• Title/Summary/Keyword: delayed luminescence

Search Result 7, Processing Time 0.016 seconds

Delayed Luminescence of Biophotons from Plant Leaves

  • Sung, Baeck-Kyoung;Yi, Seung-Ho;Lee, Chang-Hoon;Yang, Joon-Mo;Kim, Jai-Soon;Soh, Kwang-Sup;Yang, Jong-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.132-136
    • /
    • 2004
  • Delayed luminescence of plant leaves was imaged by a 2-D cooled charge-coupled device. We report the delayed luminescence imaging of normal/injured leaves picked ami the leaves intact. The luminescent intensity was lower in leaf veins, scars and edge cut. The intensity of delayed luminescence from intact leaves was higher than that of picked leaves. These results indirectly support the argument that the delayed luminescence of a photosynthetic system is closely related to the electron transfer process of PSII in the thylakoid membrane.

Delayed Luminescence Characteristics of Human Hands (사람 손의 지연발광 특성)

  • Yang, Joon-Mo;Choi, Chun-Ho;Soh, Kwang-Sup;Lim, Woo-Taek;Lee, Han-Sang;Chae, Seung-Byung;Yoon, Se-Yeol;Lee, Kyung-Il;Shin, Eun-Seok;Choi, Sun-Mi
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.81-88
    • /
    • 2006
  • Delayed luminescence from human hands after illumination by light at different wavelength bands was studied. A delayed luminescence measurement system equipped with photomultiplier tube (PMT), fiber optics and automatic mechanical shutter system was developed. Three spectrum band-pass filters, fer which transmissions are on 350${\~}$450 nm, 450${\~}$550 nm and 550${\~}$650 nm, were used to select irradiation wavelength, and 150W metal-halide lamp was used as an illumination source. Six volunteers put their palms (dorsa) onto the measurement system, and after light illumination, delayed luminescence were measured for 10 minutes. The results show that delayed luminescence after shorter wavelength illumination was higher than that a(ter longer wavelength one. These results indicate the existence of accepters in human skin which can be excited at short wavelengths. Furthermore, each subjects showed different delayed luminescence curve patterns. Reactive oxygen species (ROS) are known to have important roles on delayed luminescence, and this research suggests that ROS concentration can be measured noninvasively with optical methods.

A Study on the Biophoton Emission of Cervi Pantotrichum Cornu (녹용(鹿茸)의 Biophoton(생체광자) 방출 특성 연구)

  • Park, Wan-Su;Lee, Chang-Hoon;Soh, Kwang-Sup;Kim, Ho-Cheol;Choi, Ho-Young;Park, Seong-Kyu
    • The Korea Journal of Herbology
    • /
    • v.21 no.2
    • /
    • pp.175-180
    • /
    • 2006
  • Objectives : The difference of delayed luminescence-biophoton emission was investigated in Cervi Pantotrichum Cornu selected randomly. Cervi Pantotrichum Cornu was used as a tonic in Korean medicine. Methods : Randomly selected samples of Cervi Pantotrichum Cornu were radiated with 150 W metal halide lamp for 1 minute. After radiation, biophoton emissions of each sample were detected by electron multiplication(EM)-charge coupled device camera. The detected biophoton image was calculated with unit of counts per pixel. Results : The average biophoton emissions of delayed luminescence with EM ratio of ${\times}l50\;and\;{\times}250$ were distinguished significantly. The maximum biophoton emissions of delayed luminescence with EM ratio of ${\times}250$ were distinguished significantly. Conclusion : These results suggest that biophoton imaging of Cervi Pantotrichum Cornu could become the meaningful method for the study of differentiation and classification of Cervi Pantotrichum Cornu.

  • PDF

Optimum Lens Organization and System Set-up for 2-Dimensional Imaging of Biophoton (생물 광자의 이차원 영상을 위한 렌즈계 최적화와 장치 구성)

  • Yi Seung-Ho;Shim Seong-Bo;Kim Jai-Soon;Yang Joon-Mo;Lee Changhoon;Soh Kwang-Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.519-526
    • /
    • 2004
  • We developed a 2-D imaging system to detect ultra weak biophoton by using a high sensitive fast CCD camera. We installed an illumination apparatus to generate delayed luminescence from plant leaves. Shutters at the illumination system and detector were synchronized to each other. The lens system of the CCD camera was newly designed to accommodate the specific requirements to enhance the collection efficiency for biophoton. Based on the lens simulation, commercial lenses were chose for the lens system. All the equipment was installed in a multi-purpose dark box and the delayed luminescence of Euonymus japonica was successfully acquired.

Study on Biophoton Emission from roots of Angelica sinensis D., Angelica acutiloba K., and Angelica pubescens M. (국내 수입되는 바디나물속 기원 한약재의 Biophoton(생체광자) 방출 특성 연구)

  • Park, Wan-Su;Lee, Chang-Hoon
    • The Korea Journal of Herbology
    • /
    • v.22 no.3
    • /
    • pp.39-45
    • /
    • 2007
  • Objectives : The purpose of this study is to investigate the delayed luminescence-biophoton emission from root of Angelica sinensis D., Angelica acutiloba K., and Angelica pubescens M. These three species of Genus Angelica are now imported from other nations into Republic of Korea. Methods : Randomly selected samples from roots of Angelica sinensis D., Angelica acutiloba K., and Angelica pubescens M. were radiated with 150 W metal halide lamp for 1 minute. After radiation. biophoton emissions of each sample were detected by electron multiplication(EM)-charge coupled device camera. The detected biophoton image was calculated with unit of counts per pixel. Results: The average biophoton emissions of delayed luminescence with EM ratio of $\times$150 and $\times$250 were distinguished significantly. The maximum biophoton emissions of delayed luminescence with EM ratio of $\times$250 were distinguished significantly. Conclusions : These results suggest that biophoton imaging of roots of Angelica sinensis D., Angelica acutiloba K., and Angelica pubescens M. could become the meaningful method for the study of differentiation for these three species of Genus Angelica.

  • PDF

Study on Biophoton Emission from roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K (한국 당귀, 중국 당귀, 일본 당귀의 생체광자(Biophoton) 방출 비교 연구)

  • Park, Wan-Su;Lee, Chang-Hoon;Soh, Kwang-Sup;Lee, Young-Jong;Lee, Choong-Yeo;Lee, Tae-Hee;Kim, Youn-Sub;Kim, Do-Hoon
    • The Korea Journal of Herbology
    • /
    • v.22 no.4
    • /
    • pp.95-100
    • /
    • 2007
  • Objectives : The purpose of this study is to investigate the delayed luminescence-biophoton emission from roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K These three species of Genus Angelica are now used as 'Danggui' in Traditional Korean Medicine. Methods : Randomly selected samples from roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K were radiated with 150 W metal halide lamp for 1 minute. After radiation, biophoton emissions of each sample were detected by electron multiplication-charge coupled device camera. The detected biophoton image was calculated with unit of counts per pixel. Results : The average and maximum biophoton emissions of delayed luminescence with electron multiplication ratio of ${\times}150$ and ${\times}250$were distinguished significantly between Angelica gigas N. and the other two species. Conclusions : These results suggest that biophoton imaging of roots of Angelica gigas N., Angelica sinensis D., and Angelica acutiloba K. could become the meaningful method for the study of differentiation between root of Angelica gigas N. and the other two species, Angelica sinensis D. and Angelica acutiloba K.

  • PDF

Light-Emission Characteristics of Organic Light-Emitting Diodes Driven by Alternating Current (교류 전압 구동에 의한 유기 발광 소자의 발광 특성 연구)

  • Kwon, Ow-Tae;Kim, Tae-Wan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.625-629
    • /
    • 2016
  • Electrical and optical properties of the AC voltage driven organic light-emitting diodes were investigated by measuring the electroluminescence of the device. Device structure of ITO(170 nm)/TPD(40 nm)/Alq3(60 nm)/LiF(0.5 nm)/Al(100 nm) was manufactured using a thermal evaporation. Sinusoidal and square-type AC voltage was applied to the device using a function generator. Amplitude of the applied voltage was 9.0 V, and a frequency was varied from 50 Hz to 50 kHz. Electroluminescence out of the device was measured in a Si photodetector simultaneously with the applied voltage together. An intensity and a delayed residual luminescence from the device were depended on the frequency of the sinusoidal voltage. It is thought to be due to a contribution of the capacitive nature in the equivalent circuit of the device. An electron mobility was estimated using a time constant obtained from the luminescence of the device driven by the square-type AC voltage.