• 제목/요약/키워드: density of paper

검색결과 6,508건 처리시간 0.035초

손상패턴의 확률밀도함수에 따른 구조물 손상추정 (Structural Damage Assessment Using the Probability Distribution Model of Damage Patterns)

  • 조효남;이성칠;오달수;최윤석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.357-365
    • /
    • 2003
  • The major problems with the conventional neural network, especially Back Propagation Neural Network, arise from the necessity of many training data for neural network learning and ambiguity in the relation of neural network structure to the convergence of solution. In this paper, the PNN is used as a pattern classifier to detect the damage of structure to avoid those drawbacks of the conventional neural network. In the PNN-based pattern classification problems, the probability density function for patterns is usually assumed by Gaussian distribution. But, in this paper, several probability density functions are investigated in order to select the most approriate one for structural damage assessment.

  • PDF

LIF를 이용한 Hg-Ar의 플라즈마 밀도 측정 (Plasma Density Measurement of Hg-Ar by LIF Method)

  • 최용성;황종선;박계춘;송민종;김형곤;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.27-32
    • /
    • 2006
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorcscent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\rightarrow}6^3P_2$) were larger than 404.8nm ($6^3S_1{\rightarrow}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

LIF를 이용한 Hg-Ar(1Torr)의 플라즈마 밀도 측정 (Plasma Density Measurement of the Hg-Ar(1Torr) by LIF Method)

  • 이종찬;박대희;양종경
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.213-217
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely This highlights the importance of measuring density distribution in plasma electric discharge mechanism study The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1 {\to} 6^3P_2$ ) were larger than 404.8nm ($6^3S_1 {\to} 6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

A Note On L$_1$ Strongly Consistent Wavelet Density Estimator for the Deconvolution Problems

  • Lee, Sungho
    • Communications for Statistical Applications and Methods
    • /
    • 제8권3호
    • /
    • pp.859-866
    • /
    • 2001
  • The problem of wavelet density estimation is studied when the sample observations are contaminated with random noise. In this paper a linear wavelet estimator based on Meyer-type wavelets is shown to be L$_1$ strongly consistent for f(x) with bounded support when Fourier transform of random noise has polynomial descent or exponential descent.

  • PDF

공심형 및 철심형 동기기의 특성해석 (Analysis on the flux density in Air-Cored and Iron-Cored type Syschrous Macl)

  • 장석명;조성국;윤인기;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.604-606
    • /
    • 2002
  • Air-cored machines have a higher efficiency with high frequency. speed than iron-cored machine because of the iron losses which may produce too much heat as well as the copper losses occurred in the rotor winding. But air-cored machine is lower flux than iron machine. The nature of the machine from 'iron-cored' to 'air-cored' is a progressive feature in the machines. A general analysis of the fields that is applicable to all configurations is presented. Slotless machines have been applied for no ripple induced voltage. In this paper, slotless mahcines equipped with internal 4-pole amature winding. This paper pay attention to analyze flux density of air-cored and iron-cored synchrous machine analytically and compare flux density of aired-cored machine to iron-cored machine.

  • PDF

신호 전이 밀도 전파 동작에 기초한 향상된 전력 평가 방법의 연구 (Improved Power Estimation Methodology Based on Signal Transition Density Propagation Behavior)

  • 김동호;우종정
    • 한국정보처리학회논문지
    • /
    • 제7권8호
    • /
    • pp.2520-2527
    • /
    • 2000
  • 전력 평가를 위한 전이 밀도 전파에 대한 개선된 방법을 제안한다. 제로 지연 모델을 위한 전력 평가는 전력 소모의 하한 경계 값에 대한 적절한 기준이다. 전력 예측을 위한 하한 값으로 제로 지연 모델을 사용한 전이 전파 방법에 대한 연구가 있지만 전이 밀도 전파 과정 중 잉여 요소들을 제거하지 못하였다. 본 연구에서는 전이 전파 밀도 동작을 분석함에 의하여 잉여 요소들을 제거할 수 있는 향상된 신호 전이 밀도 예측 기법을 제안한다. 실험에 의하면 제안된 방법이 기존의 방법에 비하여 상대적으로 양호한 예측 정확도를 나타낸다.

  • PDF

Modified Bone Density Fractionation Method for Palaeodietary Studies

  • Shin, Ji-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.83-88
    • /
    • 2011
  • The bone density fractionation method is a potential palaeodietary tool in tracing lifetime dietary changes as well as separating diagenetically altered fractions. This paper presents a workable bone density fractionation method that uses a devised mathematical model and the particle size distribution. Different grinding methods, i.e., a Spex $LN_2$ mill, a Disc mill and a Micronising mill, were used to reduce archaeological bone particles to an appropriate size range, which was then analyzed by a Laser particle sizer. It was found that density profiles are in good agreement with the diagenetic parameters, and with their stable isotope results.

고속의 직물 제직 공정에서 광학적 렌즈를 이용한 자동 밀도 측정 시스템 (Automatioc Density Measurement System Using Optical Lens in High Speed Textile Fabrication Process)

  • 이응주;현기호;정인갑
    • 한국정보처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.111-118
    • /
    • 1998
  • 직물의 밀도를 측정하는 작업은 직물 제직 공정에서 매우 중요한 사항이나 일반적으로 직물 제직 공장에서는 고속의 제직 라인에서 수작업에 의해 비효율적으로 행해지고 있다. 따라서 직물 제직 공정에서 직물의 포목 교정을 통해 고품질의 직물을 생산하기 위해서는 정확한 밀도 측정 과저잉 필수적인 사항이다. 본 논문에서는 고속의 제직 공정에서 광학적인 실린더 렌즈를 이용하여 직물의 위사 정보를 검출한 후 밀도 측정을 자동화함으로써 양질의 직물 생산과 직물 생산 효율을 극대화하고자 자동 밀도 측정 시스템을 제안하였다. 제안한 자동 밀도 측정 시스템은 고속의 직물 제직 공정에서 직물의 전체 영역에 걸쳐 일정한 밀도를 유지시켜 고품질의 직물 생산을 가능하게 하였다.

  • PDF

이중 밀도 웨이브렛 변환의 성능 향상을 위한 3방향 분리 처리 기법 (The Three Directional Separable Processing Method for Double-Density Wavelet Transformation Improvement)

  • 신종홍
    • 디지털산업정보학회논문지
    • /
    • 제8권2호
    • /
    • pp.131-143
    • /
    • 2012
  • This paper introduces the double-density discrete wavelet transform using 3 direction separable processing method, which is a discrete wavelet transform that combines the double-density discrete wavelet transform and quincunx sampling method, each of which has its own characteristics and advantages. The double-density discrete wavelet transform is nearly shift-invariant. But there is room for improvement because not all of the wavelets are directional. That is, although the double-density DWT utilizes more wavelets, some lack a dominant spatial orientation, which prevents them from being able to isolate those directions. The dual-tree discrete wavelet transform has a more computationally efficient approach to shift invariance. Also, the dual-tree discrete wavelet transform gives much better directional selectivity when filtering multidimensional signals. But this transformation has more cost complexity Because it needs eight digital filters. Therefor, we need to hybrid transform which has the more directional selection and the lower cost complexity. A solution to this problem is a the double-density discrete wavelet transform using 3 direction separable processing method. The proposed wavelet transformation services good performance in image and video processing fields.

고밀도 디스크를 위한 신호 품질 평가 방법 (Signal qualification method for high density disk)

  • 박현수
    • 정보저장시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.53-57
    • /
    • 2005
  • In order to measure signal quality of optical disc such as CD or DVD, jitter is used traditionally. The signal attained from a disc by optical pick-up is processed by analog circuits. And then, binary signal can be obtained by using proper silcer. After the signal is changed into binary format, jitter is calculated as a time difference between the binary signal and the reference time. Jitter is used to express the signal quality. In this paper, a new method that is able to offer more precise measurement of the signal quality fur high density optical disc than the jitter is proposed. We named it LPSNR (Level Peak Signal to Noise Ratio). The relationship between bER (bit error rate) and LPSNR is shown in the paper.

  • PDF