• 제목/요약/키워드: critical strain energy release rate mode II properties

검색결과 4건 처리시간 0.016초

표면처리된 탄화규소강화 에폭시 복합재료의 GIIC 특성 (A Study on Critical Strain Energy Release Rate Mode II of Chemically Treated SiC-filled Epoxy Composites)

  • 박수진;오진석
    • 접착 및 계면
    • /
    • 제6권4호
    • /
    • pp.1-6
    • /
    • 2005
  • 본 실험에서는 화학적 표면처리된 탄화규소의 첨가가 탄화규소(SiC)/에폭시 복합재료의 critical strain energy release rate mode II ($G_{IIC}$) 특성에 미치는 영향에 대하여 알아보았으며, 표면처리된 SiC의 표면특성은 산 염기도와 FT-IR을 사용하여 알아보았다. 또한 복합재료의 기계적 계면물성은 $G_{IIC}$를 통하여 알아보았다. 실험결과, 산성 용액으로 표면처리한 SiC (A-SiC)의 표면 산도가 염기성(B-SiC) 또는 표면처리 하지 않은 SiC (V-SiC)보다 높으며, $G_{IIC}$의 크랙저항 특성은 A-SiC가 향상되었는데, 이러한 결과는 SiC 충전재와 에폭시 수지간의 분자간 계면결합력의 향상 때문으로 판단된다.

  • PDF

Effect of Atmospheric Plasma Treatment of Carbon Fibers on Crack Resistance of Carbon Fibers-reinforced Epoxy Composites

  • Park, Soo-Jin;Oh, Jin-Seok;Rhee, Kyong-Yop
    • Carbon letters
    • /
    • 제6권2호
    • /
    • pp.106-110
    • /
    • 2005
  • In this work, the effects of atmospheric oxygen plasma treatment of carbon fibers on mechanical interfacial properties of carbon fibers-reinforced epoxy matrix composites was studied. The surface properties of the carbon fibers were determined by acid/base values, Fourier-transform infrared spectrometer (FT-IR), and X-ray photoelectron spectroscopy (XPS) analyses. Also, the crack resistance properties of the composites were investigated in critical stress intensity factor ($K_{IC}$), and critical strain energy release rate mode II ($G_{IIC}$) measurements. As experimental results, FT-IR of the carbon fibers showed that the carboxyl/ester groups (C=O) at 1632 $cm^{-1}$ and hydroxyl group (O-H) at 3450 $cm^{-1}$ were observed for the plasma treated carbon fibers, and the treated carbon fibers had the higher O-H peak intensity than that of the untreated ones. The XPS results also indicated that the $O_{1S}/C_{1S}$ ratio of the carbon fiber surfaces treated by the oxygen plasma led to development of oxygen-containing functional groups. The mechanical interfacial properties of the composites, including $K_{IC}$ (critical stress intensity factor) and $G_{IIC}$ (critical strain energy release rate mode II), were also improved for the oxygen plasma-treated carbon fibersreinforced composites. These results could be explained that the oxygen plasma treatment played an important role to increase interfacial adhesions between carbon fibers and epoxy matrix resins in our composite system.

  • PDF

플라즈마 처리가 탄소섬유강화 복합재료의 기계적특성에 미치는 영향 (Effect of Plasma Treatment on Mechanical Properties of Carbon Fibers-reinforced Composites)

  • 오진석;이재락;박수진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.80-83
    • /
    • 2005
  • In this work, effects of oxygen plasma on surface characteristics of carbon fibers were investigated in mechanical properties interfacial of carbon fibers-reinforced composites. The surface properties of the carbon fibers were determined by acid/base values, FT-IR, and X-ray photoelectron spectroscopy (XPS). Also, the mechanical properties of the composites were studied in and critical stress intensity factor ($K_{IC}$) and critical strain energy release rate mode II ($G_{IIC}$) measurements. As experimental results, the $O_{lS}/C_{lS}$ ratio of the carbon fiber surfaces treated by oxygen plasma was increased compared to that of untreated ones, possibly due to development of oxygen-containing functional groups. The mechanical properties of the composites, including $K_{IC}$ and $G_{IIC}$ had been improved in the oxygen plasma on fibers. These results could be explained that the oxygen plasma was resulted in the increase of the adhesion of between fibers and matrix in a composite system.

  • PDF

탄화규소의 첨가가 탄소섬유 강화 복합재료의 열안정성 및 기계적 계면특성에 미치는 영향 (Influence of SiC on Thermal Stabilities and Mechanical Interfacial Properties of Carbon Fibers-reinforced Composites)

  • 오진석;박수진;이재락;김영근
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.182-185
    • /
    • 2004
  • In this work, the effect of chemical treatments on surface properties of SiC was investigated in mechanical interfacial properties of carbon fibers-reinforced composites. The surface properties of the SiC were determined by acid/base values and contact angles. The thermal stabilities of carbon fibers-reinforced composites were investigated by thermogravimetric analysis (TGA). Also, the mechanical interfacial properties of the composites were studied in interlaminar shear strength (ILSS) and critical strain energy release rate mode II $(G_{IIC})$ measurements. As a result, tile acidically treated SiC (A-SiC) had higher acid value than that of untreated SiC (V-SiC) or basically treated SiC (B-SiC). According to the contact angle measurements, it was observed that chemical treatments led to an increase of surface free energy of the SiC surfaces, mainly due to the increase of the specific (polar) component. The mechanical interfacial properties of the composites, including ILSS and $(G_{IIC})$, had been improved in the specimens treated by chemical solutions. These results were explained that good wetting played an important role in improving the degree of adhesion at interfaces between SiC and epoxy resin matrix.

  • PDF