• 제목/요약/키워드: cross correlation coefficient

검색결과 520건 처리시간 0.031초

노령출산에 관한 연구 (A Study on Childbrith in Late Maternal Age)

  • 한예영
    • 한국보건간호학회지
    • /
    • 제8권2호
    • /
    • pp.101-113
    • /
    • 1994
  • Maternity means all the women who are capable to conceive. In the aspect of health and medical care. however. it means the women who are now in pregnancy or have already given birth to a baby or are in a period of being recoverd from physiological changes occurred by pregnancy. According to the rapidly changing social structure. both the Quality and Quantity of the capacity of childbirth experienced by women are changing. Our society. having established a great economical growth by virtue of the highly developing and growing industrialization and urbanization. stimulates the women's advance into society and thereby increasing the number of employed women. When the women's participation in society is increased. their age of marriage is also affected. Which means there are a decrease of the capacity of childbirth in terms of quantity and a trend for women to have less children and to deliver a baby in their old age in terms of quality. On the contrary. since the number of multipara who want to have a baby in their old age is increasing. as a counter functional effect to the political project of decrease of a birth rate. concern has been focussed on childbirth in old age in the present study. And also such kind of the childbirth may be danger to the health of both mother and baby. Therefore the present study intended to provide some basic data of health education in the part of the health management of both mother and baby in the general hospital. based on understanding the realities of childbirth in. old age and things related to them. To achieve such a purpose of the present study. an analytical study by means of SPSS. was done using the data of 269 clinical records on both the newborn .babies and their mothers who had been supported by public general hospitals located in Seoul for 3 years from Jan. 1. 1991 to Dec. 31. 1993. Some significant results from the analytic study are as follows: 1. It appeared that the average age of normal. natural delivery was 33.8 years old and the average age of delivery through the cesarean operation was 35.4 years old. 2. It appeared that danger factors to childbirth women were types of the delivery and placental extrusion and danger factors to newborn babies are not so outstanding. 3. It appeared that the variables of the childbirth capacity which showed a significant difference according to each age group of women were the number of pregnancy. number of still birth, and number of existing children. That is. the age group of 'more than 35 years' had more frequency of experience In all 3 variables than the age group of 'less than 35 years'. 4. It appeared that the variables of the childbrith capacity which showed a significant difference a according to the sex of a newborn baby were number of pregnancy, number of still birth, and number of existing children. That is, the age group of 'more than 35 years' had more frequency of experience in all 3 variables than the age group of 'less than 35 years'. 5. It appeared that the health index of newborn babies which showed a significant difference was only 5 minute APGAR. That is, the health index 9.46 in the age group of 'more than 35 years' was less than an index of 9.72 in the age group of 'less than 35 years'. 6. Since a counter correlation of -0.10, as Pearson Correlation Coefficient, was showed between the age of childbirth mothers and the weight of newborn babies, it indicated that the higher age of childbirth woman, the lesser the weight of newborn baby. 7. It appeared that the number of women who had confirmed the sex of their baby before their delivery were 45 women, $67.2\%$ of total 67 women who had delivered a baby. and the expected sex by women in childbed was male with $73.1\%$ of total childbirth women expecting male birth and with their expression of feeling of female delivery. very regretful' by $39.3\%$ of total childbirth women. The results as shown above may indicate that instead of the possibility of danger to both the mother delivering a baby in old age and the baby delivered, the expectation of getting a son motivates childbirth in old age. As a conclusion, in a dimension of general hospital as well as national reform. it is required that a program of health education for childbirth in late maternal age have to be developed in the part of the health management of both mother and baby in the near future.

  • PDF

위성 자료와 수치모델 자료를 활용한 스태킹 앙상블 기반 SO2 지상농도 추정 (Monitoring Ground-level SO2 Concentrations Based on a Stacking Ensemble Approach Using Satellite Data and Numerical Models)

  • 최현영;강유진;임정호;신민소;박서희;김상민
    • 대한원격탐사학회지
    • /
    • 제36권5_3호
    • /
    • pp.1053-1066
    • /
    • 2020
  • 이산화황(SO2)은 대기 중 화학 반응을 통해 2차 대기오염물질을 생성하는 전구체로, 주로 산업활동이나 주거 및 교통 활동 등을 통해 배출된다. 장기간 노출 시 호흡기 질환이나 심혈관 질환 등을 유발하여 인체 건강에 부정적인 영향을 미칠 수 있기 때문에 이에 대한 지속적인 모니터링이 필요하다. 우리나라에서는 SO2에 대해 관측소 기반의 모니터링이 수행되고 있으나 이는 공간적으로 연속적인 정보를 제공하는 데에 한계가 있다. 따라서, 본 연구에서는 위성자료와 수치모델 자료를 융합하여 일별 13시를 타겟으로 하는 1 km의 고해상도로 공간적으로 연속적인 SO2 지상농도를 산출하였다. 2015년 1월부터 2019년 4월까지의 기간 동안 남한 지역에 대하여 스태킹 앙상블 기법을 이용하여 SO2 지상농도 추정 모델을 개발하였다. 스태킹 앙상블 기법이란 여러가지 기계학습 기법을 두 단계로 쌓는 방식으로 융합하여 단일 모델 대비 더 향상된 성능을 도출하는 방법이다. 본 연구에서는 베이스 모델로는 RF (Random Forest)와 XGB (eXtreme Gradient BOOSTing) 기법이, 메타 모델로는 MLR (Multiple Linear Regression) 기법이 사용되었다. 구축된 모델의 교차검증 결과 메타 모델은 상관계수(R) = 0.69와 root-mean-squared-error(RMSE) = 0.0032 ppm의 결과를 보였으며 이는 베이스 모델의 평균 대비 약 25% 향상된 안정성을 보였다. 또한 모델 구축에 사용되지 않은 기간에 대한 예측 검증을 수행하여 모델의 일반화 가능성을 평가하였다. 구축된 모델을 이용하여 남한 지역의 SO2 지상농도 공간분포를 분석한 결과 일반적인 계절성과 배출원의 변화를 잘 반영하는 패턴을 보임을 확인하였다.

적외선 분광스펙트럼 및 기체크로마토그라피 분석 데이터의 다변량 통계분석을 이용한 대두 종자 지방산 함량예측 (Simultaneous estimation of fatty acids contents from soybean seeds using fourier transform infrared spectroscopy and gas chromatography by multivariate analysis)

  • 안명숙;지은이;송승엽;안준우;정원중;민성란;김석원
    • Journal of Plant Biotechnology
    • /
    • 제42권1호
    • /
    • pp.60-70
    • /
    • 2015
  • 본 연구의 목적은 적외선 분광스펙트럼 데이터를 이용하여 대두 종자내의 지방산 함량을 동시에 예측할 수 있는지 여부를 조사하기 위한 것이다. 총 153종의 대두(Glycine max Merrill) 종자로부터 적외선 분광스펙트럼 및 지방산의 함량을 기체크로마토그라피 분석을 통하여 확인하였다. 적외선 분광스펙트럼 조사결과 대두는 단백질이나 아미노산의 amide bond region ($1,700{\sim}1,500cm^{-1}$), 핵산이나 인지질의 phosphodiester groups ($1,500{\sim}1,300cm^{-1}$) 그리고 탄수화물 등 다당류의 sugar region ($1,200{\sim}1,000cm^{-1}$)에서 계통별로 큰 차이가 이루어짐을 알 수 있었다. 총 29라인의 대두 계통별 시료로부터 지방산 함량을 조사한 결과 총 지방산의 함량은 건조 시료 0.1 g 당 $185.57{\mu}g$에서 $325.9{\mu}g$으로 계통간에 차이가 있었음을 알 수 있었으며 평균 함량은 $244.48{\mu}g$이었다. PLS regression 분석을 이용하여 총 5개 지방산(팔미틱산, 스테아릭산, 올레익산, 리노레익산 그리고 리노레닉산) 함량 예측 calibration models의 실측 검증 결과, 팔미틱산($R^2=0.8002$), 올레익산($R^2=0.8909$) 그리고 리노레익산($R^2=0.815$)은 회귀분석 상관계수가 0.8 이상으로 정확도 높음을 알 수 있었다. 그러나 스테아릭산($R^2=0.4598$)과 리노레닉산($R^2=0.6868$)의 경우 상관계수가 0.7 이하로 상대적으로 예측정확도가 낮음을 알 수 있었다. 본 연구에서 확립된 기술은 지방산의 조성 변환을 통하여 새로운 대두 품종 개발을 위한 계통선발 과정에서 매우 효율적인 수단으로 활용이 가능할 것으로 사료된다. 더 나아가 본 기술은 대두는 물론 대두 유래 농산물이나 식품의 품질 검증 수단으로 활용이 가능할 것으로 기대된다.

한국판 역학연구 우울척도 개정판(K-CESD-R)의 표준화 연구 (Validation of the Korean version of Center for Epidemiologic Studies Depression Scale-Revised(K-CESD-R))

  • 이산;오승택;류소연;전진용;이건석;이은;박진영;이상욱;최원정
    • 정신신체의학
    • /
    • 제24권1호
    • /
    • pp.83-93
    • /
    • 2016
  • 연구목적 역학연구 우울척도 개정판은 우울 증상을 평가하는 데에 유용성이 입증된 척도로 알려져 있으며 '정신장애의 진단 및 통계 편람 제4판(DSM-IV)'에 기술되어 있는 주요우울장애의 주요한 우울 증상들을 포괄하고 있다. 이 연구에서는 한국판 역학연구 우울척도 개정판을 제작하여 척도의 신뢰도, 타당도와 특성을 평가하고자 하였다. 방 법 DSM-IV의 진단기준에 근거한 MINI를 사용하여 주요우울증, 기분부전증, 달리 분류되지 않는 우울장애로 진단된 48명의 환자군과 48명의 정상 대조군이 연구에 참여하였다. 연구 참여자들은 한국판 역학연구 우울척도 개정판, 몽고메리-아스버그 우울증 평가척도, 우울증 선별척도, 단축형 우울증상 평가 척도, 상태-특성 불안척도를 포함한 척도검사를 시행하여 교차 검증하였다. Cronbach's alpha 계수, Pearson 상관계수, 주성분 분석, Receiver Operating Characteristic(ROC) 곡선, 최적 절단점 산출을 위한 통계분석을 시행하였다. 결 과 한국판 역학연구 우울척도의 Cronbach's alpha 계수는 0.98이었으며, 한국판 역학연구 우울척도 개정판의 총점은 본 연구에서 시행하였던 다른 우울 및 불안척도의 점수와 높은 상관 관계를 보였다. 주성분 분석에서는 두 요인이 전체 분산의 76.29%를 설명하였으며, ROC 곡선을 이용하였을 때, 한국판 역학연구 우울척도 개정판의 최적 절단점은 13점이었다. 결 론 본 연구는 한국판 역학연구 우울척도 개정판의 표준화를 위한 첫 번째 연구로, 한국판 역학연구 우울척도는 우울 증상을 평가하는데 있어 신뢰성 있고, 타당한 척도임을 밝혔다. 또한 이 척도가 진료 및 역학 연구에서 유용한 선별검사 도구로 사용될 수 있을 것으로 기대한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

수도원연품종간잡종에 있어서의 생육일수와 불임에 관한 연구 (Studies on the growth duration and hybrid sterility in remote cross breeding of cultivated rice)

  • 허문회
    • 한국작물학회지
    • /
    • 제4권1호
    • /
    • pp.31-71
    • /
    • 1968
  • 수도원연품종간 교배육종에 있어서 지리적 생태품종 간의 잡종 초기 세대의 생육일수와 불임성의 변이에 관한 지견을 얻고자 대표적인 Indica와 Japonica 그리고 그중간형인 Beaumont 품종과 Ponlai등 7개 품종을 상호 교배하여 IRRI(북위 $14^{\circ}$17')에서 $F_1$ 을 10시간 및 14시간 조명하에서 $F_2$를 단일건계의 자연일장하에서 재배하고 수원(북위 $37^{\circ}$16')에서도 $F_1$을 10시간 및 자연일장하에, $F_2$$F_3$을 자연일장하에 각각 재배하고 출수일수 및 불임율을 조사 연구하였다. 1. 출수일수 : 1) $F_1$들은 10시간 단일하에서는 조생이 만생에 대해 우성 내지 초월성으로 나타났고 14시간 장일하에서는 우성 내지 불완전 우성으로 나타났는데 IRRI와 수원에서 모두 같았다. 2) IRRI에서 단일시기에 재배된 $F_2$는 조생이 만생에 대해 불완전우성이며 분리는 연속적이었다. 수원에서 조기재배된 $F_2$는 대부분의 조합에서 조생이 불완전우성이거나 중간성으로 적기 재배된 $F_2$는 대부분의 조합에서 만생이 불완전 우성이거나 중간성으로 나타났다. 3) 극단의 만생간의 조합에 있어서도 유효 출수 가능한 초월분리 개체가 있었다. 4) 기본영양생장성이 긴 품종들의 조합에서는 변이의 폭이 넓었고 신품종의 평균과 친계열평균 변이계수와에는 높은 상관이 있었다. 5) $F_1$이나 중간친으로 $F_2$집단의 평균 출수일수를 예측할수 있으며 $F_2$평균과 $F_3$계통 평균과에도 높은 상관이 있었으나 IRRI에서 재배된 $F_2$개체와 수원에서 재배된 $F_3$계통간의 상관은 없었다. 6) IRRI에서 재배된 $F_2$와 수원에서 재배된 $F_3$계통간에는 통계학적으로 조정된 heritability가 매우 낮아서 출수일수에 관한 선발의 효과는 단일감응성 품종에 대해서는 기대하기 어렵다. 7) $F_1$$F_2$의 평균 출수일수는 정역교배간에 차가 없거나 극소하였다. 8) 잡종의 단일감응성 측정치를 친계열별 평균과 이 평균으로 부터의 편차로 구분 계산하여 단일감응성에 기여하는 양친들의 효과에 따라 친품종을 감응성품종과 비감응성 품종을 구분 할 수 있었다. 9) 단일감응성은 $F_1$이 양친보다 높으며 $F_2$, $F_3$으로 세대가 진전함에 따라 낮아진다. 10) 온도차에 따른 $F_1$의 출수일수 반응은 양친품종보다 작으며 장일과 단일하에서의 온도반응의 차이는 품종에 따라 차이가 있었다. 2. 불임율 : 1) IRRI에서도 수원에서도 다같이 $F_1$의 불임은 조합에 따라 차가 크며 친품종의 불임율과 상관이 없었다. 또 10시간 단일하에서는 14시간 장일하에서 보다 불임율이 높았다. 2) $F_1$에서 불임이 높았던 조합이 $F_2$에서도 높았으며 단일감응성이 높은 품종과 고온감응성이 높은 품종간의 조합에서 불임이 높았고 그 분산의 폭도 넓었다. 3) $F_2$ 평균은 $F_1$보다 낮으며 $F_3$계통들의 평균은 $F_2$평균보다 낮아 세대가 진전됨에 따라 불임율이 낮아지며 $F_3$에서는 조합간의 차가 현저하지 못하게 되었다. 4) $F_2$에 있어서는 화분불임과 종실불임간에 상관이 미약하였다. 5) $F_1$$F_2$평균의 불임율에는 정역교배간에 차가 없었다. 6) 잡종 불임을 잡종강세에서와 같이 Griffing의 방법에 따라 조합 능력 검정을 한 결과 SCA 효과는 GCA효과보다 컸는데 SCA효과가 특히 큰 것은 감광성이 높은 품종과 감온성이 높은 품종간의 조합들이였다. 7) IRRI에서 재배된 $F_2$와 수원에서 재배된 $F_3$과에는 불임에 관해 상관이 낮으며 $F_3$에서는 $F_2$에서보다 불임율이 낮아졌다. 8) $F_2$에 있어서 출수일수와 불임율과에는 상관이 거의 없었다.

  • PDF

소맥(Triticum aestivum L. em Thell)의 출수기 유전에 관한 연구 (Studies on the Inheritance of Heading Date in Wheat(Triticum aestivum L. em Thell))

  • 조장환
    • 한국작물학회지
    • /
    • 제15권
    • /
    • pp.1-31
    • /
    • 1974
  • 소맥의 조숙품종육성을 위하여는 춘파성품종의 조숙인자를 추파성품종에 도입하는 것이 중요한 과제이므로 춘추파성 소맥품종의 일장과 온도조건에 따른 출수반응 및 출수기를 지배하는 생리적 요인의 구명과 출수기의 유전에 관한 지견을 얻고저 본실험을 실시하였다. 수원 작물시험장 전작포장 및 온실에서 1970년부터 조숙품종 Yecora F70, 중숙품종 수계 169호, 육성 003 만숙품종 장광, Bezostaia, Sturdy, Blueboy 등 8개품종을 상호교배하여 1972년부터 1973년에 온실 및 초자실을 이용하여 양친과 Diallel cross F$_1$을 고온장일, 고온단일, 저온장일, 저온단일의 4처리조건 및 포장조건에서 3조합의 F$_1$, F$_2$, BC$_1$, BC$_2$ 및 양친들은 고온단일조건에서 F$_1$, F$_2$ 9조합 및 그 양친은 포장에서 각각 재배 실험하였다. 그 결과를 요약하면 다음과 같다. 1. 춘화 처리후의 주요엽수는 일장 및 온도조건에 관계없이 일정하였으나 주간의 출엽속도에만 영향을 주었으며 춘파성품종은 추파성품종보다 주간엽수가 적었다. 2. 지엽전개일수의 일장 및 온도반응은 출수속도에 의하여 결정되며 일장과 온도에 따른 출엽속도의 차이는 하위엽보다 상위엽에서 컸다. 3. 춘화처리후의 출수기에 대한 생리적 요인은 일장반응과 순수조만생이며, 출수일수의 품종간 변이는 고온단일에서 가장 크고 포장조건에서 가장 적었으며 고온장일, 저온장일, 저온단일을 비슷하였다. 4. 일장차이에 의한 출수일수의 품종간 반응은 장광, Parker가 크고, Yecora F70, 수계 169 호 등 기타 품종들은 비교적 적었으며, 장광, Parker는 단일이 의하여 출수일수가 크게 지연되는 감광성 품종이었다. 5. 일장반응은 온도의 영향을 크게 받고 출수일수의 품종간차이는 저온일 빼보다 고온일 때 현저히 나타났다. 6. 온도차이에 의한 출수일수의 품종간 반응은 비슷하였으며, 어떠한 품종이라도 고온에 의하여 출수가 촉진되고 저온에 의해서 지연되었다.7. 출수일수에 대한 유전은 일장 및 온도조건이 변하여도 조숙은 만숙에 대하여 부분우성이었으며, 우성의 정도는 단일에서 크고 장일에서 적었다. 8. 고온장일조건에서 출수일수의 품종간 차이는 수수조만성의 차이라고 할 수 있으며, 춘파성품종인 Yecora F70은 추파성품종에 대하여 우성정도가 컸고 추파성품종간에는 우성정도가 없거나 적었다. 이때의 유효 우성 유전자수는 1쌍의 대립유전자에 의해서 지배되나 다소의 미동유전자가 관여되었다. 9. 출수일수에 관여하는 비감광성은 감광성에 대하여 우성단인자차에 의하여 지배되었고 저온조건에서는 단일감응성의 발현정도가 둔화 또는 억제되었다. 10. 순수 조만성과 단일감응성은 모두 조숙이 만숙에 대하여 부분우성으로 표현되었다. 11. 출수기에 관여하는 감온성의 품종간반응은 대립유전자 및 비대립유전자의 지배를 받으며 같은 대립유전자를 가진 품종군에서는 비감온성이 감온성에 대하여 우성으로 표현되나 일장 및 순수 조만성보다는 그 정도가 미미하다. 12. 장광과 수계 169호 사이에는 감광성에 관여하는 1쌍의 대립인자 ee와 EE에 의하여 조만이 결정되었고, 장광과 Yecora F70사이에는 ee, enen과 EE, EnEn의 2쌍의 대립인자에 의하여 지배된다고 추정되었다. 이때 EE와 EnEn는 조숙방향에 상가적으로 작용하여 단일조건하에서는 EE의 효과가 EnEn의 효과보다 크다. 장일 조건하에서는 EE의 효과는 나타나지 않고 EnEn효과만 발현된다. En과 en 사이에 우열관계는 E와 e 사이보다 적고 상가적 작용을 하고 있다고 본다. 13. 본 실험의 포장조건에서는 2개정도의 우성주동유전자를 가정할 수 있으나 생육초기의 저온단일과 생육후기의 고온장일의 영향으로 2개의 우성유전자 표현이 불확실하며 F$_2$분리에 있어서는 일장 및 온도의 영향과 미동유전자의 영향으로 연속변이를 하였다. 14. 출수일수의 유전력은 0.51-0.72로서 어느 조건에서나 높은 경향으로 초기세대의 선발효과가 큰 것으로 인정되었으며, 환경에 의하여 다소의 차이가 있어 장일보다는 단일에서 유전력이 컸고, 저온보다는 고온에서 큰 경향이었다. 또한 감광성의 유전력은 0.86-0.76으로 컸으나 온도효과의 유전력은 적었다. 15. 출수기가 빨라지므로서 1수입수, 천입중, 수량이 낮아지는 상관관계를 보여 조숙다수성 품종선발이 어렵다는 결과를 보였으나 수수와는 부의 상관(유의성은 없음)을 보여 조숙품종으로서 수수형 품종을 선발하면 수량을 올릴수 있는 약간의 가능성도 보였다.

  • PDF

단수수(Sorghum vulgare PERS) 품종의 생태변이 및 유용형질의 유전에 관한 연구 (Studies on Ecological Variation and Inheritance for Agronomical Characters of Sweet Sorghum Varieties (Sorghum vulgare PERS) in Korea)

  • 손세호
    • 한국작물학회지
    • /
    • 제10권
    • /
    • pp.1-43
    • /
    • 1971
  • 실험 I. : 본 실험은 단수수에 대하여 재배시기를 이동함에 따르는 실용 제형질의 변화를 구명하기 위하여 1968~1969년까지 2개년에 거쳐 작물시험장 특용작물 연구실(수원)에서 시행되었으며 품종은 조만생, 초형, Syrup형, Sugar형 등 생태적 특성을 달리한 17개품종이 공시되었으며 묘종기 양년 모두 4월 5일부터 8월 25일까지 20일 간격으로 8회에 걸쳐 파종하여 조사한 바 그 결과를 요약하면 다음과 같다. 1. 발아기(발아일수)는 파종기를 앞당겨 저온하에 파종하면 발아에 소요되는 일수가 많고 파종기가 늦어서 기온이 상승됨에 따라 발아 일수가 직선적으로 단축되다가 8월 25일 이후의 파종부터는 다시 지연되는 경향이었다. 발아기간의 일평균온도와 발아일수간에는 높은 부상관관계가 있으나 이와는 반대로 발아일수와 적산온도간에는 고도의 정상관이 인정되었다. 2. 파종기의 지연에 따라 출수일수는 거의 직선적으로 단축된다. 공시된 품종간에 평균출수일수차는 30.2일이란 큰 차이가 있었다. 이들을 10일간격으로 조, 중, 만생군으로 구별하면 조생군은 평균출수일수가 78.5$\pm$4.5일범위에 속하고 중생군은 88.5$\pm$4.5일, 만생군은 98.5$\pm$4.5일로 되었다. 출수단축한계 종종기는 조생군이 제VI-VII파종기인 7월 15일$\pm$8월 5일까지이고 중생군은 제VI파종기인 7월 15일까지, 만생군은 제IV파종기인 6월 5일까지이었다. 3. 파종기(x)와 출수까지의 일수(y)와의 회귀직선식 y=a+bx의 손수(출수까지의 일수의 단축율)와 평균출수까지의 일수와는 고도의 정상관관계가 있었다. 4. 파종에서 출수기까지의 생육경과에 있어서 일평균기온이 높을수록 출수일수가 단축되어 조생종은 24.2$^{\circ}C$에서, 중생종은 23.8$^{\circ}C$에서, 만생종은 22.9$^{\circ}C$에서 최대단축율을 보이었고 따라서 출수전 30일간의 평균기온이 약 22$^{\circ}C$부터 $25^{\circ}C$에 이르기까지 가속적으로 출수소요일수가 단축되다가 그뒤 약 21$^{\circ}C$이하가 됨에 따라 다시 지연되는 경향이었다. 5. 초장의 절대치는 품종간에 차이는 있으나 비교적 조파구간에는 초장에 큰 변이가 없었고 파종기가 늦어짐에 따라 짧아졌다. 초장의 신장속도는 파종기가 늦어짐에 따라 현저하게 빨라지고 특히 조생종이 만생종보다 더욱 가속적인 경향이었다. 따라서 최고초장과 최저초장과의 절대치의 차이는 조생종일수록 적고 만생종일수록 큰 격차를 보이었다. 6. 간직경에 있어서도 만생종은 일반적으로 조기파종할수록 굵고, 조생종과 중생종은 4월 25일 파종기가 가장 굵은 편이며 이보다 파종기가 지연 가늘어지는 경향이었다. 7. 간중은 품종의 조만생에 따라 약간의 차이는 있으나 대체로 적기(4월 25일~5월 15일)보다 조기 혹은 만기 파종하면 작아지나 파종기 이동에 따른 간중의 변화는 품종의 조만성에 따라 양상을 달리하여 조생종은 4월 25일 내외, 중생종은 4월 25일~5월 15일 내외, 만생종은 4월 5일~5월 15일 내외의 파종기에서 최고수량에 달하고 이후 직선적으로 감소하였다. 8. Brix 도는 품종에 따라 절대치가 다르며 또한 파종기가 5월 15일 이후로 늦어짐에 따라 직선적으로 감소되어 파종기(x)와 Brix 도(y) 간에 고도의 부상관관계를 볼 수 있었다. 9. 출수후 40~45일경의 절간부위별 Brix 도는 상부 제 1~제3절간 부위가 최고에 달하고, 제4절간부터 서서히 낮아지다가 지상 제2절부위에 가서 다시 약간 높아지는 경향이었다. 그러나 출수전까지는 이와 반대의 경향이었다. 10. 간중당분에 대한 파종기별 축적상황은 파종기가 지연됨에 따라 거의 직선적으로 낮아지며 품종에 따라 차이는 있으나 6월하순 이후의 파종기는 당원료작물로서 거의 무가치한 낮은 함량을 나타내었다. 11. Brix도 및 간중당분은 출수기부터 축적이 시작되어 출수후 약 40~45일에 최고에 달하고 순당율도 같은 경향으로 생육의 진전과 더불어 높아져서 순당율과 Brix 도간, 순당율과 간중당분간에 각각 높은 정의 상관관계가 존재한다. 12. 가제당량과 파종기간의 관계를 보면 중생종과 만생종은 4월 25일, 중생종은 5월 15일 파종기가 최고에 달하고 이보다 파종이 지연됨에 따라 급격히 감소되는 경향으로 파종기(x)와 가제당량(y)사이에 1% 이상의 높은 부의 상관을 보았다. 13. 파종기 및 제형질간의 상호관계를 보면 파종기가 지연됨에 따라 발아일수, 발아기간의 적산온도, 출수일수, 출수일수까지의 적산온도, 초장, 간직경, 간중, Brix 도, 간중당분, 순당율, 가제당량 등은 모두 고도의 부상관 및 회귀관계이었고 출수일수(x)와 Brix도, 당도, 순당율, 가제당량, 초장, 간장(y)등 간, Brix 도(x)와 순당율, 가제당량, 간중(x)과 가제당량(y)간, 또한 출수시의 일장(x)과 Brix 도, 출수일수, 당도, 순당율, 가제당량(y) 등 간에는 고도의 정상관을 인정할 수 있었다. 실험 II: 실험 I에 공시된 품종중에서 생태 및 유전적으로 다른 11품종만을 이면교배법에 의하여 교잡된 F$_1$ 및 교배친의 출수기, 간장, 간중, Brix 도 및 Syrup yield 등에 대하여 우성정도, 교배조합능력 및 유전분석을 한 결과를 요약하면 다음과 같다. 1. 출수기는 조, 만숙방향으로 완전 혹은 초월우성인 특정조합이 있기는 하나 대체적으로 중간성 및 부분우성이었고 GCA 및 SCA가 높은 특정조합친을 인정할 수 있었다. 따라서 출수에 관여하는 유전인자의 분배비는 50:50으로 추정되었으며 유전력도 높아서 초기세대부터 선발이 가능할 것으로 본다. 2. 간장은 잡종강세도가 높았으며 장간의 방향으로 초월성인 특정조합도 있으나 완전 혹은 부분우성으로 추정된다. GCA 및 SCA는 일반적으로 높은 편이었으며 관여된 우성 및 열성유전자는 거의 50:50으로 분배되며 유전력은 낮았다. 3. 간중은 대부분 정의 방향(다수)으로 완전우성에 가까운 부분우성으로 작용하나 특정조합에 따라 초월우성인 것과 부분우성인 것이 있었다. GCA와 SCA는 비교적 높은 교배친을 인정할 수 있으며 유전자의 작용방향은 열성유전자가 많이 관여되고 복잡한 분리가 일어날 것으로 추정되며 유전력은 비교적 낮았다. 4. Brix 도에 대한 우성정도 및 방향은 교배조합에 따라 고 Brix 및 저 Brix로 나타났으나 일반적으로 초우성 내지 완전우성으로 나타났고 GCA 및 SCA는 Brix 도가 높은 품종일수록 높은 경향이므로 고당성 육종에는 역시 높은 당분함량을 가진 교배친이 유리할 것으로 추정된다. 5. Syrup 종에 대한 우성정도는 많은 방향으로 초월 혹은 완전우성으로 추정되며 잡종강세도는 대단히 높았다. GCA와 SCA의 관계는 일정하지 않으며 GCA가 높은 품종은 SCA가 낮은 경향이었다. 교배친의 우성대립인자 대 열성대립인자의 빈도는 거의 동수로 나타날 것으로 추정된다.

  • PDF

재배시기 이동에 의한 수도의 생태변이에 관한 연구 -I. 재배시기 이동에 의한 수도의 실용제형질의 변이- (Studies on the ecological variations of rice plant under the different seasonal cultures -I. Variations of the various agronomic characteristics of rice plant under the different seasonal cultures-)

  • 최현옥
    • 한국작물학회지
    • /
    • 제3권
    • /
    • pp.1-40
    • /
    • 1965
  • 본실험은 우리 나라 중부지방에 있어서의 수도의 재배 시기를 이동함에 따르는 실용제형질의 변화를 구명하기 위하여1958~'60년의 3개년에 걸쳐 농업시험장(현 작물시험장) 답작과(수원)에서 시행한 실험으로서 공시품종은 조만성, 초형 등 생태적특성을 달리하는 연산.수원 8002.오조.팔달 및 조광의 5품종을 공시하였으며, 파종기는 3월 2일 ~7월 10일까지를 10일 간격으로 14회에 걸쳐 파종하였고, 또 각 파종기마다 각각 못자리 일수를 30일, 40일, 50일, 60일, 70일 및 8일묘로 하여 이앙하여 실험하였다. 그 결과를 요약하면 다음과 같다. 1. 출수기 : 1) 파종기가 지연됨에 따라서 출수기도 거의 일직선으로 지연되나, 그 정도는 조생종에서 크고 만생종은 작으며, 또 못자리 일수가 길어짐에 따라서 커진다. 2) 출수까지의 일수는 각 품종 모두 파종기의 지연에 따라서 거의 일직선으로 단축하나, 품종에 따라 그 정도의 차이가 있어서 조생종은 단축일수가 작고 만생종이 크다. 그리고 동일품종 내에서도 못자리 일수가 길어짐에 따라 단축일수는 작아졌다. 또 최단축일수에 도달하는 시기도 조생종은 빠르나 만생종은 늦어진다. 또 못자리 일수가 긴 구에서 그 시기는 빨라진다. 품종 및 못자리 일수에 따라 차이가 있으나 어느 시기 이후의 파종기가 되면 단축을 나타내지 않게 되고, 다시 파종기가 늦어지면 한냉한 기후의 영향을 받아 출수일수는 오히려 연장된다. 3) 파종기(X)와 출수까지의 일수(Y)와의 회귀직선식 Y=a+bX의 계수 b(출수일수단축율)와 평균일수일수와는 고도의 상관이 인정되며, 평균출수일수가 클수록, 즉 만생종일수록 파종기의 지연에 의한 출수촉진일수가 컸었다. 4) 어느 품종의 파종기가 동일역일이면 못자리 일수가 극단으로 길지 않은 범위 내에서는(파종기의 지연에 따라서 출수까지의 일수가 직선적으로 단축되는 범위내에서의) 출수일수의 년차간의 변이는 크지 않으므로 목적하는 품종에 대한 수회의 파종기에 걸쳐 출수기의 변동을 조사하여 실험식(파종기와 출수까지의 일수와의 회귀직선식)을 구해 두면 임의의 재배시기에 있어서의 출수기를 추정할 수 있다. 5) 파종기가 3월하순~6월중순, 못자리 일수가 30~50일의 범위에서는 보통기재배에 있어서의 품종의 출수기의 조만을 가지고 그 전후에 해당하는 파종기에 있어서의 각각의 품종에 대한 출수기를 추정할 수 있다. 2. 성숙기 : 6) 출수기가 지연됨에 따라서 성숙한계 출수기의 범위 내에서는 성숙기도 거의 일직선으로 지연된다. 그 정도는 품종 및 못자리 일수의 장단에 의한 차이가 크다. 평균온도의 영향을 받는 범위 내에서는 출수기(X)가 지연됨에 따라서 성숙기간 중의 평균온도(Y)는 그것에 따라서 저하하며 품종간에 차이가 있으나, 전체적으로 보아 양자의 관계를 8월 1일부터 9월 13일까지의 범위에서는 Y=25.53-0.182X의 회귀직선식으로 나타낼 수 있다. 7) 품종의 조만생에 의한 성숙기간에 있어서의 평균온도의 차이가 심하며, 조생종은 최고 28$^{\circ}C$의 고온에서 경과하나 만생종은 22$^{\circ}C$에 불과하다. 8) 성숙기간중의 평균온도(X)와 성숙일수와의 관계는 극히 높은 상관이 인정되며, 양자의 관계를 Y=82.30-1.55X의 회귀직선식으로 표시할 수 있었다. 성숙기간중의 평균기온이 18~28$^{\circ}C$의 범위 내에서는 온도가 1$^{\circ}C$ 상승함에 따라서 성숙일수는 1.55일 단축되는 결과가 되며, 품종별로는 관산이 2.24일로서 단축정도가 컸고, 수원 8002가 0.78일로서 가장 적었다. 따라서 수원지방에 있어서는 평균온도가 18~28$^{\circ}C$의 범위에서는 온도가 상승함에 따라 성숙속도가 빨라진다고 할 수 있다. 9) 각 파종기별로 본 출수까지의 일수(X)에 대한 성숙기간중의 적산온도(Y)와의 관계는 거의 완전한 정의 상관관계가 있고, 성숙기간중의 적산온도는 어느 범위 내에 있어서의 파종기의 이동에 의한 차이는 비교적 작다. 3. 간장 및 수장 : 10) 품종간의 차이는 있으나 비교적 조파가 된 구간에는 간장에 큰 변화는 없으나 계속 파종기가 지연되어 만파가 되면 공시품종 모두 간장의 감소가 뚜렷해졌다. 또 간장의 감소정도는 약묘에서 완만할 뿐만 아니라, 5월 21일~6월 10일 파종과 같이 비교적 만파를 하더라도 별로 감소되지는 않으나, 80일묘와 같은 노숙묘인 때는 보통기재배에서도 급격히 감소한다. 11) 수장의 변화도 간장과 동일한 경향을 보이나 파종기의 지연에 의한 수장의 변화는 30~40일묘에서는 거의 인정되지 않았고, 못자리 일수가 길어지면 수장의 감소가 뚜렷해진다. 4. 수수 : 12) 파종기가 지연됨에 따라서 일정한 시기까지 계속수수는 감소하다가 어느 시기 이후가 되면 새로이 고차분얼의 다량발생으로 수수가 증가한다. 그 시기는 못자리 일수에 따라 차이가 있으며, 30~40 일묘는 5월 31일~6월 10일 파종기인 만파에서 수수가 최대로 감소하며, 70~80일묘의 경우 4월 11일~4월 21일의 파종기에서 이미 수수가 최대로 감소한다. 5. 지경수 : 13) 지경수는 파종기가 지연됨에 따라서 어느 일정한 시기까지는 변화가 없으나, 그 시기가 지나면 수당지경수의 감소가 현저하다. 14) 지경수가 감소되기 시작하는 시기도 30~40 일묘에서는 5월 3일 이후의 파종기가 되나, 80일묘의 경우 5월 31일 파종에서 이미 감소될 뿐만아니라, 5월 31일 파종이 되면 지경수가 3~4개에 불과하였다. 6. 비중과 천입중 : 15) 파종기의 이동에 따라 비중은 서서히 증가하나 어느 시기를 넘으면 급격히 증가하며, 이를 2개의 상이한 회귀직선으로 표시할 수 있다. 16) 이 양직선이 교차되는 지점을 성숙가능한계기로 보면 이 시기는 못자리 일수와 밀접한 관계가 있어서 30~40일묘는 6월 10일 반중기에 해당하나, 70~80일묘에서는 5월 1일로서 못자리 일수가 길어짐에 따라 성숙한계기는 당겨진다. 17) 천입중은 보통기재배에서 가장 무겁고 극조기재배를 하거나 만기재배에서 천입중은 저하한다. 7. 고중 및 완전정조중 : 18) 품종의 조만에 큰 영향없이 III~IV 파종기까지의 조기재배 하에서는 못자리 일수의 장단에 의한 고중의 큰 변이는 없으나, 파종기가 계속 이동하여 보통기재배가 되면 못자리 일수가 길어짐에 따라 차차 고종이 감소되어 오다가 만파가 되자 그 감소정도가 급격해졌다. 19) 파종기(X)와 정조수량(Y)과의 관계는 품종ㆍ못자리 일수를 종합하여 직선에 가까운 포물선으로 나타낼 수 있었다(Y=77.28-7.44X$_1$-1.001X$_2$). 따라서 조파시에는 정조수량의 변이가 작으나 어느 시기보다 파종기가 늦어짐에 따라서 정조수량은 감소하며, 그 정도는 만파인 경우에 심하고, 또 못자리 일수가 길어짐에 따라 더욱 현저하다. 20) 출수일수(X)에 대한 정조수량(Y)의 관계는 품종ㆍ못자리 일수를 구별하지 않고 보아다 회귀직선식으로써 나타낼 수 있었으나, 출수일수가 60~110일 정도까지는 조생종이 수량이 많고 만생종은 만기재배에 해당하므로 정조중의 감소가 심하였고, 출수일수가 140일 정도 이상이 되면 정조중이 거의 증가하지 않은 경향이 뚜렷하였다.

  • PDF