• Title/Summary/Keyword: damping constant

Search Result 278, Processing Time 0.024 seconds

Studies on Rheological Characterization of Barley ${\beta}-Glucan$ [mixed-linked $(1-3),(1-4)-{\beta}-D-Glucan$] (보리 ${\beta}-Glucan$ [mixed-linked $(1-3),(1-4)-{\beta}-D-Glucan$의 리올로지 특성)

  • Kim, Mi-Ok;Cha, Hee-Sook;Koo, Sung-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • Crude ${\beta}-glucan$ extracted from Barley was purified by stepwise enzyme treatment (Thermostable ${\alpha}-amylase$, amyloglucosidase, protease). The Intrinsic Viscosity $[{\eta}]$ of the purified ${\beta}-glucan$ was determined by Cannon Fenske Capillary Viscometer (size 50, Cannon Instruments, State, College pa.) at different pH (2, 4, 7, 9, 11) and various salt concentration (0.01 M, 0.03 M, 0.05 M, 0.07 M, 0.1 M and 0.2 M). The $[{\eta}]$ of purified ${\beta}-glucan$ was ranged from $0.997{\sim}2.290\;dl/g$. The $[{\eta}]$ of purified ${\beta}-glucan$ at both alkali, acid condition were lower than those at pH 7. However, the alkali condition of puified ${\beta}-glucan$ solution showed less $[{\eta}]$ than the acid condition of this solution. From 0 M to 0.2 M salt concentration, the $[{\eta}]$ of purified ${\beta}-glucan$ solution was decreased to 0.03 M then increased to 0.05 M NaCl and remained constant to 0.2 M NaCl. The chain stiffness parameter of purified ${\beta}-glucan$ was not affected by temperature from $15^{\circ}C$ to $65^{\circ}C$. The shear rates of various ${\beta}-glucan$ conditions were determined by Bohlin Rheometer (Lund, Sweden). The ${\beta}-glucan$ concentration of 1.0 g/dl and 2.0 g/dl behaved as Newtonian fluid. However, above the concentration of 3.0 g/dl ${\beta}-glucan$ solution, it showed thixotropic and psedoplastic characteristics. Barley ${\beta}-glucan$ appears a damping at 0.5 frequency for the 4.0 g/dl solution. Below 0.5 frequency, it appears a viscous behavior property and above 0.5 frequency, it appears a elastic behavior property.

  • PDF

A Study on the Numerical Modeling of the Fish Behabior to the Model Net - Parameter Estimation in Numerical Model of Fish Behavior - (모형그물에 대한 어군행동의 수직 모델링에 관한 연구 - 어군행동을 나타내는 수치 모델의 파라메터 추정 -)

  • Lee, Byoung-Gee;Lee, Dae-Jae;Chang, Ho-Young
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.4
    • /
    • pp.307-325
    • /
    • 1995
  • IN order to gain a fundamental data for forecast or control of fish behavior and evaluated the feasibility of an application of the modeling technique to a field, in this paper a numerical model for describing the behavior of fishes in a water tank was presented. The parameters of the model were estimated by using the time-series data on the three-dimensional position of fishes and by applying the least squares algorithm. The estimated parameters were standardized to examine the variation of parameters according to the number of individuals and flow speed that the mean values of parameters were to be zero and their variances were to be one. The results obtained can be summarized as follows: (1) The standardized parameter $a^*$of propulsive force decreased according to increased the number of individuals and the flow speed. (2) The standardized parameter ${k_b}^*$ of interactive force increased according to increased the number of individuals, but decreased according to the flow speed. (3) The standardized parameter ${k_c}^*$ of schooling force increased according to │increased the number of individuals and the flow speed. (4) The standardized parameter │${k_w}^{+*}$│ of repulsive force against wall or bottom increased according to increased the number of individuals, but decreased according to the flow speed. (5) The standardized parameter │${k_w}^{-*}$│ of attractive force against wall or bottom was generally constant according to increased the number of individuals, but increased according to the flow speed. (6) The standardized parameter $\upsilon$ super(*) of damping force increased according to increased the number of individuals, but decreased according to the flow speed.

  • PDF

Seismic Performance and Flexural Over-strength of Hollow Circular RC Column with Longitudinal Steel Ratio 2.017% (축방향철근비 2.017%인 중공 원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Three small scale hollow circular reinforced concrete columns with aspect ratio 4.5 were tested under cyclic lateral load with constant axial load. Diameter of section is 400 mm, hollow diameter is 200 mm. The selected test variable is transverse steel ratio. Volumetric ratios of spirals of all the columns are 0.302~0.604% in the plastic hinge region. It corresponds to 45.9~91.8% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The longitudinal steel ratio is 2.017%. The axial load ratio is 7%. This paper describes mainly crack behavior, load-displacement hysteresis loop, seismic performance such as equivalent damping ratio, residual displacement and effective stiffness and flexural over-strength of circular reinforced concrete bridge columns with respect to test variable. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications(Limited state design).

Evaluation of Accuracy of Modified Equivalent Linear Method (수정된 등가선형해석기법의 정확성 평가)

  • Jeong, Chang-Gyun;Kwak, Dong-Yeop;Park, Duhee;Kim, Kwangkyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.5-20
    • /
    • 2010
  • One-dimensional equivalent linear site response analysis is widely used in practice due to its simplicity, requiring only few input parameters, and low computational cost. The main limitation of the procedure is that it is essentially a linear method, in which the time dependent change in the soil properties cannot be modeled and constant values of shear modulus and damping is used throughout the duration of the analysis. Various forms of modified equivalent linear analyses have been developed to enhance the accuracy of the equivalent linear method by incorporating the dependence of the shear strain with the loading frequency. The methods are identical in that it uses the shear strain Fourier spectrum as the backbone of the analysis, but differ in the method in which the strain Fourier spectrum is smoothed. This study used two domestically measured soil profiles to perform a series of nonlinear, equivalent linear, and modified equivalent linear site response analyses to verify the accuracy of two modified procedures. The results of the analyses indicate that the modified equivalent linear analysis can highly overestimate the amplification of the high frequency components of the ground motion. The degree of overestimation is dependent on the characteristics of the input ground motion. Use of a motion rich in high frequency contents can result in unrealistic response.

Wind Tunnel Test Study on the Characteristics of Wind-Induced Responses of Tall Buildings with Openings (중공부(中空部)를 가진 고층건축물(高層建築物)의 풍응답(風應答) 특성(特性)에 관한 풍동실험(風洞實驗) 연구(硏究))

  • Kim, Dong Woo;Kil, Yong Sik;Ha, Young Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.499-509
    • /
    • 2005
  • The excessive wind-induced motion of tall buildings most frequently result from vortex-shedding-induced across-wind oscillations. This form of excitation is most pronounced for relatively flexible, lightweight, and lightly damped high-rise buildings with constant cross-sections. This paper discusses the aerodynamic means ofmitigating the across-wind vortex shedding induced in such situations. Openings are added in both the drag and lift directions in the buildings to provide pressure equalization. Theytend to reduce the effectiveness of across-wind forces by reducing their magnitudes and disrupting their spatial correlation. The effects of buildings with several geometries of openings on aerodynamic excitations and displacement responses have been studied for high-rise buildings with square cross-sections and an aspect ratio of 8:1 in a wind tunnel. High-frequency force balance testshave been carried out at the Kumoh National University of Technology using rigid models with 24 kinds of opening shapes. The measured model's aerodynamic excitations and displacement were compared withthose of a square cylinder with no openings to estimate the effectiveness of openings for wind-induced oscillations. From these results, theopening shape, size, and location of buildings to reduce wind-induced vortex shedding and responses were pointed out.

Development of Thickness Measurement Method From Concrete Slab Using Ground Penetrating Radar (GPR 기반 콘크리트 슬래브 시공 두께 검측 기법 개발)

  • Lee, Taemin;Kang, Minju;Choi, Minseo;Jung, Sun-Eung;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.39-47
    • /
    • 2022
  • In this paper, we proposed a thickness measurement method of concrete slab using GPR, and the verification of the suggested algorithm was carried out through real-scale experiment. The thickness measurement algorithm developed in this study is to set the relative dielectric constant based on the unique shape of parabola, and time series data can be converted to thickness information. GPR scanning were conducted in four types of slab structure for noise reduction, including finishing mortar, autoclaved lightweight concrete, and noise damping layer. The thickness obtained by GPR was compared with Boring data, and the average error was 1.95 mm. In order to investigate the effect of finishing materials on the slab, additional three types of finishing materials were placed, and the following average error was 1.70 mm. In addition, sampling interval from device, the effect of radius on the shape of parabola, and Boring error were comprehensively discussed. Based on the experimental verification, GPR scanning and the suggested algorithm have a great potential that they can be applied to the thickness measurement of finishing mortar from concrete slab with high accuracy.

Verification of Frequency-Dependent Equivalent Linear Method (주파수 의존성을 고려한 등가선형해석기법의 검증)

  • Jeong, Chang-Gyun;Kwak, Dong-Yeop;Park, Du-Hee
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.12
    • /
    • pp.113-120
    • /
    • 2008
  • One-dimensional site response analysis is widely used to simulate the seismic site effects. The equivalent linear analysis, which is the most widely used type of site response analysis, is essentially a linear method. The method applies constant shear modulus and damping throughout the frequency range of the input motion, ignoring the dependence of the soil response on the loading frequency. A new type of equivalent linear analysis method that can simulate the frequency dependence of the soil behavior via frequency-strain curve was developed. Various forms of frequency-strain curves were proposed, and all curves were asserted to increase the accuracy of the solution. However, its validity has not been extensively proven and the effect of the shape of the frequency-strain curve is not known. This paper used two previously proposed frequency-strain curves and three additional curves developed in this study to evaluate the accuracy of the frequency-dependent equivalent linear method and the influence of the shape of the frequency-strain curves. In the evaluation, six recordings from three case histories were used. The results of the case study indicated that the shape of the frequency-strain curve has a dominant influence on the calculated response, and that the frequency dependent analysis can enhance the accuracy of the solution. However, a curve that results in the best match for all case histories did not exist and the optimum curve varied for each case. Since the optimum frequency-strain curve can not be defined, it is recommended that a suite of curves be used in the analysis.

Changes in the Organic Compound Contents of the Pear Rootstocks Pyrus calleryana and Pyrus betulaefolia Affected by Excessive Soil Moisture (토양 과습처리에 의한 배 대목 Pyrus calleryana 와 Pyrus betulaefolia 집단의 유기물 함량 변화)

  • Won, KyungHo;Kim, Yoon-Kyeong;Ma, Kyeong-Bok;Shin, Il-Sheob;Lee, Ug-Yong;Lee, Byul-Ha-Na;Choi, Jin-Ho;Lee, In-Bok;Kim, Myung-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.175-183
    • /
    • 2016
  • BACKGROUND: There's a long rainy season during the Summer in Northeast Asia, including Korea. Heavy rainfall during this season causes harm to tree's root, and damped injury in the pear has been continuously reported. Pear Research Institute is breeding damp resistant rootstocks and investigating their mechanisms to relieve damped damages in the pear.METHODS AND RESULTS: Seedlings of Pyrus betulaefolia and P. calleryana were divided into two groups: control and damped, respectively. Damped group was treated by constant irrigation for 77 days and control group was maintained to keep the soil moisture pressure between 0 and -10 kPa. After the treatment, we analysed trees' growth rate, chlorophyll content, amino acids and total phenolic compounds. As a result, P. betulaefolia was sensitive to damped treatment while P. calleryana did not have significant differences between the control and damped treatment. It was observed that total contents for phenolic compounds were dramatically increased in P. betulaefolia while trees' growth rate, chlorophyll b and general amino acid contents were lowered by damping treatment.CONCLUSION: In some pear cultivars, growth habit is suppressed by damped damage. Pyrus calleryana displayed tolerances to damped damage in growth rate and some organic compound contents compared to P. betulaefolia. So we recommend to exploit P. calleryana as a pear rootstock rather than using P. betulaefolia.