• Title/Summary/Keyword: daily inspection

Search Result 92, Processing Time 0.018 seconds

Effects of Tailored Occupational Activity Program applied to Patients with Dementia and Their Caregiver in Community (지역사회에 거주하는 치매환자와 보호자에게 적용한 맞춤형 작업 활동 프로그램의 효과)

  • Hwang, Yun-Jung;Lee, Kamg Sook;Lim, Hyun-Kook;Kim, Dai Jin;Jeong, Won-Mee
    • 한국노년학
    • /
    • v.31 no.1
    • /
    • pp.129-141
    • /
    • 2011
  • This study aims to find out effects of a tailored occupational activity program(TOAP) on the activities of daily living(ADL), cognitive function, depressive mood, and caregiver burden, who live in the community. Method : From October 2009 to May 2010, the TOAP was applied to 15 dementia patients and 15 of their caregivers, who was visitors of the Y-city Center for Managing Dementia in Gyunggi-do. The TOAP was designed for habituating patients and caregivers to the techniques acquired through goal activities and task and making it capable of being routinized regularly. The TOAP was applied to dementia patients and their cvaregivers twice a week for 7 weeks(one-time home visit, one-time phone inspection), a total of 14 times. Results: Significant differences among pre-test and post-test were found in the AMPS motor skills(1.10±1.14 and 1.34±1.2 respectively) scores, AMPS process skills(0.32±0.55 and 0.77±0.66 respectively) scores, ACL(3.86±0.65 and 4.17±0.64 respectively) scores, MMSE-KC(17.33±4.6 and 19.33±4.97 respectively) scores, GDS(11.73±6.87 and 8.53±7.09 respectively) scores, and caregiver burden(31.80±20.06 and 26.13±18.07 respectively) scores(p<0.05). A significant effect was confirmed from the TOAP which ADL, cognitive function, reduced patient's depression and caregiver burden(p<0.05). Conclusion: From the above results that a TOAP has an effect on the improvement of the ability to ADL, cognitive function and reduced depression and caregiver burden of dementia patients living in community. The present author hopes that, in the future, more diverse community based on tailored occupational activity programs will be developed to improve the functions of dementia patients living in community.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF