• 제목/요약/키워드: cyclic shear test

검색결과 428건 처리시간 0.024초

Shear deformation model for reinforced concrete columns

  • Sezen, Halil
    • Structural Engineering and Mechanics
    • /
    • 제28권1호
    • /
    • pp.39-52
    • /
    • 2008
  • Column shear failures observed during recent earthquakes and experimental data indicate that shear deformations are typically associated with the amount of transverse reinforcement, column aspect ratio, axial load, and a few other parameters. It was shown that in some columns shear displacements can be significantly large, especially after flexural yielding. In this paper, a piecewise linear model is developed to predict an envelope of the cyclic shear response including the shear displacement and corresponding strength predictions at the first shear cracking, peak strength, onset of lateral strength degradation, and loss of axial-load-carrying capacity. Part of the proposed model is developed using the analysis results from the Modified Compression Field Theory (MCFT). The results from the proposed model, which uses simplified equations, are compared with the column test data.

Shear mechanism of steel fiber reinforced concrete deep coupling beams

  • Li, Kou;Zhao, Jun;Ren, Wenbo
    • Structural Engineering and Mechanics
    • /
    • 제73권2호
    • /
    • pp.143-152
    • /
    • 2020
  • Deep coupling beams are more prone to suffer brittle shear failure. The addition of steel fibers to seismic members such as coupling beams can improve their shear performance and ductility. Based on the test results of steel fiber reinforced concrete(SFRC) coupling beams with span-to-depth ratio between 1.5 and 2.5 under lateral reverse cyclic load, the shear mechanism were analyzed by using strut-and-tie model theory, and the effects of the span-to-depth ratio, compressive strength and volume fraction of steel fiber on shear strengths were also discussed. A simplified calculation method to predict the shear capacity of SFRC deep coupling beams was proposed. The results show that the shear force is mainly transmitted by a strut-and-tie mechanism composed of three types of inclined concrete struts, vertical reinforcement ties and nodes. The influence of span-to-depth ratio on shear capacity is mainly due to the change of inclination angle of main inclined struts. The increasing of concrete compressive strength or volume fraction of steel fiber can improve the shear capacity of SFRC deep coupling beams mainly by enhancing the bearing capacity of compressive struts or tensile strength of the vertical tie. The proposed calculation method is verified using experimental data, and comparative results show that the prediction values agree well with the test ones.

Cyclic behaviour of concrete encased steel (CES) column-steel beam joints with concrete slabs

  • Chu, Liusheng;Li, Danda;Ma, Xing;Zhao, Jun
    • Steel and Composite Structures
    • /
    • 제29권6호
    • /
    • pp.735-748
    • /
    • 2018
  • In this paper, the cyclic behavior of steel beam-concrete encased steel (CES) column joints was investigated experimentally and numerically. Three frame middle joint samples with varying concrete slab widths were constructed. Anti-symmetrical low-frequency cyclic load was applied at two beam ends to simulate the earthquake action. The failure modes, hysteretic behavior, ultimate load, stiffness degradation, load carrying capacity degradation, displacement ductility and strain response were investigated in details. The three composite joints exhibited excellent seismic performance in experimental tests, showing high load-carrying capacity, good ductility and superior energy dissipation ability. All three joint samples reached their ultimate loads due to shear failure. Numerical results from ABAQUS modelling agreed well with the test results. Finally, the effect of the concrete slab on ultimate load was analyzed through a parametric study on concrete strength, slab thickness, as well as slab width. Numerical simulation showed that slab width and thickness played an important role in the load-carrying capacity of such joints. As a comparison, the influence of concrete grade was not significant.

Partially restrained beam-column weak-axis moment connections of low-rise steel structures

  • Lim, Woo-Young;Lee, Dongkeun;You, Young-Chan
    • Structural Engineering and Mechanics
    • /
    • 제76권5호
    • /
    • pp.663-674
    • /
    • 2020
  • In this study, partially restrained beam-column moment joints in the weak-axis direction were examined using three large-scale specimens subject to cyclic loading in order to assess the seismic resistance of the joints of low-rise steel structures and to propose joint details based on the test results. The influence of different number of bolts on the moment joints was thoroughly investigated. It was found that the flexural capacity of the joints in the direction of weak axis was highly dependent on the number of high-tension bolts. In addition, even though the flexural connections subjected to cyclic loading was perfectly designed in accordance with current design codes, severe failure mode such as block shear failure could occur at beam flange. Therefore, to prevent excessive deformation at bolt holes under cyclic loading conditions, the holes in beam flange need to have larger bearing capacity than the required tensile force. In particular, if the thickness of the connecting plate is larger than that of the beam flange, the bearing capacity of the flange should be checked for structural safety.

충전절리면의 미끄러짐특성에 관한 연구 (A Study on the Sliding Characteristics of Infilling-joint Surface)

  • 이정엽;박영목;김재석;구호본;백용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.499-502
    • /
    • 2003
  • The purpose of this study is to understand the sliding characteristics of the infilling-joint surface using the new devised shear test apparatus with changeable slope for the original infilling materials and the infilling materials experienced cyclic freezing-thawing processes. Three types of the mother rock classified as the igneous rock, the metamorphic rock and the sedimentary rock and the infilling materials were collected for laboratory test. The cohesion according to the slope change of the rock joint shows large variation within ${\pm}$5 degrees but the internal friction angle shows appears the linear decreasing tendency. It is confirmed that the affecting factor of slope change of rock joint at the behavior of rock mass is larger than that of the infilling thickness. Test results show that the cohesion and the internal friction angle in 100 times of cyclic freezing-thawing processes are decreased about 50 percent compared with original one. A further study using various infillings materials would lead to a better understanding of the failure mechanism of rock mass by slope change of rock joint.

  • PDF

보강상세에 따른 RC 전단벽과 강재 보 전단접합부의 비탄성 거동 (Inelastic behavior of RC shear wall and steel girder shear connection on reinforcement details)

  • 송한범;이정한;양원직;강대언;이경훈;이원호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.138-141
    • /
    • 2006
  • Shear wall-frame system is one of the most, if not the most, popular system for resisting lateral loads. The core is the primary lateral load-resisting systems, the perimeter frame is designed for gravity loads, and the connection between perimeter frame and core is generally a shear connection. Specially, single plate shear connection have gained considerable popularity in recent years due to their ease of fabrication and erection. Single plate shear connection should be designed to satisfy the dual criteria of shear strength and rotational ductility. An experimental program was undertaken to evaluate seismic behavior of single plate shear connection. The main test variable is the reinforcing detail of connection. Through the experimental program, the cyclic behavior of typical and reinforcing single plate shear connection was established.

  • PDF

절곡형 전단보강근을 사용한 슬래브-기둥 접합부의 이력 거동 (Hysteretic Behavior of Slab-Column Joint Using Bended Type Shear Reinforcement)

  • 이현호;이도범;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권3호
    • /
    • pp.211-218
    • /
    • 2006
  • 본 연구에서는 거주형 무량판 구조의 뚫림 전단을 방지하기 위한 연속 절곡된 전단 보강근을 개발하였다. 이를 적용한 슬래브-기둥 접합부에 있어 개발 전단 보강근의 뚫림 전단 성능을 평가하기 위하여, 구조 성능 실험을 수행하였다. 실험 변수는 전단보강근이 없는 경우, 개발 전단보강근을 사용한 경우, 헤드 스터드를 사용한 경우이다. 수평하중에 대한 저항성능을 평가하기 위하여 일정축력하에서의 이력 하중 실험을 수행하였다. 실험결과는 전체 변위 및 접합부 강도 등으로 평가되었다. 이러한 결과로부터, 개발된 전단보강근이 층간변위비 거동에 있어 우수한 성능을 보유함을 확인할 수 있었다.

철근콘크리트 전단벽의 접합방식과 대각보강에 따른 내진성능 평가 및 개선 (Improvement and Evaluation for Seismic Resistant Capacity of Reinforced Concrete Shear wall with Connection Types and Diagonal Reinforcement)

  • 신종학;하기주;안준석;주정준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.139-147
    • /
    • 1999
  • Six reinforced concrete shear wall, constructured with fully rigid, slit, and infilled types, were tested under both vertical and cyclic loadings. Experimental programs were carried out to evaluate the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility, under load reversals. All the specimens were modeled in one-third scale size. Based on the test results, the following conclusions can be made. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crushing due to slippage prevention of boundary region and reduction of diagonal tension rathar than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by l.14 times and l.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF

스틸하우스 전단벽체의 내진성능평가 (Evaluation of Seismic Performance on Shear Walls in Steel House)

  • 이재석;이승은;홍건호;김원기
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.65-72
    • /
    • 2002
  • 최근의 건축물 내진 설계 추세에 맞추어, 박판의 냉간성형강으로 제작되는 스틸하우스 전단벽체의 내진 성능을 평가하였다. 시험체는 브레이싱의 종류에 따라 변수를 두었다. 반복가력의 결과로는 에너지소산 능력을 살펴보았는데, 브레이싱 부재로 형강을 사용한 시험체가 판재를 사용한 시험체 보다 우수하였다. 또한, 유사동적실험을 통해서는 면재를 사용한 전단벽체 보다. 스틸하우스 전단벽체 중 하나인 X-브레이싱 형태와 유사한 X2SPCH의 내진성능이 비교적 우수함이 판명되었다.

탄소섬유쉬트로 전단보강한 RC 기둥의 이력성능평가에 관한 실험적 연구 (An Experimental Study on the Hysteretic Capacity Evaluation of the Shear-Strengthened RC Column with Carbon Fiber Sheet)

  • 이현호;구은숙
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.750-755
    • /
    • 1999
  • When the RC frame structures subjected to the seismic load, brittle shear failure of vertical members induces brittle collapse of whole structures. Failure mechanism like this is not desirable. So shear strengthening method to avoid this failure mechanism is needed. Recently, strengthening method using continuous fiber sheet is studied and used widely which have high elastic and high strength characteristics. In this study, RC columns which is strengthened by carbon fiber sheet in the form of tape or whole sheet were tested under the cyclic load. The parameter of this test is the amount of strengthening. As the amount of strengthening increase, strength, ductility and energy capacity increase. The failure mode of test results are shear and bond-split failure.

  • PDF