• Title/Summary/Keyword: degree of grafting

Search Result 107, Processing Time 0.025 seconds

Synthesis and Non-Isothermal Crystallization Behaviors of Maleic Anhydride onto High Density Polyethylene

  • Ahn, Youngjun;Jeon, Jong Hyuk;Baek, Chul Seoung;Yu, Young Hwan;Thenepalli, Thriveni;Ahn, Ji Whan;Han, Choon
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.1
    • /
    • pp.24-33
    • /
    • 2016
  • The grafting reaction for maleic anhydride (MA) onto high density polyethylene (HDPE) was investigated from solution process with initiators. The chemical modification of neat HDPE was carried out with various contents of MA (3-21 wt.%) and initiator (0.2-1 wt.%) at different temperature ($80-130^{\circ}C$). The grafting degree was obtained from the titration and the highest grafting degree was 3.1%. The grafting degree increased as the content of MA and initiator increased, however, the highest grafting degree was demonstrated for a particular content of MA and initiator. In the non-isothermal crystallization kinetics, the Ozawa model was unsuitable method to investigate the crystallization behavior of MA onto HDPE, whereas the Avrami and Liu models found effective. The crystallization rate was accelerated as the cooling rate increased, but postponed by combination of MA onto neat HDPE backbone.

Melt Grafting of Citraconic Acid onto an Ethylene-Propylene-Diene Terpolymer (EPDM) -Effect of Reaction Conditions and Initiator Type on the Melt Grafting of Citraconic Acid onto EPDM- (EPDM고무와 씨트라코닉산의 melt grafting - 반응조건과 개시제에 따른 영향 연구 -)

  • Kim, Jung-Soo;Bae, Jong-Woo;Lee, Jin-Hyok;Oh, Sang-Taek;Kim, Gu-Ni;Lee, Young-Hee;Kim, Han-Do
    • Elastomers and Composites
    • /
    • v.48 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • Melt grafting of citraconic acid (CCA) onto an ethylene-propylene-diene terpolymer (EPDM) with various peroxide initiators was performed using a Haake Rheocorder. Finding the optimum running condition and concentration is critical for effective grafting and performance of grafted material. Therefore, this study focused on the effects of mixing (reaction) condition and monomer/initiator dosages on the grafting degree, grafting efficiency and crosslinking degree (gel content), melt flow index and mechanical properties of CCA-g-EPDM. As the grafting degree/crosslinking degrees increased, the tensile strength increased significantly, but elongation at break and melt flow index decreased. The initiator 2,5-dimethyl-2,5-di(tert-butyl peroxy)-hexane (T-101) appeared to meet for the best grafting(2.31%). The grafting degree increased markedly with increasing monomer CCA/initiator T-101 contents. The grafting degree also increased with increasing mixing temperature/time, and then leveled off or decreased/increased a little. The optimum monomer/initiator dosages and reaction temperature/time were found to be about 5/0.05 wt% and $180^{\circ}C$/15min, respectively.

Graft Copolymerization to Proteins (I). Cerium (IV) Ion-Initiated Graft Copolymerization of Vinyl Monomers to Silk Fibroins (단백질에 대한 그라프트 공중합 (제1보). Cerium (IV) 이온에 의한 비닐 단위체의 견섬유에 대한 그라프트 공중합)

  • Iwhan Cho;Kwang-Duk Ahn
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.4
    • /
    • pp.299-308
    • /
    • 1976
  • Cerium (Ⅳ) ion-initiated graft copolymerizations of acrylamide and of acrylonitirile to silk fibroins were investigated. When acrylamide was used, the change in ceric ammonium nitrate concentration exhibited a maximum in degree of grafting at 0.01 M. Also observed was that the change in acetic acid content in reaction media gave a maximum in degree of grafting at 7% acetic acid in water. Degree of grafting was increased generally with increase in acrylamide concentration reaction time and reaction temperature. When acrylonitrile monomer was used for grafting,different results were obtained. Addition of nitric acid was more effective in enhancing the degree of grafting than the addition of acetic acid.Generally the grafting of acrylonitrile to silk fibroins was less efficient than the grafting of acrylamide. The portion of grafted silk fibroins insoluble in Lowe's reagent exhibited the IR absorption bands characteristics to both vinyl polymers and silk fibroins, indicating the grafting of vinyl monomers to silk fibroins. To examine the molecular weight of graft vinyl polymer, a sample of grafted silk was hydrolyzed by 10% sodium hydroxide. Viscosity measurements indicated that the molecular weight of the graft polymer was in the range of 105.

  • PDF

Preparation and Characterization of Acrylic Acid Grafted Polypropylene Nonwoven Fabric (아크릴산 그라프트 폴리프로필렌 부직포의 제조와 특성)

  • Kim, Sang-Yool;Na, Choon-Ki
    • Fashion & Textile Research Journal
    • /
    • v.6 no.3
    • /
    • pp.384-392
    • /
    • 2004
  • The purpose of this study is in development of effective filter-type polymer adsorbent for removal of pollutants from wastewater by UV irradiation graft polymerization. Photografting of acrylic acid (AA) on polypropylene (PP) nonwoven fabric using benzophenone (BP) as a photosensitizer was investigated. Inhibition of homopolymerization was achieved by adding various concentrations of $FeSO_4{\cdot}7H_2O$, $CuSO_4{\cdot}5H_2O$ and Mohr's salt. As AA concentration was increased, the degree of grafting was increased as to a specific value and then decreased, and the effect of BP concentration showed the same tendency. It was also found that the degree of grafting increased with reaction time and reaction temperature. Addition of the polyfunctional monomers and $H_2SO_4$ to the grafting system accelerated the photografting. The melting temperature, molecular weight and breaking stress and breaking strain were decreased with the increase in the degree of grafting.

Preparation and Characteristics of Polypropylene Nonwoven Fabric Grafted by Styrene (스티렌 그라프트 폴리프로필렌 부직포의 제조와 특성)

  • Kim, Sang-Yool;Na, Choon-Ki
    • Fashion & Textile Research Journal
    • /
    • v.6 no.3
    • /
    • pp.377-383
    • /
    • 2004
  • Photografting of styrene (St) on polypropylene (PP) nonwoven fabric using benzoin ethyl ether (BEE) as a photosensitizer was investigated. Inhibition of homopolymerization was achieved by adding various concentrations of $FeSO_4{\cdot}7H_2O$, $CuSO_4{\cdot}5H_2O$ and Mohr's salt. As St concentration was increased, the degree of grafting was increased as to a specific value and then decreased, and the effect of BEE concentration showed the same tendency. It was also found that the degree of grafting increased with reaction time and reaction temperature. Addition of the polyfunctional monomers and $H_2SO_4$ to the grafting system accelerated the photografting. The melting temperature, molecular weight, tensile strength and elongation were decreased with the increase in the degree of grafting.

Preparation of Modified Hollow Polypropylene Membrane and Their Adsorption Properties of ${\gamma}$-Globulins

  • Hwang, Taek-Sung;Park, Jin-Won
    • Macromolecular Research
    • /
    • v.11 no.5
    • /
    • pp.347-351
    • /
    • 2003
  • The hydrophobic ligand-containing hollow polypropylene (PP) membranes were synthesized by the mutual radiation induced graft copolymerization with glycidylmethacrylate (GMA) onto hollow PP membrane followed by the subsequent functionalization with L-phenylalanine. FT-IR, elemental analysis and UV spectroscopy were utilized to characterize copolymer composition, and degree of grafting, functionalization conversion and ${\gamma}$-globulins adsorption. The degree of grafting on the PP surface increased with the reaction time and total dose of E-beam. In the subsquent functionalization, the amount of L-phenylalanine increased with the increase in the degree of grafting and the degree of conversion was about 30%. The ${\gamma}$-globulins adsorption experiments showed that adsorption capacity had a maximum value at pH 8. The ${\gamma}$-globulins adsorption capacity in the basic pH region was higher than in the acidic pH region.

Synthesis and Their Properties of PP Graft Copolymers by E-beam Radiation and Vapor Phase Reaction (전자선 조사 기상 반응에 의한 PP 기재 공중합체의 합성과 특성)

  • 황택성;박진원;이재천
    • Polymer(Korea)
    • /
    • v.26 no.3
    • /
    • pp.287-292
    • /
    • 2002
  • Graft copolymerization of styrene and glycidyl methacrylate (GMA) to the peroxidized polypropylene (PP) fabric with E-beam in $O_2$ atmosphere was carried out in vapor phase with benzoyl peroxide (BPO) as an initiator. The degree of grafting of copolymers was increased with the increase of the reaction temperature and the highest degree of grafting was obtained at $70^{\circ}C$ with styrene, and at $80^{\circ}C$ with GMA. The highest degree of grafting of styrene grafted PP according to reaction time was higher than that of GMA grafted PP. In vapor phase graft polymerization, the degree of grafting of copolymers according to water composition in monomer mixture was effected by the boiling temperature of monomers.

Surface Metallization of Polyethylene Films Modified by Radiation Grafting of N-vinyl Pyrollidone (감마선 자극에 의한 금속이온 이식 도전성 폴리머)

  • A. Aal;V. V. Khutoryanskiy;Z. S. Nurkeeva;G. A. Mun;Soh, Dea-Wha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.403-406
    • /
    • 2003
  • Poyethylene(PE) films could be modified by radiation grafting of N-vinyl pyrollidone(NVP) using radiation. FTIR spectra was used to confirm the modification of PE films. The modified films were activated by one-step or two-step methods for electroless Cu plating. Morphology of metallized films has been investigated. Electroless Cu plating onto the modified films depends mainly on the grafting degree and activation type. The electrical conductivity and adhesion of the metallized films has been investigated and tested in regard of grafting degree of samples.

  • PDF

Melt Grafting of EPDM and Itaconic Acid: Effect of Reaction Conditions and Initiator Type/Concentration (Ethylene-propylene-diene terpolymer (EPDM)와 itaconic acid의 melt grafting: 반응조건과 개시제 종류 및 농도의 영향)

  • Kim, Ki-Jae;Bae, Jong-Woo;Kim, Jung-Soo;Lee, Jin-Hyok;Kim, Gu-Ni;Oh, Sang-Taek;Kim, Wonho
    • Elastomers and Composites
    • /
    • v.49 no.3
    • /
    • pp.181-190
    • /
    • 2014
  • Melt grafting of itaconic acid (IA) onto an ethylene-propylene-diene terpolymer (EPDM) with various organic peroxide initiators was performed. Finding the optimum mixing conditions and concentration of ingredients is critical for effective grafting and optimum properties of grafted materials. This study focused on the effects of mixing conditions (temperature and time), initiator type/concentration and monomer concentration on the grafting degree and efficiency, melt flow index, and gel content of EPDM-g-IA. The initiator, 2,5-dimethyl-2,5-di(tert-butyl peroxy)-hexane (T-101), appeared to meet for the best grafting degree (1.91%). The grafting degree increased markedly by increasing the amounts of monomer IA and initiator T-101. The grafting degree also increased by increasing mixing temperature and time. The optimum monomer and initiator concentrations and reaction temperature and time were found to be about 5wt%/0.05wt% and $160^{\circ}C$/15min, respectively. It was found that the physical properties of EPDM-g-IA were higher than those of the pristine EPDM.

Preparation of Anion-exchange Membrane for Selective Separation of Urea and Ion (요소(Urea) 및 이온의 선택적 분리를 위한 음이온교환막의 제조)

  • Kim, Byoung-Sik;Kim, Min;Heo, Kwang-Beom;Hong, Joo-Hee;Na, Won-Jae;Kim, Jae-Hun
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.303-309
    • /
    • 2006
  • In this study, functional anion-exchange membranes have been prepared and characterized to improve the permeation fluxes of the anion and urea for peritoneum dialysis. They were prepared by UV and radiation graft polymerization methods. The separation-membrane prepared by UV graft polymerization showed the highest grafting degree when HEMA and VBTAC were mixed by 1:2 ratio. However, the grafting degree decreased slightly at compositions above the 1:2 ratio because of the disruption of UV penetration caused by build-up of homopolymer. In the case of photo-initiator, the grafting degree increased up to 0.2 wt%, above which it decreased to a small extent. For the two membranes prepared by radiation graft polymerization, the VBTAC/HEMA membrane showed 96% grafting degree for 6 h reaction time and the GMA membrane showed over 100% grafting degree for 2 h reaction time. Anion-exchange membranes were prepared with 113% grafting degree and with DEA and TEA exchange groups. The DEA membrane showed the conversion degree of 70% in 4 h reaction time while the TEA membrane showed 30% in 2 h reaction time. The prepared anion-exchange membranes were permeable to only anions and urea, but not cations.