• Title/Summary/Keyword: cross area

Search Result 3,149, Processing Time 0.035 seconds

Mean Value of Median Nerve Cross-sectional Area in Healthy 20s and 30s in Busan Area

  • Kang, Kyoung-Hwa;Lee, Gil-Hyun;Choi, Go-Eun;Hyun, Kyung-Yae
    • Biomedical Science Letters
    • /
    • v.26 no.3
    • /
    • pp.186-191
    • /
    • 2020
  • This study was designed to investigate the median nerve cross-sectional area of the upper extremity which is the main cause of CTS in the 20s and 30s. The median nerve cross-sectional area (MNC-area) of each part of the upper limb was measured in healthy 20s and 30s females and males without neurological diseases or other diseases. This MNC-area was compared with the hand, wrist, finger, and other body indexes. The research group was divided into 20s female and male groups, and the 30s were also divided into female and male groups. In the comparison between the ages, the hand, and wrist configurations in the 30s were significantly higher than those of the 20s. The mean median nerve cross-sectional area was significantly larger in the male group than in the female group in both 20s and 30s, and it was larger in both men and women than in the 20s. Hand and wrist configurations were also positively correlated with the median nerve cross-sectional area in both 20s and 30s. The median values of hand ratio and wrist ratio were 2.26 and 0.65, respectively. This median value of hand ratio was inversely correlated with the median nerve cross-sectional area. The median nerve cross-area of the 20s was 6.88~7.38 ㎟ in the male group and 5.69~6.99 ㎟ in the female group, respectively. The median nerve cross-area of the 30s was 6.32~8.89 ㎟ in the male group and 6.15~7.17 ㎟ in the female group, respectively. The mean median nerve cross-sectional area was positively correlated with body mass index in both groups. Most of the variables were higher in their 30s than in their 20s.

CFD Analysis on a Flow Channel of a Bipolar Plate with Varying Cross-sectional Area in a PEM Fuel Cell (PEM 연료전지용 Bipolar Plate의 변화단면 유로에 대한 CFD 해석)

  • Yang, Dong-Jin;Park, Woon-Jean
    • New & Renewable Energy
    • /
    • v.3 no.3
    • /
    • pp.14-19
    • /
    • 2007
  • A flow channel model of a bipolar plate with varying cross-sectional area was newly designed for improving performance and efficiency of a PEM fuel cell stack. As a result, the varying cross-sectional area model showed poor uniformity in velocity distribution, however, maximum velocity in the flow path is about 30% faster than that of the uniform cross-sectional area model. The proposed varying cross-sectional area model is expected to diffuse operating fluids more easily into diffusion layer because it has relatively higher values in pressure distribution compared with other flow channel models. It is expected that the implementation of the varying cross-sectional area model can reduce not only the mass transport loss but also the activation loss in a PEM fuel cell, and open circuit voltage of a fuel cell can thus be increased slightly.

  • PDF

Analysis of HTS Current Lead with Variable Area (단면적 변화를 가지는 고온초전도체 전류도입선 해석)

  • 문성수;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.22-25
    • /
    • 2000
  • To improve the performance of high temperature superconducting current leads, variable cross-sectional area is considered. The cross-sectional area is varied as a function of current density to fix the safety factor along lead length. New integration method is devised to find optimum cross-sectional area distribution. New design of current lead has low heat leak into cryostat and less material than constant cross-sectional area leads. Conduction cooled lead is considered. The developed method is applied to Bi2223 current leads sheathed Ag-Au alloy.

  • PDF

Shape Optimization of the Cross Section for a Non-circular Spring Wire of Valve Springs for an Automotive Engine (자동차 엔진 밸브 스프링에 사용되는 비원형 스프링 선의 단면 형상 최적화)

  • Kim, Do-Joong;Kim, Young-Kyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2011
  • Valve springs with non-circular cross-section are widely used in automotive engines. Because of the reduced height, the oval cross-section provides some merits in its install height and stress distribution. This paper introduces a new method to generate optimal shape of the non-circular cross-section. For given width and height, arbitrary shape of the cross-section are described using the Hermite spline curves. Cross-section area and maximum stress level are chosen as performance indices, and nonlinear optimization problems are formulated with inequality constraints. Compared to a production spring wire, cross-section area can be reduced about 2.4 [%] without increasing maximum stress level. In addition, the other approach gives an optimum cross-section which reduces maximum stress level of 2.0 [%] without increasing cross-section area.

CEPHALOMETRIC STUDY OF OBSTRUCTIVE SLEEP APNEA PATIENTS IN THE UPRIGHT AND SUPINE POSITIONS

  • Kim, Jong-Chul;Lowe, Alan A
    • The korean journal of orthodontics
    • /
    • v.25 no.6 s.53
    • /
    • pp.655-664
    • /
    • 1995
  • Sixty male patients with polysomnographically documented OSA were included in this study. A pair of cephalograms were obtained in the upright and supine positions. In the supine position, the ANB angle, lower facial height and the cross-sectional area of soft palate increased and there was a decrease in the vertical airway length and oropharynx cross-sectional area. Positional changes did not affect the cross-sectional area of tongue, but the cross-sectional area of the oropharynx decreased in the supine position. The obese group had higher AI and RDI. Maxillary unit length, C3-H, the cross-sectional areas of tongue, soft palate and oropharynx were significantly greater in the group Obese than in non-obese group. No correlation was noted between the mandibular unit length and OSA severity, The group of small mandibular unit length showed shorter lower facial height and maxillary unit length, and smaller cross-sectional area of tongue than the long mandibular unit length group. Hyold bone positioned more inferiorly and cross-sectional area of nasopharynx decreased as the OSA severity increased.

  • PDF

The Findings of Relation between Cross-sectional Area of Lumbar Paraspinal Muscle and Prognosis in Patients of Acute and Chronic Low Back Pain Patients (급성 및 만성 요통환자의 요부주위근 횡단면적과 요통 예후의 상관관계 연구)

  • Nam, Ji Hwan;Lee, Chong Hwan;Lee, Seul Ji;Kim, Kie Won;Lee, Min Jung;Jun, Jae Yun;Lim, Su Jin;Hong, Nam Jung;Song, Ju Hyun
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.45-53
    • /
    • 2013
  • Objectives : The purpose of this study was to evaluate the relationship between cross-sectional areas of the paraspinal and psoas muscles with low back pain. Methods : We assessed the cross-sectional area of the psoas and paraspinal muscles at the superior part of L4 level and vertebral body of L4 of 132 patients who were hospitalized with a chief complaint of low back pain at Jaseng Hospital of Korean Medicine from January 2013 to April 2013. After calculating the mean psoas area, we divided the patients into 2 groups by whether the psoas cross section was larger or smaller than the mean, and compared the admission period, verbal numeric rating scale(NRS) of low back pain(LBP), and improvement of verbal NRS of LBP. We also subcategorized the patients into acute and chronic groups according to the duration period, and compared the cross-sectional area of the psoas and paraspinal muscles. Results : Although analyses of the verbal NRS of LBP, and improvement of verbal NRS of LBP between groups with larger and smaller psoas cross section areas showed no significant difference, the admission period was significantly shorter in the group with larger psoas cross section areas. There was no significant difference in analyses of cross section areas in the acute and chronic groups. Of the possible prognostic variables, improvement of verbal NRS of LBP showed no correlation, while the admission period displayed a significant correlation. The cross-sectional area of the psoas and paraspinal muscles divided by the area of the vertebral body of L4 had a significant negative correlation with age. Conclusions : The cross-sectional area of the psoas and paraspinal muscles were correlated with the admission period in LBP patients, and the cross-sectional area of the surrounding muscles divided by the area of the L4 vertebral body was negatively correlated with age.

Cross sectional area change of the dural-sac according to impact duration in a spinal motion segment FE model (척추운동분절 FE모델에서 충격시간에 따른 마미 단면적의 변화)

  • Kim, Y. E.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.117-120
    • /
    • 2002
  • In this study the occlusion of dural-sac, the outer membrane of spinal cord in the lumbar region, was quantitatively analyzed using one motion segment finite element model. Occlusion was quantified by calculating cross sectional area change of dural-sac far different compressive impact duration(loading rate) due to bony fragment at the posterior wall of the cortical shell in vertebral body. Dural-sac was occluded most highly in the range of 8∼12 msec impact duration by the bony fragment intruding into the spinal canal. t=400 msec case 4% cross sectional area change was calculated, which is the same as the cross sectional area change under 6 kN of static compressive loading.

  • PDF

Chip Forming Characteristics of Bi-S Free Machining Steel (Bi-S 쾌삭강의 칩생성특성)

  • 조삼규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.48-54
    • /
    • 2000
  • In this study the characteristics of chip formation of the cold drawn Bi-S free machining steels were assessed. And for comparison those of the cold drawn Pb-S free machining steel the hot rolled low carbon steel which has MnS as free machining inclusions and the conventional steels were also investigated. During chip formation the cold drawn free machining steels show relatively little change in thickness and width of chip compare to those of the conventional carbon steels. And a single parameter which indicates the degree of deformation during chip formation chip cross-section area ratio is introduced. The chip cross-section area ratio is defined as chip cross-section area is divided by undeformed chip cross-section area. The variational patters of the chip cross-section area ratio of the materials cut are similar to those of the shear strain values. The shear stress however seems to be dependent on the carbon content of the materials. The cold drawn Bi-S and Pb-S steels show nearly the same chip forming behaviors and the energy consumed during chip formation is almost same. A low carbon steel without free machining aids shows poor chip breakability due to its high ductility. By introducing a small amount of free machining inclusions such as MnS Bi, Pb or merely increasing carbon content the chip breakability improves significantly.

  • PDF

Chip Forming Characteristics of Bi-S Free Machining Steel (Bi-S 쾌삭강의 칩생성특성)

  • 이영문
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.351-356
    • /
    • 1999
  • In this study, the characteristics of chip formation of the cold drawn Bi-S free machining steels were assessed. And for comparison, those of the cold drawn Pb-S free machining steel, the hot rolled low carbon steel which has MnS as free machining inclusions and the conventional steels were also investigated. During chip formation, the cold drawn free machining steels show relatively little change in thickness and width of chip compare to those of the conventional carbon steels. And a single parameter which indicates the degree of deformation during chip formation, 'chip cross-section area ratio' is introduced. The chip cross-section area. The variational patterns of cross-section area is divided by undeformed chip cross-section area. The variational patterns of the chip cross-section area ratio of the materials cut are similar to those of the shear strain values. The shear stress, however, seems to be dependent on the carbon content of the materials. The cold drawn BiS and Pb-S steels show nearly the same chip forming behaviors and the energy consumed during chip formation is almost same. A low carbon steel without free machining aids shows poor chip breakability due to its high ductility. By introducing a small amount of non-metallic inclusions such as MnS, Bi, Pb or merely increasing carbon content the chip breakability improves significantly.

  • PDF

The Association between Cross-section of Lumbar Regional Muscle analyzed by MRI and Stability, Center of Pressure assessed by Tetrax (요통 환자의 요추 주변 근육 단면적과 신체안정성(Stability), 체중심(Center of Pressure)과의 관련성 : 동적평형검사(Tetrax)를 중심으로)

  • Seong, Ik-Hyun;Lee, Kap-Soo;Jung, Jae Hoon;Kim, Won-Woo;Cho, Chang-Young;Choi, Chul-Woo;Ha, In-Hyuk
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.8 no.2
    • /
    • pp.39-46
    • /
    • 2013
  • Objectives : To identify the association between cross-sectional area of lumbar regional muscle and stability(ST), center of pressure(COP) assessed by tetrax. Methods : Patients(n=55) who had taken L-SPINE MRI and Tetrax(Sunlight, Israel) were analyzed retrospectively. To evaluate the cross-sectional area of lumbar regional muscle, L-SPINE MRI was used. Data of ST, COP were accumulated by using dynamic equilibrium analysis by Tetrax. Of the lumbar regional muscles, the Psoas muscles and the Paraspinalis muscles were examined. Using Pearson correlation, we analyzed COP, ST and the difference between the cross-sectional area of lumbar regional muscles. Results : The variance of cross-sectional area of both sides of Psoas muscle and COP had moderate positive correlation(r=0.621). Between variance of cross-sectional area of both sides of Paraspinalis and lumbar regional muscle and COP there was low positive correlation(r=0.287, r=0.329) ST also had low correlation with variance of cross-sectional area of both sides of Psoas muscle. Conclusion : The variance of cross-sectional area between both sides of Psoas muscle had moderate correlation with COP.

  • PDF