• Title/Summary/Keyword: crown ratio

Search Result 283, Processing Time 0.023 seconds

Surgical extrusion of a maxillary premolar after orthodontic extrusion: a retrospective study

  • Choi, Yong-Hoon;Lee, Hyo-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.254-259
    • /
    • 2019
  • Objectives: Crown-root fracture and cervical caries in maxillary premolars constitute a challenge in cases of subgingival placement of restoration margins. Surgical extrusion has been practiced successfully in permanent anterior teeth. The aim of the present retrospective study was to assess the clinical outcome of surgical extrusion after orthodontic extrusion in maxillary premolars. Materials and Methods: Twenty-one single, tapered root maxillary premolars with subgingival crown-root fracture or caries were included. Presurgical orthodontic extrusion was performed on all teeth to prevent root resorption. Extent of extrusion and rotation was determined based on crown/root ratio. The postoperative splinting period was 7 to 14 days. Clinical and radiographic examination was performed at an interval of 1, 2, and 3 months. Results: After the mean follow-up of $41.9{\pm}15.2months$, failure was observed as increased mobility in 3 of 21 cases. No significant difference was observed in the outcome of surgical extrusion based on tooth type, age, sex, $180^{\circ}$ rotation, or time for extraction. Furthermore, marginal bone loss was not observed. Conclusion: Surgical extrusion of maxillary premolars can be a possible therapeutic option in cases of subgingival crown-root fracture.

A Roentgenographic Study on the Development of Human Permanent Posterior Teeth (영구 구치 발육에 관한 방사선학적 연구)

  • Young-Ku Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.73-84
    • /
    • 1991
  • 저자는 연령을 추정하기 위한 기본자료를 얻기 위하여 상하악의 대구치, 소구치의 발육정도를 평가하였다. Orthopantomograph를 촬영한 722명의 3,464개 치아를 대상으로 crown-root ratio를 측정하여 발육정도를 평가하였으며, 다음과 같은 결론을 얻었다. 1. 완전히 형성된 치아의 crown-root ration에는 남녀간에 유의한 차이가 없었다. 2. 발육중인 치아의 crown-root ratio에는 좌우측간에 유의한 차이가 없었다. 3. 각 치아의 crown-root ratio를 이용한 연령추정의 회귀방정식은 다음과 같다. 남자: 여자 : 하악좌측 제 2대구치 : Y=4.599X+7.832(r=0.8337) 하악 좌측 제 2대구치 : Y=4.857X+7.429(r=0.8975) 제 1대구치 : Y=5.179X+2.324(r=0.7948) 제 1대구치 : Y=5.919X+2.018(r=0.8144) 제 2소구치 : Y=3.863X+7.432(r=0.8638) 제 2소구치 : Y=3.679X+7.275(r=0.8819) 제 1소구치 : Y=3.472X+7.120(r=0.8352) 제 1소구치 : Y=4.001X+6.544(r=0.9024) 하악우측 제 2대구치 : Y=4.447X+7.938(r=0.8045) 하악 우측 제 2대구치 : Y=4.653X+7.365(r=0.8598) 제 1대구치 : Y=5.954X+1.495(r=0.7777) 제 1대구치 : Y=5.449X+2.012(r=0.7553) 제 2소구치 : Y=3.894X+7.253(r=0.8689) 제 2소구치 : Y=3.772X+7.025(r=0.8719) 제 1소구치 : Y=4.189X+6.717(r=0.8370) 제 1소구치 : Y=4.327X+6.193(r=0.8524) 상악좌측 제 2대구치 : Y=4.430X+7.722(r=0.7538) 상악 좌측 제 2대구치 : Y=4.876X+7.606(r=0.8311) 제 1대구치 : Y=4.645X+2.886(r=0.6894) 제 1대구치 : Y=6.754X+1.891(r=0.5378) 제 2소구치 : Y=4.391X+6.686(r=0.7700) 제 2소구치 : Y=1.245X+10.575(r=0.1908) 제 1소구치 : Y=5.564X+6.037(r=0.9032) 제 1소구치 : - 상악우측 제 2대구치 : Y=4.587X+7.966(r=0.7882) 상악 우측 제 2대구치 : Y=4.454X+7.803(r=0.8443) 제 1대구치 : Y=4.047X+4.124(r=0.6352) 제 1대구치 : Y=6.336X+2.911(r=0.4688) 제 2소구치 : Y=2.920X+8.089(r=0.7277) 제 2소구치 : Y=3.105X+8.082(r=0.6381) 제 1소구치 : Y=3.264X+6.970(r=0.7292) 제 1소구치 : - 4. Orthopantomograph상의 crown-root ratio를 이용한 연령의 추정에는 상악치아들 보다 하악치아들이 더 정확하게 사용될 수 있다.

  • PDF

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

EFFECTS OF DIFFERENT PREPARATION METHODS ON THE MORPHOLOGIC CHANGE OF SIMULATED ROOT CANALS IN RESIN BLOCK (수종 근관형성방법에 따른 레진모형상의 근관형태의 변화)

  • Park, Mi-Hee;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.85-96
    • /
    • 1994
  • In this study, 24 curved resin blocks were prepared by one of the following four methods: 1) Conventional technique using K-flexo files 2) Step-back technique using K-flexo files 3) Crown-down technique using K-flexo files 4) Canal Master instrumentation using Canal Master Resin blocks were sectioned, photographed, and evaluated the mean centering ratio and the mean area of dentin removed before and after the instrumentation. The results were as follows : I. the mean centering ratio 1. In the level 1 and level 3, there was no significant difference in the mean centering ratio. 2. In the level 2, Step-back technique showed the worst mean centering ratio among the tested groups(p<0.001) and there was no significant difference between the other three groups. 3. In the level 4, Canal Master instrumentation and Step-back technique showed better mean centering ratio than the other two techniques(p<0.001) and there was no significant difference between the two techniques. II. the mean area of dentin removed 1. In the level l and level 3, there was no significant difference in the mean area of dentin removed. 2. In the level 2, Canal Master instrumentation removed less dentin than the other three techniques(P<0.01). 3. In the level 4, Crown-down technique removed less dentin than the other three techniques(P<0.05).

  • PDF

A Study on the labial & buccal surface contour in Korean permanent teeth using three-dimensional laser scanning (3차원 레이저 스캐너를 이용한 한국인 영구치의 순, 협측 치관 굴곡도에 관한 연구)

  • Ko, Sang-Duck;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.275-291
    • /
    • 2002
  • Of various factors indicated for effective use of straight wire appliances, there was a great lack of studies both domestic and international about the curvatures of tooth crowns. This study was performed to investigate the labio/buccal clinical crown curvatures of Korean permanent teeth. For this study, three-dimensional laser scanning was performed on 36 dental casts with normal anatomic structures. Andrews plane and Facial axis of clinical crown (FACC) were designated as horizontal and vertical reference planes respectively. 2 or 3 lines, 1mm apart, were drawn superior, inferior, left and right of these reference planes. A three-dimensional coordinate table was made for points formed by crossing these lines, and averages of each coordinate point on the 36 dental casts were obtained. The curvature equation was made using three-dimensional coordinate points (x,y,z) and by this curvature equation, the curve ratio of each tooth was obtained. Curve ratio changes of each section of teeth were calculated by curve ratios of simplified curves. These two dimensional curves were simplified horizontally and vertically Conclusions for this study are as follows. 1. The basic data of labial and buccal clinical crown curvatures were obtained about Korean permanent teeth. 2. No significant difference was found between male and females. 3. Individual tooth characteristics 1) In maxillary central incisors, the difference in the curve ratio between the gingival and incisal sides was greater than for the other teeth. And the gingival side showed a greater curve ratio. 2) Maxillary canines showed more curvatures in the mesio-occlusal surface than the other surfaces. 3) In maxillary $1^{st}$ premolars, more curvatures were found in mesio-occlusal and disto-gingival surface, thus showing a twisted crown surface, but in maxillary $2^{nd}$ premolars, the crown curvatures of mesial and distal ends became parallel to each other. 4) No significant difference in crown curvatures was found between mandibular central and lateral incisors. 5) Occluso-gingival curvatures of mandibular$2^{nd}$ premolar turned out to be more rounded than mandibular $1^{st}$ premolars or maxillary $2^{nd}$ premolars. From the above conclusions, it can be deduced that the same bracket bases can be used for mandibular central and lateral incisors. But for maxillary $1^{st}\;and\;2^{nd}$ premolars and for mandibular $1^{st}\;and\;2^{nd}$ premolars, because crown curvatures showed significant differences, when making bracket bases there is ample reason to make bracket base curves differently for each type of tooth.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS (내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구)

  • Kim Yu-Lee;Cho Hye-Won;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.

Influence of Compression Ratio on Engine Performance in Heavy-duty LPG Single-cylinder Engine (대형 LPG 단기통엔진에서 압축비가 기관성능에 미치는 영향)

  • 김진호;최경호
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.160-165
    • /
    • 2002
  • The heavy-duty LPG-fueled single cylinder engine was designed and developed as a fundamental equipment for analyzing combustion processes and emission performances. The cylinder head and the piston crown were modified to fire the LPG in the engine. The flywheel was also fabricated to minimize the vibration of the single cylinder engine. The size of bore and stroke of the tested engine are 130 mm and 140 mm, respectively. Compression ratios were varied 8 to 9 with different piston crown shapes. The developed single cylinder engine operates at 1,000 rpm for this work. The major conclusions of this work are; (1) the power of the developed engine was peaked at the condition of equivalence ratio 1.0 at three different compression ratios; (2) the power is slightly increased with the increase of compression ratio; (3) the optimum ignition timing is retarded with the increase of compression ratio ranged 2 to 10 crank angle.

An Experimental Study on Cement Film Thickness Between Casting Restorations and Preparation Walls. (주조물(鑄造物) 접착후(接着後) Cement층(層) 후경측정(厚徑測定)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Ui-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 1968
  • The purposes of this study were to measure the film thickness of zinc phosphate cement between the casting restorations and preparation walls. In addition, the differences between finger press and non press techniques after the castings were seated completely on the preparation by an automatic mallet until the cement set were studied. The results were as follows : 1) In full cast crown, the cement film thickness on the side wall was thinner than that on the other walls. 2) In 3/4 crown and inlay, the cement thickness was thinner than that in cast crowns. 3) The cement of great W/P ratio showed thinner thickness than that of little W/P ratio. 4) The continuous finger press after the castings were seated completely on the preparations had few influence on the cement film thickness.

  • PDF

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.

Effects of Tree Form on Number of Cone Formation in Korean White Pine (Pinus koraiensis S. et Z.) (잣나무에 있어서 수형(樹形)이 결실량(結實量)에 미치는 영향(影響))

  • Chon, Sang Keun;Noh, Youn Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.62 no.1
    • /
    • pp.19-23
    • /
    • 1983
  • Number of 1-year-old cone in Pinus koraiensis was influenced by the factors consisting of the tree form. Number of cones increased with increasing DBH, diameter, volume of crown and number of forked stems. However, tree height, crown length, and the ratio of crown diameter to crown length showed no significant relations with number of cones.

  • PDF