• 제목/요약/키워드: crosslinked polyethylene(XLPE)

검색결과 30건 처리시간 0.021초

가교폴리에틸렌 수지의 가교온도변화에 따른 전기트리의 진전과정에 관한 연구 (A Study on Growthing Process of Electrical Tree According to Crosslinked Temperature Variation in XLPE)

  • 김상기;김덕근;임장섭;오무송;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.173-176
    • /
    • 1999
  • Crosslinked Decree is an important 7actor to determine dielectric property of crosslinked polyethylene(XLPE) used for the insulation material in Power cables. Recently, though it is necessary to investigate electrical properties according to crosslinked degree as a Part of the whose characterization of cable. it is not examined closely. In this study. crosslinked degree of samples were measured according to temperature and holding time of crosslinking. electrical tree characteristics of these characteristics of these samples were analyzed by crosslinked degree and applied temperature that was chanced from normal temperature to operating temperature of power cables. As a result. when the crosslinked degree was low, dielectric properties were decreased and influence of temperature was increased. but the crosslinked degrees were high, initiation voltages of treeing were increased and dielectric properties were improved. It is proved that the optimum crosslinked degree was one of most important factor for aging time and residual lifetime of Power cable.

  • PDF

XLPE의 가교도 분포에 따른 전기트리 진전 특성 분석 (Analysis on Electrical Tree Growth Characteristics in XLPE According to Crosslinked Degree)

  • 김상기;김덕근;이정빈;이진;김태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.901-903
    • /
    • 1998
  • Crosslinked Degree is an important factor to determine dielectric property of crosslinked polyethylene(XLPE) used for the insulation material in power cables. Recently, though it is necessary to investigate electrical properties according to crosslinked degree as a part of the whole characterization of cable. it is not examined closely. In this study, crosslinked degree of samples were measured according to temperature and holding time of crosslinking, electrical tree characteristics of these samples were analyzed by crosslinked degree and applied temperature that was changed from normal temperature to operating temperature of power cables. As a result. when the crosslinked degree was low, dielectric properties were decreased and influence of temperature was increased. but the crosslinked degrees were high. initiation voltages of treeing were increased and dielectric properties were improved. It is proved that the optimum. crosslinked degree was one of most important factor for aging time and residual lifetime of power cable.

  • PDF

가교 폴리에틸렌의 수트리 특성 (Water Tree Characteristics of Crosslinked Polythylene)

  • 남진호;김웅;김현석;김준선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.295-295
    • /
    • 2008
  • Water tree experiments were done for several types of cross-linked polyethylenes. Test method is followed by ASTM D6097. Polyethylene is divided for four subgroup. First One is chemically cross-linked general XLPE, and second one is chemically cross-linked tree-retardant XLPE, and the third one is silane cross-linked polyethylene made by monosil process, and the last one is silane cross-linked polythylene made by copolymer. Tree retardant XLPE shows the shortest water tree length. Cahemcally cross-linked general XLPE shows the longest water tree length. Silane cross-linked polyethylene by copolymer is similar to tree retardant XLPE and similar breakdown strength. So silane cross-linked XLPE by copolymer could be used for the the medium voltage cable which should have tree retardant characteristics.

  • PDF

초임계 메탄올에서 가교폴리프로필렌과 가교폴리에틸렌의 재활용성 비교 (Recycling of Crosslinked Polypropylene and Crosslinked Polyethylene in Supercritical Methanol)

  • 이홍식;정주형;홍순만;구종민;조항규;이윤우
    • Korean Chemical Engineering Research
    • /
    • 제50권1호
    • /
    • pp.88-92
    • /
    • 2012
  • 초임계 메탄올에서 가교폴리프로필렌의 탈가교 반응에 대해 연구하고 이를 가교폴리에틸렌의 탈가교 반응과 비교하였다. 회분식 반응기를 이용하여 반응 온도와 초기 겔 함량이 탈가교 반응 속도에 미치는 영향을 알아보았고, 정량적 분석을 위해 반응 전후의 겔 함량을 측정하였다. 반응 온도가 증가할수록, 초기 겔 함량이 증가할수록 탈가교 반응속도가 증가하였고, 반응 속도는 겔 함량에 선형적으로 의존하였다. 가교폴리프로필렌의 탈가교 반응이 가교폴리에틸렌보다 빠르게 일어나는 것을 확인하였고, 반응속도상수를 계산하여 이를 정량적으로 확인하였다. 이를 통해 재활용 측면에서는 가교폴리프로필렌이 가교폴리에틸렌보다 우수한 것을 알 수 있다.

XLPE 케이블의 트리잉 열화에 따른 음향방출 특성 (Title: A Characteristics of Acoustic Emission according to Treeing Deterioraction in Crosslinked Polyethylene Cable)

  • 조대연;김명호;백관현;심종탁;박재준;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.973-975
    • /
    • 1992
  • The Acoustic Emission due to treeing progress in Crosslinked Polyethylene(XLPE) is studied by using the self developed automatic measuring system of acoustic emission. Tree progression and average pulse amplitude are almost in proportion to the rising of applied voltage but there is no proportionality relation between tree progression and pulse numbers. From now on, Skewness and kurtosis of average cycle, special property of $\phi$-a distribution characteristics can be confirmed as the useful parameters of treeing deterioration.

  • PDF

이온성 불순물과 폴리에틸렌의 절연파괴특성 (Ionic Impurities and Dielectric Breakdown of XLPE)

  • 윤종복;서광석;변재동;한재홍;김상준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.58-61
    • /
    • 1997
  • Effects of ionic impurities on the dielectric breakdown of the crosslinked polyethylene (XLPE) were studied using aqueous electrolytes. It was found that the AC breakdown strength of XLPE decreases considerably when the ions are present in the electrodes composed of aqueous electrolyte. Details of results were described.

  • PDF

모듈라 치합형 동방향회전 이축 스크류식 압출기를 이용한 폐 XLPE의 재활용 (Recycling of Waste XLPE Using a Modular Intermeshing Co-Rotating Twin Screw Extruder)

  • 방대석;오수석;이종근
    • Elastomers and Composites
    • /
    • 제39권2호
    • /
    • pp.131-141
    • /
    • 2004
  • 본 연구에서는 폐기되는 고전압용 전선으로부터 얻어질 수 있는 XLPE(crosslinked polyethylene)의 재활용에 관하여 고찰하였다. XLPE 스크랩 및 폐기물의 분쇄를 위해 약 $100{\mu}m$ 이하부터 약 $1000{\mu}m$까지 입자크기의 조절이 가능한 두 종류의 분쇄기를 사용하였다. 모듈라 치합형 동방향회전 이축 스크류식 압출기(modular intermeshing co-rotating twin screw extruder)를 이용하여 폐 XLPE의 조성, 폐 XLPE의 입자크기 및 종류, 스크류 조합, 매트릭스 수지의 종류(LDPE, HDPE, PP, PS) 조건을 변화시키면서 배합물을 제조하고 그들의 기계적 및 유변학적 특성과 파단면을 조사하였다. 일반적으로 내외 전도층을 포함한 폐 XLPE 배합물의 충격강도는 내외 전도층을 제외한 배합물보다 충격강도가 작은 것으로 나타났다. 또한, XLPE의 함량이 증가하고 입자크기가 작아 질수록 배합물의 충격강도가 증가하였다. 특히, LDPF의 경우 XLPE를 약 80 wt%까지 충전하여도 정상조건의 압출공정이 가능하였다. 스크류조합에 따른 배합물의 충격강도는 니딩디스크 블록(kneading disc block)의 수가 많을수록 높은 값을 나타내었다. 전체적으로 XLPE의 양이 증가할수록 배합물의 용융점도가 증가하였으나, 압출 전단속도 범위에서 shear thinning 경향을 나타내었다. 폐 XLPE를 범용 고분자수지와 혼합할 경우, LDPE, HDPE, PP 및 PS 모든 배합물에서 충격강도가 증가하였다. 특히, PS/XLPE 배합물의 경우에는 충격강도가 2 배정도 향상되는 효과를 보여주었다.

XLPE/EnBA 블렌드의 전기 및 물리적 성질 (Electrical and Physical Properties of XLPE/EnBA Blends)

  • 서광석;오우정;이승형
    • 한국전기전자재료학회논문지
    • /
    • 제11권12호
    • /
    • pp.1060-1069
    • /
    • 1998
  • Electrical properties such as space charge accumulation and water tree length and physical properties such as tensile strength, elongation and degree of crosslinked polyethylene (XLPE)/ethylene n-butyl acrylate copolymer (EnBA) blends were investigated. It was found that electrical properties such as water tree length grown at a specific condition and AC breakdown strength are improved by blending the XLPE with EnBA. The EnBA having higher nBA content showed the better electrical properties in XLPE/EnBA blends. A further improvement of these properties was achieved when a small amount of crosslinking coagent was used in the preparation of XLPE/EnBA blends.

  • PDF

XLPE/EPDM laminate의 첨가제에 따른 전하분포특성 (Interfacial Breakdown Characteristics in XLPE/EPDM Laminate as a function of Additives)

  • 남진호;서광석
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 추계학술대회논문집
    • /
    • pp.77-80
    • /
    • 2000
  • In order to determine what influences the interfacial charge in EPDM/XLPE laminates, We used PEA (pulsed electroacoustic) method. Interfacial properties such as space charge accumulation and breakdown strength in crosslinked polyethylene (XLPE)/ethylene-propylene-diene monomer (EPDM) laminates were investigated. Interfacial charge develops when the EPDM is laminated with XLPE. It showed the positive polarity same as the simulation in case on intercase of EPDM/XLPE. In case of coupling agent added silicone oil, as increasing the content of coupling agent, the interfacial charge decreased. Details of the results are given and their origins discussed.

  • PDF

XLPE/EPDM laminates의 계면현상 (Interfacial phenomena of XLPE/EPDM laminates)

  • 남진호;서광석;김지환;고광철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.211-214
    • /
    • 1998
  • DC breakdown characteristics and formation of space charge at the interfaces of crosslinked polyethylene (XLPE) /ethylene propylene diene terpolymer (EPDM) laminates were studied. Effects of silicone grease and some chemicals such as crosslinking coagent on the interfacial charge were also studied. Interfacial charge develops at the interface of XLPE/EPDM laminates, which changes depending on heat treatment conditions and types of chemicals coated at the interface. Some chemicals such as maleic anhydride reduce the accumulation of interfacial charge in the XLPE/EPDM laminates. Breakdown strength of EPDM/XLPE laminate through the interface was highest when silicone oil was pasted in the interfaces. Interfacial breakdown strength decreased with the increase of MAH content.

  • PDF