• Title/Summary/Keyword: deformation of drain

Search Result 38, Processing Time 0.026 seconds

A Perfomance Evaluation of the Deformation-Compatible Vertical Drain (DCVD 배수재의 성능평가)

  • Song, Seok-Kyu;Chun, Youn-Chul;Shim, Jai-Beom;Shim, Seong-Hyeon;Kim, Young-Uk;Lee, Seok-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.692-701
    • /
    • 2009
  • The use of vertical drain method to improve the soft soil ground has been continuously increased in Korea such as Busan New Port, Saemangeum reclamation project and so on in Korea. Especially PBD(Plastic Board Drain), one of the vertical drain, has been widely used due to the economic feasibility, construction compatibility and quality control. However in case of using PBD, discharge capacity reduction caused by creep deformation of the PBD filter, bending, kinking and so on can be occurred. Therefore the purpose of this study is to solve these problems by developing Deformation-Compatible Vertical Drain, DCVD which allows to deform with consolidation settlement without bending and kinking of vertical drain. In order to investigate the performance of DCVD developed in this study, discharge capacity test, centrifuge model test and complex discharge capacity test for both PBD and DCVD are performed and the results are compared.

  • PDF

KINKING DEFORMATION OF PVD UNDER CONSOLIDATION OF NATURAL CLAY LAYER

  • Aboshi, Hisao;Inoue, Toshiyuki;Yamada, Yoshimitsu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.349-356
    • /
    • 2003
  • Almost every material of PVD (Prefabricated Vertical Drain) has the fatal problem on the condition - the length must shorten with the settlement of the surrounding grounds - which all PVDs must satisfy. Kinking deformation by buckling of PVD due to consolidation settlement Is discussed in this paper. A new testing device to clarify the deformation of PVD under consolidation of surrounding clay was developed and the fiber drain and a PVD made of plastics were compared under the same condition of consolidation using natural clay specimens. The results are also shown in this paper.

  • PDF

An Evaluation on the Result of Pilot Test for Soft Grounnd Improvement in Asan (아산지역에서의 연약지반개량을 위한 시험시공 결과에 대한 평가)

  • 이재원;김성인
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.615-622
    • /
    • 2000
  • This paper is relate to the result of pilot test in Asan. In order to evaluate the characteristics of behavior and deformation in Asan and to analyse the effect of soft ground treatment, preloading, two types of paper drain and pack drain were constructed in the ground. Settlement gauges, pressure meters, pressure cells and ground water gauges were monitored and also borings and piezoncone tests were performed. As a result of analyse, every vertical drained area was consolidated over 90% degree of consolidation but preloaded area was not reached to 90%.

  • PDF

Deformation Analysis of Soft Foundation with Vertical Drain Wells using the Interface Element Method -With Emphasis on Model Foundation and Actual Sand Drain Well Foundation- (접합요소에 의한 Vertical Drain Well 지반의 변형해석 - 모델지반과 실제 Sand Drain Well 지반을 중심으로 -)

  • Lee, Jean Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.227-237
    • /
    • 1993
  • This paper dealt with numerical analysis of sand drain considering the smear effect around drain wells and discontinuous deformation behavior due to difference in rigidity between drain materials and adjacent clayey soils. Biot's equation was selected as governing equation coupled with MODCAM (Modified Cam-clay) model or EVP(Elasto-Viscoplastic) model as constitutive equation. The validity as well as the accuracy of the method developed by author was checked by comparing the proposed method with those by Siriwardane and Ghaboussi using joint element. The FEM analysis developed in this study was applied to both 2-dimensional model foundation and actual foundation. the result of which proved to be satisfactory.

  • PDF

The Applicability of Numerical Analysis Technique to The Soft Clayey Foundation Improved by Sand Drain (Sand Drain 지반에 대한 변형해석법의 적용성)

  • Lee, Jean-Soo;Lee, Moon-Soo;Jang, Chul
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.1
    • /
    • pp.96-105
    • /
    • 1998
  • Soil properties, drain conditions and numerical analysis technique have great influence upon consolidation behavior. In relevant to the above described fact, this paper aims to examining the applicability of prediction model of consolidation as well as deformation characteristics for soft clayey foundation improved by sand drain. A case study for actual foundation of Kwangyang steel works was performed. Single drain consolidation model proposed by Hansbo and Biot's consolidation theory coupled with modified Cam-clay model developed during the research were employed for the FEM numerical analysis of the foundation. Both smear effect and drain capacity were taken into account for the analysis. Finally the applicability of the newly developed technique to the behavior of foundation composed of soft clay proved satisfactory.

  • PDF

Deformation Demand of the Precast Concrete Frame Buildings with Ductile Connection in Moderate Seismic Regions (연성적인 접합부를 가진 프리캐스트 콘크리트 골조건물의 변형수요)

  • 서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.89-98
    • /
    • 1999
  • This paper evaluates nonlinear response characteristics of precast concrete frame buildings. where plastics hinging occurs in the precast connection. Designs were developed for buildings of 5, 10 and 15 stories in hight for moderate seismic risk regions of the U. S. The responses of the buildings were analyzed using DRAIN-2DX and following Nonlinear static analysis procedure of ATC 19. The main variables of the analyses were the strength and stiffness of the connection. Also, for the analysis, the bi-linear response model, developed and inserted into the DRAIN-2DX program by Shan Shi and D. Fouch, was used. With the results of analysis, the deformation demands of the connection of precast concrete frame buildings are proposed by using equal-dissipated energy capacity. It was shown that the strength of the buildings as well as their displacement capacities decreased with the decrease of either the strength or stiffness in the connections. Therefore such changes also require reductions in the response modification factors for such buildings. However, if the precast concrete frame building has plastic hinging in the connection, and has a more ductile connection than the monolithic frame building, then no reduction in R may be necessary. The deformation demand required of the connection to achieve that condition is evaluated and a simple relation is suggested in the paper.

Effect of Loading Rate to Bearing Capacities (지지력에 미치는 재하속도에 관한 해석적 연구)

  • 박중배
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.147-158
    • /
    • 1997
  • In this study, it is examined that partial drain has an effect of bearing capacities and deformations on intermediate soils. To compare the numerical and experimental results, this study uses CRISP90 which is composed of Modify Cam-Clay Model for calculation and Geotechnical Centrifuge in model test. As the results of analysis, we can classify relative loading rate into three ranges which are drain, undrain and partial drain. Besides it is proved that partial drain range is about 103.

  • PDF

Experimental Study on the Reduction of the Discharge Capacity of Vertical Drains (연직배수재의 통수능력 저감요인 분석을 위한 실험적 연구)

  • Kim, Chan-Kee;Chae, Young-Su;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.3
    • /
    • pp.3-10
    • /
    • 2005
  • This paper aims at investigating the characteristics of discharge capacity according to lateral pressure, hydraulic gradient and deformation of drain materials. A series of experiments were conducted to achieve this objective. In experiments, fiver drain boards as well as harmonica and castle types of drain boards were installed in a rubber membrane, and clay in sully was filled around them. The test results showed that the harmonica type of drain boards have the greatest discharge capacity comparing to castle and fiber drain boards. The results also indicated that the hydraulic gradient has more effect on reduction of discharge capacity than the lateral pressure.

  • PDF

연약지반 변형해석을 위한 다목적 Program개발

  • 박병기;정진섭
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1991.10a
    • /
    • pp.362-375
    • /
    • 1991
  • Background and Necessity of the study : For more than 20 years, the soil engineering reserach group of Chonnam National University has been performing the deformation analysis of soft clayey foundation, since the University is located near the south-western coast of Korean Peninsulla, along which tide reclamation works have been under proaressing. Associsted with the fact mentioned above, the researchers have been developing a computer program in order to carry out deformation analysis of soft foundation since early 1980. Case-studies : In this research, the Biot's equation was selected as the governing equation coupled with several constitutive models including original and modified Cam-clay models, elasto-viscoplastic model, Lade's model etc. The anisotropy of soi1 can be considered in this program. To validate the accuracy of the computer program developed a couple of case-studies were performed. These include the pilot banking, sand drain considering smear effect and compound foundation reinforced with sheet pile into soft foundation.i) The pilot banking Good results could be acquired by assuming banking load as the body force composed of finite element mesh rather than equivalent concentrated load.ii) The sand drain Due to smear, the delay of consolidation was remarkable at the early stsge. so safety for the failure of foundation should be checked for the initial step of consolidation. iii) The compound foundation Accurate results were obtained by introducing the joint element method for the soft foundation reinforced with sheet pile into soiㅣ.

  • PDF

Application of Numerical Analysis for Sand Drain by the Multi-purpose Program of Soft Foundation Analysis (연약식반교양공법에 이용될 범용프로그램의 Sand Drain 공법에의 적용)

  • 박병기;정진섭
    • Geotechnical Engineering
    • /
    • v.1 no.2
    • /
    • pp.17-26
    • /
    • 1985
  • This study was carried out for the purpose of comparing in reference to sand drain in the next three different cases. First, The case of drain material (sand pile) has some rigidity during embankment and consolidation. Second, In usual case of no rigidity as a paper drain without permeability during embankment and consolidation Third, Check up clay behavior when above the two cases carried out respectively. This FEM analysis is consisted with Biot's consolidation equation when it is used for Christian Boehmer's numerical technique. The main results are obtained from above the Analysis When sand drain has some rigidity, the lateral and vertical deformation of clay foundation is restrained considerable amount and .exhibited bearing capacity of load as a pile According to the foundation in drained condition and untrained condition, the results are much variable in this analysis method. Also, The behaviors of stress path and pore water pressure met our expectation during , consolidation. This analysis should be considered to put into use of sand drain and design in future.

  • PDF