• Title/Summary/Keyword: cross -sectional image

Search Result 296, Processing Time 0.026 seconds

Distortion Correction in Magnetic Resonance Images on the Measurement of Muscle Cross-sectional Area (자기공명영상을 이용한 근육 단면적 측정법의 활용을 위한 영상왜곡보정)

  • Hong, Cheol-Pyo;Lee, Dong-Hoon;Park, Ji-Won;Han, Bong-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.66-72
    • /
    • 2012
  • Purpose: The purpose of this study is to explore the importance of the image distortion correction in the cross sectional area measurement for the iliopsas muscle, tensor fasciae latae muscle, gluteus maximus muscle and the knee extensor muscles, by using (magnetic resonance imaging) MRI. Methods: This study was performed using an open 0.32T MRI system. To estimate the image distortion, T1 images for an AAPM homogeneity/linearity phantom were acquired, and the region in which the maximum geometric distortion was less than or equal to the pixel size (1.6 mm) of the images, it was defined as the distortion correction-free region. The T2 images for a human subject's pelvis and thigh in normal positions were obtained. Then, after the regions of interest in the pelvis and thigh were moved into the distortion correction-free region, T2 images for the pelvis and thigh were scanned with the same imaging parameters used in the previous T2 imaging. The cross-sectional areas were measured in the two T2 images that were obtained in the normal position, and the distortion correction-free region, as well as the area error caused by geometric image distortion was calculated. Results: The geometrical distortion is gradually increased, from the magnet center to the outer region, in axial and coronal plane. The cross-sectional area error of gluteus maximus muscle and the knee extensors was as high as 9.27% and 3.16% in before and after distortion correction, respectively. Conclusion: The cross-sectional area of the muscles that suffered from the geometrical distortion is necessary to correct for the estimation of the intervention.

Image Reformation with a Personal Computer for Dental Implant Planning (치과 임플란트 계획시 개인용 컴퓨터를 이용한 영상재형성에 관한 연구)

  • Eun-Kyung Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.255-264
    • /
    • 1996
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 4 mandibles of 4 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. personal computer used for image reformation was PowerWave 604/120 (Power computing Co, U.S.A. ) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and ImportACLESS Vl.1 (Designed Access Co., U.S.A.) for importing CT images and NIH image 1.58 (NIH, U.S.A.) for image processing. Seven image were selected among the serial reconstructed cross-sectional images produced by Dentascan. Seven resliced cross-sectional images at the same position were obtained at the personal computer. Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformer cross-sectional images using Mac-compatible computer was highly correlated with those using workstation with Dentascan software(height : r2= 0.999, p<0.001, width : r2= 0.993, p <0.001). So, it is considered that we can use a personal computer with inexpensive software for the dental implant planning, instead of the expensive software and workstation.

  • PDF

Comparison of Image reformation Using Personal Computer with Dentascan Program (CT scan의 다평면 재구성을 하는 Dentascan 프로그램과 개인용 컴퓨터를 이용한 영상재형성과의 비교에 관한 연구)

  • KIM Eun Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.7-16
    • /
    • 1997
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 5 mandibles of 5 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. Personal computer used for image reformation was PowerWave 6041120 (Power Computing Co, U.S.A.) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and Import ACCESS V1.H Designed Access Co., U.S.A.) for importing CT images and NIH Image 1.58 (NIH, U.S.A.) for image processing. Seven images were selected among the serial reconstructed cross-sectional images produced by Dentascan(DS group). Seven resliced cross-sectional images at the same position were obtained at the personal computer(PC group). Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformed cross-sectional images using Mac-compatible computer were highly correlated with those using workstation with Dentascan software(height : r²=0.999, p<0.001, width : r²=0.991, p<0.001). So, it is considered that we can use a personal computer with inexpensive softwares for the dental implant planning, instead of the expensive software and workstation.

  • PDF

The Evaluation Model of Aggregate Distribution for Lightweight Concrete Using Image Analysis Method (이미지 분석을 이용한 경량골재 콘크리트의 골재분포 판정기법 개발)

  • Ji, Suk-Won
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.10
    • /
    • pp.11-18
    • /
    • 2018
  • In this study, the cross-sectional image has been acquired to evaluate the aggregate distribution affecting quality of lightweight aggregate concrete, and through the binarization method, the study is to calculate the aggregate area of upper and lower sections to develop the method to assess the aggregate distribution of concrete. The acquisition of cross-section image of concrete for the above was available from the cross-sectional photography of cleavage tension of a normal test specimen, and an easily accessible and convenient image analysis software was used for image analysis. As a result, through such image analyses, the proportion of aggregate distribution of upper and lower sections of the test specien could be calculated, and the proportion of aggregate area U/L value of the upper and lower regions of concrete cross-section was calculated, revealing that it could be used as the comprehensive index of aggregate distribution. Moreover, through such method, relatively easy image acquisition methods and analytic methods have been proposed, and this indicated that the development of modeling to assess aggregate distribution quantitatively is available. Based on these methods, it is expected that the extraction of fundamental data to reconsider the connectivity with processes in concrete will be available through quality assessment of quantitative concrete.

COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION (CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구)

  • Jung Gi-Hun;Kim Eun-Kyung;Kim Sang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

Prediction of Cured Cross-sectional Image in Projection Microstereolithography (전사방식 마이크로광조형의 경화 단면형상 예측)

  • Kim, Sung-Hyun;Park, In-Baek;Ha, Young-Myoung;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.102-108
    • /
    • 2010
  • Projection microstereolithography is a process of fabricating a micro-structure by using dynamic mask such as digital micromirror device(DMD). DMD shapes the beam into cross-sectional image of structure. Photocurable resin is cured by the beam and stacked layer on top of layer. It is difficult to deliver the beam from the DMD to the photocurable resin without any distortions. We assume that the beam exposed to the resin by 1 pixel of DMD has Gaussian distribution, so the shaped beam reflected by the DMD affects its neighboring area. Curing pattern corresponding to a cross-sectional images is predicted by superposition of pixels of Gaussian distribution and it is similar to cured shape.

Defect Detection of Brazing Joint in Heat Exchanger Using X-ray Image (X-선을 이용한 열교환기 브레이징 접합부 결함 검출)

  • Kim, Jin-Young;Seo, Sang-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.10
    • /
    • pp.1044-1050
    • /
    • 2011
  • The quality of brazing joints is one of the most important factors that have an effect on the performance of the brazing joint-based heat exchangers with the growing use in industry recently. Therefore, it is necessary to inspect the brazing joints in order to guarantee the performance of the heat exchangers. This paper presents a non-destructive method to inspect the brazing joints of the heat exchangers using X-ray. Firstly, X-ray cross-sectional images of the brazing joints are obtained by using CT (Computerized Tomography) technology. Cross-sectional image from CT is more useful to detect the inner defects than the traditional transmitted X-ray image. Secondly, the acquired images are processed by an algorithm proposed for the defect detection of brazing joint. Finally, two types of brazing joint are examined in a series of experiments to detect the defects in brazing joints. The experimental results show that the proposed algorithm is effective for defect detection of the brazing joints in heat exchangers.

Preparation of Cross-sectional Specimen for High Resolution Observation of Coating Structure and Visualization of Styrene/butadiene Latex Binder (고배율 도공층 구조 및 S/B latex 분포 분석을 위한 도공층 횡단면 제작)

  • Kim, Chae-Hoon;Youn, Hye-Jung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.4
    • /
    • pp.16-24
    • /
    • 2012
  • To characterize the coating structure, diverse methods such as mercury intrusion, nitrogen adsorption and oil absorption methods have been developed and widely employed. These indirect techniques, however, have some limitation to explain the actual coating structure. Recently microscopic observation methods have been tried for analyzing structural characteristics of coating layers. Preparation of the undamaged cross section of a coating layer is essential for obtaining high quality image for analysis. In this study, distortion-free cross-section of the coating layer was prepared using a grinding and polishing technique. The coated paper was embedded in epoxy resin and cured. After curing the resin block it was ground with abrasive papers and then polished with diamond particle suspension and nylon cloth. Polished coating layer was sufficient enough to obtain undamaged cross sectional images with scanning electron microscope under backscattered electron image mode. In addition, the SEM images allowed distinction of the coating layer components. Also S/B latex film formed between pigment particles was visualized by osmium tetroxide staining. Pore size distribution and pore orientation were evaluated by image analysis from SEM cross-sectional images.

Research for development of our own image processing code for neutron tomography (중성자 토모그래피를 위한 영상처리 자체코드 개발 연구)

  • Kim, Jin Man;Kim, TaeJoo;Yu, Dong In
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.1
    • /
    • pp.44-49
    • /
    • 2020
  • Neutron radiography has been widely used in many research areas due to its different characteristics from X-rays. Neutron tomography is a powerful tool because it can clearly show the inside of an object that the eye cannot see. However, generally, commercial software is used for the reconstruction of neutron tomography. It means that maintenance costs are incurred and analysis is inefficient in some cases. In this respect, our own image processing code is required to reconstruct neutron images efficiently. In this study, an image processing code is developed for reconstruction of cross-sectional images from neutron radiography taken from the side of the object. Using the developed code, cross-sectional images of the sample are successfully reconstructed.

Acquirement of in vivo epidermal cross-sectional image by using swept source optical coherence tomography (SS-OCT 방식을 이용한 생체의 표피단면 영상 획득)

  • Kim, Hoon-Sup;Lim, Hae-Jin;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.163-166
    • /
    • 2008
  • In this paper, the swept source optical coherence tomography system has realized using a free-space interferometer based on a beam splitter. Personal computer has completed the control for tunable wavelength laser digitally and the B-scan motor as well. From each experiment for an onion and a salmon egg, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF