• 제목/요약/키워드: degree-days

Search Result 1,746, Processing Time 0.027 seconds

Analysis of the cooling and heating degree days in the Seoul and Yeosu, where HadCM3 is applied (서울과 여수지역에 HadCM3를 적용한 냉」난방도일의 변화량 분석)

  • Yoo, Ho Chun;Noh, Kyoung Hwan
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.11-16
    • /
    • 2009
  • To act and respond to the climate changes and to bring about power-saving in buildings, the changes in the atmospheric data in Korea are recorded and assessed. For the two regions representative of Korea, the data obtained from HadCM3 and actual data are compared and analyzed so as to concretely evaluate and confirm the changes taking place in the cooling and heating degree days in Korea. For the past 40 years, from 1996 to 2005, the number of heating degree days was on the decline and in the two representative regions, between 1980's and 1990's, the number of decrease in the heating degree days had been quite large. The number of cooling degree days showed a trend of increase since the 1970's and just as in the case of heating degree days, the extent of increase was quite large between the 1980's and the 1990's. The results of comparison of the number of heating and cooling degree days, one obtained from the "Korea Meteorological Administration" and another from the HadCM3 data (E127.5,N37.5,E127.5,N35), which is one of the ways of predicting the climate, showed similar trends in the number of heating degree days in the Yeosu area. However, in the case of the number of heating degree days in Seoul and the number of cooling degree days both in Seoul and Yeosu, the differences in the number ranged from a minimum of 300 days to a maximum of 1500 days. This could be attributed to the grid points used in the HadCM3, the differences in the values of latitudes and longitudes of these two locations considered in this study, topographical differences, heat island effect caused by population density etc. and while using the HadCM3, these variables factors must be taken into consideration.

Analysis of Urban Warming Phenomenon using Degree days in Major Korean Cities (냉난방도일을 이용한 우리나라 주요도시의 도시승온화현상 특성분석)

  • Kim, Hae Dong;Park, Myeong Hui;Song, Gyeong Suk
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.189-196
    • /
    • 2004
  • Characteristics of urban wanning phenomenon were studied using degree days for three big cities(Seoul, Busan, Daegu) adjacent to airport. Time variation of the cooling and heating degree days was analyzed using the daily mean air temperature data measured at the six meteorological observatory for long-term periods(25~43years). The results for the big cities are as followings: 1) It was found that the heating degree days trended to decrease from year to year. 2) The cooling degree days were nearly unchanged during the same analysis periods. 3) The number of days calling for air-heating also tended to decrease as time passes. 4) Those of air-cooling were nearly unchanged during the same time. It suggests that the change of air-heating condition owing to urbanization came in evidence in the winter season, but that of air-cooling condition was slight in the summer season. On the other hand, the long-term trends of degree days were very small in airport areas except for Kimhae airport. Hence, the gaps of degree days between big cities and rural airport areas are increasing.

A Study on the Baseline Load Estimation Method using Heating Degree Days and Cooling Degree Days Adjustment (냉난방도일을 이용한 기준부하추정 방법에 관한 연구)

  • Wi, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.745-749
    • /
    • 2017
  • Climate change and energy security are major factors for future national energy policy. To resolve these issues, many countries are focusing on creating new growth industries and energy services such as smartgrid, renewable energy, microgrid, energy management system, and peer to peer energy trading. The financial and economic evaluation of new energy services basically requires energy savings estimation technologies. This paper presents the baseline load estimation method, which is used to calculate energy savings resulted from participating in the new energy program, using moving average model with heating degree days (HDD) and cooling degree days (CDD) adjustment. To demonstrate the improvement of baseline load estimation accuracy, the proposed method is tested. The results of case studies are presented to show the effectiveness of the proposed baseline load estimation method.

Study on the Revision of HDD for 15 Main Cities of Korea (국내 15개 주요지역의 난방도일 재산정에 관한 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Choi, Chang-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.436-441
    • /
    • 2010
  • The purpose of this study is to revise the HDD(Heating Degree-Days) of main cities of Korea because the outside temperature rise have been accelerated by global warming recently. Now our HDD(Heating Degree-Days) for the utility design of district heating system had been `established in 20 years ago. Therefore new heating degree days for main cities of korea had been required and determined using long-term measured outside weather temperature data during 30 years. For the analysis of HDD, five different base temperatures ranging from 24 to $16^{\circ}C$ were chosen in the calculation of heating degree days. And new yearly heating degree days of 15 cities of korea were given in the tabular form.

Study on the revision of Heating Degree-days for Korea (국내 난방도일의 재정립에 관한 연구)

  • Kim, Seong-Su;Cho, Sung-Hwan;Choi, Chang-Yong;Kim, Sang-Ho;Kim, Youn-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.17-22
    • /
    • 2007
  • Global average temperature rise accelerates by global warming in the three decades of the 20th century. But now we use heating degree days which was established 20 years ago. Therefore new heating degree days for 15 district areas of korea was determined using long-term measured data. Five different base temperatures ranging from 24 to $16^{\circ}C$ were chosen in the calculation of heating degree days. And yearly heating degree days were given in the tabular form.

  • PDF

A Study on the Cooling Degree Days and the Number of Cooling Days in Korea (우리나라의 냉방도일과 냉방일수에 관한 연구)

  • Seol, Dong-Il;Min, Byeong-Eon
    • Journal of the Korean Institute of Navigation
    • /
    • v.15 no.4
    • /
    • pp.41-58
    • /
    • 1991
  • The cooling degree days and the number of cooling days are used as important research materials not only in the field of design for building and cooling facilities but also in the government's establishment of energy policy. The purposes of this dissertation are to clarify the distribution of the cooling degree days and the number of cooling days by using the daily mean air temperature of 95 weather stations in Korea, and to show the distribution charts of the same cooling degree days and the same number of cooling days in order to help the practical uses of the materials. In cases of the base temperatures $24^{circ}C$, $25^{circ}C$, $26^{circ}C$, and $27^{circ}C$, the cooling degree days and the number of cooling days are shown in Table 5. The distribution charts of the same cooling degree days and the same number of cooling days are shown in Fig. 6 to Fig. 8 and Fig.9 to Fig. 11 respectively. As a result of this dissertation, Jeju Island and southern inland regions(especially Jeonju, Daegu, Gwangju) have a larger value than central regions and northern regions because of the influences of the terrain effect, and western coast regions have usually a larger value than eastern coast regions at the same latitude. The largest value appears in August of the year and the second in July, and the smallest in September. And southern inland area surrounded by Imshil, Goechang, and Boeun has a much smaller value than the other areas of its vicinity.

  • PDF

A Study on the Classification Criteria of Climatic Zones in Korean Building Code Based on Heating Degree-Days (난방도일 기반 대한민국 행정구역별 기후존 구분 기준 정립에 관한 연구)

  • Noh, Byeong Il;Choi, Jaewan;Seo, Donghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.574-580
    • /
    • 2015
  • Climatic zone in building code is an administrative district classification reflecting regional climatic characteristics. Use of Degree-Days is a fundamental method that can be used in various building design codes, analysis of building energy performance, and establishment of minimum thermal transmittance of building envelopes. Many foreign countries, such as the USA, the EU, Australia, Italy, India, China, etc., have already adapted climatic zone classification with degree-days, precipitation or amount of water vapor based on the characteristics of their own country's climate. In Korea, however, the minimum requirements for regional thermal transmittance are classified separately for the Jungbu area, Nambu area and Jeju Island with no definite criterion. In this study, degree-days of 255 Korean cities were used for climatic zone classification. Outdoor dry-bulb temperature data from the Korea Meteorological Administration for 1981~2010 was used to calculate degree-days. ArcGIS and the calculated degree-days were utilized to analyze and visualize climatic zone classification. As a result, depending on the distribution and distinctive differences in degree-days, four climatic zones were derived : 1) Central area, 2) Mountain area of Gyeonggi and Gangwon provinces, 3) Southern area, and 4) Jeju Island. The climatic zones were suggested per administrative district for easy public understanding and utilization.

A Study on Generating Process of Regional Balance Point Temperature for Heating Degree-days in Korea (국내 난방도일의 지역별 균형점온도 산정 과정에 관한 연구)

  • Park, So Min;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.482-495
    • /
    • 2017
  • Degree-days are practically used as a tool to estimate energy consumption for heating and cooling. Degree-days are calculated by summing differences of balance point temperature and outside temperature for the analyzed period. Determining balance point temperature is a key point in calculating accurate degree-days. However, ASHRAE standards are used for balance point temperature in Korea because balance point temperature considering climate conditions and building thermal performance is not proposed in Korea. This study proposes the process to generate balance point temperature for heating degree-days considering Korean climate and building conditions. Also, a new balance point temperature for three regions in Korea will be suggested in this study. Balance point temperature of Seoul is approximately $15.0^{\circ}C$, lower than the current standard of $18.3^{\circ}C$. Balance point temperature of Seoul considering climate conditions and building performance can be different from the ASHRAE suggested value ($18.3^{\circ}C$). Results revealed the current standard for balance point temperature should be changed considering climate and building conditions in Korea.

Study on the revision of HDD for 15 District Areas of Korea (국내 주요지역의 난방도일 재산정에 관한 연구)

  • Cho, Sung-Hwan;Kim, Seong-Su;Kim, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.943-948
    • /
    • 2008
  • Global average temperature rise accelerates by global warming in the three decades of the 20th century. But Current HDD ( Heating Degree-Days) which we are using has been established 20 years ago. Therefore new heating degree days for 15 district areas of korea was determined using long-term measured data. Five different base temperatures ranging from 24 to $16^{\circ}C$ were chosen in the calculation of heating degree days. And yearly heating degree days were given in the tabular form.

  • PDF

Effects of Accelerated Iso-Thermal Aging on Elastic-Plastic Fracture Toughness and Fracture Resistance Curve by Unloading Compliance Method in SA533B Low Alloy Steel (제하 컴플라이언스법에 의한 SA533B강의 $J_1C$ 및 J-R 곡선에 미치는 열시효 영향)

  • 윤한기;차귀준
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.157-165
    • /
    • 1994
  • Effect of an accelerated iso-thermal aging (375 degree C x 66days, 375 degree C x 200days) on elastic-plastic fracture resistance curve were examined in SA533B low alloy steel. Fracture toughness test are conducted by unloading compliance method at room temperature. But the apparent negative crack growth phenomenon, usually arise in partial unloading compliance test. The phenomenon of negative crack growth may be eliminated by the offset technique. There is no effect of aging on J sub(IC) and dJ/da in iso-thermal aged (375 degree C x 66 days) specimen, but there is very little effect in iso-thermal aged (375 degree C x 200 days) specimen.

  • PDF