• Title/Summary/Keyword: dc/ac pwm Inverter

Search Result 142, Processing Time 0.024 seconds

Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps (고압 나트륨 램프 구동용 전력변환장치의 역률 개선)

  • Lee, S.H.;Suh, K.Y.;Lee, H.W.;Lee, S.H.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

A Study of Control Algorithm for Propulsion System (열차 추진제어장치의 알고리즘에 관한 연구)

  • Choi, Jae-Ho;Kim, Hyung-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.51-56
    • /
    • 2007
  • In this paper, control schemes are developed for a propulsion system(Converter/Inverter) in electrical train. A robust controller for PWM converter is proposed. The converter controller consists of a PI controller for DC output voltage and a current controller using error-space approach for maintaining the sinusoidal current waveform and unity power factor. This proposed method is based on characteristic ratio assignment(CRA) method which has the advantage to design the optimal gain to meet the referenced response and overshoot within the limit range. Inverter system is controlled by vector control and slip frequency control. At low speed region, vector control scheme is applied to control instantaneous torque and slip frequency control is performed under overmodulation region and one pulse mode. Because output voltage of converter contains harmonics ripple at twice input ac line frequency, control scheme is developed to reduce the pulsating torque current. The performance of propulsion system will be verified by simulation and prototype experimental results.

Eddy Current Loss Analysis of the Permanent Magnet Brushless AC Motor (영구자석 브러시리스 AC 모터의 와전류 손실 특성해석)

  • Jang, S.M.;Cho, H.W.;Lee, S.H.;Jeong, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.700-702
    • /
    • 2002
  • High-speed brushless permanent magnet machines are good for compressor and aerospace applications, etc. since they are conductive to high efficiency, high power density, small size and low weight. This paper presents 3-phase permanent magnet brushless AC Motor designed for the high-speed drives. Especially, we predicted the inverter high frequency pulse width modulation (PWM) switching caused eddy current losses in a permanent magnet brushless dc motor.

  • PDF

Design Considerations for Low Voltage Claw Pole Type Integrated Starter Generator (ISG) Systems

  • Lee, Geun-Ho;Choi, Geo-Seung;Choi, Woong-Chul
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.527-532
    • /
    • 2011
  • Due to the need for improved fuel consumption and the trend towards increasing the electrical content in automobiles, integrated starter generator (ISG) systems are being considered by the automotive industry. In this paper, in order to change the conventional generator of a vehicle, a belt driven integrated starter generator is considered. The overall ISG system, the design considerations for the claw pole type AC electric machine and a low voltage very high current power stage implementation are discussed. Test data on the low voltage claw pole type machine is presented, and a large current voltage source DC/AC inverter suitable for low voltage integrated starter generator operation is also presented. A metal based PCB (Printed Circuit Board) power unit to attach the 4-parallel MOS-FETs is used to achieve extremely high current capability. Furthermore, issues related to the torque assistance during vehicle acceleration and the generation/regeneration characteristics are discussed. A prototype with the capability of up to 1000 A and 27 V is designed and built to validate the kilo-amp inverter.

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.

Traction System Combined Test of KHST for Propulsion System Performance Verification (한국형 고속전철 추진성능 검증을 위한 추진시스템 통합시험)

  • Ryoo H.J.;Kim J.S.;Kim Y.J.;Knoh A.S.;Jung E.S.;Choi J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.886-890
    • /
    • 2003
  • This paper introduces the combined test results of the traction system for KHST(Korean High Speed Train: hereafter refer to KHST). The main purpose of this combined test is to verify the performance of the traction system that is designed to operate up to maximum 350km/h speed. Combined test system consists of a traction transformer, two AC-DC PWM converters, a PWM Inverter, two traction motors and flywheel system. Flywheel system represents equivalent model of the train inertia. Also traction control system and MASCON Interfaces are included. Various kinds of experiments are performed to prove total traction system performance and detail waveforms are described

  • PDF

Fault Diagnosis of Solar Power Inverter Using Characteristics of Trajectory Image of Current And Tree Model (전류 궤적 영상의 특징과 트리모델을 이용한 태양광 전력 인버터의 고장진단)

  • Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.4
    • /
    • pp.102-108
    • /
    • 2010
  • The photovoltaic system changes solar energy into DC by solar cell and this DC is inverted into AC which is used in general houses by inverter. Recently, the use of power of the photovoltaic system is increased. Therefore, the study of 3 phase solar system to transmit large power is very important. This paper proposes a method that finds simply faults and diagnoses the switch open faults of 3-phase pulse width modulation (PWM) inverter of grid-connected photovoltaic system. The proposed method in $\alpha\beta$ plane uses the patterns of trajectory image as the characteristic parameters and differenciates a normal state and open states of switches. Then, the result is made into tree. The tree is composed of 21 fault patterns and the parameters to classify faults are a shape, a trajectory area, a distributed angle, and a typical vector angle. The result shows that the proposed method diagnosed fault diagnoses, classified correctly them, and made a pattern tree by fault patterns.

A New Voltage Control Method in CRPWM for Improving Distortion and Efficiency at Load Side (출력 파형 왜율과 효율 개선을 위한 CRPWM의 전압 제어 방법)

  • Ahn, Sung-Chan;Song, Jhong-Whan;Cho, Kyu-Bok;Won, Jhong-Su
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1104-1107
    • /
    • 1992
  • Voltage controlled current regulated PWM(pulse width modulation) of VSI (voltage source inverter) is proposed. Adopting one degree of freedom, the voltage, the current controller shows much more improvement than conventional ones not using this method. The voltage controller or this proposal needs load's parameters, torque value, rotational speed. This voltage controller is located at converter part which links AC source and DC bus. With this proposed method, duty ratio of the inverter's switching is nearly unity for all speed and torque range. Hence, this method gets many advantages such as reducing current ripple, thermal loss, and noises and improving control performances. Theoretical approach to this voltage-current controller is performed, and the results are presented.

  • PDF

A study of Voltage Regulation Using Voltage Fed Inverter (전압형 인버터를 이용한 전압조정에 관한 연구)

  • Chung, Y.T.;Lee, S.Y.;Lee, H.G.;Lee, D.H.;Kim, G.D.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.393-396
    • /
    • 1990
  • This paper represented constant voltage power source equipment using voltage fed inverter. This system drived syncronizing power source, charged battery connected to DC side, and constantly maintained regardless of power source voltage variation and load variation. Output made good wave with PWM method and we proved stabile constant voltage output when AC power source is failure.

  • PDF

The Optimization of Current Control in DC/AC Power Converters under Digital Control with Microprocessor (마이크로프로세서에 의한 디지탈 제어방식에서 직류/교류 전력변환장치 전류제어 성능의 최적화)

  • 우명호;목형수;정승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.61-69
    • /
    • 1998
  • In this paper, discrete current control of voltage source inverters is proposed. As a current control scheme, the constant switching frequency predictive current control is adopted and implemented with DSP microprocessor system. In particular, the proposed method is for the compensation of the control lagging due to calculation delays in the microprocessor controller. In controlling the current, the inverter output voltage saturation problem is inevitable and usually affects the current control performance. So, the saturation boundary condition of the inverter output voltage and its effects on the current controal performance of the proposed current control scheme are investigated with experiment. Finally, the proposed scheme is applied to the active power filter system and some results are described for validation.