• Title/Summary/Keyword: dctA

Search Result 846, Processing Time 0.03 seconds

Adaptive Blind Watermarking Technique by Biased-Shift of Quantizer (양자화기의 편의이동에 의한 적응적인 블라인드 워터마킹 기술)

  • Seo Young-Ho;Choi Hyun-Joon;Choi Soon-Young;Lee Chang-Yeul;Kim Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.49-58
    • /
    • 2005
  • In this paper, we proposed a blind watermarking algerian to use characteristics of a scalar quantizer which is the recommended in the JPEG2000 and JPEG. The proposed algorithm shifts a quantization index according to the value of each watermark bit to prevent losing the watermark information during the compression by quantization. Therefore, the watermark is embedded during the process of quantization, not an additional process for watermarking, and is adaptively applied as a assigned quantizer according application areas. Before embedding process, a LFSR(Linear feedback shift register) rearranged the watermark for the security of the watermark itself and in the embedding process, a LFSR is used to hide the watermarking positions. Therefore the embedded watermark can he extracted by only the owner who knows the initial value of LFSR without the original image. The visual recognizable pattern such as a binary image was used as the watermark. The experimental results showed that the proposed algerian satisfies the robustness and imperceptibility corresponding to the major requirement of watermarking. The results showed the largest error rate to be $5.7\%$ for attack. The experimental result which compares the proposed algorithm with the Mohamed algorithm showed that the proposed algorithm was better than it, exactly $4\~5$ times for the attacks of JPEG and JPEG2000.

Bit Assignment for Wyner-Ziv Video Coding (Wyner-Ziv 비디오 부호화를 위한 비트배정)

  • Park, Jong-Bin;Jeon, Byeung-Woo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.128-138
    • /
    • 2010
  • In this paper, we propose a new bit assignment scheme for Wyner-Ziv video coding. Distributed video coding (DVC) is a new video coding paradigm which enables greatly low complexity encoding because it does not have any motion prediction module at encoder. Therefore, it is very well suited for many applications such as video communication, video surveillance, extremely low power consumption video coding, and other portable applications. Theoretically, the Wyner-Ziv video coding is proved to achieve the same rate-distortion (RD) performance comparable to that of the joint video coding. However, its RD performance has much gap compared to MC-DCT-based video coding such as H.264/AVC. Moreover, Transform Domain Wyner-Ziv (TDWZ) video coding which is a kind of DVC with transform module has difficulty of exact bit assignment because the entire image is treated as a same message. In this paper, we propose a feasible bit assignment algorithm using adaptive quantization matrix selection for the TDWZ video coding. The proposed method can calculate suitable bit amount for each region using the local characteristics of image. Simulation results show that the proposed method can enhance coding performance.

Joint Quality Control of MPEG-2 Video Programs for Digital Broadcasting Services (디지털 방송 서비스를 위한 MPEG-2 비디오 프로그램들의 결합 화질 제어)

  • 홍성훈;김성대
    • Journal of Broadcast Engineering
    • /
    • v.3 no.1
    • /
    • pp.69-84
    • /
    • 1998
  • In digital broadcasting, services such as digital satellite TV, cable TV and digital terrestrial TV, several video programs are compressed by MPEG-2, and then simultaneously transmitted over a conventional CBR (Constant Bit Rate) broadcasting channel. In this paper, we propose a joint quality control scheme to be able to accurately control the relative picture quality among the video programs, which is achieved by simdt;,nL'Ously controlling the video encoders to generate the VBR (Variable Bit Rate) compressed video streams. Our quality control scheme can prevent the video buffer overflow and underflow by total target bit allocation process, and also exactly control the relative picture quality in terms of PSNR (Peak Signal to Noise Ratio) between some programs requiring higher picture quality and others by rate-distortion modification. Furthermore we present a rate-distortion estimation method for MPEG-2 video, which is base of our joint quality control, and verify its performance by experiments. The most attractive features of this estimation method are as follows: 1) computational complexity is low because main operation for the estimation is to calculate the histogram of OCT coefficients into quantizer; 2) estimation results are very accurate enough to be applied to the practical MPEG-2 video coding applications. Simulation results show that the proposed joint quality control scheme accurately controls the relative picture quality among the video progran1s transmitted over a single channel as well as provides more consistent and higher picture quality than independent coding scheme that encodes each program independently.

  • PDF

Digital Hologram Compression Technique using Multi-View Prediction based on Image Accumulation (영상집적 기반의 다시점 부호화 기술을 이용한 디지털 홀로그램의 압축 기술)

  • Choi, Hyun-Jun;Seo, Young-Ho;Bae, Jin-Woo;Yoo, Ji-Sang;Kim, Hwa-Sung;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10C
    • /
    • pp.933-941
    • /
    • 2006
  • In this paper, we proposed an efficient coding method for digital hologram (fringe pattern) acquired by a CCD camera or by computer generation using multi-view prediction technique and MPEG video compression standard technique. It proceeds each R, G, or B color component separately. The basic processing unit is a partial image segmented into the size of $N{\times}N$. Each partial image retains the information of the whole object. This method generates an assembled image for a row of the segmented and frequency-transformed partial images, which is the basis of the coding process. That is, a motion estimation and compensation technique of MPEG is applif:d to the reconstructed images from the assembled images with the disparities found during generation of assembled image and the original partial images. Therefore the compressed results are the disparity of eachpartial image to form the assembled image for the corresponding row, assembled image, and the motion vectors and the compensated image for each partial image. The experimental results with the implemented algorithm showed that the proposed method has NC (Normal Correlation) values about 4% higher than the previous method, by which ours has better compression efficiency. Consequently, the Proposed method is expected to be used effectively in the application areas to transmit the digital hologram data. can be identified in comparison with the previous researches and commercial IPs.

Content Analysis-based Adaptive Filtering in The Compressed Satellite Images (위성영상에서의 적응적 압축잡음 제거 알고리즘)

  • Choi, Tae-Hyeon;Ji, Jeong-Min;Park, Joon-Hoon;Choi, Myung-Jin;Lee, Sang-Keun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.5
    • /
    • pp.84-95
    • /
    • 2011
  • In this paper, we present a deblocking algorithm that removes grid and staircase noises, which are called "blocking artifacts", occurred in the compressed satellite images. Particularly, the given satellite images are compressed with equal quantization coefficients in row according to region complexity, and more complicated regions are compressed more. However, this approach has a problem that relatively less complicated regions within the same row of complicated regions have blocking artifacts. Removing these artifacts with a general deblocking algorithm can blur complex and undesired regions as well. Additionally, the general filter lacks in preserving the curved edges. Therefore, the proposed algorithm presents an adaptive filtering scheme for removing blocking artifacts while preserving the image details including curved edges using the given quantization step size and content analysis. Particularly, WLFPCA (weighted lowpass filter using principle component analysis) is employed to reduce the artifacts around edges. Experimental results showed that the proposed method outperforms SA-DCT in terms of subjective image quality.

The Melanin Inhibition, Anti-aging and Anti-inflammation Effects of Portulaca oleracea Extracts on Cells (쇠비름 추출물의 미백 및 항노화, 항염증 효과)

  • Zhang, Rui;Lee, Hyun-Jin;Yoon, Yeong-Min;Kim, Su-Mi;Kim, Hyun-Sook;Li, Shun Hua;An, Sung-Kwan
    • KSBB Journal
    • /
    • v.24 no.4
    • /
    • pp.397-402
    • /
    • 2009
  • The Portulaca oleracea (P. oleracea) is a popular herbal medicine in East Asia that was known to possess detoxification, antifebrile and antifungal effects. In the present study, we examined the biological activities of ethanol extracts of P. oleracea under various conditions with NIH3T3, B16F10, and MCF-7 cell line model systems. Extracts of P. oleracea (0.5 mg/ml) showed inhibition of expression of tyrosinase, but does not suppress either of TYRP-1 or DCT expression on B16F10 cells. Extracts of P. oleracea (2 mg/ml) showed anti-inflammatory effects on TNF-$\alpha$-stimulated NIH3T3/$NF{\kappa}B$-Luc cells and increase of the synthesis of collagen on NIH3T3 (wild type) cells. These results suggest that extracts of P. oleracea could be used as a functional biomaterial in developing a skin whitening agent and having the anti-inflammatory, anti-wrinkle, and anti-aging activities.

Feature Vector Extraction and Classification Performance Comparison According to Various Settings of Classifiers for Fault Detection and Classification of Induction Motor (유도 전동기의 고장 검출 및 분류를 위한 특징 벡터 추출과 분류기의 다양한 설정에 따른 분류 성능 비교)

  • Kang, Myeong-Su;Nguyen, Thu-Ngoc;Kim, Yong-Min;Kim, Cheol-Hong;Kim, Jong-Myon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.8
    • /
    • pp.446-460
    • /
    • 2011
  • The use of induction motors has been recently increasing with automation in aeronautical and automotive industries, and it playes a significant role. This has motivated that many researchers have studied on developing fault detection and classification systems of an induction motor in order to minimize economical damage caused by its fault. With this reason, this paper proposed feature vector extraction methods based on STE (short-time energy)+SVD (singular value decomposition) and DCT (discrete cosine transform)+SVD techniques to early detect and diagnose faults of induction motors, and classified faults of an induction motor into different types of them by using extracted features as inputs of BPNN (back propagation neural network) and multi-layer SVM (support vector machine). When BPNN and multi-lay SVM are used as classifiers for fault classification, there are many settings that affect classification performance: the number of input layers, the number of hidden layers and learning algorithms for BPNN, and standard deviation values of Gaussian radial basis function for multi-layer SVM. Therefore, this paper quantitatively simulated to find appropriate settings for those classifiers yielding higher classification performance than others.

Impact of Respiratory Motion on Breast Cancer Intensity-modulated Radiation Therapy (유방암 세기조절방사선치료에서의 호흡운동 영향)

  • Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.93-97
    • /
    • 2016
  • In this study, we evaluate the effect of respiration on the dose distribution in patient target volume (PTV) during intensity-modulated radiation therapy (IMRT) and research methods to reduce this impact. The dose distributions, homogeneity index (HI), coverage index (CVI), and conformity index of the PTV, which is calculated from the dose-volume histogram (DVH), are compared between the maximum intensity projection (MIP) image-based plan and other images at respiration phases of 30%, 60% and 90%. In addition, the reducing effect of complication caused by patient respiration is estimated in the case of a bolus and the expended PTV on the skin. The HI is increased by approximately twice, and the CVI is relatively decreased without the bolus at other respiration phases. With the bolus and expended PTV, the change in the dose distribution of the PTV is relatively small with patient respiration. Therefore, the usage of the bolus and expended PTV can be considered as one of the methods to improve the accuracy of IMRT in the treatment of breast cancer patients with respiratory motion.

Spatio-Temporal Semantic Sensor Web based on SSNO (SSNO 기반 시공간 시맨틱 센서 웹)

  • Shin, In-Su;Kim, Su-Jeong;Kim, Jeong-Joon;Han, Ki-Joon
    • Spatial Information Research
    • /
    • v.22 no.5
    • /
    • pp.9-18
    • /
    • 2014
  • According to the recent development of the ubiquitous computing environment, the use of spatio-temporal data from sensors with GPS is increasing, and studies on the Semantic Sensor Web using spatio-temporal data for providing different kinds of services are being actively conducted. Especially, the W3C developed the SSNO(Semantic Sensor Network Ontology) which uses sensor-related standards such as the SWE(Sensor Web Enablement) of OGC and defines classes and properties for expressing sensor data. Since these studies are available for the query processing about non-spatio-temporal sensor data, it is hard to apply them to spatio-temporal sensor data processing which uses spatio-temporal data types and operators. Therefore, in this paper, we developed the SWE based on SSNO which supports the spatio-temporal sensor data types and operators expanding spatial data types and operators in "OpenGIS Simple Feature Specification for SQL" by OGC. The system receives SensorML(Sensor Model Language) and O&M (Observations and Measurements) Schema and converts the data into SSNO. It also performs the efficient query processing which supports spatio-temporal operators and reasoning rules. In addition, we have proved that this system can be utilized for the web service by applying it to a virtual scenario.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.