• 제목/요약/키워드: daily monitoring

검색결과 758건 처리시간 0.027초

부산 지역의 SO$_2$ 농도 변화 특성에 관한 고찰 (On the Characteristics of the SO$_2$ Concentration Variation in Pusan, Korea)

  • 전병일;김유근;이화운
    • 한국대기환경학회지
    • /
    • 제10권4호
    • /
    • pp.245-251
    • /
    • 1994
  • We considered that characteristics of SO$_2$, concentration level and relations of the meteorological parameters and high pollution concentration from the data measured 7 air quality continuous monitoring stations during 4 years, from 1990 to 1993 in Pusan. The SO$_2$ concentration level showed decreasing trend yearly, it was maximum in Winter, minimum in Summer. The time of SO$_2$ peak concentration lagged from seashore to land because of break-down of the nocturnal inversion layer and seabreeze. Ihe correlations of daily SO$_2$, value between various air quality continuous monitoring stations were highest between Beomcheondong and Meongryundong, lowest between Daeyeondong and Sinpyeongdong because of difference of air Pollution emission sources characteristic. The meteorological parameters affecting SO$_2$ concentration level were minimum temperature, relative humidity, wind speed and air pressure. The SO$_2$ high pollution($\geq$95ppb) occurred almost in Winter, particulaly in such day showing lower wind speed and higher air pressure. Elementary SO$_2$ high Pollution Predictor were high pressure system and stability of lower atmosphere.

  • PDF

화학 발암물질에 대한 인체 암 위해성 평가 (Methodology of Human Cancer Risk Assessment for Chemical Carcinogens)

  • 이병무
    • Toxicological Research
    • /
    • 제8권2호
    • /
    • pp.317-329
    • /
    • 1992
  • Fifty chemicals are currently classified as human carcinogens based on epidemiologic and animal data. Humans are daily exposed to them from various sources of exposure via inhalation, dermal contact and oral ingestion. To reduce cancer risk to man, these human carcinogens should be appropriately regulated and monitored environmentally or biologically for routine human cancer risk assessment. A number of mathematical risk assessment models have been introduced, but any realistic and relevant model system is not available for humans. A mechanistic process for human cancer risk assessment was comprehensively reviewed and problems were also discussed. Here, a new conceptual approach using epidemiology and biological human monitoring was suggested for the most relevant method to study human cancer risk assessment.

  • PDF

지능형 레이더 기술 동향 (Trends in Intelligent Radar Technology)

  • 구본태;박필재;한선호
    • 전자통신동향분석
    • /
    • 제36권2호
    • /
    • pp.12-21
    • /
    • 2021
  • Intelligent radar sensors are applied in many industries, such as the automobile, aerospace, and defense industries (for security and surveillance), and for traffic monitoring and management as well as environmental and weather monitoring. Furthermore, they are used in smart cities, homes, and buildings, wherein intelligent motion sensing is required in daily life. It is mentioned that it is being used. In addition, ETRI introduces a phased array-based intelligent radar for drone detection and a human name detection radar technology based on which humans can be detected in case of a disaster.

산사태 모니터링 오탐지율 개선을 위한 토양수분자료 활용에 관한 연구 (A study of applying soil moisture for improving false alarm rates in monitoring landslides)

  • 오승철;정재환;최민하;윤홍식
    • 한국수자원학회논문집
    • /
    • 제54권12호
    • /
    • pp.1205-1214
    • /
    • 2021
  • 강수는 공극수압의 상승에 관여해 토양 강도 및 응력의 변동을 발생시켜 산사태의 주요 원인 인자 중 하나로 지목된다. 따라서 강수는 산사태 발생 임계값 산정에 빈번히 사용되나, 지반 안정성을 직접적으로 산정하고 예측하기에는 무리가 있어 오탐지 사건에 대한 분석에는 한계가 있다. 한편 토양수분은 공극수압의 변동에 보다 직접적인 연관성을 지니므로, 다수의 연구에서 지반 안정성의 정량적인 평가에 활용된 바 있다. 이에 본 연구에서는 산사태 발생에 대한 임계값 산정에 있어 토양수분 인자 활용의 적정성을 평가하고자 하였다. 먼저 두 수문 인자의 거동 분석을 통해 강수에 대한 토양 포화도의 반응성을 파악하고, 선행 강수지수(Antecedent Precipitation Index)를 활용해 산사태 발생 임계값을 산정하였다. 이후 토양 포화도를 활용하여 산사태 발생 임계값을 산정했으며, 분할표를 활용해 두 임계값을 정성적으로 평가하였다. 그 결과, 일 강수량(Pdaily)을 단일 인자로 사용해 결정된 산사태 발생 임계값 대비 괴산읍에서는 각각 75% (API), 42% (SM)의 향상을 보였고 창수면에서는 각각 33% (API), 44% (SM)의 향상을 보였다. 따라서 토양수분과 선행 강수지수 모두 임계성공지수(Critical Success Index)를 효과적으로 향상시켰으며 오탐지율을 감소시켰다. 추후 토양 포화도를 통해 산사태 발생에 요구되는 강우 강도를 산정하는 연구와 토양 포화도 수준에 따른 강우 저항성을 산정하는 연구 등 토양수분 자료를 다각적으로 접목한 연구가 수행된다면 산사태 예측 정확성을 향상시키는 데 기여할 수 있을 것으로 보인다.

수도권에서 오존생성 기여도 산출에 관한 연구 (Evaluation of Incremental Reactivity and Ozone Production Contribution of VOCs Using the PAMS Data in Seoul Metropolitan Area)

  • 이종현;한진석;윤혜경;조석연
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.286-296
    • /
    • 2007
  • Ozone creation potentials suited for Seoul metropolitan area was derived by utilizing the PAMS monitoring data and the source inventory. A simple box model with variable height was developed to calculate the incremental reactivity for all the ozone episode days in the year 2003 and 2004. RIR (Relative Incremental Reactivity) was introduced as a measure of contribution to ozone generation in the Seoul metropolitan area. RIR was defined as a function of ratio of VOC to $NO_x$ and therefore it addresses both VOC and $NO_x$ limited regime. For the days that more than 10 monitoring stations out of 27 monitoring station in Seoul recorded the daily maximum ozone concentrations higher than 70 ppb, toluene had the highest RIR value in all the type II and type III PAMS site and m/p-xylene followed with the second highest RIR value. Analyses using MIR (Maximum Incremental Reactivity) and POCP (Photochemical Ozone Creation Potential) instead of RIR also yields dominance of toluene and m/p-xylene in generating ozone concentrations to demonstrate the validity of RIR.

무구속적 맥파 전달 시간의 측정을 통한 혈압 추정 (Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure)

  • 지영준;박광석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

대구지역 PM10 오염 관리를 위한 시간적 및 공간적 오염 특성 평가 (Evaluation of Temporal and Spatial PM10 Characteristics for Pollution Management in Daegu area)

  • 조완근;권기동
    • 한국환경과학회지
    • /
    • 제13권1호
    • /
    • pp.27-36
    • /
    • 2004
  • Present study analyzed the temporal and spatial characteristics of PM10 pollution in Metropolitan Daegu area based on air pollution monitoring station data and measurements of PM10 concentrations in background area in order to provide essential data for efficient PM10 pollution management. The significant variation of spatial and temporal PM10 concentrations in Daegu area was observed during the study years. The highest maximum PM10 concentration(332 $\mu\textrm{g}$/㎥), average concentration(88 $\mu\textrm{g}$/㎥) and frequency exceeding PM10 daily standard(150 $\mu\textrm{g}$/㎥) were all observed in Namsandong located near a major roadway. The hourly and weekly variations of PM10 concentrations had different pattern for the measurement sites. The monthly and seasonal concentrations exhibited a notable characteristic: the maximum concentration was obtained in spring season, most likely due to Yellow sand effects. Furthermore, this temporal variation of PM10 pollution varied with study site. Meanwhile, the PM10 values measured at the monitoring site, Manchondong, were comparable with those of a control site. The average PM10 concentration ranged from 23 $\mu\textrm{g}$/㎥ to 115 $\mu\textrm{g}$/㎥ with a mean value of 53 $\mu\textrm{g}$/㎥ in the former site and from 22 $\mu\textrm{g}$/㎥ to 91 $\mu\textrm{g}$/㎥ with a mean value of 45 $\mu\textrm{g}$/㎥ in the latter site.

위해성 평가 및 관리에 있어서 발암물질의 인체발암능력 평가 (Estimation of Human Carcinogenic Potency (HCP) of Carcinogens in Risk Assessment and Management.)

  • 이병무;김대영;김세기;김근종
    • 한국환경성돌연변이발암원학회지
    • /
    • 제19권1호
    • /
    • pp.39-45
    • /
    • 1999
  • Human Carcinogenic Potency (HCP) can be estimated based on human daily exposure dose to carcinogen (Dh), body weight (Wh), 10% tumorigenic dose (TD10), and slope factor at TD10 (Q10) from 2-yr bioassay data. This approach is more relevant to humans generally exposed to low doses of carcinogens and can reduce more of extrapolation errors from high dose in animal experiments to low dose in humans than HERP (human exposure dose/rodent potency dose) proposed by Ames et al. (Science, 236, 271-280, 1987). TD50 and HERP have been routinely used to compare rodent carcinogenic potency and human carcinogenic potency, but those approaches have had limitations in extrapolation of high dose to low dose in humans. The advantages of HCP are to estimate human exposure dose (Dh) by human monitoring instead of environmental monitoring, to consider slope factor (Q10) which reflects the tendency of curve at low dose, and to use TD10 which represents much lower dose thant TD50 or HERP. HCP will be a useful parameter for the estimation of human carcinogenic potency in risk assessment and management of carcinogens.

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.

CardioSentinal: A 24-hour Heart Care and Monitoring System

  • Gao, Min;Zhang, Qian;Ni, Lionel;Liu, Yunhuai;Tang, Xiaoxi
    • Journal of Computing Science and Engineering
    • /
    • 제6권1호
    • /
    • pp.67-78
    • /
    • 2012
  • People are willing to spend more for their health. Traditional medical services are hospital-centric and patients obtain their treatments mainly at the clinics or hospitals. As people age, more medical services are needed to exceed the potentials of this hospital-centric service model. In this paper, we present the design and implementation of CardioSentinal, a 24-hour heart care and monitoring system. CardioSentinal is designed for in-home and daily medical services. It mainly focuses on the outpatients and elderly. CardioSentinal is an interdisciplinary system that integrates recent advances in many fields such as bio-sensors, small-range wireless communications, pervasive computing, cellular networks and modern data centers. We conducted numerous clinic trials for CardioSentinal. Experimental results show that the sensitivity and accuracy are quite high. It is not as good as the professional measurements in hospital due to harsh environments but the system provides valuable information for heart diseases with low-cost and extreme convenience. Some early experiences and lessons in the work will also be reported.