• Title/Summary/Keyword: dental resin composite

Search Result 521, Processing Time 0.027 seconds

Microfocus X-ray CT Analysis of Shrinking Direction in Resin Composite.

  • Inai, N.;Katahira, N.;Hashimoto, K.;Tagami, J.;Hirakimoto, A.;Marshall, S.J.;Marshall. G.W.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.559.1-559
    • /
    • 2001
  • The aim of the study was to determine the direction and the rate of polymerization shrinkage of light-cured resin composite. Materials and Methods: A microfocus x-ray CT(computed tomography) instrument (SMX-255CT, Shimadzu Co., Kyoto, Japan) was used to analyze and characterize the pre-and post-gel phases. A microfocus x-ray tube was used to enable a focus dimension of 4 microns.(omitted)

  • PDF

Analysis of Composite Resin Treatment Pattern Changes After the Insurance Coverage (급여화 이후 복합 레진 수복 치료 패턴 변화 분석)

  • Jo, Sangmi;Lee, Koeun;Nam, Okhyung;Lee, Hyo-seol;Choi, Sungchul;Kim, Kwangchul;Kim, Misun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.151-159
    • /
    • 2021
  • Since January 2019, insurance coverage for caries treatment of permanent teeth using composite resin in children aged 12 and under has started in South Korea. The purpose of this study was to compare the pattern of permanent molar composite resin restoration aged 12 and under before and after the insurance coverage from January 2009 to March 2020 in the Department of Pediatric Dentistry at Kyung Hee University Dental Hospital at Gangdong. Since the insurance coverage was started in 2019, the frequency of permanent molar composite resin restoration aged 12 and under has increased more than twice. There was a significant change in frequency of resin restoration by shape of cavity comparing before and after the insurance coverage, whereas there was no significant difference in changes by patient age, gender and position of tooth. As accessibility to the permanent tooth composite resin restoration is increased by the insurance coverage, which shows a fair survival rate, it is expected that it could be able to secure oral health in the early permanent dentition aged 12 and under.

A Study on the fracture strength of 4 Kinds of Direct Composite Resins (4종의 direct composite resin의 파절강도 비교)

  • Kim, Nam-Joong
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.87-92
    • /
    • 2019
  • Purpose: The Purpose of this study is to compare the fracture strength of 4 kinds of direct composite resins. Methods: his study performed experiments on the fracture strength of direct composite resins after polymerizing 4 kinds of direct composite resins on the MOD cavity standard specimens. Results: The fracture strength of Aelite(Bisco) was the highest at 176.26N(p<0.05). According to post-hoc study with Turkey honest significant difference by multiple comparison on fracture strength test results, there were statistically significant differences between all kinds of direct composite resin. But the statistical difference between Z350(3M) and Spectrum(DP) was not significant. Conclusion: Aelite(Bisco) scored the highest concerning the fracture strength.

Evaluation of surface gloss of composite resins (복합레진의 표면 광택에 대한 평가)

  • Ji-Eun Byun
    • Journal of Korean Academy of Dental Administration
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2023
  • Composite resins, commonly used in clinical practice, have been developed to improve aesthetics to obtain smooth surfaces. Although the restored composite resin has a smooth surface, it gradually becomes rough over time. Therefore, this study measured glossiness to evaluate the surface of various composite resins and attempted to evaluate the maintenance of glossiness of composite resins by observing surfaces that change to roughness. Specimens were produced using resin used in clinical practice: Gradia direct anterior (GA), Tetric N-Ceram (TN), Ceram.X Sphere TEC one (CX), Filtek Z350XT (FT), Estelite sigma quick (ES). After creating a smooth surface with slide glass, five locations were randomly selected to measure surface gloss, and the average was the representative value of the specimen. Roughness was applied to the specimen under water pouring at the same speed and pressure using SiC paper #2400, 1200, and 400. The gloss unit of different SiC papers was measured. To evaluate the gloss unit and gloss retention between composite resins, one-way analysis of variance and Tukey multiple comparisons test were used. As a result of the study, there was a difference in gloss unit of specimens produced under the same conditions. Although the degree differed depending on the composite resin, there was also a difference in gloss retention. Based on the findings, composite resins show differences in gloss due to their different characteristics. Ceram.X Sphere TEC one (CX) showing the lowest gloss retention and Estelite sigma quick (ES) showing the highest.

The effect of thermocycling on the degree of conversion and mechanical properties of a microhybrid dental resin composite

  • Ghavami-Lahiji, Mehrsima;Firouzmanesh, Melika;Bagheri, Hossein;Jafarzadeh Kashi, Tahereh S.;Razazpour, Fateme;Behroozibakhsh, Marjan
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.26.1-26.12
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the degree of conversion (DC) and mechanical properties of a microhybrid Filtek Z250 (3M ESPE) resin composite after aging. Method: The specimens were fabricated using circular molds to investigate Vickers microhardness (Vickers hardness number [VHN]) and DC, and were prepared according to ISO 4049 for flexural strength testing. The initial DC (%) of discs was recorded using attenuated total reflectance-Fourier transforming infrared spectroscopy. The initial VHN of the specimens was measured using a microhardness tester under a load of 300 g for 15 seconds and the flexural strength test was carried out with a universal testing machine (crosshead speed, 0.5 mm/min). The specimens were then subjected to thermocycling in $5^{\circ}C$ and $55^{\circ}C$ water baths. Properties were assessed after 1,000-10,000 cycles of thermocycling. The surfaces were evaluated using scanning electron microscopy (SEM). Data were analyzed using 1-way analysis of variance followed by the Tukey honest significant difference post hoc test. Results: Statistical analysis showed that DC tended to increase up to 4,000 cycles, with no significant changes. VHN and flexural strength values significantly decreased upon thermal cycling when compared to baseline (p < 0.05). However, there was no significant difference between initial and post-thermocycling VHN results at 1,000 cycles. SEM images after aging showed deteriorative changes in the resin composite surfaces. Conclusions: The Z250 microhybrid resin composite showed reduced surface microhardness and flexural strength and increased DC after thermocycling.

Flexural strength of indirect composite resin with different polymerization conditions (중합 조건에 따른 간접복합레진의 굴곡강도)

  • Geum, Young-Hee;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.333-341
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the flexural strength of indirect composite resins with different polymerization conditions. Methods: Ten specimens ($2mm{\times}2mm{\times}25mm$) of each composite resins (Tescera (T), Gradia (S) and Sinfony (S)) were fabricated by two polymerization methods : manufacturers's and light heat pressure. Composite resins polymerized by manufacturers's method and light heat pressure served as control (TS, GS and SS) and experimental groups (TE, GE and SE), respectively. The composite resins were tested for flexural strength and the surface of composite resins were observed with scanning electron microscope (SEM) under X1,000 magnification. Results: The flexural strength values of cured composite resin decreased in the following order: TE (195.4MPa), TS (179.8MPa), GE (169.9MPa), SE (137.7MPa), SS (111.1MPa) and GS (100.9MPa) groups. Conclusion: The flexural strength values between the control and the experimental groups were not significantly different although experimental groups showed higher flexural strength values than control groups.

Effect of Liquefied Digestive Medicine on the Surface of Composite Resin

  • Kim, Min-Young;Lim, Hee-Jung;Kim, Ha-Eun;Kim, Hyun-Jeong;Yu, Hye-Kang;Choi, Soo-Jin;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.22 no.1
    • /
    • pp.20-29
    • /
    • 2022
  • Background: The purpose of this study is to investigate the effect of liquefied digestive medicines on the composite resin surface. Methods: Three types of liquefied digestive medicines (Gashwalmyeongsu, Wicheongsu, and Saengrokcheon) were selected as experimental groups, Samdasoo and Chamisul as negative controls, and Trevi as positive controls were selected to measure pH and titratable acidity. The samples filled with resin at acrylic were made total 300, 50 per group. To evaluate the erosion risk of the composite resin, the specimens were immersed in a liquefied medicine for 1, 3, 5, 15, and 30 minutes, and then the surface microhardness was measured using the Vickers Hardness Number, and the surface change was observed with scanning electron microscope (SEM). Results: The average pH of the three liquefied medicine was 3.75±0.30, the Saengrokcheon was the lowest at 3.45±0.01, and the Trevi was 4.66 and Samdasoo and Chamisul were 7.40 and 8.58, respectively. The amount of NaOH reaching pH 5.5 and 7.0 was the lowest in the order of Trevi, Gashwalmyeongsu, Wicheongsu, and Saengrokcheon. The largest surface hardness reduction value was shown in Gashwalmyeongsu (-11.85±3.73), followed by Saengrokcheon (-9.79±3.11) and Wicheongsu (-8.28±2.83), and Samdasoo (-0.84±1.56) and Chamisul (-6.24±0.42) had relatively low surface hardness reduction values. However, Trevi (-16.67±5.41), a positive control group containing carbonic acid, showed a higher decrease in surface hardness than the experimental group. As a result of observation with SEM, experimental group and positive control group, showed rough surfaces and irregular cracks, and negative control groups showed smooth patterns similar to before immersion. Conclusion: The liquefied digestive medicine with low pH could weaken the composite resin surface, and the carbonic acid component could more effect on the physical properties of the composite resin than pH.

Effect of immersion into solutions at various pH on the color stability of composite resins with different shades

  • Moon, Ji-Deok;Seon, Eun-Mi;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.4
    • /
    • pp.270-275
    • /
    • 2015
  • Objectives: This study examined the color changes of a resin composite with different shades upon exposure to water with different pH. Materials and Methods: Nanohybrid resin composites (Filtek Z350XT, 3M ESPE) with four different shades (A2, A3, B1, and B2) were immersed in water with three different pH (pH 3, 6, and 9) for 14 day. The CIE $L^*a^*b^*$ color coordinates of the specimens were evaluated before and after immersion in the solutions. The color difference (${\Delta}E^*$) and the translucency parameter (TP) were calculated using the color coordinates. Results: ${\Delta}E^*$ ranged from 0.33 to 1.58, and the values were affected significantly by the pH. The specimens immersed in a pH 6 solution showed the highest ${\Delta}E^*$ values (0.87 - 1.58). The specimens with a B1 shade showed the lowest ${\Delta}E^*$ change compared to the other shades. TP ranged from 7.01 to 9.46 depending on the pH and resin shade. The TP difference between before and after immersion in the pH solutions was less than 1.0. Conclusions: The resulting change of color of the tested specimens did not appear to be clinically problematic because the color difference was < 1.6 in the acidic, neutral, and alkaline solutions regardless of the resin shade, i.e., the color change was imperceptible.

Study on shear bond strength of various composite resins to artificial denture teeth (수복용 레진과 인공치아간의 결합강도 연구)

  • Park, Kyung-Mo
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.171-177
    • /
    • 2014
  • Purpose: The dental medicine has been preparing the custom-made service to meet the requirements of the aged society, while the average span of human life is growing more and more, and the full denture is a representative of them. It is causing great concern in these atmosphere of society, and demands for it are expected to increase. The full denture is a uniform combination of denture base and artificial teeth using polymerization, and is most influenced by change of physical properties of denture base and bonding strength with artificial teeth. Methods: In this study, the samples were made of composite resin combined with occlusion surface of artificial teeth undergone mechanically surface treatment to evaluate the bonding strength of composite resin for repairing artificial teeth. The resin teeth used in this study are 3 types artificial teeth. And 3 types of composite resins are used that are various polymerization resin. The shear strength of composite resins made in various polymerization ways to resin teeth was measured to evaluate bonding strength of artificial teeth to each composite resins. Results: Surface hardness's results on Trubyte Biotone(74.58Hv), Biotone IPN(70.06Hv), Endura Posterio (64.48Hv). Results of bonding strength of artificial teeth to composite resins on ES samples(8.73Mpa), IF(4.37Mpa) and IZ(3.84Mpa). Conclusion: 1. The Trubyte Biotone(74.58Hv) was first, followed by Biotone IPN(70.06Hv), and Endura Posterio(64.48Hv) in surface hardness's results of worn sides using hardness test. 2. The ES samples(8.73Mpa) showed significant differences with IF(4.37Mpa) and IZ(3.84Mpa) (p<0.05), but not other samples(p>0.05) in results of bonding strength of artificial teeth to composite resins.

Photopolymerization efficiency of dental resin composites with new mixed photosensitizers (새로운 혼합형 광증감제를 사용한 치과용 복합수지의 중합효율에 관한 연구)

  • Sun, Gum-Ju;Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.49-58
    • /
    • 2004
  • Two diketones, 1-phenyl-1,2-propanedione(PD) and 2,3-butanedione (BD) were investigated as new visible light photosensitizers for a dental resin composite of bis-GMA in order to improve photopolymerization effect. And the photopolymerization efficiency of mixed photosensitizers, PD-CQ and DA-CQ, was studied. Photopolymerization effect of photosensitizers were compared with that of camphorquinone(CQ), the most widely used photosensitizer. The photopolymerization efficiency of bis-GMA containing the photosensitizer increased with irradiation time. The increase was in the order: BD < CQ < PD. The photopolymerization efficiency of this mixture was not so efficient as CQ or PD.

  • PDF