• Title/Summary/Keyword: cut-off

Search Result 2,202, Processing Time 0.029 seconds

Detection of Incidental Prostate Cancer or Urothelial Carcinoma Extension in Urinary Bladder Cancer Patients by Using Multiparametric MRI: A Retrospective Study Using Prostate Imaging Reporting and Data System Version 2.0 (방광암 환자의 다중 매개 자기공명영상에서 우연히 발견된 전립선암 또는 요로상피세포암종의 전립선 침범의 검출: 전립선 이미징 보고 및 데이터 시스템 버전 2.0을 사용한 후향적 연구)

  • Sang Eun Yoon;Byung Chul Kang;Hyun-Hae Cho;Sanghui Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.610-619
    • /
    • 2020
  • Purpose The study aimed to investigate the role of Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) in predicting incidental prostate cancer (PCa) or urothelial carcinoma (UCa) extension in urinary bladder (UB) cancer patients. Materials and Methods A total of 72 UB cancer patients who underwent radical cystoprostatectomy and 3 Tesla multiparametric MRI before surgery were enrolled. PI-RADS v2 ratings were assigned by two independent radiologists. All prostate specimens were examined by a single pathologist. We compared the multiparametric MRI findings rated using PI-RADS v2 with the pathologic data. Results Of the 72 UB cancer patients, 29 had incidental PCa (40.3%) and 20 showed UCa extension (27.8%), with an overlap for 3 patients. With a score of 4 as the cut-off value for predicting incidental PCa, the diagnostic accuracy was 65.3%, specificity was 90.7%, and positive predictive value (PPV) was 66.7%. The diagnostic accuracy for incidental UCa extension was 47.2%, specificity was 92.3%, and PPV was 83.3%. Conclusion Despite the low diagnostic accuracy, the PPV and specificity were relatively high. Therefore, PI-RADS v2 scores of 1, 2, or 3 may help exclude the probability of incidental PCa or UCa extension.

Artificial Intelligence-Based Identification of Normal Chest Radiographs: A Simulation Study in a Multicenter Health Screening Cohort

  • Hyunsuk Yoo;Eun Young Kim;Hyungjin Kim;Ye Ra Choi;Moon Young Kim;Sung Ho Hwang;Young Joong Kim;Young Jun Cho;Kwang Nam Jin
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.1009-1018
    • /
    • 2022
  • Objective: This study aimed to investigate the feasibility of using artificial intelligence (AI) to identify normal chest radiography (CXR) from the worklist of radiologists in a health-screening environment. Materials and Methods: This retrospective simulation study was conducted using the CXRs of 5887 adults (mean age ± standard deviation, 55.4 ± 11.8 years; male, 4329) from three health screening centers in South Korea using a commercial AI (Lunit INSIGHT CXR3, version 3.5.8.8). Three board-certified thoracic radiologists reviewed CXR images for referable thoracic abnormalities and grouped the images into those with visible referable abnormalities (identified as abnormal by at least one reader) and those with clearly visible referable abnormalities (identified as abnormal by at least two readers). With AI-based simulated exclusion of normal CXR images, the percentages of normal images sorted and abnormal images erroneously removed were analyzed. Additionally, in a random subsample of 480 patients, the ability to identify visible referable abnormalities was compared among AI-unassisted reading (i.e., all images read by human readers without AI), AI-assisted reading (i.e., all images read by human readers with AI assistance as concurrent readers), and reading with AI triage (i.e., human reading of only those rendered abnormal by AI). Results: Of 5887 CXR images, 405 (6.9%) and 227 (3.9%) contained visible and clearly visible abnormalities, respectively. With AI-based triage, 42.9% (2354/5482) of normal CXR images were removed at the cost of erroneous removal of 3.5% (14/405) and 1.8% (4/227) of CXR images with visible and clearly visible abnormalities, respectively. In the diagnostic performance study, AI triage removed 41.6% (188/452) of normal images from the worklist without missing visible abnormalities and increased the specificity for some readers without decreasing sensitivity. Conclusion: This study suggests the feasibility of sorting and removing normal CXRs using AI with a tailored cut-off to increase efficiency and reduce the workload of radiologists.

Quality of Radiomics Research on Brain Metastasis: A Roadmap to Promote Clinical Translation

  • Chae Jung Park;Yae Won Park;Sung Soo Ahn;Dain Kim;Eui Hyun Kim;Seok-Gu Kang;Jong Hee Chang;Se Hoon Kim;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.77-88
    • /
    • 2022
  • Objective: Our study aimed to evaluate the quality of radiomics studies on brain metastases based on the radiomics quality score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) checklist, and the Image Biomarker Standardization Initiative (IBSI) guidelines. Materials and Methods: PubMed MEDLINE, and EMBASE were searched for articles on radiomics for evaluating brain metastases, published until February 2021. Of the 572 articles, 29 relevant original research articles were included and evaluated according to the RQS, TRIPOD checklist, and IBSI guidelines. Results: External validation was performed in only three studies (10.3%). The median RQS was 3.0 (range, -6 to 12), with a low basic adherence rate of 50.0%. The adherence rate was low in comparison to the "gold standard" (10.3%), stating the potential clinical utility (10.3%), performing the cut-off analysis (3.4%), reporting calibration statistics (6.9%), and providing open science and data (3.4%). None of the studies involved test-retest or phantom studies, prospective studies, or cost-effectiveness analyses. The overall rate of adherence to the TRIPOD checklist was 60.3% and low for reporting title (3.4%), blind assessment of outcome (0%), description of the handling of missing data (0%), and presentation of the full prediction model (0%). The majority of studies lacked pre-processing steps, with bias-field correction, isovoxel resampling, skull stripping, and gray-level discretization performed in only six (20.7%), nine (31.0%), four (3.8%), and four (13.8%) studies, respectively. Conclusion: The overall scientific and reporting quality of radiomics studies on brain metastases published during the study period was insufficient. Radiomics studies should adhere to the RQS, TRIPOD, and IBSI guidelines to facilitate the translation of radiomics into the clinical field.

Non Face-to-Face Treatment and Not-informed Medication to Persons with Mental Disorders (정신질환자에 대한 비대면진료 및 비고지투약 -치료적 대화의 복원을 위한 모색적 고찰-)

  • Jung, Sangmin
    • The Korean Society of Law and Medicine
    • /
    • v.25 no.1
    • /
    • pp.149-192
    • /
    • 2024
  • People with mental illness are generally either unaware of their illness or unwilling to voluntarily seek treatment, which makes treatment difficult and the pain mainly passed on to their families. Accordingly, non-face-to-face treatment, in which the patient is diagnosed by interviews with the family and unannounced medication, in which medication is secretly administered through the family, can be performed, and this has been considered a necessary evil. Even considering realistic aspects such as the special nature of mental health care and families' suffer, not-informed treatment without consent violates not only medical laws, but also human rights of mentally ill patients. Above all, if the patient finds out about this late, the trust between the patient, family, and doctor is completely broken, and a treatment is absolutely refused. Japan's Chiba decision, which presents exceptional conditions for allowance might be a solution. However, it would not be a right solution, considering that it could lead to long-term unannounced medication and completely cut off treatment through therapeutic dialogue. Ultimately, it need to approach this problem and seek alternatives through restoration of therapeutic dialogue.

Two-Dimensional Shear Wave Elastography Predicts Liver Fibrosis in Jaundiced Infants with Suspected Biliary Atresia: A Prospective Study

  • Huadong Chen;Luyao Zhou;Bing Liao;Qinghua Cao;Hong Jiang;Wenying Zhou;Guotao Wang;Xiaoyan Xie
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.959-969
    • /
    • 2021
  • Objective: This study aimed to evaluate the role of preoperative two-dimensional (2D) shear wave elastography (SWE) in assessing the stages of liver fibrosis in patients with suspected biliary atresia (BA) and compared its diagnostic performance with those of serum fibrosis biomarkers. Materials and Methods: This study was approved by the ethical committee, and written informed parental consent was obtained. Two hundred and sixteen patients were prospectively enrolled between January 2012 and October 2018. The 2D SWE measurements of 69 patients have been previously reported. 2D SWE measurements, serum fibrosis biomarkers, including fibrotic markers and biochemical test results, and liver histology parameters were obtained. 2D SWE values, serum biomarkers including, aspartate aminotransferase to platelet ratio index (APRi), and other serum fibrotic markers were correlated with the stages of liver fibrosis by METAVIR. Receiver operating characteristic (ROC) curves and area under the ROC (AUROC) curve analyses were used. Results: The correlation coefficient of 2D SWE value in correlation with the stages of liver fibrosis was 0.789 (p < 0.001). The cut-off values of 2D SWE were calculated as 9.1 kPa for F1, 11.6 kPa for F2, 13.0 kPa for F3, and 15.7 kPa for F4. The AUROCs of 2D SWE in the determination of the stages of liver fibrosis ranged from 0.869 to 0.941. The sensitivity and negative predictive value of 2D SWE in the diagnosis of ≥ F3 was 93.4% and 96.0%, respectively. The diagnostic performance of 2D SWE was superior to that of APRi and other serum fibrotic markers in predicting severe fibrosis and cirrhosis (all p < 0.005) and other serum biomarkers. Multivariate analysis showed that the 2D SWE value was the only statistically significant parameter for predicting liver fibrosis. Conclusion: 2D SWE is a more effective non-invasive tool for predicting the stage of liver fibrosis in patients with suspected BA, compared with serum fibrosis biomarkers.

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

  • Yuehua Li;Mingyuan Yuan;Mengmeng Yu;Zhigang Lu;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.621-630
    • /
    • 2019
  • Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48-88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7-6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.

Beak Trimming Methods - Review -

  • Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.11
    • /
    • pp.1619-1637
    • /
    • 2000
  • A review was undertaken to obtain information on the range of beak-trimming methods available or under development. Beak-trimming of commercial layer replacement pullets is a common yet critical management tool that can affect the performance for the life of the flock. The most obvious advantage of beak-trimming is a reduction in cannibalism although the extent of the reduction in cannibalism depends on the strain, season, and type of housing, flock health and other factors. Beak-trimming also improves feed conversion by reducing food wastage. A further advantage of beak-trimming is a reduction in the chronic stress associated with dominance interactions in the flock. Beak-trimming of birds at 7-10 days is favoured by Industry but research over last 10 years has shown that beak-trimming at day-old causes the least stress on birds and efforts are needed to encourage Industry to adopt the practice of beak-trimming birds at day-old. Proper beak-trimming can result in greatly improved layer performance but improper beak-trimming can ruin an other wise good flock of hens. Re-trimming is practiced in most flocks, although there are some flocks that only need one trimming. Given the continuing welfare scrutiny of using a hot blade to cut the beak, attempts have been made to develop more welfare friendly methods of beak-trimming. Despite the developments in design of hot blade beak-trimmers the process has remained largely unchanged. That is, a red-hot blade cuts and cauterises the beak. The variables in the process are blade temperature, cauterisation time, operator ability, severity of trimming, age of trimming, strain of bird and beak length. This method of beak-trimming is still overwhelmingly favoured in Industry and there appears to be no other alternative procedures that are more effective. Sharp secateurs have been used trim the upper beak of both layers and turkeys. Bleeding from the upper mandible ceases shortly after the operation, and despite the regrowth of the beak a reduction of cannibalism has been reported. Very few differences have been noted between behaviour and production of the hot blade and cold blade cut chickens. This method has not been used on a large scale in Industry. There are anecdotal reports of cannibalism outbreaks in birds with regrown beaks. A robotic beak-trimming machine was developed in France, which permitted simultaneous, automated beak-trimming and vaccination of day-old chicks of up to 4,500 chickens per hour. Use of the machine was not successful because if the chicks were not loaded correctly they could drop off the line, receive excessive beak-trimming or very light trimming. Robotic beak-trimming was not effective if there was a variation in the weight or size of chickens. Capsaicin can cause degeneration of sensory nerves in mammals and decreases the rate of beak regrowth by its action on the sensory nerves. Capsaicin is a cheap, non-toxic substance that can be readily applied at the time of less severe beak-trimming. It suffers the disadvantage of causing an extreme burning sensation in operators who come in contact with the substance during its application to the bird. Methods of applying the substance to minimise the risk to operators of coming in contact with capsaicin need to be explored. A method was reported which cuts the beaks with a laser beam in day-old chickens. No details were provided on the type of laser used, or the severity of beak-trimming, but by 16 weeks the beaks of laser trimmed birds resembled the untrimmed beaks, but without the bill tip. Feather pecking and cannibalism during the laying period were highest among the laser trimmed hens. Currently laser machines are available that are transportable and research to investigate the effectiveness of beak-trimming using ablasive and coagulative lasers used in human medicine should be explored. Liquid nitrogen was used to declaw emu toes but was not effective. There was regrowth of the claws and the time and cost involved in the procedure limit the potential of using this process to beak-trim birds.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF

The ages and stages questionnaire: screening for developmental delay in the setting of a pediatric outpatient clinic (ASQ :소아과외래에서의 발달지연 선별검사)

  • Kim, Eun Young;Sung, In Kyung
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.11
    • /
    • pp.1061-1066
    • /
    • 2007
  • Purpose : Early identification of developmental disabilities allows intervention at the earliest possible point to improve the developmental potential. The Ages and Stages Questionnaire (ASQ), a parent- completed questionnaire, can be used as a substitute for formal screening tests. The purpose of this study was to evaluate the validity of the Korean version of the ASQ (K-ASQ) as a screening tool for detecting developmental delay of young Korean children in the setting of a busy pediatric outpatient clinic. Methods : Parents completed the K-ASQ in the waiting room of the pediatric outpatient clinic of St. Mary's Hospital, Catholic University Medical College. Out of 150 completed the ASQ, 67 who were born term and had no previous diagnosis of developmental delay, congenital anomalies, or neurological abnormalities were enrolled. The cut-off values of less than 2 standard deviations (SD) below the mean for the ASQ were used to define a "fail", and children who failed in one or more domains tested were classified as "screen-positive". Diagnosis of developmental delay was made when the developmental indices fell below -1 SD of the Bayley Scales of Infant Development-II. Results : (1) The mean age of children was $16.4{\pm}7.4$ months. Ten children (14.9%) were small-for- gestational age infants. The mean birth weight and gestational age were $3.1{\pm}0.6kg$ and $38.8{\pm}1.4$ weeks. Nine children (13.4%) were twins and 33 (49.0%) were male. The mean maternal education in years was $13.6{\pm}2.4$, and 31.3% had full-time jobs. The time for completing the ASQ was $10.2{\pm}3.0$ minutes. (2) Seventeen children (25.4%) were classified as screen-positive, four of them were delayed in development. Among eight children diagnosed with developmental delay, four were screen-positive and the other four were screen-negative by the ASQ. (3) The test characteristics of the ASQ were as follows: sensitivity (50.0%); specificity (78.0%); positive predictive value (23.5%); negative predictive value (92.0%). Conclusion : The high negative predictive value of the K-ASQ supports its use as a screening tool for developmental delay in the setting of a pediatric outpatient clinic.