• Title/Summary/Keyword: current standard

Search Result 3,825, Processing Time 0.029 seconds

A Study on the Improvement of Aquaculture Certification System to Meet Greater Retailer's Supplier Assesment Requirement (대형마트 공급자평가에 대응하기 위한 수산양식장 인증제도 개선에 관한 연구)

  • Seo, Jong-Seok;Seo, Won-Chul;Ock, Young-Seok
    • The Journal of Fisheries Business Administration
    • /
    • v.45 no.1
    • /
    • pp.33-47
    • /
    • 2014
  • The purpose of this study is to find method to meet the greater retailer's supplier assessment requirement So, this study analyze the greater retailer's requirement for supplier assesment and research global standard which is used instead of supplier assessment requirement that is recognized by global retailers initiative. Next, this study analyze domestic aquaculture certification requirement and compare the global standard with the domestic requirement by using The Most Similar Systems Design. As a result, this comparing has founded all of two domestic certifications are similar to global standard's Good Aquaculture Practice module but those are a little bit different from System Element module. Therefore, this study suggest tree alternative. First, make up for the weak points in the current domestic aquaculture certification system. Second, the introduction of global aquaculture management system certification as supporting by government. Third, development of new standard in accordance with global food standard. This study has major implications for research into development of domestic aquaculture standard.

Development of a Delivery Workload Management System for Measuring and Balancing Standard Workload of Mailmen (집배부하량 산정 및 평준화를 위한 집배부하 관리시스템 개발)

  • Cha, Chun-Nam;Sun, Ji-Ung;Park, Moon-Sung
    • IE interfaces
    • /
    • v.24 no.4
    • /
    • pp.435-446
    • /
    • 2011
  • Performance measures play a critical role in formulating mail delivery strategies and evaluating actual results. Nevertheless, the existing method and corresponding system to determine the standard workloads of mailmen is developed without careful consideration of real delivery environments and various requirements of mailmen. Hence, the current system is insufficient for optimal management of workloads and shows substantial gaps when compared to the results of actual work-site. This study considers how to improve the current workload management system of mailmen. We first performed the as-is analysis of the mail delivery service and then developed a prototype of advanced delivery workload management system. The to-be system consists of five subsystems which can be grouped into three categories; master data management, workloads management, performance analysis. Our results can be a valuable guide for the development of real system for measuring and balancing the workloads of mailmen.

A Reliability Verification of Screening Time Prediction Reporting of 'Cine-Hangeul'

  • Jeon, Byoung-Won
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.141-146
    • /
    • 2020
  • Cine-Hangeul is a program that can predict the running time of a movie based on the screenplay before production. This paper seeks to verify the prediction reporting function of Cine-Hangeul, which is the standard Korean screenplay format. Moreover, this paper presents a method to increase the accuracy of the Cine-Hangeul reporting function. The objective of this paper is to offer a correction method based on scientific evidence because the current Cine-Hangeul reporting function has many errors. The verification process for five scenarios and movies confirmed that the default setting value of Cine- Hangeul's screening time prediction reporting was many errors. Cine-Hangeul analyzes the amount of textual information to predict the time of the scene and the time of the dialogue and helps predict the total time of the movie. Therefore, if a certain amount of text information is not available, the accuracy is unreliable. The current Cine-Hangeul prediction report confirms that the efficiency is high when the scenario volume is about 90 to 100 pages. As a result, prediction of screening time by Cine-Hangeul, a Korean scenario standard format program, confirmed the verification that it could secure the same level of reliability as the actual screening time by correcting the reporting settings. This verification also affirms that when applying about 50 percent of the basic set of screening time reporting, it is almost identical to the screening time.

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

A Tentative Study on Sizing System for Children's Shoes (아동화의 치수규격설계를 위한 탐색적 연구)

  • Jeon, Eun-Kyung;Kwon, Sook-Hee
    • Korean Journal of Human Ecology
    • /
    • v.16 no.1
    • /
    • pp.173-181
    • /
    • 2007
  • This is a tentative study to provide prototype of sizing system for children's shoes. For this study, 364 elementary school girls from KyungIn and YeongNam areas were participated in the measurement. The results of the analysis on four measurement items related to foot can be summarized as followings: 1. All of the foot related items were increased according to their growth. Especially, foot length, foot width, and toe width showed a high correlation. 2. The result also revealed that the current sizing system can cover only 70.9% of children in measurement, which means that a new sizing system is required. 3. We suggested a new standard size for foot size/foot circumference based on the results above according to current sizing system, and a new standard size for foot circumference/foot width based on ISO standard. The results of this study would be helpful in the design of sizing system of children's shoe if applied with the raw data of the Size Korea recently measured.

A Study on the problems of current National Standard Classification of Science and Technology for National Science and Technology Information System (NTIS 측면에서 본 국가과학기술표준분류 및 호환표의 유용성에 관한 연구)

  • Song, Choong-Han;Seol, Sung-Soo
    • Journal of Korea Technology Innovation Society
    • /
    • v.9 no.3
    • /
    • pp.496-513
    • /
    • 2006
  • Ministry of Science and Technology(MOST) has a plan to establish the National Science and Technology Information System(NTIS). For successful NTIS, there are three pre-standardizations. Standard classification is the one of the three standardizations. In this paper, the validity of current National Standard Classification of Science and Technology(NSCST) is analyzed for three aspects. One is the duplication of NSCST, one another is the high ratio of incorrectness of information changed by mapping table and the last is the incorrectness of the mapping table itself. So for the successful NTIS a new Science and Technology Classicication shoud be considered.

  • PDF

A Study on the Application of the Management System for Records Standard on University Archives: Based on ISO 30301 (대학기록관에서의 기록경영시스템 표준 도입에 관한 연구 - ISO 30301을 중심으로 -)

  • Kim, Cho Rong;Han, Seunghee
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.15 no.2
    • /
    • pp.31-54
    • /
    • 2015
  • This study investigated the applicability of the Management System for Records Standard (ISO 30301) in university archives. To examine the current state of the university archives, we surveyed 57 university archives based on the requirements of ISO 30301. We analyzed the current state of the university archives through survey results and professional interviews. Subsequently, we suggested eight things that need improvement for the adoption of ISO 30301 in university archives.

Design of Variouble Frequency Driver with Semiconductor Switch Temperature for Electronic Ballast (전자식 안정기의 출력반도체 온도에 따른 주파수 가변회로 설계)

  • Choi, Myoung-Ho;Lim, Sung-Hun;Oh, Seong-Keun;Han, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2780-2782
    • /
    • 1999
  • Many electronic ballasts for low pressure discharge lamps as fluorescent lamps are produced and commercialized. However, the electronic ballasts for high pressure lamps are now in progress to because of poor reliability and high cost of production. To obtain the confidence of electronic ballasts, it is necessary to prolong the life time of output switches. A variable frequency driver for inverter switches that can control the magnitude of output current with temperature of switches was designed and simulated. A conditions for circuit design are 22kHz : standard frequency, $100^{\circ}C$: standard temperature, $I_{peak}$ : 0.76A, and $V_{peak}$ : 184V, respectively. By simulation, as the temperature exceed a standard temperature, the frequency was increased up to 40kHz. However, the current and voltage that flow through switchs were decreased to 0.507A and 121V at $150^{\circ}C$, respectively.

  • PDF

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF