• 제목/요약/키워드: damage cost function

검색결과 91건 처리시간 0.024초

무폭약 시험 장치 개발을 위한 수중폭발 특성에 대한 연구 (A Study on the Characteristics of Underwater Explosion for the Development of a Non-Explosive Test System)

  • 이한솔;박규동;나양섭;이승규;박경훈;정현
    • 대한조선학회논문집
    • /
    • 제57권6호
    • /
    • pp.322-330
    • /
    • 2020
  • This study deals with underwater explosion (UNDEX) characteristics of various non-explosive underwater shock sources for the development of non-explosive underwater shock testing devices. UNDEX can neutralize ships' structure and the equipment onboard causing serious damage to combat and survivability. The shock proof performance of naval ships has been for a long time studied through simulations, but full-scale Live Fire Test and Evaluation (LFT&E) using real explosives have been limited due to the high risk and cost. For this reason, many researches have been tried to develop full scale ship shock tests without using actual explosives. In this study, experiments were conducted to find the characteristics of the underwater shock waves from actual explosive and non-explosive shock sources such as the airbag inflators and Vaporizing Foil Actuator (VFA). In order to derive the empirical equation for the maximum pressure value of the underwater shock wave generated by the non-explosive impact source, repeated experiments were conducted according to the number and distance. In addition, a Shock Response Spectrum (SRS) technique, which is a frequency-based function, was used to compare the response of floating bodies generated by underwater shock waves from each explosion source. In order to compare the magnitude of the underwater shock waves generated by each explosion source, Keel Shock Factor (KSF), which is a measure for estimating the amount of shock experienced by a naval ship from an underwater explosionan, was used.

COBie-IM 및 BIM 기반 건축물 점검 및 유지보수 정보관리방안 제시 (Proposed Information Management Plan for Building Inspection and Maintenance Based on COBie-IM and BIM)

  • 이채원;김상용
    • 한국건축시공학회지
    • /
    • 제23권1호
    • /
    • pp.57-68
    • /
    • 2023
  • 노후화된 건축물이 정상적인 기능을 유지하기 위해서는 주기적인 점검과 보수·보강이 수행되어야 한다. 하지만 현재 건축물 유지관리 단계에서 발생하는 정보의 형태와 의사결정은 여전히 비효율적인 방식에 의존하고 있다. 이는 건축물 유지 관리에서 발생하는 비용의 증가와 시간 낭비의 원인이다. 이에 본 연구는 COBie를 벤치마킹하여 건축물 점검 및 유지보수 정보 관리용 COBie-IM 문서를 제안하고 이를 BIM에 연계하여 정보를 확인하는 방안을 제시하였다. 또한, 건축물에서 발생한 결함의 손상등급에 따라 색상을 지정하여 시각화하는 방안을 제시하였다. 이를 통해 건축물 유지관리 단계에서 점검 및 유지보수 시 발생하는 정보들을 체계적으로 통합·관리하는 것을 목표로 한다. 또한, 결함에 대한 보수·보강의 우선순위를 결정하는 의사결정을 지원함으로써 업무 효율성을 증대시킬 수 있을 것으로 예상된다.

섬유시트로 보강된 T형 철근콘크리트보의 휨 강도 해석 (Flexural Strength Analysis of RC T-Beams Strengthened Using Fiber Sheets)

  • 박대효;이규철
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.234-245
    • /
    • 2003
  • 대부분의 콘크리트 교량 구조물은 과도한 교통량과 구조물의 사용수명의 도래로 손상된다. 콘크리트의 손상은 철근의 부식과 콘크리트와 철근의 분리로 인하여 성능저하 촉진의 원인이 된다. 손상된 콘크리트 구조물의 빠른 복원은 콘크리트 구조 체계에서 콘크리트 성능저하의 심화를 막기 위하여 매우 중요하게 되었다. 최근 섬유시트는 고인장강도, 내구성, 부식저항성, 경량성, 제작편리성, 비용절감, 균열 제어, 두께 대비 고강도, 사용성 등의 많은 장점이 원인이 되어 손상된 콘크리트 구조물의 보강에 널리 사용되고 있다. 그러나 섬유시트 보강에 따른 공칭휨모멘트 성능을 예측하는 방법에 대한 해석과정의 결여로 구조물의 보강 과정에서 효과적인 인자의 결정이 어렵게 된다. 본 연구에서는 T형 철근콘크리트보의 보강을 위해 부재의 밑면에 부착된 섬유시트가 휨 강도에 미치게 되는 영향이 연구된다. 또한 밑면섬유시트의 박리 방지를 위해 감싸는 섬유시트의 옆면부분에 의한 부수적인 휨 보강 효과가 이론적으로 조사된다. 제안한 접근방법을 입증하기 위하여 해석 결과가 참고된 다른 실험연구의 결과와 비교된다. 예측된 결과와 실험결과는 잘 일치하였다.

실외 센서네트워크 기반 재해방지 시스템을 위한 위험지역 예측기법 (Dangerous Area Prediction Technique for Preventing Disaster based on Outside Sensor Network)

  • 정영진;김학철;류근호
    • 정보처리학회논문지D
    • /
    • 제13D권6호
    • /
    • pp.775-788
    • /
    • 2006
  • 무선 통신 기술의 발달과 무선기기의 소형화, 그리고 환경에 대한 감지와 제어를 수행하는 센서 네트워크 기술의 확산으로 환경오염, 터널 및 건축물의 붕괴, 홍수, 태풍, 지진 등의 재난에 대비하기 위한 재해 감시 시스템에 대한 연구가 활발히 진행되고 있다. 재해 감시 시스템은 원격지의 상태 정보를 검출하고, 재해 상황을 판단하기 위한 규칙 처리 과정 후, 인식된 상황에 따라 방재작업을 지원한다. 그러나 기존의 모니터링 시스템들은 주로 현재 데이터를 위주로 간단한 집계함수 및 연산자만을 지원하기 때문에, 재해를 미리 예측하고 방재하기에는 부족한 점이 있다. 따라서 이 논문에서는 실외 센서 네트워크 및 공간 정보를 고려하여 재해 위험 지역을 미리 예측하는 재해 방지 시스템을 설계, 구현한다. 제시된 위험 지역 예측 기법은 현재 센서 데이터를 토대로 시간에 대한 공간 정보의 변화를 고려하여 미래에 재해 위험이 있는 지역을 추정하여 제시한다. 이로 인해 재해를 미리 예측하고 방비할 수 있게 되고, 재해 피해 감소 및 복구비용을 줄일 수 있다. 제시된 재해 방지 시스템과 위험 지역 예측 기법은 센서네트워크를 기반으로 하는 다양한 재해 방지 시스템에 활용되어 재해 예방 및 피해 감소에 많은 도움을 줄 수 있다.

Open versus closed reduction of mandibular condyle fractures : A systematic review of comparative studies

  • Kim, Jong-Sik;Seo, Hyun-Soo;Kim, Ki-Young;Song, Yun-Jung;Kim, Seon-Ah;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권1호
    • /
    • pp.99-107
    • /
    • 2008
  • Objective : The objective of this review was to provide reliable comparative results regarding the effectiveness of any interventions either open or closed that can be used in the management of fractured mandibular condyle Patients and Methods : Research of studies from MEDLINE and Cochrane since 1990 was done. Controlled vocabulary terms were used. MeSH Terms were "Mandibular condyle" AND "Fractures, bone". Only comparative study were considered in this review using the "limit" function. According to the criteria, two review authors independently assessed the abstracts of studies resulting from the searches. The studies were divided according to some criteria, and following were measured: Ramus height, condyle sagittal displacement, condyle Towns's image displacement, Maximum open length, Protrusion & Lateral excursion, TMJ pain, Malocclusion, and TMJ disorder. Results : Many studies were analyzed to review the post-operative result of the two methods of treatment. Ramus height decreased more in when treated by closed reduction as opposed to open reduction. Sagittal condyle displacement was shown to be greater in closed reduction. Condyle Town's image condyle displacement had greater values in closed reduction. Maximum open length showed lower values in closed reduction. In protrusive and lateral movement, closed reduction was less than ORIF. Closed reduction showed greater occurrence of malocclusion than ORIF. However, post-operative pain and discomfort was greater in ORIF. Conclusion : In almost all categories, ORIF showed better results than CRIF. However, the use of the open reduction method should be considered due to the potential surgical morbidity and increased hospitalization time and cost. To these days, Endoscopic surgical techniques for ORIF (EORIF) are now in their infancy with the specific aims of eliminating concern for damage to the facial nerve and of reducing or eliminating facial scars. Before performing any types of treatment, patients must be understood of both of the treatment methods, and the best treatment method should be taken on permission.

쌀 분말을 이용한 유아용 파우더의 이화학적 특성 연구 (Studies of Physicochemical Properties of Baby Powder Developed from Rice-flour)

  • 한상익;장기창;서우덕;오성환;나지은;송유천;이종희;김병주;남민희;이진태
    • 생명과학회지
    • /
    • 제23권7호
    • /
    • pp.879-885
    • /
    • 2013
  • 유아용 파우더는 유아의 기저귀 발진을 방지하거나 기타 다른 화장용 파우더의 원료로 사용되고 있고 그 주성분은 일반적으로 광물질인 탈크 분말이 주로 이용되고 있다. 탈크 분말은 사용에 있어 호흡기로 흡입하게 되면 심각한 폐 손상 등을 야기하여 위험하다고 알려져 있다. 쌀 분말을 이용한 유아용 파우더를 개발하기 위하여 3종류의 쌀 품종이 사용되었고, 곱게 분쇄하였다. 최적의 유아용 파우더를 얻기 위해 몇 단계의 분쇄과정을 거쳤고, 파우더에 대한 오일과 실리콘 코팅 처리 전후의 파우더 입자크기, 생리활성, 색차, 수분 흡수율 등의 파우더 특성을 검정하였다. 분말의 색택과 입자 크기 등의 특성에서 고아미 품종의 파우더가 우수한 특성을 보였고, 전자현미경 관찰결과 오일과 실리콘 오일 코팅한 쌀 파우더가 탈크에 비해 둥글고 부드러운 모양을 나타내었다. 또한 오일과 실리콘 코팅에 의해 평균 입자크기가 줄어드는 현상을 나타내었으며 쌀 분말의 단점인 수분흡수를 차단하여 파우더로서 우수한 특성을 유지함을 보였다.

시설물 안전점검을 위한 E-PAD 기반 상태평가 시스템 개발 (Development of E-PAD based condition evaluation system for facility safety inspection)

  • 정해용;이흥수;이종화;김영석;박철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권4호
    • /
    • pp.1-7
    • /
    • 2019
  • 국가 주요 시설물의 안전점검 업무가 일원화됨에 따라 업무 효율성과 전문성 강화 등의 효과가 기대되고 있다. 세계적으로 시설물의 물리적 기능적 결함을 초기에 발견하는 외관조사의 중요성이 강조되고 있다. 이에 본 연구에서는 기존 외관조사 방법의 문제와 한계를 극복하기 위해 시설물 안전점검을 위한 E-PAD기반 상태평가 시스템을 개발하였다. 본 시스템은 시설개요, 작업목록, 외관조사, 결함표로 구성되어 있으며, 현장에서 외관조사망도를 다운받아 조사된 손상 및 정보를 입력하고, 평가 등급을 확인할 수 있다. 본 시스템의 검증을 위해 교량 10개소에 대한 외관조사 데이터를 입력하여 기존 안전등급을 비교하였다. 그 결과 시스템에서 산출된 안전등급과 기존 안전등급이 동일한 것으로 확인되었다. 또한 AHP기법을 통해 타당성 분석 결과 기존 방법 대비 기능 10%증가, 비용 36%감소, 가치 30%증가한 것으로 분석되었다. 따라서, 시설물 관리 수준 향상을 위해 체계적인 데이터 구축 및 정보 분석을 위한 시스템으로 기여할 것으로 기대된다.

PEDOT:PSS/MWNT 나노복합체의 나노주름 임프린팅을 통한 투명전극-배향막 복합 기능 박막의 액정 구동 (Liquid Crystal Driving of Transparent Electrode-Alignment Layer Multifunctional Thin Film by Nano-Wrinkle Imprinting of PEDOT:PSS/MWNT Nanocomposite)

  • 장종인;정해창
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.8-17
    • /
    • 2023
  • 기존 liquid crystal display(LCD) 공정에서 Indium Tin Oxide(ITO) 투명전극과 폴리이미드 배향막의 러빙 공정은 액정을 정렬하고 전계를 인가하기 위하여 필수적인 공정이다. 하지만 ITO의 증착은 높은 진공을 요구하며, 러빙 공정은 정전기에 의해 소자가 손상될 수 있는 단점이 존재한다. 본 논문에서는 기존 ITO 투명전극을 대체하기 위하여 PEDOT:PSS와 Multi-wall carbon nanotube(MWNT)를 혼합하여 PEDOT:PSS 나노복합체를 제조하고, 러빙 공정을 대체하기 위하여 나노 주름 구조 몰드를 통한 나노임프린팅을 통하여 박막을 형성함으로써 기존 액정 디스플레이의 투명전극과 배향막 두 가지 박막을 PEDOT:PSS/MWNT 나노복합체 박막 하나만으로 기능하게 하여 공정을 단순화 하였다. 전사된 나노 주름을 따라 액정이 잘 배향됨을 확인하였으며, 이를 기반으로 만들어진 액정 셀에서 박막 내 MWNT의 함량이 높아질수록 박막의 전기전도도가 증가하여 낮은 구동 전압과 빠른 응답 속도를 갖는다는 것을 확인하였다. 본 연구를 통해 공정 단순화와 용액공정에 의한 공정 단가 절감, 기존 러빙 공정의 단점을 해결하는데 기여 할 수 있을 것으로 기대된다.

WIM 자료를 활용한 화물차 축하중 분포 모형 개발 (Development of Truck Axle Load Distribution Model using WIM Data)

  • 이동석;오주삼
    • 대한토목학회논문집
    • /
    • 제26권5D호
    • /
    • pp.821-829
    • /
    • 2006
  • 교통하중은 포장 설계 및 해석에서 가장 중요한 입력 변수로서 포장 파손의 주요 원인이 된다. 따라서 정확한 포장 설계 및 해석을 위해서는 적절한 교통하중 정량화가 선행되어야 한다. 전통적으로 교통하중은 혼합된 교통흐름을 설계목적의 하나의 값으로 변환시켜주는 ESALs 관점에서 추정되어왔으나 이는 AASHO 도로 테스트를 통해 도출된 지극히 경험적인 값으로 전 노선망에 대해 평균적인 계수로 적용하기에는 한계가 있다. 이러한 등가단축하중계수의 문제점을 해결하기 위해 선진국에서는 역학적 개념을 도입한 많은 연구를 진행한 결과 역학적-경험적 설계법(Mechanistic-Empirical Design)에 적용할 수 있는 축하중 분포(Axle Load Spectra)를 이용한 교통하중 정량화 방안을 수립하였다. 본 논문에서는 일반국도에 설치 운영되고 있는 WIM 시스템을 통해 수집된 화물차 하중 데이터를 이용하여 축하중 분포 특성(Axle Load Spectra)을 이해하고 혼합정규분포함수에 기초한 축 형태별 하중 분포 모형식을 제시하였으며, 이를 기존 하중 분포 모형과 비교 평가하였다. 본 논문에서 제시한 화물차 축하중 분포 특성 및 축하중 분포 모형식은 향후 일반국도 및 고속도로의 포장 설계법 개발을 위한 교통하중 정량화 방안 수립 시, 과적 차량 단속 정책 수립 시, 도로 유지관리를 위한 계획 수립 시 기초자료로써 활용가능하다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF