• 제목/요약/키워드: cryocooler

검색결과 188건 처리시간 0.022초

고온 초전도 회전자 냉각을 위한 탑재형 맥동관 냉동기 연구 (Investigation on-board pulse tube refrigerator for high temperature superconducting rotor)

  • 남중원;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.316-319
    • /
    • 2003
  • Cryogenic refrigerator system is necessary for cooling the superconducting rotor. Among the various cryogenic refrigerator systems, on-board hybrid pulse tube cryocooler is designed for cooling the superconducting rotor. Hybrid pulse tube cryocooler is composed of pulse tube cryocooler and Stirling cryocooler. This Stirling cryocooler precools the middle point of regenerator to obtain lower temperature at cold part of pulse tube cryocooler. In this paper, only Stirling cryocooler is on-boarded then rotated by motor for various rotating speeds and heat loads at cold part of Stilting cryocooler. Through this experiment the feasibility of the on-board cryocooler is investigated.

  • PDF

스터링 냉동기의 주파수 특성에 의한 성능평가에 관한 연구 (A Performance test of Stirling Cryocooler by Frequency Characteristics)

  • 박성제;홍용주;김효봉;고득용;오군섭;김종학
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.25-32
    • /
    • 2000
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). A Stirling cryocooler is relatively compact, reliable, commercially available, and uses helium as a working fluid. The FPFD stirling cryocooler consists of two compressor pistons driven by linear motors which makes pressure waves and a pneumatically driven displacer piston with regenerator. The FPFD Stirling cryocooler employs 1) the Stirling cycle for refrigeration, 2) linear for driving the cryocooler, 3) spring and gas support systems, and 4) fine gap for clearance seals. It is the most suitable design for a mechanical cryocooler utilized in night vision environment. In order to get optimum operating frequency, natural frequency of piston and displacer, optimum phase angle between piston and displacer, cooling capacity, performance tests of the Stirling cryocooler by the frequency characteristics were performed.

  • PDF

Effects of cyclic mean pressure of helium gas on performance of integral crank driven stirling cryocooler

  • Hong, Yong-Ju;Ko, Junseok;Kim, Hyo-Bong;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권3호
    • /
    • pp.30-34
    • /
    • 2016
  • An integral crank driven Stirling cryocooler is solidly based on concepts of direct IR detector mounting on the cryocooler's cold finger, and the integral construction of the cryocooler and Dewar envelope. Performance factors of the cryocooler depend on operating conditions of the cryocooler such as a cyclic mean pressure of the working fluid, a rotational speed of driving mechanism, a thermal environment, a targeted operation temperature and etc.. At given charging condition of helium gas, the cyclic mean pressure of helium gas in the cryocooler changes with temperatures of the cold end and the environment. In this study, effects of the cyclic mean pressure of helium gas on performances of the Stirling cryocooler were investigated by numerical analyses using the Sage software. The simulation model takes into account thermodynamic losses due to an inefficiency of regenerator, a pressure drop, a shuttle heat transfer and solid conductions. Simulations are performed for the performance variation according to the cyclic mean pressure induced by the temperature of the cold end and the environment. This paper presents P-V works in the compression and expansion space, cooling capacity, contribution of losses in the expansion space.

동축형 스털링 맥동관 냉동기의 성능개선에 관한 연구 (A Study for Performance Improvements in the Coaxial Type Stirling Pulse Tube Cryocooler)

  • 박성제;홍용주;김효봉;김양훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1329-1334
    • /
    • 2004
  • The most compact and convenient pulse tube cryocooler for practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. The experimental results of the coaxial inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature according to the variations of inertance tube volume, reservoir volume are measured, and the cool down characteristics at the particular conditions are presented. In case of the coaxial type inertance tube pulse tube refrigerator, cool down time is the lowest in the inertance tube diameter of 1.3 mm and inertance tube length of 1900 mm and lowest temperature is 112K. This results are not satisfactory for practical applications. So, We propose vacuum insulation between regenerator and pulse tube in the Stirling type coaxial pulse tube cryocooler. Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube was designed and manufactured by KIMM(Korea Institute of Machinery and Materials). The optimal conditions will be tested for Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube.

  • PDF

탑재형 냉동기를 이용한 고온 초전도 모터 개발 및 회전 실험 (Development and rotating test of the high temperature superconducting motor with on-board cryocooler)

  • 기태경;김영권;김희선;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.12-16
    • /
    • 2011
  • In this paper, the prototype of the HTS motor with an on-board cryocooler, is fabricated and tested. The overall system is composed of the stator with conventional copper winding, the rotor with superconductor, and the rotating cryocooler designed from the on-board concept. The rotor is fabricated as the race-track coil with 2G, YBCO tape and contacts with the on-board cryocooler while being rotated together. An inline-type pulse tube refrigerator is used as the on-board cryocooler. The cryocooler is fabricated from optimal process to satisfy the structure and thermal stability of the on-board system. Each component is integrated according to carefully defined sequence. Specially, a combining method of torque tubes is an important part for sustaining stability of the rotor and the cryocooler. In the rotating test, the HTS motor is successfully operated with 240 rpm of rotating speed when 75 A current is supplied to the superconducting rotor. In this paper, potential problems of the HTS motor system using the on-board cryocooler are proposed and solved, and realistic possibility of this concept is also confirmed.

HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구 (Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling)

  • 박재홍;권용하;김영수;박성출
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

Split tube 길이변화에 따른 스터링 극저온 냉동기의 특성에 관한 연구 (Study of Stirling Cryocooler Performance with different length of split tube)

  • 홍용주;박성제;고득용;김효봉;오군섭;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, performance tests of stirling cryocooler with different length of split tube were performed to get characteristics of cryocooler. The Experimental results show the Stirling cryocooler with small volume of split tube has higher cooling power and faster response time.

  • PDF

적외선 센서 냉각용 스터링 냉동기의 성능시험 (Performance Test of the Stirling Cryocooler for Cooling of the Infrared Detectors)

  • 고득용;박성제;김효봉;염한길;김홍국;김남환
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.202-206
    • /
    • 1999
  • This paper presents operating process of the Stirling cryocooler and results obtained with the performance test for Signal Usfa UP 7075 Stirling cryocooler. An experimental study was carried out to develop the more reliable Stirling cryocooler. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the Stirling cryocooler wa 62.5K and the cooling capacity at the optimum operating condition was 0.4W at 77K. At that time, carnot COP was 0.024.

  • PDF

Performance improvement of 2 stage GM-type pulse tube Cryocooler for cryopump

  • Park, Seong-Je;Koh, Deuk-Yong;Suh, Jeong-Kyoon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권4호
    • /
    • pp.30-35
    • /
    • 2011
  • This paper describes experimental study and performance improvement of 2 stage Gifford-McMahon (G-M) type pulse tube cryocooler for cryopump. The objective of this study is to improve the efficiency of 2 stage pulse tube cryocooler for substituting 2 stage G-M cryocooler used in cryopump. The target cooling capacities are 5 W at 20 K and 35 W at 80 K for the $1^{st}$ and the $2^{nd}$ stage, respectively. These values are good cooling capacities for vacuum level in medium size ICP 200 cryopump. Design of the 2 stage pulse tube cryocooler is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program. In order to improve the performance of 2 stage pulse tube cryocooler, U-type pulse tube cryocooler is fabricated and connecting tubes are minimized for reducing dead volumes and pressure losses. Also, to get larger capacities, orifice valves and double inlet valves are optimized and the compressor of 6 kW is used. On the latest unit, the lowest temperatures of 2 stage pulse tube cryocooler are 42 K ($1^{st}$ stage) and 8.3 K ($2^{nd}$ stage) and the cooling capacities are 40 W at 82.9 K ($1^{st}$ stage) and 10 W at 20.5 K ($2^{nd}$ stage) with 6.0 kW of compressor input power. This pulse tube cryocooler is suited for commercial medium size cryopump. In performance test of cryopump with 2 stage pulse tube cryocooler, pumping speed for gaseous nitrogen is 4,300 L/s and the ultimate vacuum pressure is $7.5{\times}10^{-10}$ mbar.

초전도 필터 냉각용 선형압축기형 맥동관 냉동기의 실험적 연구 (An Experimental Study of the Pulse Tube Cryocooler with the Linear Compressor)

  • 박성제;홍용주;김효봉;고득용;염한길;김양훈;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.197-201
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stirling cryocooler and inertance pulse tube cryocooler for the cooling infrared detector and cryosensor are currently under development at Korea Institute of Machinery & Materials. The pulse tube cryocooler, which has no moving parts at its cold section, is attractive for obtaining higher reliability, simpler construction and lower vibration than in any other small cryocoolers. In recent years, pulse tube cryocoolers have experienced a rapid development with the aim to eventually replace Stirling and Gifford-McMahon cryocoolers in various applications. In this study, operating characteristics of the conventional linear Stirling cryocooler was investigated by experiment. And, inertance pulse tube cryocooler with the commercial linear compressor(Leybold Polar) was designed, manufactured, and tested by the variations of the operating frequency, charging pressure and input power.

  • PDF