• Title/Summary/Keyword: defect type

Search Result 1,069, Processing Time 0.034 seconds

Study on the implementation of malfunction, defect and failure reporting system to the korean indigenous aircraft (국내 개발 항공기에 대한 항공안전 고장보고 제도운용에 대한 고찰)

  • Park, Guen-Young;Yoo, Seung Woo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2016
  • ROK issued its first type certificate to the KC-100 airplane, Part 23 normal category, and become the State of Design (SoD) in 2013. Before this, ROK aviation regulations were focused on the operation and continued airworthiness of aircraft registered and operated in ROK that were designed and manufactured in another contracting state. Therefore the implementation of reporting system were restricted to gather the failure and service difficulty reports from the owners or operators and transmit the information to the State of Design and/or the manufacture relating to the type certificated aircraft. However, ROK, to fulfill the accountability of the State of Design, has to ensure there is a system to address the information received from the State of Registry on failure, malfunctions, defects and other occurrences that might cause adverse effects on the continuing airworthiness of the korean type certificated aircraft. This paper presents an overview of ICAO requirements for the State of Design, and current implementation of reporting system of USA and Japan and discusses the current status and further considerations on the rule-making for the malfunction, defect and failure reporting system applicable to the korean indigenous aircraft.

A Study on Improvement of Slurry Filter Efficiency in the CMP Process (CMP 공정에서 슬러리 필터의 효율 개선에 관한 연구)

  • Park, Sung-Woo;Seo, Yong-Jin;Seo, Sang-Yong;Lee, Woo-Sun;Kim, Chang-Il;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.34-37
    • /
    • 2001
  • As the integrated circuit device shrinks to smaller dimensions, chemical mechanical polishing (CMP) process was required for the global planarization of inter-metal dielectric (IMD) layer with free-defect. However, as the inter-metal dielectrics (IMD) layer gets thinner, micro-scratches are becoming as major defects. Micro-scratches are generated by agglomerated slurry, solidified and attached slurry in pipe line of slurry supply system. To prevent agglomerated slurry particle from inflow, we installed 0.5${\mu}m$ POU (point of use) filter, which is depth-type filter and has 80% filtering efficiency for the $1.0{\mu}m$ size particle. In this paper, we studied the relationship between defect generation and pad count to understand the exact efficiency of the slurry filtration, and to find out the appropriate pad usage. Our preliminary results showed that it is impossible to prevent defect-causing particles perfectly through the depth-type filter. Thus, we suggest that it is necessary to optimize the flow rate of slurry to overcome depth type filters weak-point, and to install the high spray of de-ionized Water (DIW) with high pressure.

  • PDF

Structural Integrity Evaluation of SG Tube with Surface Wear-type Defects (표면 마모결함을 고려한 증기발생기 세관의 구조건전성 평가)

  • Kim, Jong-Min;Huh, Nam-Su;Chang, Yoon-Suk;Hwang, Seong-Sik;Kim, Joung-Soo;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1618-1625
    • /
    • 2006
  • During the last two decades, several guidelines have been developed and used for assessing the integrity of a defective steam generator (SG) tube that is generally caused by stress corrosion cracking or wall-thinning phenomenon. However, as some of SG tubes are also failed due to fretting and so on, alternative failure estimation schemes are required for relevant defects. In this paper, parametric three-dimensional finite element (FE) analyses are carried out under internal pressure condition to simulate the failure behavior of SG tubes with different defect configurations; elliptical wear, tapered and flat wear type defects. Maximum pressures based on material strengths are obtained from more than a hundred FE results to predict the failure of SG tube. After investigating the effect of key parameters such as defect depth, defect length and wrap angle, simplified failure estimation equations are proposed in relation to the equivalent stress at the deepest point in wear region. Comparison of failure pressures predicted by the proposed estimation scheme with corresponding burst test data showed a good agreement.

Improvement of Pad Lifetime using POU (Point of Use) Slurry Filter and High Spray Method of De-Ionized Water (POU 슬러리 필터와 탈이온수의 고분사법에 의한 패드수명의 개선)

  • 박성우;김상용;서용진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.707-713
    • /
    • 2001
  • As the integrated circuit device shrinks to smaller dimensions, chemical mechanical polishing (CMP) process was requirdfo the global planarization of inter-metal dielectric (IMD) layer with free-defect. However, as the IMD layer gest thinner, micro-scratches are becoming as major defects. However, as the IMD layer gets thinner, micro-scratches are becoming as major defects. Micro-scratches are generated by agglomerated slurry, solidified and attached slurry in pipe line of slurry supply system. To prevent agglomerated slurry particle from inflow, we installed 0.5${\mu}{\textrm}{m}$ point of use (POU) filter, which is depth-type filter and has 80% filtering efficiency for the 1.0${\mu}{\textrm}{m}$ size particle. In this paper, we studied the relationship between defect generation and polished wafer counts to understand the exact efficiency fo the slurry filteration, and to find out the appropriate pad usage. Our experimental results showed that it sis impossible to prevent defect-causing particles perfectly through the depth-type filter. Thus, we suggest that it is necessary to optimize the slurry flow rate, and to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of depth type filter.

  • PDF

Bronchial Artery Embolization of Massive Hemoptysis -2 cases- (대량 객혈에 대한 기관지동맥 색전술 -치험 2례-)

  • 강경훈
    • Journal of Chest Surgery
    • /
    • v.21 no.6
    • /
    • pp.1117-1123
    • /
    • 1988
  • Prolapse of the aortic valve is the main cause of insufficiency of the aortic valve as a complication of ventricular septal defect. Aortic insufficiency gets worse by the progress of prolapse of aortic valve due to lack of support of the valve and the hemodynamic effect of blood flow through the ventricular septal defect. This produces typical clinical picture, that may be serious and threatening when it is untreated. Type and timing for the surgical treatment of the ventricular septal defect with aortic insufficiency is considered. Among 113 ventricular septal defect, 9 patients of ventricular septal defect with associated aortic insufficiency were experienced from June. 1983 to June 1988 at the Department of Thoracic and Cardiovascular Surgery, Chon-Buk University Hospital. Male was 6 patients and female was 3 patients. Ages were from 7 years to 24years. 5 patients were from 10 to 19 years age. 3 patients were below 10 years age. The ratio of pulmonary blood flow to systemic f low [Qp/Qs] was 1.53 and in pulmonary vascular resistance, normal or slight increase was 7 patients, moderate 1 patient, and severe 1 patient. Ventricular septal defect was subpulmonic in 5 patients and infracristal in 4 patients. Prolapse of right coronary cusp was 7 patients, right and non coronary cusp 1 patient and non coronary cusp 1 patient. Teflon patch closure of ventricular septal defect was undertaken in 3 patients and primary closure in 1 patient. Among the 4 patients of defect closure alone, one patient performed valve replacement 7 months later due to progressive regurgitation and cardiac failure and the result was good. The other 3 patients were good result. Closure of ventricular septal defect and aortic valvuloplasty performed in 4 patients. 2 patients of these required valve replacement for the sudden intractable cardiac failure and died due to low cardiac output. The cause of intractable cardiac failure was tearing of repaired valve at the fixed site. The other 2 patients were good result. Closure of ventricular septal defect and valve replacement performed in 1 patient with good result.

  • PDF

A Case of Atrial Septal Defect (ASD) in a Miniature Schunauzer Dog (Miniature Schunauzer Dog에서 발생한 심방중격 결손 증례)

  • Park, Chul;Choi, Chi-bong;Kim, Il-hwan;Park, Hee-myung
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.2
    • /
    • pp.307-310
    • /
    • 2003
  • An atrial septal defect (ASD) is congenital heart disease with a communication between the atria, which allows blood to shoot from the atrium with pressure. A 3-month-old female Miniature Schunauzer was referred to the Veterinary Teaching Hospital of Konkuk University for the evaluation of systolic heart murmur. At presentation, the mucous membrane was cyanotic. On physical examination, an ejection-type systolic murmur was auscultated at the pulmonic area. In addition, thoracic radiography showed enlargement of main pulmonary artery and right atrial/ventricular enlargement. Echocardiography revealed dilated right atrium and atrial septal defect. However, mitral and tricuspid valve were still intact and well tolerating. The presence of an ASD was confirmed by identifying flow across the defect with color Doppler imaging. Doppler echocardiography provides a means of non-invasive documentation and quantification of ASD. Complete blood count and serum chemistry were not remarkable. Although large defect was confirmed between the two atrium, the patient did not show any obvious clinical signs of heart failure at this time.

Clinical Evaluation of Atrial Septal Defect (심방중격결손증의 임상적 고찰)

  • 장동철
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.106-111
    • /
    • 1987
  • Twenty eight patients with atrial septal defect operated on from May, 1983, to July, 1986 at the Department of Thoracic and Cardiovascular Surgery, Chungnam National University Hospital, were analyzed retrospectively. Among the 28 patients of atrial septal defect, 8 were male and 20 were female. Their ages ranged from 4.6 years to 52.5 years old with the mean of 15.3 years. The main clinical symptoms on admission were exertional dyspnea [82%], frequent respiratory infection [75%], palpitation [54%] and easy fatigability [25%]. Electrocardiographic findings were as follows: Regular sinus rhythm [100%], RVH [54%], RBBB [25%] and first degree of A-V block [4%]. Hemodynamic studies were performed in all cases and mean pulmonary systolic arterial pressure was 34.1*11.8mmHg. and mean Qp/Qs was 2.6*0.9. All 28 patients were operated under direct vision using extracorporeal circulation. 23 cases were secundum type defect and a single hole was found in 22 cases. The associated cardiovascular anomalies were found in 11 patients: ventricular septal defect in 3, patent ductus arteriosus in 1, partial anomalous pulmonary venous drainage in 2, mitral regurgitation in 2, tricuspid regurgitation in 1, anomalous left atrial septation in 1 and valvular pulmonary stenosis in 1. The defect closed directly in 22 cases and with patches in 6 cases. Postoperative complications were wound infection, arrhythmia bleeding, intracardiac patch detachment, pneumothorax and urethral injury. But there was no operative mortality.

  • PDF

Defect Detection of Wall Thinned Straight Pipe using Shearography and Lock-in Infrared Thermography (전단간섭계와 적외선열화상을 이용한 감육 직관의 결함검출)

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Chang, Ho-Seob;Kim, Ha-Sig;La, Sung-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.55-61
    • /
    • 2009
  • The wall thinning defect of nuclear power pipe is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid. This type of defect becomes the cause of damage or destruction of in carbon steel pipes. Therefore, it is very important to measure defect which is existed not only on the welding part but also on the whole field of pipe. This study use dual-beam Shearography, which can measure the out-of-plane deformation and the in-plane deformation by using another illuminated laser beam and simple image processing technique. And this study proposes Infrared thermography, which is a two-dimensional non-contact nondestructive evaluation that can detect internal defects from the thermal distribution by the inspection of infrared light radiated from the object surface. In this paper, defect of nuclear power pipe were, measured using dual-beam shearography and infrared thermography, quantitatively evaluated by the analysis of phase map and thermal image pattern.

Study on the Improvement Plans of Condensation Defect Examples in Apartment Building (공동주택 결로 하자 사례를 통한 개선방안 도출)

  • Oh, Se Min;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • There are main issues of defect type that condensation, concrete crack and noise in apartment buildings. Especially, according to the Apartment Defect Dispute Mediation Committee in Korea (ADDMC) at Ministry of Land Infrastructure and Transport in Korea (MLIT), condensation defects are great importance (14 percent) on whole number of reported cases of faults from 2015 in Korea. Most condensation defects have many different causes that take a toll on the resident's life and space. So it is very important to early detection and repair. For preventing the condensation in apartment buildings, there are building codes in Korea such as 'Standard of Method and Judgment for Apartment defect of investigation, Repair cost Estimate'. This research aims to study on the improvement of preventing the condensation aforementioned korea standard. Types and characteristics (opaque wall, windows, doors) of cause of occurrence and existing state condensation defect is analyzed from evaluation of real application 100 case in 2015 ADDMC data.

The Defect Detection and Evaluation of Austenitic Stainless Steel 304 Weld Zone using Ultrasonic Wave and Neuro (초음파와 신경망을 이용한 오스테나이트계 스테인리스강 304 용접부의 결함 검출 및 평가)

  • Yi, Won;Yun, In-Sik
    • Journal of Welding and Joining
    • /
    • v.16 no.3
    • /
    • pp.64-73
    • /
    • 1998
  • This paper is concerned with defects detection and evaluation of heat affected zone (HAZ) in austenitic stainless steel type 304 by ultrasonic wave and neural network. In experiment, the reflected ultrasonic defect signals from artificial defects (side hole, vertical hole, notch) of HAZ appears as beam distance of prove-defect, distance of probe-surface, depth of defect-surface on CRT. For defect classification simulation, neural network system was organized using total results of ultrasonic experiment. The organized neural network system was learned with the accuracy of 99%. Also it could be classified with the accuracy of 80% in side hole, and 100% in vertical hole, 90% in notch about ultrasonic pattern recognition. Simulation results of neural network agree fairly well with results of ultrasonic experiment. Thus were think that the constructed system (ultrasonic wave - neural network) in this work is useful for defects dection and classification such as holes and notches in HAZ of austenitic stainless steel 304.

  • PDF