• Title/Summary/Keyword: defect type

Search Result 1,073, Processing Time 0.032 seconds

Surgical Repair of Interruption of the Aortic Arch[Type A] -A Report of 5 Cases- (대동맥 결손증 (Type A) 의 외과적 치험)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.665-671
    • /
    • 1988
  • Between 1981 and 1987, five patients with an interruption of the aortic arch were operated upon. All had a ventricular septal defect and a patent ductus arteriosus as associated anomalies. A two-stage procedure was employed in these cases, the initial procedure being repair of the interrupted arch, ligation of the patent ductus arteriosus, banding of the main pulmonary artery and a lung biopsy which was followed, 5 to 49 months later, by the repair of the ventricular septal defect. Four patients completed the two-stage procedure with one postoperative mortality. The remaining patient is yet to complete the second stage procedure.

  • PDF

Closure of meningomyelocele defects using various types of keystone-design perforator island flaps

  • Putri, Nandita Melati;Tunjung, Narottama;Sadikin, Patricia Marcellina
    • Archives of Plastic Surgery
    • /
    • v.48 no.3
    • /
    • pp.261-268
    • /
    • 2021
  • Background Various methods have been described to close large meningomyelocele defects, but no technique has been proven superior to others. This study presents cases of meningomyelocele defect closure with a keystone-design perforator island flap. Methods A retrospective study was performed on 14 patients with meningomyelocele defects closed using various types of keystone flaps. Results The median age of the patients at surgery was 10.5 days (range, 1-369 days) and the average defect size was 22.5 cm2 (range, 7.1-55.0 cm2). The average operative time for defect closure was 89.6 minutes (range, 45-120 minutes). Type IV bilateral keystone flaps were used for four defects, type IV unilateral flaps for six defects, type IIA flaps for two defects, and type III flaps for two defects. Conclusions All the defects healed completely with no major complications. The keystone-design perforator island flap is a reliable, easy, and fast technique to close large meningomyelocele defects.

Defect detection of wall thinning defect in pipes using Lock-in photo-infrared thermography technique (위상잠금 광-적외선 열화상 기술을 이용한 감육결함이 있는 직관시험편의 결함 검출)

  • Kim, Kyoung-Suk;Jang, Su-Ok;Park, Jong-Hyun;Choi, Tae-Ho;Song, Jae-Geun;Jung, Hyun-Chul
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.317-321
    • /
    • 2008
  • Piping in the Nuclear Power plants (NPP) are mostly consisted of carbon steel pipe. The wall thinning defect is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid which flows in carbon steel pipes. This type of defect becomes the cause of damage or destruction of piping. Therefore, it is very important to measure defect which is existed not only on the welding partbut also on the whole field of pipe. Over the years, Infrared thermography (IRT) has been used as a non destructive testing methods of the various kinds of materials. This technique has many merits and applied to the industrial field but has limitation to the materials. Therefore, this method was combined with lock-in technique. So IRT detection resolution has been progressively improved using lock-in technique. In this paper, the quantitative analysis results of the location and the size of wall thinning defect that is artificially processed inside the carbon steel pipe by using IRT are obtained.

  • PDF

Siamese Neural Networks to Overcome the Insufficient Data Problems in Product Defect Detection (제품 결함 탐지에서 데이터 부족 문제를 극복하기 위한 샴 신경망의 활용)

  • Shin, Kang-hyeon;Jin, Kyo-hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.108-111
    • /
    • 2022
  • Applying deep learning to machine vision systems for defect detection of products requires vast amounts of training data about various defect cases. However, since data imbalance occurs according to the type of defect in the actual manufacturing industry, it takes a lot of time to collect product images enough to generalize defect cases. In this paper, we apply a Siamese neural network that can be learned with even a small amount of data to product defect detection, and modify the image pairing method and contrastive loss function by properties the situation of product defect image data. We indirectly evaluated the embedding performance of Siamese neural networks using AUC-ROC, and it showed good performance when the images only paired among same products, not paired among defective products, and learned with exponential contrastive loss.

  • PDF

Phonosurgery after Laser Cordectomy (레이저 성문절제술 후의 음성수술)

  • So, Yoon-Kyung;Son, Young-Ik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • Endoscopic laser cordectomy is known as an oncologically sound procedure for T1 and selected T2 glottic carcinoma ; it has comparable local control rate and better long-term laryngeal preservation rate when compared with those of radiotherapy. Even if results of the reported voice outcome studies after surgery or radiotherapy are diverse and controversial, resection deeper than the body layer of the vocal fold (type III, IV, V cordectomy) usually leads to aerodynamic insufficiency during phonation and results in poor voice quality. A keyhole defect or development of synechiae at the anterior commissure after type VI cordecomy may also result in unsatisfactory vocal outcome. However, many advances in phonosurgical techniques are reported to be successfully applied in the reconstruction of glottal defect that is subsequent to endoscopic laser cordectomy. In case of glottal insufficiency, voice restoration can be achieved by means of augmentation of the paraglottic space or medialization of the excavated vocal fold. Injection laryngoplasty with synthetic materials or autologous fat is gaining its popularity for restoring minor glottal volume defect because of its convenience. Laryngeal framework surgery, especially type I thyroplasty with premade implant systems or Gore-Tex, is most frequently used to correct larger glottic volume defect. In case of anterior commissural keyhole defect, additional procedure including laryngofissure may be required. For anterior commissural synechiae, laryngeal keel may be inserted for several weeks or mitomycin-C may be repeatedly applied after the division of adhesive scar to prevent restenosis. In this paper, current concepts and the authors' experiences of phonosurgical reconstruction of vocal function after endoscopic cordectomy will be introduced.

  • PDF

Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers (몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작)

  • Lee, Gyeong-Yeol;Kim, Sung-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

Effect of Heat Input Rate on the Weld Defect Formation during High Frequency Electric Resistance Welding (고주파 전기 저항 용접부의 용접 결함 발생 빈도에 미치는 용접 입열 속도의 영향)

  • 조윤희;김충명;김용석
    • Proceedings of the KWS Conference
    • /
    • 2000.10a
    • /
    • pp.201-203
    • /
    • 2000
  • In this study, effect of welding parameters on the defect density in the weldments produced by high frequency electric resistance welding process. The defect density measured by X-ray radiography showed a W-type curve as a function of heat input rate. The mechanisms of the such behavior were discussed based on the chemical compositions of the oxides formed at the weldments.

  • PDF

Self-Inspection for Photomask Defect Extraction (자체 검사를 이용한 포토마스크 결점 추출)

  • Choi, Ji-Hee;Jeong, Hong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.933-934
    • /
    • 2008
  • This paper describes the process of extracting defect from optical photomask images. We introduce a new method of finding photomask detects with a single optical photomask damaged image. The proposed algorithm is efficient when an original undamaged image is unavailable. The experiment showed that even a small and discontinuous photomask defect was extracted as well as continuous type of defects.

  • PDF

Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires (전기장판 열선 결함에 의한 전기화재 원인분석)

  • Song, J.Y.;Sa, S.H.;Nam, J.W.;Kim, J.P.;Cho, Y.J.;Oh, B.Y.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

A Study on Wettability and Defects Behavior of Flow-soldered Joint using Low Residue Flux (저잔사 플럭스를 사용한 플로우 솔더링부의 젖음성 및 결함거동에 관한 연구)

  • 최명기;이창열;정재필;서창제;신영의
    • Journal of Welding and Joining
    • /
    • v.16 no.6
    • /
    • pp.77-85
    • /
    • 1998
  • Effects of non-cleaning and cleaning fluxes on the wetting properties and defects at flow soldered joints were investigated. Non-cleaning flux (R-type of 3.3% solid content) and cleaning flux (RMA-type of 15% solid content) were used. Wetting test was accomplished by wetting balance method with changing surface state of wetting specimen, CU. Sn-37%Pb solder was used for wetting test and flow soldering. As experimental results, the wetting time for vertical force from the surface tension being zero was mainly affected by surface state of the wetting specimen. Non-cleaning flux had a good wettability compared with cleaning flux. In case of non-cleaning flux, conveyor speed had a great affection to defects of bridge, icicle, and poor solder.

  • PDF