• Title/Summary/Keyword: cumulative proportional ratio

Search Result 26, Processing Time 0.026 seconds

Generating of the same hue population using hue angle and chroma vector (색상각와 채도벡터를 이용한 동일색상의 분광반사 모집단 생성)

  • 유미옥;서봉우;안석출
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.2
    • /
    • pp.1-12
    • /
    • 2000
  • This paper proposes a new algorithm classifing same hues in order toe estimate the spectral reflectance of object from 3 band color image information. To estimate the spectral reflectance of object, the conventional estimation methods are required of 5 or 9 band digital color values. The 5 or 9 band image acquisition systems are required of 5 or 3 times same work for color image acquisition process. To solve the above problems, we propose a new method that can be estimated spectra reflectance estimation of object. The proposed method is to classify same hues corresponding a color stimulus, by using hue angle and chroma vector of a color stimulus. The classified same hues are used as the population corresponding a color stimulus. The range of same hue is estimated by the cumulative proportional ration according to the number of basis function.

  • PDF

Routine Follow-Up Biopsies after Complete Endoscopic Resection for Early Gastric Cancer May Be Unnecessary

  • Lee, Jong-Yeul;Choi, Il-Ju;Cho, Soo-Jeong;Kim, Chan-Gyoo;Kook, Myeong-Cherl;Lee, Jun-Ho;Ryu, Keun-Won;Kim, Young-Woo
    • Journal of Gastric Cancer
    • /
    • v.12 no.2
    • /
    • pp.88-98
    • /
    • 2012
  • Purpose: Local recurrence, due to residual tumor, may occur after endoscopic resection for early gastric cancer. The aims of this study are to evaluate the predictive factors for local recurrence, and suggest an appropriate follow-up biopsy strategy. Materials and Methods: We retrospectively reviewed 396 early gastric cancers from 372 consecutive patients, who underwent endoscopic resection between January 2002 and April 2008. Cumulative recurrence rates were determined by the Kaplan-Meier method, and Cox proportional hazard analysis was used to determine the risk factors for local recurrence. Results: Local recurrence at the endoscopic resection site was found in 17 cases, among the total 396 lesions, during a median follow-up period of 48 months. The 5-year cumulative local recurrence rate was 4.8%. Multivariate analyses determined that tumor involvement at the lateral resection margin [hazard ratio: 35.9; P<0.001], uncheckable lateral resection margin [hazard ratio: 16.8; P<0.001], uncheckable or involved deep resection margin [hazard ratio: 3.76; P=0.047], and piecemeal resection [hazard ratio: 3.95; P=0.007] were associated with local recurrence. If a lesion was positive for any of these risk factors, the 5-year cumulative recurrence rate was 27.0%, while local recurrence was not found in any lesion that lacked these risk factors. Most episodes of recurrence were found during the first or second follow-up endoscopic biopsy at the ulcer scar. Conclusions: Routine follow-up biopsies at the endoscopic resection site might be unnecessary in cases where an early gastric cancer lesion was endoscopically resected en bloc with tumor-free lateral and deep margins.

Application of Proportional Odds Models to the Effects of Removing Dental Plaque in Use of Proxabrush (치간칫솔 사용에 따른 치면세균막 제거효과에 대한 비례오즈모형(proportional odds models) 적용)

  • Kim, Jin-Soo;Kim, Jee-Yun;Jorn, Hong-Suk
    • Journal of dental hygiene science
    • /
    • v.8 no.3
    • /
    • pp.169-173
    • /
    • 2008
  • As a result of analyzing the effects of removing dental plaque according to using proxabrush by using the proportional odds models, targeting patients of practicing oral prophylaxis in juniors for the Department of Dental Hygiene at S university from March 10, 2007 to June 3, 2007, the following conclusions were obtained. 1. The goodness-of-fit in the proportional odds models is 1.2552 whose degree of freedom is 3, and p value is .7398, thereby implying that the proportional odds models are appropriate. And, regarding the effects of removing dental plaque and the independent matter of using proxabrush, as the test on $H_0:{\beta}=0$, the test statistics is 15.5496 whose degree of freedom is 1, and p value is 15.5496. This implies that there is high correlation between the effect of removing dental plaque and the use of proxabrush. 2. ML estimate on $\beta$ in the model can be $\hat{\beta}=1.2493$ (ASE = 0.3207). And, as for the tendency that the response will belong to being very good(this can be expressed to be $Y{\leq}j$) rather than being very bad, the tendency of using proxabrush is higher by the estimated odds ratio exp(1.2493) = 3.49 times than the response of not using proxabrush. 3. As for the estimated response in the proportional odds models, the estimated(cumulative) probability, which the response of using proxabrush is very good and will belong to the good effect of removing dental plaque, is 0.38(0.50).

  • PDF

A conditionally applied neural network algorithm for PAPR reduction without the use of a recovery process

  • Eldaw E. Eldukhri;Mohammed I. Al-Rayif
    • ETRI Journal
    • /
    • v.46 no.2
    • /
    • pp.227-237
    • /
    • 2024
  • This study proposes a novel, conditionally applied neural network technique to reduce the overall peak-to-average power ratio (PAPR) of an orthogonal frequency division multiplexing (OFDM) system while maintaining an acceptable bit error rate (BER) level. The main purpose of the proposed scheme is to adjust only those subcarriers whose peaks exceed a given threshold. In this respect, the developed C-ANN algorithm suppresses only the peaks of the targeted subcarriers by slightly shifting the locations of their corresponding frequency samples without affecting their phase orientations. In turn, this achieves a reasonable system performance by sustaining a tolerable BER. For practical reasons and to cover a wide range of application scenarios, the threshold for the subcarrier peaks was chosen to be proportional to the saturation level of the nonlinear power amplifier used to pass the generated OFDM blocks. Consequently, the optimal values of the factor controlling the peak threshold were obtained that satisfy both reasonable PAPR reduction and acceptable BER levels. Furthermore, the proposed system does not require a recovery process at the receiver, thus making the computational process less complex. The simulation results show that the proposed system model performed satisfactorily, attaining both low PAPR and BER for specific application settings using comparatively fewer computations.

No-Touch Radiofrequency Ablation Using Twin Cooled Wet Electrodes for Recurrent Hepatocellular Carcinoma Following Locoregional Treatments

  • Seong Jun Hong;Jae Hyun Kim;Jeong Hee Yoon;Jeong Hoan Park;Jung-Hwan Yoon;Yoon Jun Kim;Su Jong Yu;Eun Ju Cho;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.438-448
    • /
    • 2024
  • Objective: To evaluate the therapeutic outcomes of no-touch radiofrequency ablation (NT-RFA) using twin cooled wet (TCW) electrodes in patients experiencing recurrent hepatocellular carcinoma (HCC) after undergoing locoregional treatments. Materials and Methods: We conducted a prospective, single-arm study of NT-RFA involving 102 patients, with a total of 112 recurrent HCCs (each ≤ 3 cm). NT-RFA with TCW electrodes was implemented under the guidance of ultrasonography (US)-MR/CT fusion imaging. If NT-RFA application proved technically challenging, conversion to conventional tumor puncture RFA was permitted. The primary metric for evaluation was the mid-term cumulative incidence of local tumor progression (LTP) observed post-RFA. Cumulative LTP rates were estimated using the Kaplan-Meier method. Multivariable Cox proportional hazard regression was used to explore factors associated with LTP. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat (ITT; including all patients) and per-protocol (PP; including patients not requiring conversion to conventional RFA alone) analyses were performed. Results: Conversion from NT-RFA to conventional RFA was necessary for 24 (21.4%) out of 112 tumors. Successful treatment was noted in 111 (99.1%) out of them. No major complications were reported among the patients. According to ITT analysis, the estimated cumulative incidences of LTP were 1.9%, 6.0%, and 6.0% at 1, 2, and 3 years post-RFA, respectively. In PP analysis, the cumulative incidence of LTP was 0.0%, 1.3%, and 1.3% at 1, 2, and 3 years, respectively. The number of previous locoregional HCC treatments (adjusted hazard ratio [aHR], 1.265 per 1 treatment increase; P = 0.004), total bilirubin (aHR, 7.477 per 1 mg/dL increase; P = 0.012), and safety margin ≤ 5 mm (aHR, 9.029; P = 0.016) were independently associated with LTP in ITT analysis. Conclusion: NT-RFA using TCW electrodes is a safe and effective treatment for recurrent HCC, with 6.0% (ITT analysis) and 1.3% (PP analysis) cumulative incidence of LTP at 2 and 3-year follow-ups.

Implant survival and risk factor analysis in regenerated bone: results from a 5-year retrospective study

  • Hong, Ji-Youn;Shin, Eun-Young;Herr, Yeek;Chung, Jong-Hyuk;Lim, Hyun-Chang;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.379-391
    • /
    • 2020
  • Purpose: The aims of this study were to evaluate the 5-year cumulative survival rate (CSR) of implants placed with guided bone regeneration (GBR) compared to implants placed in native bone, and to identify factors contributing to implant failure in regenerated bone. Methods: This retrospective cohort study included 240 patients who had implant placement either with a GBR procedure (regenerated bone group) or with pristine bone (native bone group). Data on demographic features (age, sex, smoking, and medical history), location of the implant, implant-specific features, and grafting procedures and materials were collected. The 5-year CSRs in both groups were estimated using Kaplan-Meier analysis. Risk factors for implant failure were analyzed with a Cox proportional hazards model. Results: In total, 264 implants in the native bone group and 133 implants in the regenerated bone group were analyzed. The 5-year CSRs were 96.4% in the regenerated bone group and 97.5% in the native bone group, which was not a significant difference. The multivariable analysis confirmed that bone status was not an independent risk factor for implant failure. However, smoking significantly increased the failure rate (hazard ratio, 10.7; P=0.002). Conclusions: The 5-year CSR of implants placed in regenerated bone using GBR was comparable to that of implants placed in native bone. Smoking significantly increased the risk of implant failure in both groups.

Incidence and Risk Factors of Recurrent Venous Thromboembolism after Pulmonary Embolism

  • Hwang, Hun-Gyu;Choi, Won-Il;Lee, Bora;Lee, Choong Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.4
    • /
    • pp.341-347
    • /
    • 2019
  • Background: Information about the epidemiology of venous thromboembolism (VTE) recurrence in Korea is lacking. The purpose of this study was to investigate VTE cumulative recurrence rates and identify risk factors for VTE recurrence among Korean adults. Methods: A retrospective cohort study was conducted on adult patients (${\geq}18years$) admitted to a university teaching hospital for pulmonary embolism (PE) from 2005 to 2013. The main outcome of interest was a recurrence of VTE. We used Cox proportional hazard regression analyses to calculate the relative risk of VTE recurrence. Results: Five-year cumulative incidence of recurrent VTE events was 21.5% (95% confidence interval [CI], 17.7-25.4) in all cases of PE; 17% after provoked and 27% after unprovoked PE. Multivariate analysis showed that body mass index (BMI) of ${\geq}25$ (hazard ratio [HR], 2.02; 95% CI, 1.17-3.46; p=0.01) and longer anticoagulation therapy duration (HR, 0.90; 95% CI, 0.84-0.96; p<0.01) were independently associated with risk of VTE recurrence. Risk factors not found to be statistically significant at the <0.05 level included history of VTE (HR, 1.81; 95% CI, 0.84-3.88; p=0.12), unprovoked PE (HR, 1.70; 95% CI, 0.89-3.25; p=0.10), symptomatic deep vein thrombosis (HR, 1.62; 95% CI, 0.89-2.94; p=0.10), and female sex (HR, 1.42; 95% CI, 0.78-2.55; p=0.24). We found that age, history of cancer, and other co-morbidities did not significantly affect the risk of VTE recurrence. Conclusion: Recurrence of VTE after PE is high. Patients with BMI ${\geq}25$ or reduced anticoagulation therapy duration have a higher risk of recurrent VTE.

Association between Cumulative Fluid Balance and Outcomes in Acute Respiratory Distress Syndrome Patients Treated with Extracorporeal Membrane Oxygenation

  • Lee, Jun Hee;Won, Jong Yun;Kim, Ji Eon;Kim, Hee Jung;Jung, Jae Seung;Son, Ho Sung
    • Journal of Chest Surgery
    • /
    • v.54 no.1
    • /
    • pp.36-44
    • /
    • 2021
  • Background: Extracorporeal membrane oxygenation (ECMO) has become increasingly accepted as a life-saving procedure for patients with severe acute respiratory distress syndrome (ARDS). This study investigated the relationship between cumulative fluid balance (CFB) and outcomes in adult ARDS patients treated with ECMO. Methods: We retrospectively analyzed the data of adult ARDS patients who received ECMO between December 2009 and December 2019 at Korea University Anam Hospital. CFB was calculated during the first 7 days after ECMO initiation. The primary endpoint was 28-day mortality. Results: The 74 patients were divided into survivor (n=33) and non-survivor (n=41) groups based on 28-day survival. Non-survivors showed a significantly higher CFB at 1-7 days (p<0.05). Cox multivariable proportional hazard regression revealed a relationship between CFB on day 3 and 28-day mortality (hazard ratio, 3.366; 95% confidence interval, 1.528-7.417; p=0.003). Conclusion: In adult ARDS patients treated with ECMO, a higher positive CFB on day 3 was associated with increased 28-day mortality. Based on our findings, we suggest a restrictive fluid strategy in ARDS patients treated with ECMO. CFB may be a useful predictor of survival in ARDS patients treated with ECMO.

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

No-Touch vs. Conventional Radiofrequency Ablation Using Twin Internally Cooled Wet Electrodes for Small Hepatocellular Carcinomas: A Randomized Prospective Comparative Study

  • Yun Seok Suh;Jae Won Choi;Jeong Hee Yoon;Dong Ho Lee;Yoon Jun Kim;Jeong Hoon Lee;Su Jong Yu;Eun Ju Cho;Jung Hwan Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.1974-1984
    • /
    • 2021
  • Objective: This study aimed to compare the efficacy between no-touch (NT) radiofrequency ablation (RFA) and conventional RFA using twin internally cooled wet (TICW) electrodes in the bipolar mode for the treatment of small hepatocellular carcinomas (HCC). Materials and Methods: In this single-center, two-arm, parallel-group, prospective randomized controlled study, we performed a 1:1 random allocation of eligible patients with HCCs to receive NT-RFA or conventional RFA between October 2016 and September 2018. The primary endpoint was the cumulative local tumor progression (LTP) rate after RFA. Secondary endpoints included technical conversion rates of NT-RFA, intrahepatic distance recurrence, extrahepatic metastasis, technical parameters, technical efficacy, and rates of complications. Cumulative LTP rates were analyzed using Kaplan-Meier analysis and the Cox proportional hazard regression model. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat and as-treated analyses were performed. Results: Enrolled patients were randomly assigned to the NT-RFA group (37 patients with 38 HCCs) or the conventional RFA group (36 patients with 38 HCCs). Among the NT-RFA group patients, conversion to conventional RFA occurred in four patients (10.8%, 4/37). According to intention-to-treat analysis, both 1- and 3-year cumulative LTP rates were 5.6%, in the NT-RFA group, and they were 11.8% and 21.3%, respectively, in the conventional RFA group (p = 0.073, log-rank). In the as-treated analysis, LTP rates at 1 year and 3 years were 0% and 0%, respectively, in the NT-RFA group sand 15.6% and 24.5%, respectively, in the conventional RFA group (p = 0.004, log-rank). In as-treated analysis using multivariable Cox regression analysis, RFA type was the only significant predictive factor for LTP (hazard ratio = 0.061 with conventional RFA as the reference, 95% confidence interval = 0.000-0.497; p = 0.004). There were no significant differences in the procedure characteristics between the two groups. No procedure-related deaths or major complications were observed. Conclusion: NT-RFA using TICW electrodes in bipolar mode demonstrated significantly lower cumulative LTP rates than conventional RFA for small HCCs, which warrants a larger study for further confirmation.