The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.

Coupled T-H-M Processes Calculations in KENTEX Facility Used for Validation Test of a HLW Disposal System (고준위 방사성 폐기물 처분 시스템 실증 실험용 KENTEX 장치에서의 열-수리-역학 연동현상 해석)

  • Park Jeong-Hwa;Lee Jae-Owan;Kwon Sang-Ki;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.117-131
    • /
    • 2006
  • A coupled T-H-M(Thermo-Hydro-Mechanical) analysis was carried out for KENTEX (KAERI Engineering-scale T-H-M Experiment for Engineered Barrier System), which is a facility for validating the coupled T-H-M behavior in the engineered barrier system of the Korean reference HLW(high-level waste) disposal system. The changes of temperature, water saturation, and stress were estimated based on the coupled T-H-M analysis, and the influence of the types of mechanical constitutive material laws was investigated by using elastic model, poroelastic model, and poroelastic-plastic model. The analysis was done using ABAQUS, which is a commercial finite element code for general purposes. From the analysis, it was observed that the temperature in the bentonite increased sharply for a couple of days after heating the heater and then slowly increased to a constant value. The temperatures at all locations were nearly at a steady state after about 37.5 days. In the steady state, the temperature was maintained at $90^{\circ}C$ at the interface between the heater and the bentonite and at about $70^{\circ}C$ at the interface between the bentonite and the confining cylinder. The variation of the water saturation with time in bentonite was almost same independent of the material laws used in the coupled T-H-M processes. By comparing the saturation change of T-H-M and that of H-M(Hydro-Mechanical) processes using elastic and poroelastic material mod31 respectively, it was found that the degree of saturation near the heater from T-H-M calculation was higher than that from the coupled H-M calculation mainly because of the thermal flux, which seemed to speed up the saturation. The stresses in three cases with different material laws were increased with time. By comparing the stress change in H-M calculation using poroelasetic and poroelasetic-plastic model, it was possible to conclude that the influence of saturation on the stress change is higher than the influence of temperature. It is, therefore, recommended to use a material law, which can model the elastic-plastic behavior of buffer, since the coupled T-H-M processes in buffer is affected by the variation of void ratio, thermal expansion, as well as swelling pressure.

  • PDF

Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin (광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구)

  • Choi, Yong-Hoon;Bae, Ji-Hyun;Son, Ho-Hyun;Lee, In-Bog;Um, Chung-Moon;Baek, Seung-Ho;Kim, Oh-Young;Kim, Chang-Keun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives : This study investigated the hypothesis that increasing light-curing time would leave the oxygen-inhibited layer (OIL) of the adhesive thinner, and in turn, result in lower shear bond strength (SBS) than those obtained by the routine curing procedures. Methods:120 human extracted posterior teeth were randomly divided into three groups for bonding with three adhesives:All Bond 2/sup (R)/, One Step/sup (R)/, and Adper Prompt/sup (R)/. They were subsequently divided into four subgourps with different light-curing time (10, 20, 30 and 60s). The assigned adhesives were applied on superficial occlusal dentin according to the manufacturer's instructions and cured with one of the four curing times. Composite resin cylinder, 2.35㎜ in diameter, were built on the cured adhesive and light-cured for 40s. SBS were measured after 24h from the bonding using a universal testing machine (crosshead speed 1.0 ㎜/min). The relative thickness of the OIL and the degree of conversion (DC) were determined from the adhesive on a slide glass using FT-NIR in an absorbance mode. Data were analysed with One-way ANOVA and Duncan's multiple test (p〈0.05), Results:With increasing cure time, although there were no significant difference in th SBS of One-step and Adper Prompt (p〉0.05), those of All Bond 2 decreased significantly (p〈0.05). The relative thicknesses of the OIL on each adhesive were not affected by the cure time (p〉0.05). Although the DC of All-Bond 2 were statistically not different with increasing cure time (p〉0.05), those of One-Step and Adper Prompt showed an increasing trends with increasing cure time (p〈0.05). Conclusions:Increasing light-curing time did not affect on the relative thickness of the OIL of the adhesives, and in turn, on the SBS to dentin.

MICROTENSILE BOND STRENGTH OF ALL-IN-ONE ADHESIVE TO CARIES-AFFECTED DENTIN (우식이환 상아질에 대한 all-in-one adhesive의 미세인장결합강도)

  • Moon, Ji-Deok;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength to caries-affected dentin. Twenty one extracted human molars with occlusal caries extending into mid-dentin were prepared by grinding the occlusal surface flat. The carious lesions were excavated with the aid of caries detector dye. The following adhesives were applied to caries-affected dentin according to manufacturer's directions; $Scotchbond^{TM}$ Multi-Purpose in SM group, Adper Prompt $L-Pop^{TM}$ 1 coat in LP1 group, 2 coats in LP2 group, 3 coats in LP3 group, $Xeno^{(R)}$ III 1 coat in XN1 group, 2 coats in XN2 group. and 3 coats in XN3 group. After application of the adhesives, a cylinder of resin-based composite was built up on the occlusal surface. Each tooth was sectioned vertically to obtain the $1{\times}1\;mm^2$ sticks. The microtensile bond strength was determined. Each specimen was observed under SEM to examine the failure mode. Data were analyzed with one-way ANOVA. The results of this study were as follows; 1. The microtensile bond strength values were; SM ($14.38{\pm}2.01$ MPa), LP1 ($9.15{\pm}1.81$ MPa), LP2(14.08{\pm}1.75$ MPa), LP3 ($14.06{\pm}1.45$ MPa). XN1 (13.65{\pm}1.95$ MPa). XN2 ($13.98{\pm}1.60$) MPa, XN3 ($13.88{\pm}1.66$) MPa, LP1 was significantly lower than the other groups in bond strength (p < 0.05). All groups except LP1 were not significantly different in bond strength (p > 0.05). 2. In LP1, there were a higher number of specimens showing adhesive failure. Most specimens of all groups except LP1 showed mixed failure.

Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS) (EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링)

  • Woo, Seong-Yeop;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.651-662
    • /
    • 2022
  • The electrochemical impedance spectroscopy(EIS) method was used to evaluate the concrete deterioration process related to chloride-induced steel corrosion with various corrosion levels(initiation, rust propagation and acceleration periods). The impressed current technique, with four total current levels of 0C, 13C, 65C and 130C, was used to accelerate steel corrosion in concrete cylinder samples with w/c ratio of 0.4, 0.5, and 0.6, immersed in a 0.5M NaCl solution. A series of EIS measurements was performed to monitor concrete deterioration during the accelerated corrosion test in this study. Some critical parameters of the equivalent circuit were obtained through the EIS analysis. It was observed that the charge transfer resistance(Rc) dropped sharply as the impressed current increased from 0C to 13C, indicating a value of approximately 10kΩcm2. However, the sensitivity of Rc significantly decreased when the impressed current was further increased from 13C to 130C after corrosion of steel had been initiated. Meanwhile, the double-layer capacitance value(Cdl) linearly increased from 50×10-6μF/cm2 to 250×10-6μF/cm2 as the impressed current in creased from 0C to 130C. The results in this study showed that monitoring Cdl is an effective measurement parameter for evaluating the progress of internal concrete damages(de-bonding between steel and concrete, micro-cracks, and surface-breaking cracks) induced by steel corrosion. The findings of this study provide a fundamental basis for developing an embedded sensor and signal interpretation method for monitoring concrete deterioration due to steel corrosion at various corrosion levels.

Nutritional Studies for Improvement of Feeding on Korean Native Goat - Absorption of Nutrients in Rumen - (한국재래산양(韓國在來山羊)의 사양개선(飼養改善)에 관(關)한 연구(硏究) - 제일위((第一胃)에서의 영양소(營養素) 흡수(吸收)에 대(對)하여 -)

  • Kwon, Soon Ki
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.284-302
    • /
    • 1982
  • Development of protein resources as food has been a big issue especially in Southeast Asia region, and intake of protein is also insufficient in Korea. To cope with this shortage of protein resources and its improvement together with increased production of high nutritive animal protein, studies were carried out on feeding of Korean native goats. In the experiments were made absorption of carbohydrate and volatile fatty acid in miniature rumen, and absorption of amino acid in rumen as in vivo were conducted as part of studies on nutritional absorption in rumen. Those nutritional for improvement of feeding and management as described above are summarized as following. 1. According to the result of test on the nutritional absorption of native goat by means of miniature rumen method, absorption ratio of VFA measured at 0.5, 1 and 2 hours after injection of nutrition showed propionic acid 70-86%, acetic acid 74-87%, and lactic acid 76-89%. In the absorption of organic substances, ethyl alcohol of 0.5% showed 29-87% and lactic acid of 0.1M showed 12-27% of absorption ratio. 2. Result of absorption measurement in rumen from L-type free amino acid injection in the content of rumen vein showed lower rate at menthionine-free group compared to whole-egg amino acid injection in the content of rumen vein showed lower rate at methioine-free group compared to whole-egg amino acid group, and high absorption ratio was observed at methionine 3 times group and urea added group. Deficiency of methionine caused no change of the content in mucous membranes. 3. Absorption of amino acid in rumen muscular layer showed equal tendency as in the mucous membrane without exerting any influence of methionine deficiency. At the methionine3-times group, content of methionine and glutamine were increased by 14.7 and 4.4 times as compared to whole-egg amino acid group, an absorption ratio of glutamine, proline and valine were increased at urea added group. 4. In general, concentration of amino acid in rumen vein plasma was lower than in rumen mucous membrane and muscular layer. Absorption ratio of amino acid is decreased due to methionine deficiency, and tripling of methionine or urea adding caused increment of amino acid. Absorption pattern is thus varied depending on the composition of amino acid. 5. At the urea added group, content of ammonia-N, amino-N and urea were increased in rumen muscular layer. As the inside of goat's rumen was unable to clean thoroughly, investigation was made on remaining bacteria, however, variation of ammonia-N was affected by these bacterial content. 6. Variation in rumen structure by differential absorption of amino acid was observed by general microscope and fluorescent microscope. According to the result of observation in the methionine 3 times group, single cylinder epithelium of mucous membrane showed rather thin, and it was thick at urea added group though no significant differences existed among test groups in submucous membrane and muscular layer.

  • PDF

Studies on the Antibiotic Residues in Milk of Cows, Goats and Dogs (유우(乳牛), 산양(山羊) 및 견(犬)의 유즙내(乳汁內) 잔류항생물질(殘留抗生物質)에 관한 연구(硏究))

  • Kim, Kyo Jun
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.1
    • /
    • pp.199-231
    • /
    • 1975
  • It is well known fact that antibiotic residues in milk of cows create significant problem for the fermented dairy industry and public health because of inhibition of starter activity and of creation of allergic disease. It can be assumed that antibiotic residues in milk of other aniimals also can create some problems for their infants as in the case of humen. For the above mentioned reasons, present studies were undertaken to determine concentration and duration of antibiotic residues in milk of cows, goats and dogs following intramuscular or intravenous injection and intramammary infusion of penicillin, streptomycin and oxytetracycline at usual dosage. The cylinder-plate method was used for their assay. The results obtained were summerized as follows: 1) Following the intramuscular injection of penicillin, the antibiotic was detected in milk of cows up to 72 hours, in milk of goats 48 hours and in milk of dogs 60 hours of postinjection. The mean peak concentrations were recorded at 12 hours as 0.136 I.U./ml in cows. 6 hours as 0.773 I.U./ml in goats and 3 hours as 1.192 I.U./ml in dogs. 2) Following the intramuscular injection of streptomycin, the antibiotic was detected in milk of cows and goats up to 36 hours and in milk of dogs 24 hours of post-injection. The mean peak concentration were recorded at 6 hours as $0.26{\mu}g/ml$ in cows and at 3 hours in goats and dogs $0.45{\mu}g/ml$ and $0.36{\mu}g/ml$ respectively. 3) Following the intra venous injection of oxytetracycline, the antibiotic was detectable in milk of all the test animals up to 48 hours of postinjection. The mean peak concentrations were recorded at 6 hours as $3.5{\mu}g/ml$ in cows $2.4{\mu}g/ml$ in goats and $2.0{\mu}g/ml$ in dogs respectively. 4) Following intrarnammary infusion of penicillin in amounts of 100,000 I.U. for cows, 20.000 I.U. for goats and 10,000 I.U. for dogs, the penicillin residues in milk of the infused quarter perssisted to 72 hours in cows and 84 hours in goats and dogs. 5) Following intramammary infusion of streptomycin in amount of 500mg for cows, 100mg for goats and 25mg for dogs, the streptomycin residues in milk of the infused quarter persisted to 72 hours in cows and goats and 60 hours in dogs. 6) Following intramammary infusion of oxytetracycline in amount of 500mg for cows, 100mg for goats and 25mg for dogs, the oxytetracycline residues in milk of the infused quarter persisted to 72 hours in cows and 60 hours in goats and dogs. 7) A corelation between the residual antibiotic concentration and milk yield in cows and goats was observed; That is, the lower in the milk production showed a higher the concentration of an antibiotic residues and a longer the time in persistance. 8) Intramammary transfer of the antibiotic from an infused to non infused quarters, in dogs, was observed following the intramammary infusion of penicillin. streptomycin and oxytetracyclne in amounts of 10.000 I.U. 25mg and 25mg respectively. However, no transfer by 100.000 I.U. or 20.000 I.U. of penicillin. 500mg of streptomycin and 100mg of oxytetracyline was observed in cows and goats. 9) In dogs, minimum dosage of antibiotics for transfer fro in treated to untreated quarters following intramammary infusion were 2,500 I.U. of penicillin and 5mg each of streptomycin and oxytetracycline.

  • PDF