• 제목/요약/키워드: cross-section size

검색결과 426건 처리시간 0.025초

응력-침투 연계 해석에 의한 필 댐의 최적 설계

  • 박춘식;이준석;김종환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.862-870
    • /
    • 2010
  • This thesis has been researched on optimized design method for the total cross section of embankment considering the fact that the size of embankment cross section is directly related with economic efficiency when dam designing. In general, embankment cross section of fill dam is either determined by cohesion and angle of internal friction, a strength parameter of embankment materials or by permeability of embankment. Therefore the size of embankment cross section depending on strength parameter of embankment materials was determined by using MIDAS-GTS program through stress-seepage coupled analysis at the time of fill dam design. As a result, determination of embankment cross section was more affected by the size of central core and permeability rather than by slope stability by shear strength and it was revealed that in case of embankment height being over 20m, stability against infiltration and slope action could be secured only when embankment slope is at least over 1:2.5. In addition, it was also revealed that in case of making the size of central core exceeding specification standard, total cross section of embankment could be reduced considerably and at the time of embankment design, adequate size and appropriateness of embankment cross section could be determined with referring the table suggested by this study.

  • PDF

미세 펀칭 형상이 적층형 안테나 특성에 미치는 영향 (Effect of the shape of the micro punching on the stacked antennas characteristics)

  • 홍주표;한재남;정형욱;윤성만
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.71-74
    • /
    • 2007
  • Substitution of the stacked antenna for the normally pressed antenna in the mobile phone was tried for the purpose of decreasing its size. However, reduced size resulted in the difficulties obtaining the targeted characteristics with the bandwidth over 70MHz. The cross-section of the vias in the low temperature co-firing ceramics process was studied to find out effects on the bandwidth characteristics. Circular and rectangular cross-section of the via beneath different types of antenna patterns were simulated. Better bandwidth characteristics were acquired for the larger diameter of the circular section and for the rectangular section as the cross-section area increased. From the viewpoint of the shape of the cross-section, rectangular area showed better characteristics than the circular area with the same longest length in the cross-section.

  • PDF

장주기파에 효율적인 부유식방파제에 대한 연구 I: 사다리꼴과 요철 단면형상에 대하여 (A Study on the Long-Wave Effective Floating Breakwater I: On Trapezoid and Prominence Cross Section)

  • 김도영;안용호
    • 한국해양공학회지
    • /
    • 제15권1호
    • /
    • pp.7-11
    • /
    • 2001
  • In this paper, trapezoid sections and prominence sections were examined to improve the performance of floating breakwater in long waves. The linear potential theory is used and the boundary element method with a matching boundary is employed for numerical computation. The effects of the side slope of the trapezoid section and the geometry ratio of the prominence section on the floating breakwater were examined. It was found that trapezoid sections show lower transmission coefficients than the rectangular sections in the long wave range. In prominence sections the size of the sides are more important than the size of the top. Proper choices of the pontoon type geometry may move the local minimum point of the wave transmission coefficient toward the longer wave ranges and improve the performance of the floating breakwater in the long wave range for a given wave period.

  • PDF

고속화에 따른 철도터널의 단면규모 결정요소에 대한 고찰 (A Study on the Principal Factors of Rail Tunnel Cross-Section Design due to High Speed)

  • 류동훈;이현정;한상연;신현일;정병률;송충렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1487-1501
    • /
    • 2011
  • Recently, fast-growing up railway transportations. Because, regional traffic congestion problem solving and a period of rapid expansion to meet the demand of industries. In addition the government also suggest to new paradigm for the future 'Low Carbon, Green Growth' is presented as a new national vision. To meet the social needs and the time demands, Last of the railway increase very long tunnels and huge deep tunnels. Especially this trend accelerated high speed up in the tunnel, the revision of design criteria and research challenges are being actively improved. Mainly in the tunnel cross-section was under the control of the vehicle train speed 150km/hr by the construction of the vehicle cross-section of the tunnel. More than 200km/hr rail tunnel depending on the vehicle's speed caused the tunnel to the pressure fluctuations will be governed by the aerodynamic changes. Considering the economy to ensure the optimum cross-section of the railway tunnel to the description scheme is selected cross-section of the railway tunnel to determine the size domestic or international railway tunnel for the elements((based on fast Algorithm design criteria, the center line spacing, streetcar line, cross-sectional shape, sectoral issues, such as interface and aerodynamics) based on design practices and to review results. In this study, to propose guidelines depending on the size of a railway tunnel cross section for the size of the determining reasonable factors when designing the railway tunnel and cost-effective standards guidelines.

  • PDF

착의 단면 중합도 분석에 의한 길 원형의 여유률 산출 - 3차원 형상 계측기에 의한 - (Computation of Ease-Rate in Basic Bodice Pattern by Analysis of Multiple Cross Section, Using 3-D Measuring Instrument)

  • 심규남;김진선;이원자
    • 한국의류산업학회지
    • /
    • 제2권4호
    • /
    • pp.360-365
    • /
    • 2000
  • This research is the trial for the computation of the ease-rate for the bodice pattern. The result of the analysis about the cross section figures of garment space by using a 3-D measuring instrument is that: The garment space of each bodice by each body size is definite. In the figure of cross section of the basic lines, an area of cross section of garment space and length of cross section of garment space are not increased in proportion to an area of cross section of the body. The ease rate is the same no matter that flat-rate of the body is same or different. The ease-rate is computed by length of cross section of garment space that is in proportion to the radius of the body.

  • PDF

A Review on Fluorescent Lamps Having Noncircular Cross-sections

  • Ko, Jae-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1165-1168
    • /
    • 2005
  • We review discharge characteristics of fluorescent lamps having noncircular cross sections. The developmental and theoretical history of noncircular cross-section lamps is summarized chronologically. In particular, discharge characteristics of noncircular cross-section lamps will be summarized and analyzed including plasma contraction, electron temperature, and ambipolar diffusion loss, which might give us some insights into the way to develop more efficient and uniform flat fluorescent lamps, which have recently arisen as a new light source of large-size backlight units for LCD TV applications.

  • PDF

Multiscale modeling for compressive strength of concrete columns with circular cross-section

  • Wu, Han-liang;Wang, Yuan-feng
    • Computers and Concrete
    • /
    • 제15권6호
    • /
    • pp.865-878
    • /
    • 2015
  • In order to construct a multiscale model for the compressive strength of plain concrete columns with circular cross section subjected to central longitudinal compressive load, a column failure mechanism is proposed based on the theory of internal instability. Based on an energy analysis, the multiscale model is developed to describe the failure process and predict the column's compressive strength. Comparisons of the predicted results with experimental data show that the proposed multiscale model can accurately represent both the compressive strength of the concrete columns with circular cross section, and the effect of column size on its strength.

Static stability analysis of axially functionally graded tapered micro columns with different boundary conditions

  • Akgoz, Bekir
    • Steel and Composite Structures
    • /
    • 제33권1호
    • /
    • pp.133-142
    • /
    • 2019
  • In the present study, microstructure-dependent static stability analysis of inhomogeneous tapered micro-columns is performed. It is considered that the micro column is made of functionally graded materials and has a variable cross-section. The material and geometrical properties of micro column vary continuously throughout the axial direction. Euler-Bernoulli beam and modified couple stress theories are used to model the nonhomogeneous micro column with variable cross section. Rayleigh-Ritz solution method is implemented to obtain the critical buckling loads for various parameters. A detailed parametric study is performed to examine the influences of taper ratio, material gradation, length scale parameter, and boundary conditions. The validity of the present results is demonstrated by comparing them with some related results available in the literature. It can be emphasized that the size-dependency on the critical buckling loads is more prominent for bigger length scale parameter-to-thickness ratio and changes in the material gradation and taper ratio affect significantly the values of critical buckling loads.

강재의 단면형상에 따른 내화피복두께 산정 연구 (Study on the Determination of Fire Protection Thickness based on Section Factor)

  • 정청운;지남용;권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.139-142
    • /
    • 2003
  • Traditionally, the thickness of fire protection materials of structural elements such as beam and column have been decided by fire test using the predominant steel section of $H-300{\times}300{\times}10{\times}15$ for column and $H-400{\times}200{\times}8{\times}13$ for beam in Korea. But this way of determination of fire protection thickness yields very unduly results. Because the temperature-increment rate of structural steel elements depends mainly on magnitude of their cross-areas. In general, the thicker size of cross-areas for structural elements, the lower temperature shows up. It had already proved that the fire protection thickness only depends on the size of cross-areas and the fire protection method for three-fide or four-side exposed conditions in European countries, the United State of America and so on. To demonstrate there would be differences among various cross-areas for structural elements, we conducted several fire tests with full-scale specimens of beams and columns. For the determination of critical temperature for steel section when the fire resistant performance is needed to be decided, we conducted with a loaded fire test for beam and column, respectively. The small column in 1.0 meter length and beam in 1.5 meter length were used in order to deprive the rational fire protection thickness of structural elements such as beam and column, respectively. After test, we could obtain there were significant temperature lass between higher cross-areas and lower cross-areas. The critical temperature of steel as a criterion is used 538$^{\circ}C$ for column and 593$^{\circ}C$ for beam which is from ASTM E 119 because we don't make provisions as critical temperature by elements. We could consider that the best way of determination of fire protection thickness is using the following multi-regression equation which was deprived from several fire tests using the concept of section factor, FR(column) = 0.17 +5191.49t A/Hp + 40.77t, FR(beam) = 0.25 +6899.31t A/Hp + 32.60t(where, FR means fire resistant time, t means thickness, A means cross-area and Hp means heated parameter).

  • PDF

단면크기 및 피복두께 변화에 따른 철근콘크리트 기둥의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performance of the Reinforced Concrete Columns According to the Cross Section Size and Depth of Concrete Cover)

  • 조경숙;여인환;조범연;김흥열;민병렬
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.78-84
    • /
    • 2011
  • 최근 콘크리트 내화 연구는 대부분 고강도 콘크리트의 내화성능 확보에 많은 초점이 맞추어져 있다. 그러나 국내의 콘크리트 수요를 살펴보면 40MPa 이하의 일반강도 콘크리트의 수요가 전체 콘크리트 수요량의 대부분을 차지한다. 따라서 고강도 콘크리트의 내화성능에 대한 연구뿐만 아니라 일반콘크리트의 내화성능에 관한 연구도 필요하다. 본 연구에서는 40MPa 콘크리트 기둥을 대상으로 콘크리트 피복 두께와 단면크기를 변수로하여 내화성능을 평가하였으며, 연구 결과 단면크기가 커질수록, 피복두께가 두꺼워질수록 내화성능은 향상되는 것으로 나타났다.