• 제목/요약/키워드: dental Implantation

검색결과 265건 처리시간 0.023초

수종의 재생 술식 시행이 매식체 근원심부의 골재생에 미치는 영향 (The Effects of various Regeneration techniques on Bone Regeneration around Dental Implant)

  • 이명자;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제35권2호
    • /
    • pp.383-399
    • /
    • 2005
  • The successful implantation necessitate tissue regeneration m site of future implant placement, there being severe bone defect. Therapeutic approaches to tissue regeneration in the site have used bone grafts, root surface treatments, barrier membranes, and growth factors, the same way being applied to periodontal tissue regeneration. Great interest in periodontal tissue regeneration has lead to research in bone graft, guided-tissue regeneration, and the administration of growth factors as possible means of regenerating lost periodontal tissue. The blood component separated by centrifuging the blood is the platelet-rich plasma. There are growth factors, PDGF, $TGF{beta}1$, $TGF{beta}2$ and IGF in the platelet-rich plasma. The purpose of this study was to study the histopathological correlation between the use of platelet-rich plasma and the healing of bone defect around implant fixture site. Implant fixtures were inserted and graft materials were placed into the left femur of in the experimental group, while the control group received only implant fixtures. In the first experimental group, platelet-rich plasma and BBP xenograft were placed at the implant fixture site, and the second experimental group had platelet-rich plasma, BBP xenograft, and the e-PTFE membrane placed at the fixture site. The degree of bone regeneration adjacent to the implant fixture was observed and compared histopathologically at 2, 4, and 8 weeks after implant fixture insertion. The results of the experiment were as follows: 1. Bone remodeling in acid etched surface near the implant fixture of all experimental groups was found to be greater than new bone formation. 2. Bone remodeling in acid etched surface distant to the implant fixture of all experimental groups was decreased and new bone formation was not changed. 3. Significant new bone formation in machined surface near the implant fixture of bothl experimental groups was observed in 2 weeks. 4. New bone formation in machined surface distant to the implant fixture of both experimental groups was observed. Bone remodeling was significant in near the implant fixture and not in distant to the implant fixture. The results of the experiment suggested that the change of bone formation around implant. Remodeling in machined surface distant to the implant fixture of both experimental groups, and new bone formation and remodeling near the implant fixture were significant.

Effects of Human Mesenchymal Stem Cell Transplantation Combined with Polymer on Functional Recovery Following Spinal Cord Hemisection in Rats

  • Choi, Ji Soo;Leem, Joong Woo;Lee, Kyung Hee;Kim, Sung-Soo;SuhKim, Haeyoung;Jung, Se Jung;Kim, Un Jeng;Lee, Bae Hwan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제16권6호
    • /
    • pp.405-411
    • /
    • 2012
  • The spontaneous axon regeneration of damaged neurons is limited after spinal cord injury (SCI). Recently, mesenchymal stem cell (MSC) transplantation was proposed as a potential approach for enhancing nerve regeneration that avoids the ethical issues associated with embryonic stem cell transplantation. As SCI is a complex pathological entity, the treatment of SCI requires a multipronged approach. The purpose of the present study was to investigate the functional recovery and therapeutic potential of human MSCs (hMSCs) and polymer in a spinal cord hemisection injury model. Rats were subjected to hemisection injuries and then divided into three groups. Two groups of rats underwent partial thoracic hemisection injury followed by implantation of either polymer only or polymer with hMSCs. Another hemisection-only group was used as a control. Behavioral, electrophysiological and immunohistochemical studies were performed on all rats. The functional recovery was significantly improved in the polymer with hMSC-transplanted group as compared with control at five weeks after transplantation. The results of electrophysiologic study demonstrated that the latency of somatosensory-evoked potentials (SSEPs) in the polymer with hMSC-transplanted group was significantly shorter than in the hemisection-only control group. In the results of immunohistochemical study, ${\beta}$-gal-positive cells were observed in the injured and adjacent sites after hMSC transplantation. Surviving hMSCs differentiated into various cell types such as neurons, astrocytes and oligodendrocytes. These data suggest that hMSC transplantation with polymer may play an important role in functional recovery and axonal regeneration after SCI, and may be a potential therapeutic strategy for SCI.

The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina: a retrospective clinical study

  • Kim, Min-Joong;Yun, Pil-Young;Chang, Na-Hee;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.10.1-10.9
    • /
    • 2020
  • Background: The aim of this study was to evaluate the long-term clinical stability of implants with acid-etched surfaces sandblasted with alumina using retrospective analyses of the survival rate, success rate, primary and secondary stability, complications, and marginal bone loss of the implants. Methods: Patients who had implants placed (TS III SA, SS II SA, SS III SA, and U III SA) with SA surfaces from Osstem (Osstem Implant Co., Busan, Korea) at the Seoul National University Bundang Hospital, from January 2008 to December 2010 were selected for the study. Patients' medical records and radiographs (panorama, periapical view) were retrospectively analyzed to investigate sex, age, location of implantation, diameter, and length of the implants, initial and secondary stability, presence of bone grafting, types of bone grafting and membranes, early and delayed complications, marginal bone loss, and implant survival rate. Results: Ninety-six implants were placed in 45 patients. Five implants were removed during the follow-up period for a total survival rate of 94.8%. There were 14 cases of complications, including 6 cases of early complications and 8 cases of delayed complications. All five implants that failed to survive were included in the early complications. The survival of implants was significantly associated with the occurrence of complications and the absorption of bone greater than 1 mm within 1 year after prosthetic completion. In addition, the absorption of bone greater than 1 mm within 1 year after prosthetic completion was significantly associated with the occurrence of complications, primary stability, and implant placement method. Five cases that failed to survive were all included in the early complications criteria such as infection, failure of initial osseointegration, and early exposure of the fixture. Conclusions: Of the 96 cases, 5 implants failed resulting in a 94.8% survival rate. The failed implants were all cases of early complications such as infection, failure of initial osseointegration, and early exposure of the fixtures. Periimplantitis was mostly addressed through conservative and/or surgical treatment and resulted in very low prosthetic complications. Therefore, if preventive measures are taken to minimize initial complications, the results can be very stable.

미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석 (Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography)

  • 배인호;고정태;임경섭;박대성;김종민;정명호
    • 한국방사선학회논문지
    • /
    • 제6권2호
    • /
    • pp.93-98
    • /
    • 2012
  • 미세단층촬영기법은 전임상 동물실험 분석시 고해상도의 혈관 영상화를 위한 중요한 수단이다. 이는 조직 분석과 같이 샘플 훼손이 예상되는 분석 작업 이전에 비파괴적인 방법으로 2차원 또는 3차원 이미지 재구성할 수 있는 장점이 있다. 본 연구에서는 생체 이식용 의료기기인 스텐트를 동물모델에서 전임상 분석을 하는데 있어 미세단층촬영기법의 활용방법을 제시하고 금속 스텐트(BMS)와 약물(paclitaxel)이 코팅된 스텐트(DES)의 스텐트 내 재협착정도(ISR)를 토끼 모델을 이용하여 평가하고자 하였다. BMS와 DES를 무작위적으로 토끼의 장골동맥에 식립하고 4주 후에 스텐트가 식립된 주위 혈관을 적출한 다음 스텐트 내강에 조영제를 투여하였다. 미세단층촬영기를 이용하여 50kV/200${\mu}A$의 X-ray 조사량으로 샘플을 스캔하였다. 정량적 분석을 위해 CTAN 소프트웨어를 이용하여 관심영역을 지정하여 정량적 분석을 수행하였다. 피폭 대상에 따라 각기 다른 CT값(Hounsfied Unit)을 획득할 수 있었으며(스텐트 영역; 약 1.2, 조영제 영역; 0.12~0.17, X-ray 비흡수 영역; 0~0.06), 이를 이용하여 2차원, 3차원적 영상을 획득하고 스텐트내 재협착 면적을 산출하였다. 조직병리학적 분석의 염증지수에 해당할 수 있는 확장된 스텐트의 크기를 측정하였을 때 BMS와 DES간의 유의한 차이가 나타나지 않았다. 또한 BMS 그룹의 ISR($1.52{\pm}0.48mm2$)이 DES의 ISR($0.94{\pm}0.42mm2$)에 비해 약 1.6배 높은 것으로 확인되었다. 이는 DES에 코팅된 paclitaxel이 세포 증식을 억제하여 스텐트 내강으로 증식하는 것을 저해하였기 때문으로 판단된다. 2차원적 분석 결과 BMS의 재협착 분포는 스텐트 중간 영역에서 전면부와 후면부에 비해 비교적 높은 것으로 확인되었다. 이러한 연구 결과로 볼 때 미세단층촬영기법은 비파괴적인 방법으로 분석이 가능하며 정량적 분석을 위한 기존의 복잡한 조직병리학적 분석법의 보조적인 수단으로 활용될 수 있을 것이다.

Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향 (The influence of Collar design on peri-implant marginal bone tissue)

  • 김지환;정문규;문홍석;한동후
    • 대한치과보철학회지
    • /
    • 제46권1호
    • /
    • pp.53-64
    • /
    • 2008
  • 임플랜트 주위 변연골의 흡수는 임플랜트의 기능적 및 심미적 성공에 큰 장애가 되는 요인이다. Adell은 임플랜트에 지대주 연결 후 첫 1년간 평균적으로 1.5mm의 변연골 소실을 보이고, 이 후에는 매년 0.1mm이하의 변연골 흡수가 있었다고 하였다(Adell et al.,1981). 이러한 변연골 흡수를 막기위한 많은 노력들이 행해져 왔다. 특히 임플랜트 collar의 특징에 따라서 변연골의 흡수가 달라질 수 있다. 본 연구의 목적은 임플랜트 collar에서의 laser microtexturing(microgroove)이 변연골 흡수에 미치는 영향에 대해 알아보고자 하는 것이다. 4종류의 임플랜트 총 101개를 식립한 환자 53명에서 임플랜트 식립시부터 보철물 장착한 후 평균 6개월 후 정기 검사 시까지의 임플랜트 주위 변연골의 흡수를 측정하여 비교하였다. 생물학적 폭경을 충분히 확보한 임플랜트(ITI standard)와 생물학적 폭경이 부족한 임플랜트 (ITI esthetic plus, Silhouette IC Laser-$Lok^{TM}$, Silhouette IC)에서 변연골 흡수의 차이를 비교하였고, 임플랜트 주위 변연골의 흡수에 대한 laser를 이용한 미세나사산의(Silhouette IC Laser-$Lok^{TM}$) 영향을 알아보았다. 다음의 결과를 얻었다. 1. ITI standard와 Silhouette IC Laser-$Lok^{TM}$ 이 ITI esthetic plus 와 Silhouette IC 보다 임플랜트 주위 변연골의 흡수가 적었고 (p<0.05), ITI standard 와 Silhouette IC Laser-$Lok^{TM}$ 사이에는 변연골의 흡수가 유의차가 없었고(P>0.05), ITI esthetic plus와 Silhouette IC 사이에도 변연골의 흡수가 유의차가 없었다(P>0.05). 2. 사용된 임플랜트 전체에 대한 상하악의 비교에서는 상하악 사이에서 임플랜트 주위 변연골의 흡수는 통계학적으로 유의한 차이가 없었다(p>0.05). 3. 흡수각도에 대한 비교에서도 4종류 임플랜트 그룹 간에 통계학적으로 유의한 차이는 없었다(P>0.05). 본 연구에서 제한이 있긴 하지만, 임플랜트 디자인에서 생물학적 폭경이 부족한 경우(ITI esthetic plus, Silhouette IC)에는 생물학적 폭 경 보상을 위한 임플랜트 주위 변연골의 흡수가 있었음을 보여주고 있으나, laser를 이용한 microgroove 가 부여된 임플랜트에서는 collar의 거칠기와 laser microtexturing 등의 특징에 의해 임플랜트 주위 변연골의 흡수가 적게 일어난 것이 관찰되었다. 심미적인 요구도가 높은 전치부에서 충분한 생물학적 폭경이 확보된 임플랜트를 식립할 경우 변연골의 흡수에 따른 치은퇴축에 의해 metal collar의 노출이 우려되기에 충분한 생물학적 폭경이 부여되지 않은 임플랜트를 선정하게 되는데 이때 collar에서의 laser microtexturing은 변연골의 유지에 도움이 되었다. 이것은 조직의 단단한 부착으로 인한 안정화로 추정해 볼 수 있는데, 이에 대해서는 더 장기간의 연구와 더 많은 수의 임플랜트를 대상으로 한 연구와 조직학적인 연구도 필요할 것으로 사료된다.