• 제목/요약/키워드: defect type

검색결과 1,069건 처리시간 0.036초

대동맥 결손증 (Type A) 의 외과적 치험 (Surgical Repair of Interruption of the Aortic Arch[Type A] -A Report of 5 Cases-)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.665-671
    • /
    • 1988
  • Between 1981 and 1987, five patients with an interruption of the aortic arch were operated upon. All had a ventricular septal defect and a patent ductus arteriosus as associated anomalies. A two-stage procedure was employed in these cases, the initial procedure being repair of the interrupted arch, ligation of the patent ductus arteriosus, banding of the main pulmonary artery and a lung biopsy which was followed, 5 to 49 months later, by the repair of the ventricular septal defect. Four patients completed the two-stage procedure with one postoperative mortality. The remaining patient is yet to complete the second stage procedure.

  • PDF

Closure of meningomyelocele defects using various types of keystone-design perforator island flaps

  • Putri, Nandita Melati;Tunjung, Narottama;Sadikin, Patricia Marcellina
    • Archives of Plastic Surgery
    • /
    • 제48권3호
    • /
    • pp.261-268
    • /
    • 2021
  • Background Various methods have been described to close large meningomyelocele defects, but no technique has been proven superior to others. This study presents cases of meningomyelocele defect closure with a keystone-design perforator island flap. Methods A retrospective study was performed on 14 patients with meningomyelocele defects closed using various types of keystone flaps. Results The median age of the patients at surgery was 10.5 days (range, 1-369 days) and the average defect size was 22.5 cm2 (range, 7.1-55.0 cm2). The average operative time for defect closure was 89.6 minutes (range, 45-120 minutes). Type IV bilateral keystone flaps were used for four defects, type IV unilateral flaps for six defects, type IIA flaps for two defects, and type III flaps for two defects. Conclusions All the defects healed completely with no major complications. The keystone-design perforator island flap is a reliable, easy, and fast technique to close large meningomyelocele defects.

위상잠금 광-적외선 열화상 기술을 이용한 감육결함이 있는 직관시험편의 결함 검출 (Defect detection of wall thinning defect in pipes using Lock-in photo-infrared thermography technique)

  • 김경석;장수옥;박종현;;송재근;정현철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.317-321
    • /
    • 2008
  • Piping in the Nuclear Power plants (NPP) are mostly consisted of carbon steel pipe. The wall thinning defect is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid which flows in carbon steel pipes. This type of defect becomes the cause of damage or destruction of piping. Therefore, it is very important to measure defect which is existed not only on the welding partbut also on the whole field of pipe. Over the years, Infrared thermography (IRT) has been used as a non destructive testing methods of the various kinds of materials. This technique has many merits and applied to the industrial field but has limitation to the materials. Therefore, this method was combined with lock-in technique. So IRT detection resolution has been progressively improved using lock-in technique. In this paper, the quantitative analysis results of the location and the size of wall thinning defect that is artificially processed inside the carbon steel pipe by using IRT are obtained.

  • PDF

제품 결함 탐지에서 데이터 부족 문제를 극복하기 위한 샴 신경망의 활용 (Siamese Neural Networks to Overcome the Insufficient Data Problems in Product Defect Detection)

  • 신강현;진교홍
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.108-111
    • /
    • 2022
  • 제품의 결함 탐지를 위한 머신 비전 시스템에 딥러닝을 적용하기 위해서는 다양한 결함 사례에 대한 방대한 학습 데이터가 필요하다. 하지만 실제 제조 산업에서는 결함의 종류에 따른 데이터 불균형이 생기기 때문에 결함 사례를 일반화할 수 있을 만큼의 제품 이미지를 수집하기 위해서는 많은 시간이 소요된다. 본 논문에서는 적은 데이터로도 학습이 가능한 샴 신경망을 제품 결함 탐지에 적용하고, 제품 결함 이미지 데이터의 속성을 고려하여 이미지 쌍 구성법과 대조 손실 함수를 수정하였다. AUC-ROC로 샴 신경망의 임베딩 성능을 간접적으로 확인한 결과, 같은 제품끼리만 쌍을 구성하고 결함이 있는 제품 간에는 쌍을 구성하였을 때, 그리고 지수 대조 손실로 학습하였을 때 좋은 임베딩 성능을 보였다.

  • PDF

레이저 성문절제술 후의 음성수술 (Phonosurgery after Laser Cordectomy)

  • 소윤경;손영익
    • 대한후두음성언어의학회지
    • /
    • 제19권1호
    • /
    • pp.11-15
    • /
    • 2008
  • Endoscopic laser cordectomy is known as an oncologically sound procedure for T1 and selected T2 glottic carcinoma ; it has comparable local control rate and better long-term laryngeal preservation rate when compared with those of radiotherapy. Even if results of the reported voice outcome studies after surgery or radiotherapy are diverse and controversial, resection deeper than the body layer of the vocal fold (type III, IV, V cordectomy) usually leads to aerodynamic insufficiency during phonation and results in poor voice quality. A keyhole defect or development of synechiae at the anterior commissure after type VI cordecomy may also result in unsatisfactory vocal outcome. However, many advances in phonosurgical techniques are reported to be successfully applied in the reconstruction of glottal defect that is subsequent to endoscopic laser cordectomy. In case of glottal insufficiency, voice restoration can be achieved by means of augmentation of the paraglottic space or medialization of the excavated vocal fold. Injection laryngoplasty with synthetic materials or autologous fat is gaining its popularity for restoring minor glottal volume defect because of its convenience. Laryngeal framework surgery, especially type I thyroplasty with premade implant systems or Gore-Tex, is most frequently used to correct larger glottic volume defect. In case of anterior commissural keyhole defect, additional procedure including laryngofissure may be required. For anterior commissural synechiae, laryngeal keel may be inserted for several weeks or mitomycin-C may be repeatedly applied after the division of adhesive scar to prevent restenosis. In this paper, current concepts and the authors' experiences of phonosurgical reconstruction of vocal function after endoscopic cordectomy will be introduced.

  • PDF

몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작 (Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers)

  • 이경렬;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

고주파 전기 저항 용접부의 용접 결함 발생 빈도에 미치는 용접 입열 속도의 영향 (Effect of Heat Input Rate on the Weld Defect Formation during High Frequency Electric Resistance Welding)

  • 조윤희;김충명;김용석
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2000년도 특별강연 및 추계학술발표대회 개요집
    • /
    • pp.201-203
    • /
    • 2000
  • In this study, effect of welding parameters on the defect density in the weldments produced by high frequency electric resistance welding process. The defect density measured by X-ray radiography showed a W-type curve as a function of heat input rate. The mechanisms of the such behavior were discussed based on the chemical compositions of the oxides formed at the weldments.

  • PDF

자체 검사를 이용한 포토마스크 결점 추출 (Self-Inspection for Photomask Defect Extraction)

  • 최지희;정홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.933-934
    • /
    • 2008
  • This paper describes the process of extracting defect from optical photomask images. We introduce a new method of finding photomask detects with a single optical photomask damaged image. The proposed algorithm is efficient when an original undamaged image is unavailable. The experiment showed that even a small and discontinuous photomask defect was extracted as well as continuous type of defects.

  • PDF

전기장판 열선 결함에 의한 전기화재 원인분석 (Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires)

  • 송재용;사승훈;남정우;김진표;조영진;오부열
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

저잔사 플럭스를 사용한 플로우 솔더링부의 젖음성 및 결함거동에 관한 연구 (A Study on Wettability and Defects Behavior of Flow-soldered Joint using Low Residue Flux)

  • 최명기;이창열;정재필;서창제;신영의
    • Journal of Welding and Joining
    • /
    • 제16권6호
    • /
    • pp.77-85
    • /
    • 1998
  • Effects of non-cleaning and cleaning fluxes on the wetting properties and defects at flow soldered joints were investigated. Non-cleaning flux (R-type of 3.3% solid content) and cleaning flux (RMA-type of 15% solid content) were used. Wetting test was accomplished by wetting balance method with changing surface state of wetting specimen, CU. Sn-37%Pb solder was used for wetting test and flow soldering. As experimental results, the wetting time for vertical force from the surface tension being zero was mainly affected by surface state of the wetting specimen. Non-cleaning flux had a good wettability compared with cleaning flux. In case of non-cleaning flux, conveyor speed had a great affection to defects of bridge, icicle, and poor solder.

  • PDF