• Title/Summary/Keyword: dB difference

Search Result 1,889, Processing Time 0.03 seconds

Adaptive Enhancement Algorithm of Perceptual Filter Using Variable Threshold (가변 임계값을 이용한 지각 필터의 적응적인 음질 개선 알고리즘)

  • 차형태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.6
    • /
    • pp.446-453
    • /
    • 2004
  • In this paper, a new adaptive perceptual filter using variable threshold to enhance audio signals degraded by additively nonstationary noise is proposed. The adaptive perceptual filter updates variable threshold each time according to the power of signal and the effect of noise variation. So the noisy audio signal is enhanced by the method which controls a residual noise effectively. The proposed algorithm uses the perceptual filter which transforms a time domain signal into frequency domain and calculates an intensity energy and an excitation energy in bark domain. In this method. the stage updated the response of filter is decided by threshold. The proposed algorithm using vairable threshold effectively controls a residual noise using the energy difference of audio signals degraded by the additive nonstationary noise. The proposed method is tested with the noisy audio signals degraded by nonstationary noise at various signal -to-noise ratios (SNR). We carry out NMR and MOS test when the input SNR is 15dB. 20dB. 25dB and 30dB. An approximate improvement of 17.4dB. 15.3dB, 12.8dB. 9.8dB in NMR and enhancement of 2.9, 2.5, 2.3, 1.7 in MOS test is achieved with the input signals. respectively.

Analysis of Emission Characteristics of DC/DC Converter with different Parts Layout (부품배치가 다르게 제작된 DC/DC컨버터의 Emission 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.179-183
    • /
    • 2019
  • The system stability must be ensured from the switching noise due to the power conversion efficiency and power conversion system miniaturization. Therefore, countermeasures to reduce switching noise during power conversion are essential. Thus, in the previous paper, we constructed the DC / DC Buck Converter circuit using MPQ4432 driver of MPS, and simulated the switching noise characteristics which occurs when the components are arranged differently in the 4 - layer PCB circuit structure with reference plane. In this paper, two different simulated circuits are fabricated and the characteristics of the conducted emission and the radiated emission are analyzed in the same way as the simulation. As a result, it was confirmed that the Conducted Emission characteristic was reduced by 2 ~ 9dB in the low frequency band and 6 ~ 7dB in the high frequency band depending on the configuration of the current return path. And the radiated emission characteristic is reduced by 9 dB. Conducted emission simulation results show that 6 ~ 7dB in the low frequency range and 2 ~ 9dB in the measurement result are somewhat different. In the high frequency band, it is confirmed that the experimental and simulation results are about 7dB. And Radiated Emission confirmed 12dB decrease in simulation, but confirmed decrease of 9dB in measurement result. It is confirmed that there is a slight difference in the amount of reduction, but the design of the power conversion circuit improves the noise characteristics according to the configuration of the current return path.

Evaluation of floor impact sound and airborne sound insulation performance of cross laminated timber slabs and their toppings (구조용 직교 집성판 슬래브와 상부 토핑 조건에 따른 바닥충격음 및 공기전달음 평가)

  • Hyo-Jin Lee;Yeon-Su Ha;Sang-Joon Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.572-583
    • /
    • 2023
  • Demand for wood in construction is increasing worldwide. In Korea, technical reviews of high-rise Cross Laminated Timber (CLT) buildings are under way. In this paper, Floor Impact Sound Insulation Performance (FISIP) and Transmission Loss (TL) of 150 mm thick CLT floor panels made of two domestic species, Larix kaempferi and Pinus densiflora, are investigated. The CLT slabs were tested in reverberation chambers connected vertically. When comparing Single Number Quantity (SNQ) of FISIP of the bare panels, the Larix CLT is 3 dB lower in heavy-weight and 1 dB in light-weight than the Pinus CLT. However, there was no difference when concrete toppings were added to improve the performance. As the concrete toppings became thicker, the heavy-weight was reduced by 9 dB ~ 20 dB, and the light-weight by 20 dB ~ 30 dB. And the analysis of these results with area density has confirmed that the area densities are highly correlated (R2 = 0.94 ~ 0.99) to the FISIP of the CLT. The types of CLT didn't affect the TL. Comparison of theoretical TL values with measured TL values has shown that the frequency characteristics are similar but 8 dB ~ 12 dB lower in measured values. The relationship between the TL and frequency characteristics of the tested CLT slabs was derived by using the correction value.

Effects of Heat Treatment History of Skim Milk Powder on the Quality Characteristics of RTD Coffee with High Protein (탈지분유의 열처리 공정이 고단백질 RTD 커피의 품질 특성에 미치는 영향)

  • Ko, Bong Soo;Lee, Seok Ryong;Han, Sung Hee
    • Culinary science and hospitality research
    • /
    • v.24 no.1
    • /
    • pp.24-30
    • /
    • 2018
  • This study investigated the quality of characteristics of high-protein RTD coffee using domestic and imported skim milk powder with different heat treatment. Skim milk powders (A, B) had high-heat treatment, C had medium-heat, and D and E had low-heat treatment. The transmittance of A and B were higher than that of C, and that of C were higher than that of D and E (p<0.05). The precipitate attached on bottom of container of RTD coffee using A and B were 2.993~3.053% and higher than those (0.753~0.803%) of RTD coffee using C, D and E (p<0.05), but there was no difference between those of RTD coffee using C, D and E (p<0.05). The centrifuged precipitate of RTD coffee using A and B were 1.987~2.040% and higher than those (0.820~0.830%) of RTD coffee using C, D and E (p<0.05), but there was no difference between those of RTD coffee using C, D and E (p<0.05). The proximate composition of precipitate attached on bottom of container of RTD coffee using A, which showed the highest amount of precipitate, showed 65.7% of carbohydrate, 19.0% of protein, 4.8% of fat and 4.8% of ash in dry basis, that of RTD coffee being 72.7%, 15.1%, 7.9% and 4.3% in dry basis respectively. Protein and fat content of precipitate were lower and protein and ash content were higher than those of RTD coffee. But seeing that the most increased portion was protein, precipitation of RTD coffee appears to be attributed to heat-denatured proteins.

Improved Hypophysectomy Technique by Sublaryngeal A, pp.oach and the Efficacy of bGH in Hypophysectomized Female Rats (흰쥐에서 후두하경로를 통한 하수체 적출술의 개량과 하수체 적출 흰쥐를 이용한 bGH 효능시험)

  • 정영채;김창근;이종완;나광빈;김광식;박선애;유영아;이세영
    • Korean Journal of Animal Reproduction
    • /
    • v.21 no.2
    • /
    • pp.197-205
    • /
    • 1997
  • Improved hypophysectomy technique and the efficacy of bGH in hypophysectomized female rats were studied as a basis for the function of endocrine gland and hormones. 1. With improved sublaryngeal a, pp.oach by hypophysectomy, 34 rats out of 40 were successfully hypophysectomized(more than 80% of success). The surgical time for hypophysectomy per rat was taken about 3.0$\pm$1.0 min. 2. For the effect of hypophysectomy and bGH on body weight gain among the 5 gruops of A, B, C, D, and E, the weight gains for A, B, C, D, and E, were 93g, 9.2g, 10.7g, 25.1g and 36.2g, respectively, which implied that hypophysectomy had a major effect on body weight. And also, the effect of bGH was paralleled with the level of bGH. There were significant difference between control and hypophysectomized groups, and between the bGH treated and bGH non-treated groups after hypophysectomy(p<0.01). 3. For the effect of hypophysectomy and bGH on the length of femur, tibia, humerus, and anterbrachi, longest was for A, shortest for B, and longer in order of C, D, and E. The A group was significantly longer than B, C, D, and E groups. The B group was shorter than C, D, and E groups(p<0.01). 4. For the effect of hypophysectomy and bGH on the weight of femur, tibia, humerus, and antebrachi, heaviest was for A, lightest for B, and heavier in order of C, D, and E. The A group was significantly heavier than B, C, D, and E groups. The B group was lighter than C, D, and E groups(p<0.01). 5. In changes of body length, and weights of liver and heart, A group was most drastically increased. Among the hypophysectomized groups, the change was increased in order of B, C, D, and E. Especially, the change of A group was significantly greater than B, C, D and E gruops. However, no significant differences were found among B, C, D, and E groups. 6. The hypophysectomy in rat had a significant effect on body growth. The effect of hormone was remarkably different depending upon the level of hormone. It was found that 300$\mu\textrm{g}$ of bGH/kg of body wt/day was slightly lower for normal growth.

  • PDF

Comparative Analysis on the Sound Characteristics of Riffles and Pools (여울과 소의 소리특성 비교 분석)

  • Kang, Su-Jin;Kang, Joon-Gu;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.878-886
    • /
    • 2018
  • This study quantified the sounds of riffles and pools in natural rivers and conducted a comparative analysis of the frequency and sound pressure per flow velocity. The surveyed area was Namdaecheon basin in Yangyang-gun, Gangwon-do and the sounds of a total of 23 sites were analyzed. A hydro microphone was used to measure the sound and analyze the data using an acoustic analysis program. The location was also selected at places with minimal ambient noise and the measurement points were the depth of riffles and pools. The results revealed an average difference of 0.515 m/s for flow velocity at 8 riffles and 15 pools. The difference in sound pressure occurred due to the flow velocity. In the case of sound pressure, it was measured at an average of 176.8 dB for riffles and 168.2 dB for pools, demonstrating a difference of approximately 8.6 dB. Furthermore, in the case of maximum sound pressure, riffles showed a constant range between 200 Hz and 250 Hz, while the pools exhibited maximum sound pressure at various frequencies from 200 Hz to 1,000 Hz. This revealed the ecological stream reproduction, development of preferred sound sources for aquatic life, and design of structures.

The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design - (수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로-)

  • 박문갑;윤갑동;김석제;윤종락
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2001
  • The underwater background noise measured in Geoje and Tongyoung diving fishing ground from May to December, 2000 and analyzed to get optimum carrier frequency and transmitter power level for underwater wireless telephone design. The results obtained are summarized as follows: 1. At the Geoje and Tongyoung diving fishing ground, the lowest ambient noise band was 25~30kHz with 57dB and 52dB re 1$\mu$Pa, respectively. 2. At the Geoje and Tongyoung diving fishing ground, the lowest noise band during fishing activity was 67dB and 62dB re 1$\mu$Pa, respectively. 3. At the Geoje diving fishing ground, the noise of water jetter which is a digging machine for subbottom shells was 102dB re 1$\mu$Pa. 4. Considering the design parameters of underwater wireless telephone, it is found that the optimum carrier frequency band is around 30kHz and the transmitter source level should be at least 131dB re 1$\mu$Pa for 500m range telephone.

  • PDF

Effect of Crossbred Korean Native Ducks on the Retail Cut Yield, Meat Quality, and Sensory Evaluation of Duck Meats (토종오리의 교배 조합이 오리고기의 부분육 생산수율, 육질 및 관능검사에 미치는 영향)

  • Kim, Hak-Kyu;Hong, Eui-Chul;Kang, Bo-Seok;Park, Mi-Na;Chae, Hyun-Seok;Bang, Han-Tae;Seo, Bo-Young;Choo, Hyo-Jun;Na, Seung-Hwan;Seo, Ok-Suk;HwangBo, Jong
    • Korean Journal of Poultry Science
    • /
    • v.37 no.4
    • /
    • pp.423-431
    • /
    • 2010
  • This work was carried out to investigate on the retail cut yield and the meat quality of crossbred ducks. A total of 360 pullets that were produced from 4 mating methods used in this work. Four mating method were A) native ducks (female) $\times$ native ducks (male), B) meat-type ducks (female) $\times$ native ducks (male), C) native ducks (female) $\times$ meat-type ducks (male), and D) meat-type ducks (female) $\times$ meat-type ducks (male). Ducks were bred at the flat house, and selected nine ducks with similar weights from each treatment at the certain weeks (A, B, C 8 weeks; D 6 weeks). Selected ducks were slaughtered, calculated the retail cut yield(wing, back, neck, breast, leg), analyzed the physico-chemical compositions, and tested the sensory evaluation. Wing and neck meat ratios of D treatment were lowest (P<0.05), and breast meat ratio of B treatment was high (P<0.05) compared to other treatments. pH of duck meat was no difference among treatments, fat and protein contents of B treatment was highest, and collagen contents of D treatment was highest among all treatments. Meat color and physical compositions was no difference among treatments. Juiciness of D treatment meats was highest, and there was no difference between B and D treatments. Finally, mating method of native duck and meat-type duck affected on the retail cut yield, but did not improve on the physico-chemical compositions and sensory evaluation.

A Design of Novel Instrumentation Amplifier Using a Fully-Differential Linear OTA (완전-차동 선형 OTA를 사용한 새로운 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • A novel instrumentation amplifier (IA) using fully-differential linear operational transconductance amplifier (FLOTA) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of a FLOTA, two resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into FLOTA converts into two same difference currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the FLOTA and realized the IA used commercial op-amp LF356. Simulation results show that the FLOTA has linearity error of 0.1% and offset current of 2.1uA at input dynamic range ${\pm}3.0V$. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the 60dB was 10MHz. The proposed IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 105mW at supply voltage of ${\pm}5V$.

Influence of roadside buildings on the noise in the backside blocks in city area (도시내 가로변 빌딩이 도로 이면지역의 소음에 미치는 영향)

  • Kim, Yong-Seong;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.352-362
    • /
    • 2019
  • The old residences and shops in the backside blocks are affected by the traffic noises from the main road. The noise of the backside roads is affected by the following factors such as the height of the roadside buildings, the distance between the road and the backside streets, distance among adjacent roadside buildings, and the difference of the adjacent building heights. The both noise levels on the road and the backside street were measured simultaneously in 15 urban blocks of a city which can be categorized into two types of roadside building plans ; 1) one single building along the street, 2) buildings arranged on one axis beside the road. As the results, there is no significant noise reduction due to the width of the buildings in general. However, in the cases of buildings arranged on one axis beside the road, it was found that the average noise reduction was 12 dB(A) on the basis of the building height of 4 m. Also, it was analysed that for each 4 m increase in the building height, noise reduction occurred by 2 dB(A) beyond building height of 4 m. In general, it was proved that the noise of the back streets is mainly affected by the lowest height of the roadside buildings. It was found that noise is increased by 1 dB(A) for each 4 m increase of the height difference between adjacent buildings. Also, It was revealed that for each 0.5 m increase in the distance between roadside building, noise reduction decreased by 1 dB(A).