• Title/Summary/Keyword: dB-linear

Search Result 1,040, Processing Time 0.031 seconds

A Linear Precoding Technique for OFDM Systems with Cyclic Delay Diversity

  • Hui, Bing;Chang, Kyung-Hi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.2 no.5
    • /
    • pp.253-264
    • /
    • 2008
  • Cyclic delay diversity (CDD) is considered a simple approach to exploit the frequency diversity, to improve the system performance in orthogonal frequency division multiplexing (OFDM) systems. Also, the linear precoding technique can significantly improve the performance of communication systems by exploiting the channel state information (CSI). In order to achieve enhanced performance, we propose applying linear precoding to the conventional CDD-OFDM transmit diversity schemes over Rayleigh fading channels. The proposed scheme works effectively with the accurate CSI in time-division-duplex (TDD) OFDM systems with CDD, where the reciprocity is assumed instead of channel state feedback. For a BER of $10^{-4}$ and the mobility of 3 km/h, simulation results show that a gain of 6 dB is achieved by the proposed scheme over both flat fading and Pedestrian A (Ped A) channels, compared to the conventional CDD-OFDM system. On the other hand, for a mobility of 120 km/h, a gain of 2.7 dB and 3.8 dB is achieved in flat fading and Vehicular A (Veh A) channels, respectively.

Nonlinear Product Codes and Their Low Complexity Iterative Decoding

  • Kim, Hae-Sik;Markarian, Garik;Da Rocha, Valdemar C. Jr.
    • ETRI Journal
    • /
    • v.32 no.4
    • /
    • pp.588-595
    • /
    • 2010
  • This paper proposes encoding and decoding for nonlinear product codes and investigates the performance of nonlinear product codes. The proposed nonlinear product codes are constructed as N-dimensional product codes where the constituent codes are nonlinear binary codes derived from the linear codes over higher order alphabets, for example, Preparata or Kerdock codes. The performance and the complexity of the proposed construction are evaluated using the well-known nonlinear Nordstrom-Robinson code, which is presented in the generalized array code format with a low complexity trellis. The proposed construction shows the additional coding gain, reduced error floor, and lower implementation complexity. The (64, 24, 12) nonlinear binary product code has an effective gain of about 2.5 dB and 1 dB gain at a BER of $10^{-6}$ when compared to the (64, 15, 16) linear product code and the (64, 24, 10) linear product code, respectively. The (256, 64, 36) nonlinear binary product code composed of two Nordstrom-Robinson codes has an effective gain of about 0.7 dB at a BER of $10^{-5}$ when compared to the (256, 64, 25) linear product code composed of two (16, 8, 5) quasi-cyclic codes.

SUBPERMUTABLE SUBGROUPS OF SKEW LINEAR GROUPS AND UNIT GROUPS OF REAL GROUP ALGEBRAS

  • Le, Qui Danh;Nguyen, Trung Nghia;Nguyen, Kim Ngoc
    • Bulletin of the Korean Mathematical Society
    • /
    • v.58 no.1
    • /
    • pp.225-234
    • /
    • 2021
  • Let D be a division ring and n > 1 be an integer. In this paper, it is shown that if D ≠ ��3, then every subpermutable subgroup of the general skew linear group GLn(D) is normal. By applying this result, we show that every subpermutable subgroup of the unit group (ℝG)∗ of the real group algebras RG of finite groups G is normal in (ℝG)∗.

A Design of Novel Instrumentation Amplifier Using a Fully-Differential Linear OTA (완전-차동 선형 OTA를 사용한 새로운 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • A novel instrumentation amplifier (IA) using fully-differential linear operational transconductance amplifier (FLOTA) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of a FLOTA, two resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into FLOTA converts into two same difference currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the FLOTA and realized the IA used commercial op-amp LF356. Simulation results show that the FLOTA has linearity error of 0.1% and offset current of 2.1uA at input dynamic range ${\pm}3.0V$. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the 60dB was 10MHz. The proposed IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 105mW at supply voltage of ${\pm}5V$.

WEYL STRUCTURES ON COMPACT CONNECTED LIE GROUPS

  • Park, Joon-Sik;Pyo, Yong-Soo;Shin, Young-Lim
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.24 no.3
    • /
    • pp.503-515
    • /
    • 2011
  • Let G be a compact connected semisimple Lie group, B the Killing form of the algebra g of G, and g the invariant metric induced by B. Then, we obtain a necessary and sufficient condition for a left invariant linear connection D with a Weyl structure ($D,\;g,\;{\omega}$) on (G, g) to be projectively flat (resp. Einstein-Weyl). And, we also get that if a left invariant linear connection D with a Weyl structure ($D,\;g,\;{\omega}$) on (G, g) which has symmetric Ricci tensor $Ric^D$ is projectively flat, then the connection D is Einstein-Weyl; but the converse is not true. Moreover, we show that if a left invariant connection D with Weyl structure ($D,\;g,\;{\omega}$) on (G, g) is projectively flat (resp. Einstein-Weyl), then D is a Yang-Mills connection.

REMARKS ON GAUSSIAN OPERATOR SEMI-STABLE DISTRIBUTIONS

  • Chae, Hong Chul;Choi, Gyeong Suk
    • Korean Journal of Mathematics
    • /
    • v.8 no.2
    • /
    • pp.111-119
    • /
    • 2000
  • For a linear operator Q from $R^d$ into $R^d$. ${\alpha}$ > 0 and 0 < $b$ < 1, the Gaussian (Q, $b$, ${\alpha}$)-semi-stability of probability measures on $R^d$ is investigated.

  • PDF

Relationship between Lead Levels in Blood and Urine and Laboratory Test Values among Lead Exposed Workers (저농도 연 폭로근로자들의 혈중 및 요중 연량과 생화학적 검사치들 간의 관련성)

  • 김종숙;정용준;조영채
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.30-40
    • /
    • 2003
  • The study subjects included the workers who were estimated to have been exposed in a low density of lead-laden glaze from pottery manufacturers. They were evaluated in terms of PbB and PbU as indices of lead concentration in the body, and Hb, Hct, ALAD, and FEP as indices of biochemical lead poisoning. Consequently, the study results revealed the relationship between each of indices and its effectiveness to indicate the degree of occupational lead exposure. 1. The mean of PbB was $22.85{\;}{\mu}g/d{\ell}$(range; $4.2~44.7{\;}{\mu}g/d{\ell}$) and PbU $45.69{\mu}g/d{\ell}$(range; $6.7~87.5{\mu}g/d{\ell}$), to indicate the level of lead exposure in the subjects. 2. While there was a high, linear correlation between PbB, PbU and FEP (r=0.835, r=0.855, respectively), a low correlation existed between PbB and ALAD(r=-0.240). 3. While there was a high, linear correlation between PbU and FEP(r=0.825), a low correlation existed between PbU and ALAD(r=-0.352). The above results suggest that FEP can be used as a highly useful biochemical index of lead poisoning, based on its high correlation with PbB and PbU indicating lead concentration in the body.

LFM Radar Implemented in SDR Architecture (SDR 기반의 LFM 레이다 설계 및 구현)

  • Yoon, Jae-Hyuk;Yoo, Seung-Oh;Lee, Dong-Ju;Ye, Sung-Hyuck
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.308-315
    • /
    • 2018
  • In this paper, we present the basic design results for high-resolution radar development at S-band frequency that can precisely measure the miss distance between two targets. The basic system requirement is proposed for the design of a 3.5 GHz linear frequency-modulated (LFM) radar with maximum detection distance and distance resolution of 2 km and 1 m, respectively, and the specifications of each module are determined using the radar equation. Our calculations revealed a signal-to-noise ratio ${\geq}30dB$ with a bandwidth of 150 MHz, transmission power of 43 dBm for the power amplifier, gain of 26 dBi for the antenna, noise figure of 8 dB, and radar cross-section of $1m^2$ at a target distance of 2 km from the radar. Based on the calculation results and the theory and method of LFM radar design, the hardware was designed using software defined radar technology. The results of the subsequent field test are presented that prove that the designed radar system satisfies the requirements.