• 제목/요약/키워드: dental resin composite

검색결과 521건 처리시간 0.024초

Hydrolytic stability of novel silane coupling agents with phenyl group

  • NiHeil, T.;Kuratal, S.;Ohashi, K.;Omotol, N.;Kondo, Y.;Memoto, K.U;Yoshino, N.;Teranaka, T.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.605-605
    • /
    • 2003
  • Novel silane coupling agents containing hydrophobic phenyl group 3-(3-methoxy-4-methacryloyloxyphenyl) propyl-trimethoxysilane(p-MPS), -triisocyanatesilane (p-MBI), -trichlorosilane (p-MBC) were synthesized. The bonding durability of these silanes against water immersion and thermal stress was investigated. 3-methacryloyloxypropyltrimethoxysilane (3-MPG) was used as a control. The glass modified with those silanes at a concentration of 2wt% were kept for 3 minutes at $120^{\circ}C$, and then were bonded to the heaped metal with self-cured resin composite.(omitted)

  • PDF

고강도 할로겐광으로 중합한 복합레진 수복재의 경도 (HARDNESS OF COMPOSITE RESIN CURED BY HIGH INTENSITY HALOGEN LIGHT)

  • 박종석;이광희;김대업;김성형;안호영
    • 대한소아치과학회지
    • /
    • 제28권3호
    • /
    • pp.471-479
    • /
    • 2001
  • 복합레진의 광중합시간 단축과 관련하여 최근에 개발된 고강도 할로겐광 중합기를 기존의 중강도 할로겐광 중합기와 비교 평가하기 위하여, 세 종류의 광중합용 복합레진을 두께가 2, 3, 4, 5mm인 스테인레스 스틸 몰드에 충전하고, 레진 상면을 중강도 할로겐광은 (1) $400mW/cm^2$으로 40초간 고강도 할로겐광은 (2) 10초동안 $100mW/cm^2$부터 $1000mW/cm^2$까지 출력량이 증가하면서 중합하고 다음 10초동안 $1000mW/cm^2$로 중합하는 ramp 모드로 20초간, (3) $1000mW/cm^2$의 boost 모드로 10초간, (4) $850mW/cm^2$의 표준 모드로 20초간 조사하고, 상면과 하면의 표면경도를 미세경도측정기로 측정한 후 실험군간의 차이를 분석하였다. 레진 상면의 경도는 중합광의 강도와 중합시간 및 레진 두께에 따른 차이가 없었다(유의수준 0.05, 이하 동일). 레진 하면의 경도는, 두께 2mm의 중강도군(1)을 제외하고, 상면의 경도보다 낮았다. 레진 하면의 경도는 두께 2mm에서 중강도군(1)이 ramp군(2) 및 boost군(3)보다 높았고 중강도군(1)과 표준군(4) 간 및 ramp군(2)과 boost 군(3) 간에 차이가 없었으며, 두께 3mm에서 중강도군(1)이 가장 높았고 표준군(4)이 boost군(3)보다 높았다. 따라서, 복합레진의 중합 깊이 측면에서 볼 때, $1000mW/cm^2$의 고강도 할로겐광을 10초간 조사한 것은 $400mW/cm^2$의 중강도 할로겐 광을 40초간 조사한 것에 미치지 못하였으며, 레진 두께 2mm이내인 경우에는 $850mW/cm^2$의 고강도 할로겐광을 20초간 조사함으로써 $400mW/cm^2$의 중강도 할로겐광을 40초간 조사한 것과 대등한 중합을 일으킬 수 있었다.

  • PDF

산도변화와 침지시간이 광중합 복합레진의 잔류단량체 유출에 미치는 영향 (EFFECT OF PH AND STORAGE TIME ON THE ELUTION OF RESIDUAL MONOMERS FROM POLYMERIZED COMPOSITE RESINS)

  • 전철민;유현미;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.249-266
    • /
    • 2004
  • The purpose of this study was to determine whether pH and time has any influence on the degradation behavior of composite restoration by analyzing the leached monomers of dental composites qualitatively and quantitatively after storage in acetate buffer solution as a function of time using high performance liquid chromatography (HPLC) / mass spectrometer. Materials and Methods:Three commercial composite restorative resin materials (Z-250, Heliomolar and Aeliteflo) with different matrix structure and filler composition were studied. Thirty specimens (7mm $diameter{\times}2mm$ thick) of each material were prepared. The cured materials were stored in acetate buffer solution at different pH (4, 7) for 1, 7 and 45days. As a reference, samples of unpolymerized composite materials of each product were treated with methanol (10mg/ml). Identification of the various compounds was achieved by comparison of their mass spectra with those of reference compound, with literature data. and by their fragmentation patterns. Data were analysed statistically using ANOVA and Duncan's test. Results:1. Amounts of leached TEGDMA in Aeliteflo were significantly larger than those of UDMA in Z-250 and Heliomolar at experimental conditions of different storage time and pH variation (p<0.001). 2. As to comparison of the amounts of leached monomers per sorage time, amounts of leached TEGDMA in Aeliteflo and UDMA in Z-250 and Heliomolar were increased in the pH 4 solution more significantly than in the pH 7 solution after 1day, 7days and 45days, respectively (p<0.001). 3. In total amounts of all the leached monomers with storage times, the overall amounts of pH 4 extracts were larger than those of pH 7 extracts for all resin groups, but there was no significant difference (p>0.05).

복합레진의 수리 시 표면처리가 결합강도에 미치는 영향 (EFFECT OF SURFACE TREATMENTS ON THE REPAIR BOND STRENGTH OF COMPOSITES)

  • 최정인;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제35권4호
    • /
    • pp.692-699
    • /
    • 2008
  • 본 연구의 목적은 표면처리가 기존의 레진과 새로운 레진 사이의 전단결합강도에 미치는 영향을 평가하는 것이다. 준비된 레진 시편을 6군으로 임의로 배분하여 각각의 표면처리를 한 후 수리용 레진을 축조하였다. 일주일간 보관 후 전단결합강도 를 측정하였고 일원분산 분석법으로 통계처리하여 다음과 같은 결과를 얻었다. 1. 3군과 4군(air abrasion)은 1군(산부식)에 비해 전단결합강도가 유의하게 높게 나타났다(p<0.05). 5군과 6군(diamond bur)은 1군(산부식)에 비해 높은 전단결합강도를 나타냈으나 통계적으로 유의하지 않았다(p>0.05). 2. 2군(자가부식 접착제)은 1군(산부식)에 비해 전단결합강도가 낮게 나타났으나 유의한 차이는 없었다(p>0.05). 3. 3군(air abrasion)과 4군(air abrasion+산부식)에서 전단결합강도의 차이는 유의하지 않았다(p>0.05). 4. 5군(diamond bur)과 6군(diamond bur+산부식)에서 전단결합강도의 차이는 유의하지 않았다(p>0.05). 결론적으로, 복합레진의 수리 시 air abrasion으로 표면처리를 했을 때의 결합강도가 가장 높았고, 산부식 방법과 처리여 부는 수리강도에 유의한 영향을 미치지 않았다.

  • PDF

The effect of individualization of fiberglass posts using bulk-fill resin-based composites on cementation: an in vitro study

  • Lins, Rodrigo Barros Esteves;Cordeiro, Jairo Matozinho;Rangel, Carolina Perez;Antunes, Thiago Bessa Marconato;Martins, Luis Roberto Marcondes
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.37.1-37.10
    • /
    • 2019
  • Objectives: This study evaluated the bond strength of various fiberglass post cementation techniques using different resin-based composites. Materials and Methods: The roots from a total of 100 bovine incisors were randomly assigned to 5 treatment groups: G1, post + Scotchbond Multi-Purpose (SBMP) + RelyX ARC luting agent; G2, relined post (Filtek Z250) + SBMP + RelyX ARC; G3, individualized post (Filtek Z250) + SBMP; G4, individualized post (Filtek Bulk-Fill) + SBMP; G5, individualized post (Filtek Bulk-Fill Flow) + SBMP. The samples were subjected to the push-out (n = 10) and pull-out (n = 10) bond strength tests. Data from the push-out bond strength test were analyzed using 2-way analysis of variance (ANOVA) with the Bonferroni post hoc test, and data from the pull-out bond strength test were analyzed using 1-way ANOVA. Results: The data for push-out bond strength presented higher values for G2 and G5, mainly in the cervical and middle thirds, and the data from the apical third showed a lower mean push-out bond strength in all groups. No significant difference was noted for pull-out bond strength among all groups. The most frequent failure modes observed were adhesive failure between dentine and resin and mixed failure. Conclusions: Fiberglass post cementation using restorative and flowable bulk-fill composites with the individualization technique may be a promising alternative to existing methods of post cementation.

위상잠금 열화상기법을 이용한 치과용 복합레진 수복재의 내부 홀 결함에 대한 비파괴평가 (NDE of the Internal Hole Defect of Dental Composite Restoration Using Infrared Lock-In Thermography)

  • 구자국;최낙삼
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.40-45
    • /
    • 2013
  • 위상잠금 적외선열화상기법을 이용하여 치과용 복합레진 수복재의 내부 홀 결함 크기에 따른 검출 가능성을 연구하였다 위상잠금 주파수 조건을 다르게 하며 진폭과 위상영상을 분석하였다. 진폭 이미지 분석을 통해 직경 2 mm 이상의 결함 검출이 가능함을 알았으며 0.05 Hz 부근에서 결함부의 구별이 뚜렷하고 선명한 이미지를 획득할 수 있었다. 진폭 대비차는 결함부의 직경 크기에 비례하였다. 위상 이미지 분석 결과 0.3-0.5 Hz 부근에서 최적의 대조 영상을 보였으며 0.006 Hz 에서는 반대 명암의 뚜렷한 이미지를 얻을 수 있었다. 진폭 분석보다 위상 분석에서 결함부 크기가 작은 시편의 검출 가능성이 더 높았다.

접착레진 적용 유무에 따른 TEGDMA의 방출속도 및 방출량 비교 (A COMPARISON OF RELEASE RATE AND CUMULATIVE RELEASE OF TEGDMA WITH OR WITHOUT THE APPLICATION OF BONDING RESIN)

  • 신희정;전성민
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.701-709
    • /
    • 1998
  • Many dental composites are Bis-GMA based resin which diluted with the more fluid monomer triethylenglycol dimethacrylate(TEGDMA). TEGDMA is often present in exess so that some quantity remains unreacted following photo-initiated polymerization. TEGDMA is a component of some resin composites which contributes to their cytotoxicity. The presence of dentin between resin composite and pulp space reduce the cytotoxicity in vitro. The root system from extrcted human third molar was removed and then a circular occlusal cavity 4mm in diameter was prepared, leaving a remaining dentinal thickness to the roof of the pulpal chamber within the range 1.0-1.5mm. Dentine was treated with 37% phosphoric acid prior to Z 100 placement without using bonding resin(group 1). In group 2, SMP(Scotchbond Multi Purpose) primer, bonding resin prior to Z 100 placement were applied sequently. In group 3, moulds with internal dimensions 4mm diameter by 2mm depth were used to contain the composite alone with an equvalent mass on tooth model, and then they were immersed directly into water. The purpose of this study is to evaluate the release rate and quantity of TEGDMA with or without the application of bonding resin. Both release rate and total cumulative amount of TEGDMA for the three groups were determined using reversed-phase HPLC at times up to 10 days. The results were as follows: 1. All experimental groups showed the highest rate of release was in the first sample period(0-4.32 min) and the rate of release declined exponentially thereafter. 2. The maximum release rate and total cumulative account of TEGDMA in the tooth model of group 1 and group 2 with the use of SMP bonding resin were reduced however ther were no significant differences between these groups(P>0.05). 3. In the first sample period(0-4.32 min), the rate of release of TEGDMA from composite resin in group 3 immersed directly into water was significantly higher than that in group 1 and group 2 of tooth model(P<0.05). Conclusively, TEGDMA diffusion from Z 100 resin was not effectively prevented by the presence of dentin in spite of using the SMP bonding resin.

  • PDF

Halogen lamp 광조사기와 Plasma xenon arc lamp 광조사기에 의한 광중합 복합레진의 중합률 비교 (COMPARISON OF THE DECREE OF CONVERSION IN LIGHT-CURED COMPOSITE RESIN CURED BY HALOGEN AND PLASMA XENON ARC LAMP CURING UNIT)

  • 이영준;정병초;최남기;양규호
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.328-336
    • /
    • 2002
  • 본 연구의 목적은 일반 halogen lamp 광조사기와 비교하여 plasma xenon arc lamp 광조사기의 광중합 능력을 평가하기 위한 것이다. 7mm의 내경과 1mm, 2mm, 3mm 두께를 갖는 레진 시편을 aluminum 주형상에서 제작하여 plasma xenon arc lamp 광조사기는 2초, 3초, 6초, halogen lamp 광조사기는 20초, 40초, 60초 동안 광조사한 후 Raman spectroscopy를 이용하여 레진 시편 표면과 후면의 중합률을 측정하였다. 표면 중합률은 광조사 시간이 증가함에 따라 halogen lamp 광조사기와 plasma xenon arc lamp 광조사기 모두에서 유의성있게 증가하였으며 전반적인 중합률은 halogen lamp 광조사기에서 더 높았으나 plasma xenon arc lamp 광조사기와 유의한 차이는 없었다. 광조사 시간이 증가함에 따라 halogen lamp 광조사기의 경우 후면 중합률은 모든 두께에서 점차 증가하였으나 1.2mm 두께에서는 유의한 차이가 없었으며 plasma xenon arc lamp 광조사기로 중합한 경우에는 모든 두께에서 조사시간이 증가할수록 중합률은 유의성있게 증가하였다. 이상의 결과로 plasma xenon arc lamp 광조사기의 강한 광도가 광조사 시간의 감소를 완전히 보상하지는 못하는 것으로 판단되므로 plasma xenon arc lamp 광조사기로 광중합 복합레진을 중합할 경우 2mm이내의 적층 충전이 요구되며 또한 제조회사가 제시한 조사 시간보다 추가적인 광조사가 필요할 것으로 판단된다.

  • PDF

부분 무치증을 동반한 지적장애 환자의 전치부 심미수복 : 증례보고 (ANTERIOR ESTHETIC RESIN RESTORATION OF INTELLECTUALLY DISABLED CHILD WITH OLIGODONTIA : A CASE REPORT)

  • 배영은;김지연;정태성
    • 대한장애인치과학회지
    • /
    • 제12권2호
    • /
    • pp.66-71
    • /
    • 2016
  • Intellectual disability is accompanied by a high incidence of congenitally absent teeth and supernumerary teeth, and is observed more frequently than are disorders of location and order during delayed eruption, when accompanied by other symptoms. Furthermore, it is associated with a higher occurrence of dental anomalies such as conical teeth, microdontia, and amelogenesis imperfecta. As it is difficult to obtain adequate cooperation from patients with intellectual disabilities, physical restraint and conscious sedation using medication and general anesthesia can be considered. Reshaping of conical teeth with resin composite may be helpful to rehabilitate patients with oligodontia and a conical tooth shape. Diagnostic wax-up and a silicone matrix formed the basis for the successful reconstruction of the anterior teeth. This case describes the treatment of a patient with intellectual disability who had oligodontia and conical-shaped incisors. Under general anesthesia, the patient was treated using direct composite resin restoration.

복합레진의 광중합 전·후와 shade guide의 색차 비교 (COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES)

  • 전이주;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF