• 제목/요약/키워드: dental resin composite

검색결과 521건 처리시간 0.024초

기질레진 필러가 UTMA계 광중합형 복합레진의 파괴인성에 미친는 영향 (EFFECT OF RESIN AND FILLER TYPE ON THE FRACTURE TOUGHNESS OF UTMA-BASED LIGHT-CURED COMPOSITES)

  • 안연실;황수진;배태성;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.604-613
    • /
    • 1999
  • This study was performed to evaluate the effect of resin and filler type on the fracture toughness of light-activated composites. Experimental composites were prepared using urethane tetramethacrylate(UTMA) and bisphenol glycidylmethacrylate(Bis-GMA) monomers and five different types of silica fillers. Fracture toughness was measured by a single edge V-notched beam(SEVNB) method, which was discussed from ASTM E399-78. Rectangular bars of $2.5{\times}5{\times}26mm$ were prepared with experimental composites and a notch about 2.25mm deep was carved at the center of the long axis of the specimen using a dental diamond disk driven by a dental micro engine. The flexural test was carried out at a crosshead speed of 0.05mm/min and fracture surfaces were observed under scanning electron microscope. The results obtained were summarized as follows: 1. The fracture toughness values of UTMA-based composites were relatively higher than those of Bis-GMA-based composites. 2. The highest fracture toughness value was observed in the UTMA-based composite containing the $1.5{\mu}m$-spherical fillers. 3 Aging in the distilled water at $37^{\circ}C$ for 10 days showed the increase of fracture toughness, which was severer in the Bis-GMA-based composites than those of UTMA-based composites. 4. The AE amplitude occurring during the fracture toughness tests was the highest at the point of macroscopic fracture.

  • PDF

Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin

  • Singh, Payal;Nagpal, Rajni;Singh, Udai Pratap
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.188-199
    • /
    • 2017
  • Objectives: This in vitro study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin. Materials and Methods: Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups (n = 24) according to 5 different surface pre-treatments: No pre-treatment (control); 1M carbodiimide (EDC); 0.1% epigallocatechin-3-gallate (EGCG); 2% minocycline (MI); 10% sodium ascorbate (SA). After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE) was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter), which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS) evaluation at 24 hours (immediate) and remaining 10 samples were tested after 6 months (delayed). Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio-Wilk W test, 2-way analysis of variance (ANOVA), and post hoc Tukey's test. Results: At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only (p = 0.009). After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resindentin bond strength with no significant fall. Conclusions: Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

Influence of silver nanoparticles on resin-dentin bond strength durability in a self-etch and an etch-and-rinse adhesive system

  • Jowkar, Zahra;Shafiei, Fereshteh;Asadmanesh, Elham;Koohpeima, Fatemeh
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.13.1-13.9
    • /
    • 2019
  • Objectives: This study evaluated the effect of dentin pretreatment with silver nanoparticles (SNPs) and chlorhexidine (CHX) on the microshear bond strength (${\mu}SBS$) durability of different adhesives to dentin. Materials and Methods: Occlusal surfaces of 120 human molars were ground to expose flat dentin surfaces. The specimens were randomly assigned to six groups (n = 20). Three groups (A, B, and C) were bonded with Adper Single Bond 2 (SB) and the other groups (D, E, and F) were bonded with Clearfil SE Bond (SEB). Dentin was pretreated with CHX in groups B and E, and with SNPs in groups C and F. The specimens were restored with Z250 composite. Half of the bonded surfaces in each group underwent ${\mu}SBS$ testing after 24 hours and the other half was tested after 6 months of water storage. Results: SNP application was associated with a higher ${\mu}SBS$ than was observed in the CHX and control groups for SEB after 24 hours (p < 0.05). A significantly lower ${\mu}SBS$ was observed when no dentin pretreatment was applied compared to dentin pretreatment with CHX and SNPs for SB after 24 hours (p < 0.05). The ${\mu}SBS$ values of the 6-month specimens were significantly lower than those obtained from the 24-hour specimens for all groups (p < 0.05). This decrease was much more pronounced when both adhesives were used without any dentin pretreatment (p < 0.05). Conclusions: SNPs and CHX reduced the degradation of resin-dentin bonds over a 6-month period for both adhesive systems.

치과용 비귀금속 합금과 전장용 강화형 복합레진의 인장결합강도 (TENSILE BOND STRENGTH BETWEEN NON-PRECIOUS DENTAL ALLOY AND VENEERING REINFORCED COMPOSITE RESINS)

  • 양병덕;박주미;고석민;강건구
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.427-437
    • /
    • 2000
  • Recently the 2nd generation laboratory composite resins were introduced. Although the mechanical properties of these composite resins have been improved, there were some disadvantages such as discoloration, low abrasion resistance and debonding between metal and resin. The purpose of this study was to evaluate the tensile bond strength between non-pecious dental alloy(verabond) and four veneering reinforced composite resins ; Targis(Ivoclar Co., U.S.A.), Artglass(Kulzer CO., Germany), Sculpture(Jeneric Pentron Co., U.S.A.), and Estonia(Kurary Co., Japan). All test metal specimens were polished with #1,000 SiC paper, and sandblasted with $250{\mu}m$ aluminum oxide. After then. according to manufacturer's instructions metal adhesive primer and veneering resins were applied. All test specimens were divided into two groups. One group was dried in a desiccator at $25^{\circ}C$ for 3 days, the other group was subjected to thermal cycling($2,000{\times}$) in water($5/55^{\circ}C$). Tensile bond strength was measured using Instron Universal Testing machine and the fractured surface was examined under the naked eyes and scanning electron microscope. Within the limitations imposed in this study, the following conclusions can be drawn: 1. In no-thermal cycling groups, there were no significant differences between Estenia and VMK68 but there were significant differences between Targis, Artglass, Sculpture and VMK68(p<0.05). 2. In no-thermal cycling resin groups, the highest tensile bond strength was observed in Estenia and there were significant differences between Estenia and the other resins(p<0.05). 3. Before and after thermal cycling, there were significant differences in tensile bond strength of Targis and Artglass(p<0.05). The tensile bond strength of Artglass was decreased and that of Targis was increased. 4. In no-thermal cycling groups, Artglass showed mixed fracture modes(95%), but after thermal cycling, Artglass showed adhesive fracture modes(75%).

  • PDF

수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구 (THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION)

  • 박성호;노병덕;김모란;안현정
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF

광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향 (EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.263-272
    • /
    • 2001
  • 저광도 중합법, 펄스 지연 중합법, 초고광도 중합법 등의 광조사 방식이 광중합형 복합레진 수복물에서의 중합수축 응력에 미치는 영향을 알아보기 위해 in vitro에서 미세 누출 실험을 하였다. 80개의 발거된 소구치의 협측면에 5급 와동을 형성하고, 600mW/$cm^2$로 30초간 광조사하는 보통 광도 중합군, 300mW/$cm^2$로 60초간 광조사하는 저광도 중합군, 400mW/$cm^2$로 2초간 광조사하고 5분간 기다린 후 800mW/$cm^2$로 10초간 최종 중합시키는 펄스-지연 중합군, 그리고 1930mW/$cm^2$의 광도로 3초간 광조사하는 초고광도 중합군 등의 4개의 군으로 나누어 hybrid 형의 광중합복합레진을 충전하고 각 군의 방법대로 중합한 후, 변연의 0.5mm 외부에 nail varnish를 도포하고 37$^{\circ}C$, 2% metylene blue 용액에 24시간 동안 침적시켰다. 시편을 아크릴릭 레진에 매몰한 후 수복물의 중앙에서 종절단하여 입체현미경하에서 그 단면을 관찰한 후 법랑질과 상아질 변연으로 나누어 색소의 침투도를 측정하여 다음과 같은 결과를 얻었다. 1. 펄스 지연 중합군의 색소 침투도는 법랑질과 상아질 변연 모두에서 보통광도, 저광도 및 초고광도 중합군과 유의한 차이를 보이지 않았다(p>0.05). 2. 상아질 변연에서 초고광도 중합군은 보통광도 중합군과 저광도 중합군에 비해 유의하게 높은 색소 침투도를 보였다(p<0.05). 3. 법랑질 변연에서의 4개 군의 색소 침투도는 서로 유의한 차이를 보이지 않았다(p>0.05). 4. 모든 군에서 상아질 변연에서의 색소 침투도는 법랑질군에서의 색소 침투도에 비해 유의하게 높았다(p<0.05).

  • PDF

ORIGINAL ARTICLE - Adhesion of Streptococcus mutans and Streptococcus sobrinus to different types of self-ligating brackets

  • Yang, Pil-Seung;Yu, Yoon-Jeong;Cha, Jung-Yul;Hwang, Chung-Ju
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.394-406
    • /
    • 2012
  • Objective: The adhesion capabilities of different types of self-ligating brackets were measured with respect to Streptococcus mutans and Streptococcus sobrinus. Methods: Five types of self-ligating brackets (Clippy-C; Mini Clippy; Clarity-SL; Speed; Damon 3) were used for the experiment group and composite resin brackets (Spirit-MB), metal brackets (Victory) and polycrystalline alumina brackets (Clarity) were used for the control group. In order to assess adhesion of bacteria to the brackets, the brackets were cultured for 3, 6 and 24 hours in media containing bacteria and 20% sucrose. Results: There was no statistic difference in adhesion amount of Streptococcus mutans and Streptococcus sobrinus according to the types of brackets. A total adhesion amount according to bracket type was different. An extended incubation time increased adhesion amount. Observation under scanning electron microscope showed that Streptococcus sobrinus adhered more to Clippy-C and Victory rather than to Clarity-SL. Conclusions: Clarity-SL, a self-ligating esthetic bracket was confirmed to show lower bacterial adhesion to cariogenic bacteria, Streptococcus mutans and Streptococcus sobrinus group than other self-ligating brackets or conventional brackets, which suggests that proper use of self-ligating esthetic brackets might even be better in preventing tooth surface decalcification.

임상가를 위한 특집 2 - 심미 수복 - 같은 결과, 다른 접근 세라믹을 이용한 전통적인 접근법 (Traditional approach with ceramic)

  • 이승규
    • 대한치과의사협회지
    • /
    • 제51권11호
    • /
    • pp.595-603
    • /
    • 2013
  • The requirements for the successful treatment of all-ceramic restorations are not so different from the ones of conventional restorations. "The provisional restoration followed by an adequate tooth reduction and the accurately fitting prostheses with corresponding to final impression" can be the examples of them. Nevertheless, the one which all-ceramic restorations are distinguished from conventional restorations is the additional procedure of so called "bonding". In addition to the application of resin cement between "inner surface of restoration and outer surface of abutment", bonding technology can be also applied to the treatment process of "Post and Core" in particular if the abutments are non-vital teeth. Core build-up for all-ceramic crown is conducted with fiber post and tooth colored composite by considering the properties of the restorations transmitting light. We know well that a vital abutment is easier than a non-vital one to get the targeted goals for clinical success in connection with esthetics and structure. The creation of "Post and Core" with bonding technique is a decisive factor for a long-term success if the abutment is non-vital tooth with dentinal collapse. I would like to share my clinical experience about "post & core build-up and all-ceramic restoration bonding" out of several success strategies of all-ceramic crown with this presentation.

화학-기계적 우식 제거법을 이용한 유구치 우식의 치료: 증례보고 (CHEMO-MECHANICAL REMOVAL OF CARIES IN PRIMARY MOLAR: REPORT OF 2 CASES)

  • 이혁상;이재천;김영재;김정욱;김종철;장기택
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.299-303
    • /
    • 2004
  • 전통적인 bur에 의한 우식치질의 삭제는 진동과 열에 의한 자극을 초래하기 때문에 아이들은 치과에 가는 것을 무서워한다. 최근 전통적인 방법을 대체하는 방법을 개발하려는 노력이 이루어져 왔고, 화학-기계적인 우식 제거법 역시 이러한 시도 중 하나이다. $Carisolv^{TM}$는 세가지 아미노산과 낮은 농도의 sodium hypochlorite, 그리고 특별하게 고안된 수 기구로 구성된 제품이다. 본 증례는 $Carisolv^{TM}$로 치료한 두 증례를 보고한다. 우식 상아질을 $Carisolv^{TM}$ gel과 기구로 제거하고 복합레진으로 수복하였다.

  • PDF

레진 시멘트의 혼합 후 시간에 따른 피막도의 변화 (Effect of working time on the film thickness of dental resin cements)

  • 이유승;김성훈;이재봉;한중석;여인성;하승룡;김희경
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.325-329
    • /
    • 2015
  • 목적: 본 연구에서는 임상에서 사용되는 몇 가지 레진 시멘트의 혼합 후 부하를 가하기까지의 시간에 따른 피막도의 변화를 비교하고, 혼합 후 작업 시간과 레진 시멘트의 피막도의 관계를 알아 보고자 하였다. 재료 및 방법: 네 종류의 레진 시멘트(Panavia F2.0, Clearfil SA Luting, Zirconite, RelyX U200)를 제조사의 지시대로 혼합한 후 두 장의 투명한 Mylar matrix strip 사이에 소량의 시멘트를 넣고 다양한 시간 간격(20, 40, 60, 80, 100, 120, 140, 160, 180, 200초) 후에 50 N의 부하를 가하고 광중합을 시행하였다. 각 시점에서의 피막도는 $1{\mu}m$ 단위까지 측정 가능한 디지털 피막도 측정기를 이용하여 각 시편 당 세 번씩 측정하여 평균값을 구하였으며, 선형회귀분석을 통하여 시간에 따른 측정값의 변화를 알아 보았다. 또한 Wilcoxon 검정을 사용하여 각 측정값과 제조사에서 제시한 작업 시간을 유의수준 0.05로 비교 분석하였다 ($\alpha$=.05). 결과: 본 연구에 사용된 모든 레진 시멘트에서 혼합 후 부하를 가하기까지 걸린 시간과 피막도는 선형회귀분석 결과 양의 상관관계를 갖는 일차함수적 패턴을 보였다. ISO기준에 따라 피막도가 $50{\mu}m$가 되는 시점까지의 시간은 각 레진 시멘트의 제조사가 제시한 작업 시간과 차이가 있었으나 통계적인 유의성은 없었다. 결론: 레진 시멘트의 피막도는 작업 시간의 증가에 따라 증가한다. 임상에서의 레진 시멘트의 작업 시간은 제조사에서 제시한 작업 시간과 차이가 있을 수 있다.