, 그리고 변연은 chamfer margin을 6도 측면 경사 절삭 기계로 균일하게 제작해서 이를 인상 채득하여 금속 지대치를 제작하였다. 이를 덴티폼 모형상에 장착한 후 전악인상을 채득하여 $LAVA^{(R)}$ 수복물 코핑, $EVEREST^{(R)}$ 수복물 코핑, 그리고 도재전장 금속주조 수복물 코핑을 각각 8개씩 제작하였다. 이들 코핑을 염색제를 섞은 Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan)를 이용하여 금속 지대치에 접합시킨 뒤, $Microhiscope^{(R)}$ system (HIROX KH-1000 ING Plus, Seoul, Korea)을 이용하여 300배율로 관찰하면서 변연 간격을 ${\mu}m$단위로 측정하였다. 도재축성 후에도 마찬가지 방법으로 모든 수복물의 변연간격을 측정하여 통계 처리를 하였다. 결과: 코핑 상태에서의 평균 변연간격 값은 $EVEREST^{(R)}$ 에서 $52.00{\pm}11.94\;{\mu}m$, $LAVA^{(R)}$$ 56.97{\pm}10.00\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $97.38{\pm}18.54\;{\mu}m$를 보였고, 도재축성 후에 평균 변연 간격값은 $EVEREST^{(R)}$$61.69{\pm}19.33\;{\mu}m$, $LAVA^{(R)}$$70.81{\pm}12.99\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $115.25{\pm}23.86\;{\mu}m$를 보였다. 결론: 1. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물은 도재 전장 금속 주조 수복물과 비교하여 각각 코핑상태일 때와 도재 축성 후 모두 유의성 있는 (P < .05) 차이를 보이는 우수한 변연 적합도를 나타내었다. 2. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물 간의 평균 변연 간격 비교에서 코핑 상태일 때와 도재 축성 후에 모두 유의성 있는 차이는 없었다 (P > .05). 3. $LAVA^{(R)}$$EVEREST^{(R)}$ 그리고 PFM 은 각각 코어 상태일 때와 비교하여 도재 축성 후 변연 간격에서 약간 증가되었으나 유의성 있는 차이를 보이지는 않았다 (P > .05).

유구치 인접면 우식증 수복 시 지르코니아 전장관과 기성금속관의 생존율 비교 평가: 후향적 연구 (Comparative Evaluation of the Survival Rates of Zirconia Crown and Stainless Steel Crown for Proximal Caries in Primary Molars: a Retrospective Study)

  • 정가희;이난영;신혜원;박수현;지명관
    • 대한소아치과학회지
    • /
    • 제50권3호
    • /
    • pp.307-317
    • /
    • 2023
  • 심미성에 대한 요구가 증가함에 따라 유구치 수복을 위한 지르코니아 전장관은 더 활발하게 사용되고 있으나, 지르코니아 전장관으로 수복한 치아를 장기간 추적 관찰하거나 다른 재료와 비교한 연구는 많지 않다. 따라서 이 연구의 목적은 인접면 우식증에 대한 지르코니아 전장관과 기성금속관의 36개월 동안의 생존율을 비교하여 평가하고, 각 기성관의 수복 실패 양상을 분석하는 것이다. 2017년부터 2019년까지 조선대학교 치과병원 소아치과와 두 개의 개인 치과의원에 내원하여 두 기성관으로 수복 치료를 받은 498명 환자에 대한 1,061개의 유구치에 대한 전자의무기록지와 방사선 사진을 수집하고 분석하였다. 생존분석 결과, 기성금속관으로 수복한 치아의 생존율이 지르코니아 전장관에 비해 유의하게 높았다. 치수 치료 시행 여부를 나눠 생존 분석을 시행한 결과, 치수 치료를 시행하지 않은 경우, 기성금속관의 생존율이 지르코니아 전장관에 비해 유의하게 높았던 반면, 치수 치료를 시행한 경우에는 두 기성관의 생존율에 유의한 차이가 없었다. 기성금속관의 주된 수복실패 원인은 비정상적 치근 흡수 또는 치근단 투과상 병소의 발생이었고, 지르코니아 전장관의 경우 수복물의 탈락이었다. 이 연구는 임상가들에게 구치부 기성관 재료 선택 시 참고 자료로 활용될 수 있을 것이라 생각된다.