• Title/Summary/Keyword: demagnetization fault

Search Result 16, Processing Time 0.017 seconds

Geological Characteristics of Kyongju-Ulsan Area : Palaeomagnetism and Magnetic Susceptibility of the Granitic Rocks in the Ulsan Fault Area (경주-울산일원에 대한 지역지질 특성연구 : 울산단층주변 화강암류의 잔류자기와 대자율)

  • Kim, In-Soo;Son, Moon;Jung, Hyun-Jung;Lee, Joon-Dong;Kim, Jeong-Jin;Paik, In Sung
    • Economic and Environmental Geology
    • /
    • v.31 no.1
    • /
    • pp.31-43
    • /
    • 1998
  • A total of 469 granitic samples were collected from 44 sites in the Ulsan fault area, southeast Korea. According to the previous petrographic studies, the granitic rocks have been divided into four groups (Hornblende biotite granodiorite, Hornblende granite, Biotite granite and Alkali-feldspar granite). NRM intensities, values of low field magnetic susceptibility, and magnetic behaviors during stepwise demagnetization experiments suggest rather a three-fold classification: In this scheme, Hornblende granite and Biotite granite are grouped together, as they did not show any significant differences in magnetic characteristics. Based on the Ishihara (1979)'s criterion, Alkali-feldspar granite is classified as ilmenite-series granite, whereas others are classified as magnetite-series granite. In the eastern part of the study area including the Tertiary basin area, declinations of site-mean characteristic remanent magnetizations (ChRMs) show clockwise deflection of more than 30 from the reference direction of east Asia. Both along and in the adjacent region of the Ulsan fault-line, however, no deflection of remanent direction was observed. A boundary line between the deflected and undeflected site-mean ChRMs is defined in this study, which runs roughly parallel to the Ulsan fault-line at the distance of about 6km eastward from the fault-line. We suggest that this newly found boundary line, which we call Yonil tectonic line, released dextral simple shear stress acted in the southeastern part of the Korean peninsula during the opening stage of the East Sea in the Early Cenozoic.

  • PDF

Transient State Analysis of Network Connected to Wind Generation System (풍력발전시스템이 연계된 계통의 과도상태해석)

  • Kim, Se-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.29-35
    • /
    • 2003
  • Generator for wind power can be either synchronous or asynchronous (induction) types. Induction and synchronous generators behave in a different way when subjected to severe faults. Induction generators does not have an angle stability limit and short circuit in the neighborhood of an Induction generator causes the demagnetization of the machine when the fault is cleared, the voltage raises slowly, while the grid contributes with reactive power to the generator and the magnetic flux recovers. On the other hand in the synchronous generators the recovery of the voltage is immediate, since the excitation of the rotor angle comes from an independent circuit. This paper shows the result of the transient state analysis in the network connected to wind generation system Several case studies have been conducted to determine the effect of the clearing time of a fault on the network stability. It has been found that the critical clearing time can be as low as 61ms in the case of induction generator compared to 370ms in the case of synchronous generator.

The Geodynamic Evolution of the Chugaryeong Fault Valley in a View Point of Paleomagnetism (고지자기학적 관점에서 본 추가령단층곡의 생성과 진화)

  • 이윤수;민경덕;황재하
    • Economic and Environmental Geology
    • /
    • v.34 no.6
    • /
    • pp.555-571
    • /
    • 2001
  • The dynamic evolution of the Chugaryeong fault valley is studied by paleomagnetic works on 163 samples at 16 sites from Late Cretaceous and Quaternary volcanic rocks in the valley. Conglomerate test and stepwised thermal/alternating field demagnetization indicate that all the characteristic directions are of primary origin. Paleomagnetic pole ponsition(216.8$^{\circ}$E/7l .6$^{\circ}$N; dp=7.1$^{\circ}$, dm=10.0$^{\circ}$) for the upper par of the Jijangbong Volcanic Complex Is indistinguishable from the coeval retference pole position from the Gyeongsang Basin, which further substanciates the reliability of the Paleomagnetic data. This indicates the study area has not undergone any tectonic rotation since Late Cretaceous by uy significant reactivation of the Chugaryeong fault valley. The Quaternary pole position (134.2$^{\circ}$E/86.5$^{\circ}$N; $A_{95}$=7.1 $^{\circ}$) from the Jeongog Basalt reflects the present geocentric axial dipole field for the area, supporting the above conclusion. Unlike the upper part, paleomasnelic directions of the lower part of the Jijangbong Volcanic Complex show random distrinution between sites. We interpret that the early stage of the volcanic activity was created by sinistral strike slip motion of the Chugaryeong fault during early Late Cretaceous. The creation and evolution of the Chugaryeong fault valley emphasize the significance of the kinematic FR (folding ruler) model in east Asia.

  • PDF

Influence of Different Frequency Harmonic Generated by Rectifier on High-speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Yang, Cunxiang;Fan, Xiaobin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1956-1964
    • /
    • 2018
  • Since the stator winding of High-Speed Permanent Magnet Generator (HSPMG) has few winding turns and low inductance value, it is more prone to be influenced by harmonic current. Moreover, the operation efficiency and the torque stability of HSPMG will be greatly influenced by harmonic current. Taking a 117 kW, 60 000 rpm HSPMG as an example, in order to analyze the effects of harmonic current on HSPMG in this paper, the 2-D finite element electromagnetic field model of the generator was established and the correctness of the model was verified by testing the generator prototype. Based on the model, the losses and torque of the generator under different frequency harmonic current were studied. The change rules of the losses and torque were found out. Based on the analysis of the influence of the harmonic phase angle on torque ripple, it is found that the torque ripple could be weakened through changing the harmonic phase angle. Through the analysis of eddy current density in rotor, the change mechanism of the rotor eddy current loss was revealed. These conclusions can contribute to reduce harmonic loss, prevent demagnetization fault and optimize torque ripple of HSPMG used in distributed power supply system.

Palaeomagnetism of Cretaceous Rocks in the Ǔisǒng Area, Kyǒngsang Basin, Korea (의성지역 백악기 암석에 대한 고자기 연구)

  • Kim, In-Soo;Lee, Hyun Koo;Yun, Hyesu;Kang, Hee-Cheol
    • Economic and Environmental Geology
    • /
    • v.26 no.3
    • /
    • pp.403-420
    • /
    • 1993
  • The Cretaceous Kyongsang Basin is known to be composed of several tectonic blocks (or subbasins) with each distinct stratigraphic succession. The study area represents a major part of one of these blocks, i. e. the $\check{U}is\check{o}ng$ block. The area is charaterized by a suite of WNW-trending sinistral strike-slip faults as well as a number of ring faults. A total of 292 independently oriented core samples were drilled from 23 sites, covering virtually all the formations of the Cretaceous $Ky\check{o}ngsang$ Supergroup. Alternating field and thermal demagnetization experiments were conducted to reveal the primary magnetization. Due to the homoclinal nature of the strata in the area, it was not possible to make use of the conventional fold test It is, however, believed that the primary remanent components have been obtained from the majority of the formations, considering the similarity of the palaeomagnetic pole positions with those of contemporary strata of other blocks and the existence of antiparallel reversed remanence. It was found neither any significant difference in magnetic declination on each side of the strike-slip faults nor systematic change of magnetic declination with distance from the fault-line. This does not support such a block rotation hypothesis associated with the strike-slip faulting in the area as alleged by some authors. The samples from the outcrops on or near the fault-lines were severely overprinted by the recent magnetic fields regardless of age and lithology. Epithermal Au-Ag-Cu-Pb-Zn mineralizations are known along some fault lines in the area. It is interpreted that these two facts are closely related with fluid circulations along the fracture zones caused by fault activities. In regard to the age of the strata as deduced from the magnetostratigraphic consideration, the $Ch\check{o}mgok$ formation and the lower strata should be older than Barremian or 124 Ma. The age of volcanics of the $Yuch^{\prime}\check{o}n$ Group sampled in this study should be younger than Campanian or 83 Ma.

  • PDF

Palaeomgnetic Study on the Cretaceous Rocks in the Konchonri Area of the Northern Milyang Subbasin, Korea (밀양소분지 건천리 일원의 백악기 암석에 대한 고자기 연구)

  • Kang, Hee-Cheol;Kim, In-Soo;Yun, Sung-Hyo
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 2000
  • A palaeomagnetic study was carried out on Early through Late Cretaceous sandstones and volcanic sequences (the Songnaedong Formation, Chaeyaksan Volcanics, Konchonri Formation, and Jusasan Andesite it ascending order) from Konchonri area in the northern Milyang subbasin of the Kyongsang Basin, Korea. A high-temperature stable remanence with direction of $d=22.9^{\circ},\;i=59.1^{\circ}\;({\alpha}_{95}=3.0^{\circ})$ has been isolated and a corresponding pole was $71.6^{\circ}N,\;199.6^{\circ}E\;(A_{95}=4.2^{\circ})$. The characteristic high-temperature component resides in both hematite and magnetite. The primary nature of this remanence is confirmed from positive fold and reversals tests, The palaeopole is consistent with those of the Hayang Group in other parts of the Kyongsang Basin. A comparison of the palaeomagnetic pole position from the studied area with the contemporary pole from China west of the Tan-Lu fault presents that Konchonri area has experienced little latitudinal displacement nor vertical-axis block rotation relative to the Chinese blocks since the Cretaceous. Based on the formations indicating dual polarity, radiometric and paleontologic data, the magnetostratigraphic age of the studied sequence from the Songnedong Formation to the Jusasan Andesite ranges from upper Albian to lower Campanian reverse polarity chronozone. On the other hand, volcanic samples of the Chaeyaksan Volcanics and the Jusasan Andesite showed the scattered directions considered in group, even though individual sample showed a stable remanent magnetization in response to thermal demagnetization. It indicates that they have been reworked after acquisition of the stable remanent magnetization.

  • PDF