• 제목/요약/키워드: cyclic humidity

검색결과 34건 처리시간 0.027초

건습이 반복되는 환경하의 해양콘크리트 구조물에 대한 염소이온 침투 해석 (Analysis of Chloride Ion Penetraion for Marine Concrete Structure with Cyclic Humidity Environment)

  • 한상훈
    • Ocean and Polar Research
    • /
    • 제26권1호
    • /
    • pp.43-50
    • /
    • 2004
  • The diffusion model, which considers diffusion and sorption, is proposed. The FEM program developed on the basis of the diffusion model provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

항만 콘크리트 구조물의 현장환경변화에 따른 염소이온 침투해석 (Analysis of Chloride Ion Penetration for Harbor Concrete Structure with In-situation Environment)

  • 한상훈;장인성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.225-228
    • /
    • 2004
  • In order to estimate the chloride ion penetration, the model, which considers diffusion and sorption, is proposed on the basis of Finite Element Method (FEM). The FEM program provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages and constant outer humidity, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in-situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

  • PDF

환경변화에 강한 골판지 개발을 위한 기초연구(제1보) (The preliminary study of developing strong corrugated box board against aggravated service condition(I))

  • 서영범;오영순
    • 펄프종이기술
    • /
    • 제30권1호
    • /
    • pp.29-43
    • /
    • 1998
  • This study was to investigate the effect of .compressive load and cyclic humidity(2$0^{\circ}C$, 65% and 90% RH) on the physical and mechanical properties of corrugated board. Corrugated boards in the study were under compressive load and under cyclic humidity, and their properties were compared to those without load. Results were summarized as follows ; 1 Statistically significant correlation was shown between the ring crush of the boards and the compressive strength of cylinder specimen made from the boards. So we could study the compressive behavior of board with cylinder specimen. 2. The boards under the compressive load increased their moisture content and thickness much more than those without load both in constant and in cyclic RH. 3. The compressive and tensile strength of board samples were inversely and closely proportional to the sheet moisture content regardless of their load and humidity history. 4. The moisture content did not show any significant proportionality to the change of burst strength of boards within this experiment. 5. Board reconditioning in standard condition led to the recovery of the strength loss that had occurred under various load and humidity condition. 6. The handsheets prepared from the boards that had experienced compressive load and cyclic humidity, and those with no-load and 65% RH did not show any significant difference in strength properties. No physical damage or load-carrying properties of the wood fiber were observed by the compressive load and cyclic humidity history.

  • PDF

Comparison of Dynamic Sorption and Hygroexpansion of Wood by Different Cyclic Hygrothermal Changing Effects

  • Yang, Tiantian;Ma, Erni
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권2호
    • /
    • pp.191-203
    • /
    • 2016
  • To investigate the dynamic sorptive and hygroexpansive behaviors of wood by different cyclic hygrothermal changing effects, poplar (populus euramericana Cv.) specimens, were exposed to dynamic sorption processes where relative humidity (RH) and temperature changed simultaneously in sinusoidal waves at 75-45% and $5-35^{\circ}C$ (condition A) and where RH changed sinusoidally at 75-45% but temperature was controlled at $20^{\circ}C$ (condition B), both for three cyclic periods of 1, 6, and 24 h. Moisture and dimensional changes measured during the cycling gave the following results: Moisture and transverse dimensional changes were generally sinusoidal. Moisture and dimensional amplitude increased with increasing cyclic period but all were lower for thicker specimens. The amplitude ratio of condition A to condition B ranged from 1.0 to 1.6 with the maximum value of 1.57 occurring at the shortest cyclic period, not as much as expected. T/R increased as cyclic period increased or specimen thickness decreased. T/R from condition B was weaker than that from condition A. Sorption and swelling hysteresis existed in both conditions. Sorption hysteresis was negatively related to cyclic period but in positive correlation with specimen thickness. Sorption hysteresis was found more obvious in condition B, while moisture sorption coefficient and humidity expansion coefficient showed the opposite results.

저습도 사이클 조건에서의 라이너지와 골판지의 물성 (Physical Properties of Linerboard and Corrugated Fiberboard at the Cyclic Condition of Low Humidity)

  • 윤혜정;이학래;진성민;최익선
    • 펄프종이기술
    • /
    • 제39권2호
    • /
    • pp.38-44
    • /
    • 2007
  • The hygroscopic property of paper is important for convertability and end use performance. When the board and corrugated fiberboard are exposed to low relative humidity, a trouble of score (or crease) cracking could occur. In this study, we evaluated the moisture content and mechanical properties of linerboard and corrugated board at the cyclic condition of low humidity to prevent a score crack trouble. As the relative humidity decreased from 50% to 38% and 25%, the moisture content of linerboard decreased about 7% to 6% and 4%. At low humidity, most of mechanical properties were improved except for strain. The linerboard exposed at 25% RH showed a remarkable reduction of strain by 11%. At the same relative humidity, linerboard and corrugated fiberboard showed the different property values depending on moisture hysteresis.

현장 항만 콘크리트 구조물에 대한 염소이온 침투 해석 (Analysis of Chloride ion Penetration for In-Situation Harbor Concrete Structures)

  • 한상훈
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.751-760
    • /
    • 2005
  • 본 논문에서는 확산과 수분이동에 의한 침투를 함께 고려할 수 있는 염소이온침투 모델을 제시하고 이를 바탕으로 유한요소 프로그램을 개발한다. 개발된 프로그램을 이용하여 습도와 온도가 연속적으로 변화하는 현장상태에 대한 염소이온 침투 해석을 수행한다. 해석과정으로 먼저 수분확산해석을 수행한다. 이 해석에 의한 각 유한요소의 상대습도를 바탕으로 염소이온 침투해석을 위한 재료상수를 구한다. 이러한 재료상수를 이용하여 염소이온 침투해석을 수행하게 된다. 각 유한요소들은 시간과 재령에 따라 연속적으로 변화하는 재료상수 값을 가지게 된다. 내외부의 상대습도 차이가 크면 수분이동에 의한 염소이온 침투의 영향이 커지지만 내외부의 상대습도의 차이는 수분확산에 의해서 재령에 따라 감소하므로 수분이동에 의한 염소이온 침투의 영향은 재령에 따라 감소한다. 반복 습윤은 수분이동에 의한 염소이온 침투의 영향을 증가시켜 철근 주위의 염소이온 농도를 커지게 한다. 현장상황과 같이 건습의 반복이 장기적으로 발생하게 되면 수착과 확산을 함께 고려한 염소이온 침투량이 수분이동을 고려하지 않은 염소이온 침투량보다 매우 크다. 따라서, 항만 콘크리트 구조물에 대한 염소이온 침투해석을 장기재령동안 수행할 경우에는 수분이동 메커니즘을 포함한 수치 모델링을 바탕으로 건습의 반복을 고려하여 해석을 수행하는 것이 해석의 오차를 줄일 수 있을 것이다.

$CaZrO_3$ 세라믹스의 감습 특성 (The humidity sensitive characteristics of $CaZrO_3$ ceramics)

  • 육재호;김용운
    • 전자공학회논문지 IE
    • /
    • 제43권3호
    • /
    • pp.1-5
    • /
    • 2006
  • 고상반응법을 이용하여 $CaZrO_3$ 습도센서를 제작하였으며 그의 감습특성에 대하여 연구하였다. 습도센서의 임피던스는 상대습도가 증가함에 따라 감소하며 감습도는 주파수에 의존하였다. 센서의 감습도는 열처리에 안정되고 흡습 탈습에 따른 히스테리시스 현상이 거의 나타나지 않았으며 전기전도 활성화에너지는 흡습에 따라 감소하였다.

Dimensional Responses of Wood Under Cyclical Changing Temperature at Constant Relative Humidity

  • Yang, Tiantian;Ma, Erni;Shi, Yi
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.539-547
    • /
    • 2015
  • To investigate dimensional responses of wood under dynamic temperature condition, poplar (populous euramericana Cv.) specimens, 20 mm in radial (R) and tangential (T) directions with two thicknesses of 4 and 10 mm along the grain, were exposed to cyclic temperature changes in square wave between $25^{\circ}C$ and $40^{\circ}C$ at 60% relative humidity (RH) for three different cycling periods of 6 h, 12 h and 24 h. R and T dimensional changes measured during the cycling gave the following results: 1) Transverse dimensional changes of the specimens were generally square but at an opposite phase and lagged behind the imposed temperature changes. The phase lag was inversely correlated with cycling period, but positively related to specimen thickness, while the response amplitude was directly proportional to cycling period, but in a negative correlation with specimen thickness. 2) The specimens showed swelling hysteresis behavior. The heat shrinkage coefficient (HSC) became greater as cycling period increased or specimen thickness decreased. 3) Dimensional changes of the specimens produced deformation accumulation during repeated adsorption and desorption. The deformation accumulating ratio decreased with an increase in cycling period and specimen thickness. 4) Wood suffered 1.5 times as many dimensional changes per unit temperature variation as per unit humidity variation, and this deformation behaved even more seriously under static condition.

층류유동 저습도 조건에서의 평행평판형 냉각판 서리성장 실험 (Experiment of frost growth on the parallel plates in the condition of laminar and low humidity)

  • 한흥도;노승탁
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.440-447
    • /
    • 1999
  • The frosting characteristics on the vertical parallel plates with three cooling plates were experimentally investigated. The experimental parameters were the cooling plate temperature, the air humidity, the air temperature, the air Reynolds number, and the location. The frosting conditions were limited to air temperatures from 10 to $15^{\circ}C$ , air Reynolds numbers from 1600 to 2270, air humidity ratios from 0.00275 to 0.0037kgw/kga and cooling plate temperatures from -10 to $-20^{\circ}C$. Frost growth and density toward the front of the plate were more thick and dense than toward the rear. Frost growth increased with decreasing plate temperature and increasing humidity. In the conditions of the laminar flow, dew point below $0^{\circ}C$and non-cyclic frosting period, frost thickness increased with increasing air temperature. The reason of increasing frost thickness with increasing air temperature was sublimation-ablimation process. The average growth thickness along the locations showed little dependence on the Reynolds numbers.

  • PDF

Cut Edge Corrosion of Painted Zn and 55%Al-Zn Coated Steels under Alternate Wetting and Drying

  • Nishikata, A.;Tsuda, T.;Tsuru, T.
    • Corrosion Science and Technology
    • /
    • 제9권1호
    • /
    • pp.34-38
    • /
    • 2010
  • Electrochemical study on cut edge corrosion of prepainted Zn coated (GI) and 55%Al-Zn coated (GL) steels has been performed in wet-dry cyclic conditions. Maximum width of delaminated polymer coating from the cut edge for GI and GL specimens was evaluated under wet-dry cyclic conditions. The cyclic tests were carried out for 1000 h by changing of relative humidity, where the salt of NaCl was deposited on the specimen every 48 h. The cut edge corrosion test under NaCl deposit indicated that the delamination of the GL specimen progresses at a higher rate than the GI. The electrochemical corrosion monitoring was also performed under condition of alternate exposure to immersion in NaCl solution and drying at 60%RH and $25^{\circ}C$. On the basis of the results of the delamination tests and electrochemical measurements, the mechanism of cut edge corrosion for GI and GL were discussed.