• Title/Summary/Keyword: cross-sectional capacity

Search Result 178, Processing Time 0.028 seconds

The Significance of the Strong Ion Gap in Predicting Acute Kidney Injury and In-hospital Mortality in Critically Ill Patients with Acute Poisoning (중증 급성 중독 환자에서 급성 신장 손상과 병원 내 사망률을 예측하기 위한 강이온차(Strong Ion Gap)의 중요성)

  • Sim, Tae Jin;Cho, Jae Wan;Lee, Mi Jin;Jung, Haewon;Park, Jungbae;Seo, Kang Suk
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.72-82
    • /
    • 2021
  • Purpose: A high anion gap (AG) is known to be a significant risk factor for serious acid-base imbalances and death in acute poisoning cases. The strong ion difference (SID), or strong ion gap (SIG), has recently been used to predict in-hospital mortality or acute kidney injury (AKI) in patients with systemic inflammatory response syndrome. This study presents a comprehensive acid-base analysis in order to identify the predictive value of the SIG for disease severity in severe poisoning. Methods: A cross-sectional observational study was conducted on acute poisoning patients treated in the emergency intensive care unit (ICU) between December 2015 and November 2020. Initial serum electrolytes, base deficit (BD), AG, SIG, and laboratory parameters were concurrently measured upon hospital arrival and were subsequently used along with Stewart's approach to acid-base analysis to predict AKI development and in-hospital death. The area under the receiver operating characteristic curve (AUC) and logistic regression analysis were used as statistical tests. Results: Overall, 343 patients who were treated in the intensive care unit were enrolled. The initial levels of lactate, AG, and BD were significantly higher in the AKI group (n=62). Both effective SID [SIDe] (20.3 vs. 26.4 mEq/L, p<0.001) and SIG (20.2 vs. 16.5 mEq/L, p<0.001) were significantly higher in the AKI group; however, the AUC of serum SIDe was 0.842 (95% confidence interval [CI]=0.799-0.879). Serum SIDe had a higher predictive capacity for AKI than initial creatinine (AUC=0.796, 95% CI=0.749-0.837), BD (AUC=0.761, 95% CI=0.712-0.805), and AG (AUC=0.660, 95% CI=0.607-0.711). Multivariate logistic regression analyses revealed that diabetes, lactic acidosis, high SIG, and low SIDe were significant risk factors for in-hospital mortality. Conclusion: Initial SIDe and SIG were identified as useful predictors of AKI and in-hospital mortality in intoxicated patients who were critically ill. Further research is necessary to evaluate the physiological nature of the toxicant or unmeasured anions in such patients.

Evaluation on the Structural Performance and Economics of Ultra-high Performance Concrete Precast Bridges Considering the Construction Environment in North Korea (북한 건설환경을 고려한 초고성능 콘크리트 프리캐스트 교량의 구조성능 및 경제성 평가)

  • Kim, Kyoung-Chul;Koh, Kyung-Taek;Son, Min-Su;Ryu, Gum-Sung;Kang, Jae-Yoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.208-215
    • /
    • 2021
  • In this study, a customiz ed bridge system was developed for North Korea application. For the application of North Korea, the customized bridge system design, fabrication, and construction performance evaluation were performed using ultra-high performance concrete a compressive strength 120MPa or more and a direct tensile strength 7MPa or more. The comparison of the North Korean truck luggage load(30, 40, 55) and the Korean standard KL-510 load showed that cross-section increased as the load increased. Furthermore, a bridge with a span length of 30m was fabricated with ultra-high performance concrete for the construction performance evaluation. The evaluation of the load condition analysis was performed by a flexural test. The results showed that a bridge with a span length of 30m secured about 167% of sectional performance under initial cracking load conditions and about 134% of load bearing capacity under ultimate load conditions. As a result of economic analysis, the customized bridge system using ultra-high-performance concrete was less than about 11% of the upper construction cost compared to the steel composite girder bridge. Therefore, these results suggest that the price competitiveness can be secured when applying the ultra-high-performance concrete long-span bridge developed through this study.

Geographical Discrepancies in Residential Outcomes and Housing Expenditure of Young Married Couples in Chonsei Housing (전세 거주 청년 부부가구의 지역 간 거주환경과 주거비 차이)

  • Hyunjeong Lee;Sangjun Nam
    • Land and Housing Review
    • /
    • v.14 no.3
    • /
    • pp.17-36
    • /
    • 2023
  • This research aims to investigate the socio-demographic, financial, and housing statuses of young married couples in Chonsei housing and to analyze the determinants of their residential environment quality and housing expenditure in four districts - Seoul and Gyeonggi-Incheon Area(GIA) of the Seoul Metropolitan Area(SMA), and metropolises and non-metropolises of non-SMA. From the 2020 Korean Housing Survey(KHS), this cross-sectional analysis examined a sample of 691 households, and the findings revealed that most were headed by college-educated, salaried male workers aged 31 years old. While childless dual-earner couples were common in Seoul, single-income families of three were prevalent in non-SMA. The financial status of the couples in Seoul was a lot better than in the other three areas, particularly much higher in Chonsei deposit and total asset value. Further, many lived in a three-bedroom apartment unit sized 60m2 and bigger, using a Chonsei loan. Regardless of areas, almost all the households spent a very low portion of their living expenses and income on housing costs. However, dual-earner families positively increased borrowing capacity, which improves the household's financial position that is likely to lead to equity increment in a volatile asset market in the long run. The statistical results indicated that residential environment assessment was influenced by neighborhood quality and housing expenditure was affected by housing size in Seoul, urban amenities in GIA and householder's gender in non-metropolises. Thus, this research proposes that strong measures be considered to mitigate housing inequality embedded in geographical and socio-economic disparities.

The Impacts of Exploration and Exploitation Alliance on the Firm Performance: Focused on Global Supply Chain Management of 'Galaxy Note' (탐색제휴와 활용제휴가 기업의 성과에 미치는 영향: '갤럭시 노트'의 글로벌공급망을 중심으로)

  • Son, In-Sung;Kim, Si-Hyun
    • Korea Trade Review
    • /
    • v.42 no.5
    • /
    • pp.113-136
    • /
    • 2017
  • New product preannouncement through global supply chain management and international strategic alliances is a critical issue for firm's survive and gaining the competitive advantage in the global smart-phone market. To identify the impact of exploration alliance and exploitation alliance on the short-term's Firm Performance, respectively, This study implemented the event study and the cross sectional regression analysis, focusing on the case of Galaxy Note series. Research results identified that new technologies by exploration alliance and the existing technologies through exploitation alliance have a positive effect on the short-term's performance of vendors related. Furthermore, information for the new products showed higher the excess earning rate than information related to the existing technologies. This implies the firms that provides new technologies have a stronger innovative ability than the companies serving the existing technologies, recognizing as a positive signal in the market. Finally, this study implicates that new technologies by exploration alliance enhances innovative abilities from new product preannouncement, and is a critical variable that can determines whether to survive in the market.

  • PDF

Predictors of Burnout among Staff in Long-term Care Facilities for the Elderly (노인장기요양보호 인력의 소진 예측 요인)

  • Lee, Choo-Jae
    • 한국노년학
    • /
    • v.31 no.1
    • /
    • pp.97-109
    • /
    • 2011
  • The purpose of this work is to examine how work stressors are related to the burnout among staff in long-term care facilities for the elderly. This study offers some responses to a growing stress and burnout for the long-term care workers. The demand for long-term care workers is set to rise in light of an increasing share of older people and dependent elderly. Long-term care workers provide long-term care services to persons with a reduced degree of functional, physical or cognitive capacity. Cross-sectional survey data were collected from 216 staff in long-term care facilities. The standardised Maslach Burnout Inventory(MBI) was used to assess levels of burnout in long-term care workers. The MBI consists of 22 items using a 5-point Likert scale, measuring three sub-scales of burnout; Emotional exhaustion, Depersonalization, and Personal accomplishment. Data were analyzed using regression. This study is empirically tested the degree of association between burnout and its antecedents. The majority of differences in burnout could be explained by work stressors such as client relationship, job overload, job role conflict, and conflicts with clients' family. The study also identified workers' perceptions of their image in society and emotional support as predictors of burnout. Therefore long-term care facilities are encouraged to review their practices so that workers well-being is supported. The study findings suggest attention for organizational oriented initiatives to cope with burnout.

Corrosion Behavior and Ultrasonic Velocity in RC Beams with Various Cover Depth (다양한 피복두께를 가진 RC 보의 부식 거동 및 초음파 속도)

  • Jin-Won Nam;Hyun-Min Yang;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.184-191
    • /
    • 2023
  • With increasing corrosion in RC (Reinforced Concrete) structures, cracks occurred due to corrosion products and bearing load resistance decreased. In this study, corrosion was induced through an accelerated corrosion test (ICM: Impressed Current Method) with 140 hours of duration, and changes in USV (Ultra-Sonic Velocity), flexural failure load, and corrosion weight were evaluated before and after corrosion test. Three levels of cover depth (20 mm, 30 mm, and 40 mm) were considered, and the initial cracking period increased and the rust around steel decreased with increasing cover depth. In addition, the USV linearly decreased with decreasing cover depth and increasing amount of corrosion. In the flexural loading test, the bending capacity decreased by more than 10% due to corrosion, but a clear correlation could not be obtained since the corrosion ratio was small, so that the effect of slip was greater than that of reduced cross-sectional area of steel due to corrosion. As cover depth increased, the produced corrosion amount and USV changed with a clear linear relationship, and the cracking period due to corrosion could be estimated by the gradient of the measured corrosion current.

Studies on the Overflow from Torrential Stream -A Case Study at the Samsung-cheon in Mt. Kwanak- (야계(野溪)의 월류발생(越流發生)에 관(關)한 연구(硏究) -관악산(冠岳山) 삼성천(三聖川)에서의 시험사례(試驗事例)-)

  • Woo, Bo Myeong;Kim, Kyong Ha;Jeong, Do Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.269-275
    • /
    • 1988
  • To investigate the cause of overflow in the torrential stream, the estimated peak flow of run-off and the maximum tarring capacity of the stream were measured at the upstream of Samsung-cheon located in Kwanak Aboretum during July, 1987. The results obtained from this study could be summarized as follows : 1. The surveyed catchment area was 477ha, which was 116 of the designed area (410ha) by the plan. 2. The maximum rainfall intensity measured was 99.5mm/hr and was almost same as the designed intensity(100mm/hr). 3. The surveyed run-off coefficient was 0.672 that was about twice as much as designed one(0.35). 4. The surveyed peak flow of run-off was $88.59m^3/sec$, 222% as large the designed one($39.9m^3/sec$). 5. The designed cross-sectional area of the stream was $17.25m^2$, which was 68% of the designed one$25.43m^2$. 6. The surveyed hydraulic mean radius was 0.94m, which was shorter than the designed one(1.28m). 7. The surveyed mean stream-bed gradient(0.998%) was almost the same as the designed one(1.00%). 8 The surveyed maximum velocity of flow passing through the stream was 2.87m/sec, 78.0 of the designed one(3.68m/sec). 9 The surveyed run-off capacity of the stream was $49.51m^3/sec$, 53% of the designed one ($93.5m^3/sec$).

  • PDF

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF