• Title/Summary/Keyword: dental application

Search Result 1,158, Processing Time 0.027 seconds

The effect of a pulsed-Nd:YAG laser irradiation on microstructure of human gingiva (파동형 Nd:YAG 레이저조사가 인체 치은조직의 미세구조에 미치는 영향)

  • Han, Kyung-Yoon;Shin, Kwang-Yong;Kim, Chun-Seok;Kim, Hyung-Soo;Yum, Chang-Yup;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.317-328
    • /
    • 1997
  • Since laser therapy has been applied to dentistry, many dental practitioners are very interested in laser therapy on various intraoral soft tissue lesions including gingival hyperplasia and aphthous ulcer. The purpose of the present study was to determine the therapeutic effect and the harmful effect of a pulsed-Nd:YAG laser irradiation on human gingival tissue. In twenty periodontal patients with gingival enlargement, the facial gingival surface of maxillary anterior teeth was randomly irradiated at various power of 1.0W(100mJ, 10Hz), 3.0W(100mJ, 30Hz) and 6.0W(l50mJ, 40Hz) for 60 seconds by contact delivery of a pulsed-Nd:YAG laser(EN.EL.EN060, Italy). Immediately after laser irradiation, the gingival tissues were surgically excised and prepared in size of 1mm3. Subsequently the specimens were processed for prefixation and postfixation, embedded with epon mixture, sectioned in $1{\mu}$ thickness, stained with uranyl acetate and lead citrate, and observed under transmission electron microscope(JEM 100 CXII). Following findings were observed; l. In the gingival specimens irradiated with l.OW power, widening of intercelluar space and minute vesicle formation along the widened intercellular space were noted at the epithelial cells adjacent to irradiated area. 2. In the gingival specimens irradiated with 3.0W power, the disruption of cellular membrane, aggregation of cytoplasm, and loss of intercellular space were observed at the epithelial cells adjacent to irradiated area. 3. In the gingival specimens irradiated with 6.0W power, the disruption of nuclear and cellular membrane was observed at the epithelial cells adjacent to irradiated area. The ultrastructural findings of this study suggest that surgical application of a pulsed-Nd:YAG laser on human gingival tissue may lead somewhat delayed wound healing due to damage of epithelial cells adjacent to irradiated area.

  • PDF

The Effect of IGF-1 on ALP Activity of MC3T3-E1 Cell (MC3T3-E1세포의 ALP activity에 대한 IGF-I의 영향)

  • Lee, Hu-Jung;Lee, Jae-Mok;Choi, Byung-Ju;Yu, Hyun-Mo;Shu, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.4
    • /
    • pp.669-684
    • /
    • 1997
  • Polypeptide growth factors belong to a class of potent biologic mediators which regulate cell differentiation, proliferation, migration and metabolism. IGF-I is polypeptides secreted by skeletal cells and is considered as regulators of bone formation. The purpose of this study is to evaluate the effects of IGF-I on bone nodule formation and alkaline phosphatase activity of MC3T3-E1 cells. MC3T3-E1 cells were seeded at $1{\times}10^4$ cells/well, $1{\times}10^5$ cells/well in alpha-modified Eagle medium containing 10% fetal bovine serum, 10 mM ${\beta}-glycerophosphate$ and $5O{\mu}g/ml$ of ascorbic acid. Before 48 hours of indicated time, medium were changed with serum free medium. After 24 hours, 0.1, 1, 10 ng/ml IGF-I were added to the cells and cultured for 3, 7, 14, 21, 28 days. And histochemical analysis was done and ALP activity was measured and was expressed as nmol/min/mg of protein. The bone nodule formation in MC3T3-E1 cells of IGF-I was seen at 21, 28 days, but there were no difference between control group and experimental groups. The ALP activity decreased when it is compare to control 2 group except for 1 ng/ml, 10 ng/ml IGF-I of 21-day-groups and 1 ng/ml IGF-I of 28-day-groups. Dose response effects of IGF-I of ALP activity in MC3T3-E1 cells were seen the highest ALP activity at 1ng/ml until 21days and the highest ALP activity at 10 ng/ml of 28 daygroups. The peak times were seen at 7-day group, 14-day group on control group and experimental group respectively, and 1 ng/ml group was the highest ALP activity, From the above results, IGF-I was not seen notable effect on bone nodule formation and decreased ALP activity of MC3T3-E1 cells but the use of IGF-I to mediate biological stimulation of MC3T3-E1 cells shows promise for future therapeutic application.

  • PDF

Effect of Calcium Hydroxide on the Microhardness of Root Dentin of Primary Tooth (수산화칼슘 근관충전제의 적용이 유치 치근상아질의 미세경도에 미치는 영향)

  • Jun, Saeromi;Kim, Jong-Bin;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.177-184
    • /
    • 2013
  • Calcium hydroxide mixture medicaments can nearly be considered to be the ideal primary tooth filling material. However, long-term application of calcium hydroxide combinations as an intra canal medicament softens dentin. The aim of this study was to evaluate the effect of calcium hydroxide on the microhardness of root dentin of primary tooth. For the study, 60 extractedprimary incisors were divided into 3 groups (no medicament, calcium hydroxide/iodorform mixture, and calcium hydroxide/distilled water mixture). After the cleansing and shaping of canals, calcium hydroxide medicaments were applied and stored for different periods of time (1, 7, 30, 90 days). The root was horizontally sectioned into 2 mm thick specimens and the microhardness was measured using Vickers microhardness tester. The results were as follows : Root dentin microhardness of primary teeth decreased with long term exposure to calcium hydroxide medicaments according to the experimental period and showed statistically significance (p < 0.05). Root dentin microhardness of primary tooth filled with calcium hydroxide mixed with distilled water showed more decrease than filled with Vitapex and showed statistically significance (p < 0.05). Root dentin microhardness of a control group without exposure to calcium hydroxide decreased according to the experimental period and showed statistically significance (p < 0.05).

RETROSPECTIVE STUDY OF FACE MASK THERAPY (FACE MASK의 치료 효과에 대한 후향적 고찰)

  • Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.547-556
    • /
    • 1996
  • The purpose of this study was to evaluate the skeletal, dental and soft tissue profile changes following the face mask therapy in growing skeletal class III malocclusion patients. The fifteen patients with the good results were selected among the patients who visited the Department of Orthodontics in Seoul National University Hospital. The mean age was 10.63(range 7.25-13.25) years and the mean treatment duration was 9.84(range 2.00-27.00) months. Lateral cephalograms were taken just before and after face mask application. After tracing the cephalograms, thirty five items(twety angular and fifteen linear) were measured. The differences before and after the face mask therapy were compared statistically by the paired t-test(p<0.05). The results were as follows : SNA and Co-A(effective maxillary length) increased significantly after using the face mask(p<0.001), which reflects the orthopedic changes of maxilla. SNB and Co-Gn(effective mandibular length) also showed an increase(p<0.01), which may be a result of the strong growth trends of the samples. FMA, SN-GoGn and Y-axis angle increased significantly(p<0.01), which means the backward and downward rotation of the mandible. This positional change seemed to have compensated an increase of effective mandibular length. There was no statistically significant difference in angulation of upper and lower incisors between pre-treatment and post-treatment(p>0.05). In soft tissue profile, the upper lip was positioned anteriorly(p<0.01) after treatment and approximated to the normal standards.

  • PDF

Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length (다양한 길이의 two-component 미니 임플란트의 응력분산에 대한 3차원적 유한요소분석)

  • Choi, Bohm;Lee, Dong-Ok;Mo, Sung-Seo;Kim, Seong-Hun;Park, Ki-Ho;Chung, Kyu-Rhim;Nelson, Gerald;Han, Seong-Ho
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.423-430
    • /
    • 2011
  • Objective: To evaluate the extent and aspect of stress to the cortical bone after application of a lateral force to a two-component orthodontic mini-implant (OMI, mini-implant) by using three-dimensional finite element analysis (FEA). Methods: The 3D-finite element models consisted of the maxilla, maxillary first molars, second premolars, and OMIs. The screw part of the OMI had a diameter of 1.8 mm and length of 8.5 mm and was placed between the roots of the upper second premolar and the first molar. The cortical bone thickness was set to 1 mm. The head part of the OMI was available in 3 sizes: 1 mm, 2 mm, and 3 mm. After a 2 N lateral force was applied to the center of the head part, the stress distribution and magnitude were analyzed using FEA. Results: When the head part of the OMI was friction fitted (tapped into place) into the inserted screw part, the stress was uniformly distributed over the surface where the head part was inserted. The extent of the minimum principal stress suggested that the length of the head part was proportionate with the amount of stress to the cortical bone; the stress varied between 10.84 and 15.33 MPa. Conclusions: These results suggest that the stress level at the cortical bone around the OMI does not have a detrimental influence on physiologic bone remodeling.

Effect of low intensity pulsed ultrasound (LIPUS) on bone healing around a titanium implant in the tibia of osteoporosis-induced rats (골다공증 유도 백서경골에 티타늄 임플란트 매식 시 저출력 초음파 적용이 골 치유에 미치는 영향)

  • Hwang, Young-Seob;Jeon, Hyun-Jun;Shin, Sang-Hun;Chung, In-Kyo;Kim, Gyoo-Cheon;Kim, Chul-Hoon;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.386-395
    • /
    • 2011
  • Introduction: Osteoporosis is a major health problem in the elderly that involves changes in the properties of bone as well as impaired bone healing around a titanium implant in both humans and animals. This study examined effect of low intensity pulsed ultrasound (LIPUS) on the bone healing process around a titanium implant in osteoporosis-induced rats. Materials and Methods: Sixteen rats were divided into two groups. A control group with osteoporosis induced by removing both ovaries and an experimental group of rats that were applied with LIPUS after osteoporosis had been induced. A screw type titanium implant (diameter, 2.0 mm: length, 3.5 mm, Cowell-Medi, KOREA) was placed into the tibias of 16 rats. The control and experimental group contained 8 rats each. The rats were sacrificed at 1, 2, 4, and 8 weeks after implantation to examine the histopathology and immunochemistry. Results: The histopathology examination revealed earlier new bone formation in the experimental group than the control group. In particular, at 1 week after implantation, more new bone matrix and collagen were observed around the implant of the experimental group compared to the control group. Immunochemistry analysis showed that the level of OPG expression of the experimental group was higher in the early stages than in the control group. After 8 weeks, the levels of OPG expression were similar in both groups. The expression level of receptor activator of nuclear factor kB ligand (RANKL) was stronger in the experimental group than the control group. After 4 weeks, the level of RANKL expression was similar in both groups. Conclusion: These results suggest that the application of LIPUS to implantation can promote bone healing around titanium in osteoporosis animals.

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Changes of the Pharyngeal Space by Various Oral Appliances for Snoring (수종의 코골이장치 장착에 따른 인두공간의 변화)

  • Jo, Chul-Bae;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.247-256
    • /
    • 2009
  • The purpose of this study was to investigate the changes of the pharyngeal space when the following appliances were inserted: the mandibular advancement appliance (MAA), tongue retaining appliance (TRA), and mandibular advancement-tongue retaining appliance (MATRA). Nine male dental students exhibiting Class I occlusion, normal body mass index (BMI), and no signs and symptoms of snoring were selected for this study. The three kinds of snoring appliances (MAA, TRA and MATRA) were fabricated for each subject. The mandibular advancement of the MAA and MATRA was set at a distance of 5 mm, and the TRA and MATRA were made to hold the tongue in front of the maxillary incisors by 10 to 20 mm. Lateral cephalometric radiographs of the following four states - with no appliance, MAA, TRA, and MATRA - were taken to examine any anatomical changes resulting from the application of the appliances. All four radiographs were traced and analyzed for twenty selected variables related to the pharyngeal space, cranio-cervical posture, and position of the soft palate and hyoid bone. According to the results of this study, there were significant increases in both the upper and lower oropharyngeal spaces when the mandible and tongue were protruded simultaneously, although there was a significant increase only in upper oropharyngeal space when the mandible or tongue was advanced separately. In conclusion, it is suggested that the MATRA may result in more positive effect on the control of snoring and OSA compared to a single use of the MAA or TRA, especially for the patients whose upper airway obstruction occurs in the lower oropharynx.

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF