• Title/Summary/Keyword: dead

Search Result 3,297, Processing Time 0.034 seconds

An Efficient Dead Pixel Detection Algorithm and VLSI Implementation (효율적인 불량화소 검출 알고리듬 및 하드웨어 구현)

  • An Jee-Hoon;Lee Won-Jae;Kim Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.9 s.351
    • /
    • pp.38-43
    • /
    • 2006
  • In this paper, we propose the efficient dead pixel detection algorithm for CMOS image sensors and its hardware architecture. The CMOS image sensors as image input devices are becoming popular due to the demand for miniaturized, low-power and cost-effective imaging systems. However, the presence of the dead pixels degrade the image quality. To detect the dead pixels, the proposed algorithm is composed of scan, trace and detection step. The experimental results showed that it could detect 99.99% of dead pixels. It was designed in a hardware description language and total logic gate count is 3.2k using 0.25 CMOS standard cell library.

On-Line Feed-Forward Dead-Time Compensation Method (온라인 전향 데드타임 보상기법)

  • 김현수;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.267-274
    • /
    • 2004
  • In this paper, a new on-line dead-time compensation method is proposed. The output voltage errors due to the dead-time effect is considered as disturbance voltages. The magnitude of the disturbance voltages is estimated using a time delay control technique and the disturbance voltages are calculated using the estimated values, measured currents, and position information. The calculated disturbance voltages are fed to voltage references in order to compensate the dead-time effect. The proposed method is applied to a PM synchronous motor drive system and implemented in a digital manner using a digital signal processor (DSP) TMS320C31. The experiments are carried out for this system to show the effectiveness of the proposed method and the results show the validity of the proposed method.

Dead Time Compensation of Stand-alone Inverter Under Unbalanced Load (불평형부하 시 독립형 인버터의 데드타임 보상기법)

  • Jeong, Jinyong;Jo, Jongmin;Lee, Junwon;Chae, Woo-Kyu;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.115-121
    • /
    • 2015
  • Stand-alone inverter supplies constant voltage to loads. However, when a three-phase stand-alone inverter supplies unbalanced load, the generated output voltages also become unbalanced. The nonlinear characteristics of inverter dead time cause a more serious distortion in the output voltage. With unbalanced load, voltage distortion caused by dead time differs from voltage distortion under balanced load. Phase voltages in the stationary reference frame include unbalanced odd harmonics and then, d-q axis voltages in the synchronous reference frame have even harmonics with different magnitude, which are mitigated by the proposed multiple resonant controller. This study analyzes the voltage distortion caused by unbalanced load and dead time, and proposes a novel dead time compensation method. The proposed control method is tested on a 10-kW stand-alone inverter system, and shows that total harmonic distortion (THD) is reduced to 1.5% from 4.3%.

Compensation Scheme for Dead Time and Inverter Nonlinearity Insensitive to IPMSM Parameter Variations (IPMSM 파라미터 변화에 영향 받지 않는 데드타임 및 인버터 비선형성 보상기법)

  • Park, Dong-Min;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.213-221
    • /
    • 2012
  • In a PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive, a dead time is inserted to prevent a breakdown of switching device caused by the short-circuit of DC link. This distorts the inverter output voltage resulting in a current distortion and torque ripple. In addition to the dead time, nonlinearity exists in switching devices of the PWM inverter, which is generally dependent on operating conditions such as the temperature, DC link voltage, and current. The voltage disturbance caused by the dead time and inverter nonlinearity directly influences on the inverter output performance, and it is known to be more severe at low speed. In this paper, a new compensation scheme for the dead time and inverter nonlinearity under the parameter variation is proposed for a PWM inverter-fed IPMSM drive. The overall system is implemented using DSP TMS320F28335 and the validity of the proposed algorithm is verified through the simulation and experiments.

Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages (임펄스전압에 대한 누전차단기의 부동작 특성)

  • Lee, Bok-Hee;Chang, Sug-Hun;Lee, Seung-Chil
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

A Capacitor Charging Power Supply(CCPS) using Dead Time Control Circuit for Stable High Repetition (안정적 고반복을 위한 지연시간 제어회로가 적용된 커패시터 충전용 전원장치)

  • Lim, Tae Hyun;Hwang, Sun Mook;Kook, Jeong Hyeon;Yim, Dong Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.55-60
    • /
    • 2017
  • Capacitor Charging Power Supply(CCPS) is one of the most important components of a pulsed power system. The CCPS is widely used in source of lasers, accelerators and plasma generators. This paper presents design of a dead time control circuit and operation characteristics for stable high repetition rate of high voltage CCPS. The CCPS consists of battery, high voltage transformer and controller with a dead time control circuit. A dead time control circuit was simulated by PSpice. The performance test of the CCPS was carried out with a 7[nF] load capacitor at output voltage of 50[kV] and a pulse repetition frequency of 100[Hz]. As a result, we can verify that charging and discharging waveform is stable at 100[Hz]. The experiment results indicate that 3[ms] dead time made it possible for stable high repetition rate of 100[Hz]. This paper paves the way for designing an advanced CCPS which is more applicable outside experiments.

Physiological Dead Space and Shunt Following Open Heart Surgery (개심술후 폐의 Physiologic dead space 와 Shunt 의 변화상 추적)

  • 이길노
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.771-779
    • /
    • 1985
  • It has been recognized that the proper matching of ventilation and perfusion within the lung is essential for the efficient exchange of gases following open heart surgery. Physiologic shunt reflects the amount of blood going to lung units with inadequate ventilation and these are also areas of the lung with adequate ventilation but inadequate blood flow. This can be quantified by measuring physiological dead space. From January to August 1985, The physiologic dead space and shunt during postoperative course had been taken in 30 patients of open heart surgery in Soonchunhyang University Hospital. Twenty cases had congenital heart disease and acquired valvular heart disease were noticed in 10 cases. The physiological dead space and shunt during postoperative periods were calculated and we made 5 items of conclusion: 1. There is high probability of ventilation-perfusion mismatch in the acquired heart disease group compared to the congenital group. 2. Duration of the CPB can exert significant influences in the physiological dead space but less in the shunt fraction. 3. There is positive relationship between Qs/Qt and Vd/Vt in the group B [CPB>90 min.] but less reliable in correlation. 4. Perfusion impairment is more significant in the diminished pulmonic blood flow group compared to the increased pulmonic blood flow [Qp/Qs>2.0] group. 5. There is no significant ventilation-perfusion mismatch within the lung during all postoperative courses.

  • PDF

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF

Identification and characteristics of DDX3 gene in the earthworm, Perionyx excavatus (팔딱이 지렁이(Perionyx excavatus) DDX3 유전자의 동정 및 특성)

  • Park, Sang Gil;Bae, Yoon-Hwan;Park, Soon Cheol
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.1
    • /
    • pp.70-81
    • /
    • 2015
  • Helicases are known to be a proteins that use the chemical energy of NTP binding and hydrolyze to separate the complementary strands of double-stranded nucleic acids to single-stranded nucleic acids. They participate in various cellular metabolism in many organisms. DEAD-box proteins are ATP-dependent RNA helicase that participate in all biochemical steps involving RNA. DEAD-box3 (DDX3) gene is belonging to the DEAD-box family and plays an important role in germ cell development in many organisms including not only vertebrate, but also invertebrate during asexual and sexual reproduction and participates in stem cell differentiation during regeneration. In this study, in order to identify and characterize DDX3 gene in the earthworm, Perionyx excavatus having a powerful regeneration capacity, total RNA was isolated from adult head containing clitellum. Full length of DDX3 gene from P. excavatus, Pe-DDX3, was identified by RT-PCR using the total RNA from head as a template. Pe-DDX3 encoded a putative protein of 607 amino acids and it also has the nine conserved motifs of DEAD-box family, which is characteristic of DEAD-box protein family. It was confirmed that Pe-DDX3 has the nine conserved motifs by the comparison of entire amino acids sequence of Pe-DDX3 with other species of different taxa. Phylogenetic analysis revealed that Pe-DDX3 belongs to a DDX3 (PL10) subgroup of DEAD-box protein family. And it displayed a high homology with PL10a, b from P. dumerilii.

A Study on Organophosphate Poisoning Patients: Comparison of the Survivor Group and Dead Group (생존군과 사망군의 비교 분석을 통한 유기인계 살충제 중독환자에 대한 연구)

  • Choi, Youn-Gyu;Lee, Dong-Hyeon;Kim, Woo-Hyung;Lee, Gang-Wook;Kim, Sun-Pyo;Kim, Seong-Jung;Cho, Soo-Hyung;Cho, Nam-Soo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.8 no.1
    • /
    • pp.16-23
    • /
    • 2010
  • Purpose: Organophosphate insecticide poisoning is common in Korea, but there is no definitive guideline for determining the severity of the poisoning and the predictive factors. Therefore, we evaluated the organophosphate poisoned patients and we divided them into two groups, the survivors and the dead, and the results might be useful for treating organophosphate poisoning patients. Methods: We performed a retrospective analysis of 68 organophosphate poisoned patients who visited the Chosun University Hospital Emergency Medical Center during a 24-month period from January, 2007 to December, 2008. We made a work sheet of the patients' characteristics and the collected data was analyzed and we compared this data between the survivor group and the dead patient group. Results: There were significant differences between the survivor group and the dead patient group for the mean age, the alcohol intake state and the typically expressed signs. The dead patients had lower blood pressure, tachycardia and a lower Glasgo Coma Score (GCS) score than the survivor group. On the arterial blood gas analysis, the dead patients had more severe acidemia and they had lower saturations. Increased serum amylase levels were found in the dead patients. The survivors'initial and follow up serum pseudocholinesterase activity (after 6~8 days) was significantly higher than that of the dead group. The total amount of atropine injected to patient was less in the survivors than that in the dead patients. Conclusion: Old age and expressing the typical intoxication signs, a lower GCS score and blood pressure, showing acidosis on the gas analysis and low serum cholinesterase activity may be useful as poor prognostic indicators for patients with organophosphate poisoning. We suggest that physicians must pay careful attention to the signs and prognostic factors of organophosphate insecticide poisoned patients.

  • PDF