• 제목/요약/키워드: decay detection

Search Result 65, Processing Time 0.028 seconds

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

The Improved Method for Precise Determination of Pu Isotope Ratio using MC-ICP-MS (다중검출기유도결합플라즈마질량분석기를 이용한 Pu 동위원소비 정밀 분석법)

  • Yim, Seong-A;Han, Eun-Mi;Chae, Jung-Seok;Yun, Ju-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.117-123
    • /
    • 2010
  • Plutonium is by far the most important of the transuranic elements which have been released into the environment due to radio-toxicity and long term radiation effects on humans. And Pu isotope ratio ($^{240}Pu/^{239}Pu$) is of great interest because this ratio is used as a fingerprint for different sources. Mass spectrometry has been used as an useful atom counting technique with several advantages over decay counting techniques for the determination of Pu isotopes. It enables a determination of Pu isotope ratio in the environmental samples with a low detection limit and a short determination time. An ICP-MS is the representative mass spectrometry for Pu determination. In this study, the precision of $^{240}Pu/^{239}Pu$ isotope ratio was improved by using 4 multiple ion counters of MC-ICP-MS. The detection limit of $^{239}Pu$ and $^{240}Pu$ were $0.10\;fg\;ml^{-1}$ ($0.24\;{\mu}Bq\;ml^{-1}$), $0.12\;fg\;ml^{-1}$ ($0.97\;{\mu}Bq\;ml^{-1}$), respectively. The relative standard deviation of $^{240}Pu/^{239}Pu$ isotope ratio was less than 1 % in trace level. The various reference materials (seawater, soil and sediment) were analyzed to verify this method and their analytical results were in good agreement with the certified (or recommended value) value.

UHF Sensor Location Optimization for Partial Discharge Signals Detection Method (UHF 센서 위치 최적화로 부분방전 신호 검출 방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.409-413
    • /
    • 2014
  • GIS partial discharge that occurred in the UHF band signal is effectively detected by the method to IEC60270 5pc the apparent minimum discharge can be detected over the GIS arrangement of the sensor interior and exterior of the UHF in accordance with the optimized position signal by considering the damping ratio is selected so that the signals can be obtained to be mounted. 362kV, 800kV GIS is installed on the internal and external sensors are UHF band signal attenuation is set by measuring the reference value, but the operation, 170kV case 362kV, 800kV on the basis of the measurement data and to be installed and operated. When 170kV per 1Bay by installing the built-in sensor 1 for detecting a partial discharge signal, But, GIS signal attenuation is large in the case of an internal partial discharge signal is not detected in some cases. Where the attenuation is great UHF signal of the sensor by increasing the quantity of partial discharge signals were acquired to allow relocation. The greater the spacing between the sensor and the sensor is applied simplifies the installation and reduces the cost in terms of maintenance of appropriate optimal position is calculated to detect the partial discharge signal is needed. Thus 170kV GIS signal power attenuation of a partial discharge by measuring the UHF sensor, and by relocating the proper position is calculated in accordance with the sensor signal decay rate and minimize the error of omission in detecting a partial discharge signal was optimized.

Measurement of Gamma ray Spectrum for the 27Al(p,3p+n)24Na Nuclear Reaction by using 100 MeV Proton Acceleration System (100 MeV 양성자가속기를 이용한 27Al(p,3p+n)24Na 핵반응에 대한 감마선 스펙트럼 측정)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.55-59
    • /
    • 2015
  • Research about the proton nuclear reaction is actively achieving on the proton therapy including material development of fusion reactor. The proton induced gamma ray energy(2754, 1386 keV) spectrum of 27Al(p,3p+n)24Na reaction was measured with 100 MeV high energy proton beam. The proton beam in the experiment was derived from 100 MeV proton linear accelerator in the KOMAC. We measured the gamma ray intensity ratio of the decay level from the energy spectrum. The previous results have been compared with the current result. Strength of measured gamma rays will provide very important information though decide high energy gamma radiation detection efficiency.

A Comparative Study on the Determination of the Selenium in Biological Samples using 75Se and 77mSe Nuclides (75Se과 77mSe 핵종을 이용한 생물시료 중의 셀렌 분석에 대한 비교 연구)

  • Moon, Jong-Hwa;Kang, Sang-Hoon;Kim, Sun-Ha;Chung, Yong-Sam;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.23-26
    • /
    • 2005
  • Se is well known as an anti-oxidant trace element and many customers are interested in an analysis and contents of Se in the various foodstuff samples. This study was aimed at establishig and comparing an analytical method for the determination of the Se in biological samples by neutron activation analysis using two nuclides, $^{75}Se$ and $^{77m}Se$. Keeping this objective, three NIST biological standard reference materials were chosen and the concentrations of the Se were determined under the prefixed analytical conditions such as the irradiation, decay and measurement time. The measured values by both analytical methods were evaluated with certified values. In addition, the detection limits and measurement uncertainty for the analytical results using $^{75}Se$ and $^{77m}Se$ were compared with each other.

Development of Parallel Plate Avalanche Counter for heavy ion collision in radioactive ion beam

  • Wei, Xianglun;Guan, Fenhai;Yang, Herun;Wang, Yijie;Zhang, Junwei;Ma, Peng;Diao, Xinyue;Lu, Chengui;Li, Meng;Guan, Yuanfan;Duan, Limin;Hu, Rongjiang;Zhang, Xiuling;Xiao, Zhigang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.575-580
    • /
    • 2020
  • We have developed a position-sensitive Parallel Plate Avalanche Counter (PPAC) to detect the fission fragments and reconstruct the fission reaction plane in the experiment of studying nuclear equation of state (nEOS) by means of heavy ion collision (HIC). This experiment put forward high requirements for the performances of PPAC, such as the time resolution, efficiency and position resolution. According to these requirements we designed the PPAC with an active area of 240 mm × 280 mm working at low gas pressure. The results show that time resolution could be less than 300 ps. Position resolution is consistent with the theoretical calculation about 1.35 mm. Detection efficiency could be approaching 100% gradually with the voltage increasing in different gas pressures. The performances of PPAC have also been verified in beam experiment. Each set of anode wires can be accurately separated in the position spectrum. In the beam experiment, we also got the back-to-back correlation of fission fragments which is one of the direct signals characterizing binary decay.

Study on Soot Primary Particle Size Measurement in Ethylene Diffusion Flame by Time-Resolved Laser-Induced Incandescence (시분해 레이저 유도 백열법을 이용한 에틸렌 확산 화염에서의 매연 일차입자크기 측정에 관한 연구)

  • Kim Gyu-Bo;Cho Seung-Wan;Lee Jong-Ho;Jeong Dong-Soo;Chang Young-June;Jeon Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.973-981
    • /
    • 2006
  • Recently there is an increasing interest in particulate matter emission because of new emission regulations, health awareness and environmental problems. It requires to improve particulate measurement techniques as well as to reduce soot emissions from combustion systems. As mentioned above, it is demanded that reduction techniques together with measurement techniques of exhausted particulate matters in combustion systems such as vehicles. However, measurement techniques of particulate matters should be prior to reduction techniques of that because it is able to know an increase and a decrease of exhausted particulate matters when measured particulate matters. Therefore, in this study, we report the measurement of soot primary-particle size using time-resolved laser induced incandescence (TIRE-LII) technique in laminar ethylene diffusion flame. As an optical method, laser induced incandescence is one of well known methods to get information for spatial and temporal soot volume fraction and soot primary particle size. Furthermore, TIRE-LII is able to measure soot primary particle size that is decided to solve the decay ate of signal S $(t_1)$ and S $(t_2)$ at two detection time. In laminar ethylene diffusion flame, visual flame height is 40 mm from burner tip and measurement points are height of 15, 20, 27.5, 30 mm above burner tip along radial direction. As increasing the height of the flame from burne. tip, primary particle size was increased to HAB(Height Above Burner tip)=20mm, and then decreased from HAB=27.5 mm to 30 mm. This results show the growth and oxidation processes for soot particles formed by combustion.

RADIOPACITY OF DENTAL GLASS POLYALKENOATE CEMENTS (치과용 Glass Polyalkenoate cement의 방사선 불투과성에 관한 비교 연구)

  • Rim, Young-Il;Um, Chung-Moon;Lee, Chung-Sik;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.464-469
    • /
    • 1997
  • The radiopacity of glass ionomer cements is quite variable. The use of a poorly radiopaque material as a base under other restorative materials can mislead the dentist to a diagnosis of recurrent decay. This study investigates the radiopacity of these materials and proposes a minimal radiopacity under which a material should not be used as a base or liner. It is important to determine the radiopacity of glass ionomer dental materials so that the clinician can appreciate the type of restorative materials used when radiographically evaluation the possibility of recurrent dental caries. In this study, radiopacity of Vitrement and Chemfil was compared with that of Cavalite, Miracle mix and polycarboxylate cement. Tooth model of artificial cavity preparation for diagnosis of recurrent caries was omitted. Radiopacity of each material was measured using relatives between thickness and radiopacity of Aluminium step wedge. The results were as follows : 1. Radiopacity of Vitrement was some higher than enamel. 2. Chemfil, restorative glass ionomer, was less radiopaque than enamel. 3. In order of higher radiopacity than enamel, Miracle mix was highest and was followed by polycarboxylate cement, Cavalite and Vitremer. 4. Vitremer, the Glass Ionomer Cement, is useful to detection of recurrent caries, because it is slightly higher radiopaque than enamel. So, it is suitable for restorative material and luting cement.

  • PDF

Detection of Antibody to Infectious Laryngotracheitis Virus by Enzyme Linked Immunosorbent Assay (효소면역법에 의한 닭 전염성 후두기관염 바이러스 항체 측정에 관한 연구)

  • 임숙경;위성하;최정옥;고홍남
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.1
    • /
    • pp.32-45
    • /
    • 1992
  • In order to establish and enzyme-linked immunosorbent assay to ILTV, field virus strain of ILTV was propagated in chorioallantoic membrane of the embryonated eggs. purified and used as antigen. The antisera selected from the field samples and immunized chickens based on serum neutralization test were used as the standard positive and negative sera in all tests. It was found that optimal antigen concentration was $2{\mu}g$ of protein per well and a 1 : 100 dilution of standard serum showed low background optical density with negative serum and high P/N values of positive sera. A 1 : 500 dilution of the rabbit anti-chicken IgG peroxidase conjugate produced a high P/N values and thirty minutes was chosen as suitable time to read the optical density of the enzyme substrate reaction and optical density was consistent during the 16 hours after stopper was treated. When coated antigen was kept on microplate for varying time up to 16 hours at $4^{\circ}C$ or $37^{\circ}C,$ no significant difference was observed between the treatment. The coated antigen could be kept without change of antigenicity for at least one month at $-70^{\circ}C,\; -20^{\circ}C,\; 4^{\circ}C$ and room temperature. When blocking buffer contanining bovine serum albumin was mixed directly with conjugate and serum at 10% level induced higher P/N values compared to blocking antigen coated microplate with the same blocking buffer. The coefficience of correlation between ELISA and SN test was 0.577. When antibody response of chickens, vaccinated with ILTV, was examined by ELISA and SN test, antibody rising and decay pattern between the two test was similar until 11 weeks of age. However 12 weeks onward antibody titer checked on by SN test was slightly lower than that tested by ELISA.

  • PDF

Performance-based and damage assessment of SFRP retrofitted multi-storey timber buildings

  • Vahedian, Abbas;Mahini, Seyed Saeed;Glencross-Grant, Rex
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.3
    • /
    • pp.269-282
    • /
    • 2015
  • Civil structures should be designed with the lowest cost and longest lifetime possible and without service failure. The efficient and sustainable use of materials in building design and construction has always been at the forefront for civil engineers and environmentalists. Timber is one of the best contenders for these purposes particularly in terms of aesthetics; fire protection; strength-to-weight ratio; acoustic properties and seismic resistance. In recent years, timber has been used in commercial and taller buildings due to these significant advantages. It should be noted that, since the launch of the modern building standards and codes, a number of different structural systems have been developed to stabilise steel or concrete multistorey buildings, however, structural analysis of high-rise and multi-storey timber frame buildings subjected to lateral loads has not yet been fully understood. Additionally, timber degradation can occur as a result of biological decay of the elements and overloading that can result in structural damage. In such structures, the deficient members and joints require strengthening in order to satisfy new code requirements; determine acceptable level of safety; and avoid brittle failure following earthquake actions. This paper investigates performance assessment and damage assessment of older multi-storey timber buildings. One approach is to retrofit the beams in order to increase the ductility of the frame. Experimental studies indicate that Sprayed Fibre Reinforced Polymer (SFRP) repairing/retrofitting not only updates the integrity of the joint, but also increases its strength; stiffness; and ductility in such a way that the joint remains elastic. Non-linear finite element analysis ('pushover') is carried out to study the behaviour of the structure subjected to simulated gravity and lateral loads. A new global index is re-assessed for damage assessment of the plain and SFRP-retrofitted frames using capacity curves obtained from pushover analysis. This study shows that the proposed method is suitable for structural damage assessment of aged timber buildings. Also SFRP retrofitting can potentially improve the performance and load carrying capacity of the structure.